ABB Signal
Easy solutions
© ABB Group WA
May 3, 2017 | Slide 1
Modular system

Selection of individual apparatus, which connected to each
other, form versatile calling and alarm systems.
Reset
Call
© ABB Group WA
May 3, 2017 | Slide 2
Included in standard WA -series
ABB Signal products are part of Jussi and
Impressivo WA series => uniform installation


Area sales can manage
Products available at the local wholesaler!
© ABB Group WA
May 3, 2017 | Slide 3
From Jussi to Impressivo

Jussi centerparts are removed and changed to corresponding Impressivo parts

8 pcs Impressivo centerpart packages covers all Jussi signal products

All Impressivo colours available
+
© ABB Group WA
May 3, 2017 | Slide 4
+
=
Good marking possibilities
Name plates
Cancel
Alarm
OCCUPIED
abc
abc
Buttons
© ABB Group WA
May 3, 2017 | Slide 5
Easy
individual products are
simple functions
systems are formed by
connecting the products
with each other
systems become always
easy and simple
easy to manage, only ~20
products




Modular
customer orientated systems
compatible to other systems
extendable
surface - and flush mounting




Economical
Reliable



simple => reliable
common tele cabling
wide supply voltage range
=> no reclamations
© ABB Group WA
May 3, 2017 | Slide 6



price / quality
pay only for needed features
low cost maintenance
Applications
Signaling
A-B
Alarm systems

HVAC -alarm panels

gas alarm for hospitals

back door control

door buzzer

level control

leak guard...
disabled WC
public buildings...
 nurse call
hospitals
health centres
day centres...
 panic alarm
social offices
labour offices
health centres
hospitals
banks...
 service call
day centres
offices
hotels, restaurants, shops...

Office signal systems
© ABB Group WA
May 3, 2017 | Slide 7
Calling systems

door buzzers

“busy” -light

office “traffic light”...
Transformer
Control Units
Push Buttons /
Switches
Signaling Devices
Jussi accessories
signal
…
Impressivo centerparts
1P-8x
Office Signal system
2P-8x
4P-8x
PT-8x
Disabled WC SET
T-8x
V-8x
6V-8x
U-8x
Leak Guard SET
Markets
Jussi & Impressivo
signalling products
Wiring Accessories
Busch-Infoline®
Reflex SI
Solo/future/carat
Signal adapted in
Basic 55
NIESSEN
Sistema de Avisos
y Señalización®
Arco
© ABB Group WA
May 3, 2017 | Slide 9
Elektro-Praga
Signal products
Reflex SI
Time Element
Easy solutions
© ABB Group WA
May 3, 2017 | Slide 10
Control Unit operation
© ABB Group WA
May 3, 2017 | Slide 11
Basic system / Disabled toilet
The system serves disabled people and other people who
need help in WC´s
Anrop
© ABB Group WA
May 3, 2017 | Slide 12
Återställ
ning
trafo
Larm
Basic connection / Disabled toilet
Based on FEH2001
FJW1003
alarm
E-Nr 5506092
FJW1004
call
Note ! resistor
© ABB Group WA
May 3, 2017 | Slide 13
call
reset
trafo
El-num 6315560
Basic connection / Disabled toilet
Based on FEH1001
alarm
Note ! resistor
trafo
call
reset
© ABB Group March 12, 2009 | Slide ‹#›
© ABB Group WA
May 3, 2017 | Slide 14
Disabled toilet with KNX
© ABB Group WA
May 3, 2017 | Slide 15

System could be equipped with several parallel calling
buttons and could be connected with US/U2.2 to KNX. In
this way severals separate Disabled toilet alarms could be
connected to a common panel

KNX-system could be also used together with:

Occupied light system

Day center calling system

Panic alarm system

Leakage guard system
Signal system connection to KNX
call
© ABB Group WA
May 3, 2017 | Slide 16
reset
trafo
alarm
Leak Guard
Leak Guard controls water using devices and domestic
appliances as well as the construction, where the water
damages are most evident.
sensor
© ABB Group WA
May 3, 2017 | Slide 17
alarm
Leak
guard
trafo
Mains relay
Leak Guard
FJW2100
E-Nr 5506091
El-num 6315570
Note ! NO resistor
© ABB Group WA
May 3, 2017 | Slide 18
Panic alarm in social office
The panic alarm system is suitable for giving the employees basic protection against
violence in public agencies and offices.
call
© ABB Group WA
May 3, 2017 | Slide 19
alarm
light
reset
Panic alarm in social office
Room 1
Room 3
Room 4
Room 2
Office
Room 5
FIM1000 + V-84
FIM1200 + V-84
FEH1001 + 1P-84
FAP2001 + 1P-84
© ABB Group WA
May 3, 2017 | Slide 20
Panic alarm in social office
© ABB Group WA
May 3, 2017 | Slide 21
Calling system in day centers
This system is suitable for day centers, where there are calling buttons in each apartment.
The nurse receives the alarms at one alarm panel which is located in the office.
call
reset
© ABB Group March 12, 2009 | Slide ‹#›
© ABB Group WA
May 3, 2017 | Slide 22
light
panel
Buzzer
reset
call
trafo
Calling system in day centers
© ABB Group WA
May 3, 2017 | Slide 23
Entrance request in office hotels
This system is well suitable for office hotels or clinics. The system enables to transfer a
signal from the front door inside to several receiving points. The signal can be cancelled
from each receiving point. At the same time one can open the front door remotely.
Alarm & reset
© ABB Group WA
May 3, 2017 | Slide 24
call
Entrance request in office hotels
© ABB Group WA
May 3, 2017 | Slide 25
Busy Light
The busy light is used in offices, conference etc rooms to
indicate the message ”don´t disturb” to people outside the room.
switch
© ABB Group WA
May 3, 2017 | Slide 26
light
trafo
Table push
button and
switch also
available
Busy Light
© ABB Group WA
May 3, 2017 | Slide 27
Office Signal
The Office Signal System is suitable in public buildings for example
offices and hospitals, where one has to wait for his/her own turn
before entering the room. The system installations can be easily and
flexible done in flush- and surface mounted boxes and trunkings
Name
plate
© ABB Group WA
May 3, 2017 | Slide 28
Door unit
relay
Terminal for
door unit
Table unit
Office Signal
© ABB Group WA
May 3, 2017 | Slide 29
Thanks