Coronary CT
angiography using dual
source CT
Naofumi Matsunaga
Department of Radiology, Yamaguchi University
Graduate School of Medicine
Talk outline
• Temporal resolution is 83
msec of dual source CT
Faster shutter chance
•Introduction of newly developed
Somatom Definition Flash
DSCT Improvement of Temporal Resolution
Dual Source CT needs only 90 deg. rotation
Single Source CT
330 ms / 2 = 165 ms (FWHM)
Page 3
Dual Source CT
330 ms / 4 = 83 ms (FWHM)
Cardiac
cycle
1) Isovolumetric
ventricular contraction
3) Isovolumetric
ventricular
relaxation
2) Ejection
Diastasis
(0-300ms)
(80-120ms)
4) Rapid filling
5) Atrial contraction
Time resolution needed for 64MSCT
Isovolumetric relaxation time and Diastasis
ECG
Isovolumetric
relaxation
time
(80-120ms)
Diastasis
(0-300ms)
outflow
inflow
In two phases, the heart is free-motion, Time
resolution of dual source CT is 83 msec, and sufficient
for data acqusition. Simply speaking, two phase of
best shutter chance.
Cardiac
cycle
During the
isovolumetric relaxation
phase, semilunar and
AV valves sets of
valves are closed .-------Æmotion free
Cited from Human
Physiology, Mosby 1993,
p374,
Isovolumic relaxation time(IRT)
and Diastasis evaluated by dual doppler echo
A
A normal case
Outflow
HR=60 bpm
IRT=90msec
more than 83msec
Diastasis=300msec
more than 83msec
IRT
diastasis
Inflow
A
A normal case
E
Outflow
Inflow
IRT
diastasis
HR=80 bpm
IRT=100msec
more than 83msec
Diastasis=0msec
less than 83msec
Courtesy of Dr Miura,
Yamaguchi University
Isovolumic relaxation time(IRT)
and Diastasis evaluated by dual doppler echo
A
E
A normal case
HR=60 bpm
IRT=90msec
more than 83msec
Diastasis=300msec
more than 83msec
diastasis
IRT
E
IRT
A
diastasis
A case of congestive
heart failure
HR=60 bpm
IRT=110msec
more than 83msec
Diastasis=0msec
less than 83msec
Courtesy of Dr Miura,
Yamaguchi University
Change of IRT and Diastasis by heart rate
Time
(msec)
IRT
Diastasis
*:P<0.01 VS HR≦60
200
165
*
100
*
83
0
SSCT
DSCT
HR≦60
(N=7)
60<HR≦65
(N=10)
Courtesy of Dr Fujimura, Yamaguchi University
65<HR≦75
(N=8)
75≦HR HR(/min)
(N=7)
RSNA 2008, Education Exhibit
No β blocker in dual source CT
1.No need to consideration of contraindication of
β blocker.
hypersensitivity to β blocker、diabetic
ketoacidosis、metabolic acidosis、marked
bradycardia、AV block、 SA block 、sick sinus
syndrome、cardiogenic shock、pulmonary
hypertension、congestive heart failure、severe
peripheral vascular disease、hypotension、
bronchial asthma、pheochromocytoma
2.No waiting time after administration of β blocker
# Use of β blocker is stressful for the radiologist and cardiologist in the CT room.
Diagnostic accuracy according to
heart rate
Brodoefel H, et
al: Radiology
247;346-355
Good image quality without use of β
blocker even if the heart rate is 97bpm
RCA
LAD
LCX
SOMATOM Definition Flash
Flash speed. Lowest dose.
SOMATOM Definition Flash
Flash speed. Lowest dose.
Dual Source CT on Next Stage
Dual Source CT
‹ Cardiac Imaging
¾ 83msec Temporal Resolution
¾ no β-blocker
¾ Low Dose
‹ Dual Energy Imaging
SOMATOM Definition Flash
Flash speed. Lowest dose.
Specifications
X-Ray Tube
Power
Detector
Gantry Rotation
Temporal Resolution
Spatial Resolution
FOV (A /B system)
Straton x 2
100kw x 2
128 slice x 2
0.28Sec/rot.
75ms
0.33mm
500/330mm
78cm
780 mm gantry aperture
2000 mm scan range
200cm S
can
Range
SOMATOM Definition Flash
Flash speed. Lowest dose.
Single source CT
Result:
Single Single
sourcesource
CT @ high
CT isscan
limited to
slow
speed
pitch
would
andcause
slow scan
acquisition
speed gaps
DSCT Flash Spiral
High-Pitch Double Spiral
Solution: Flash spiral enables
pitch 3.2 for fastest speed of
43 cm/sec without any gaps
SOMATOM Definition Flash
Flash speed. Lowest dose.
Conventional Technology
ƒ Thorax: 5 s, breath hold
ƒ Triple rule-out: 20 s, 20 mSv
ƒ Pediatric: > 4s, sedation
ƒ Whole body: > 10 s
DSCT Flash Spiral
ƒ Thorax: 0.6 s, no breath hold
ƒ Triple rule-out: 0.6 s, < 5 mSv
ƒ Pediatric: < 1s, no sedation
ƒ Whole body: 4 s
SOMATOM Definition Flash
Flash speed. Lowest dose.
Conventional Technology
Scan
ƒ Thorax: 5 s, breath hold
ƒ Triple rule-out: 20 s, 20 mSv
ƒ Pediatric: > 4s, sedation
ƒ Whole body: > 10 s
ƒ 4D dynamic scans: 16 cm
DSCT Flash Spiral
Scan
ƒ Thorax: 0.6 s, no breath hold
ƒ Triple rule-out: 0.6 s, < 5 mSv
ƒ Pediatric: < 1s, no sedation
ƒ Whole body: 4 s
ƒ 4D dynamic scans: 48 cm
SOMATOM Definition Flash
Sub-mSv heart
DSCT Cardio Flash Spiral
Conventional CTA
ƒ
ƒ
ƒ
ƒ
ƒ
135-175 ms temporal resolution
5-10 s scan time
Slow pitch for overlapping acquisition
Segment Reconstruction
8-40 mSv dose
High-Pitch Double Spiral
ƒ
ƒ
ƒ
ƒ
75 ms temporal resolution
250 ms scan time (quarter beat)
Breath hold optional
Down to < 1 mSv dose
SOMATOM Definition Flash
Flash speed. Lowest dose.
Headline
SOMATOM
Definition
Flash
Flash speed.
Lowest dose.
HR independent
temp res. 75 ms
Coll. 128 x 0.6 mm
Spatial res. 0.33 mm
250 ms for 110 mm
Rotation 0.25 s
100 kV, 320 mAs / rotation
0.8 mSv
0.25s for 110 mm
0.8mSv
Courtesy of Friedrich-Alexander University Erlangen-Nuermberg - Institute of Medical Physics / Erlangen, Germany
SOMATOM Definition Flash
ImageSpiral Cardio
Flash
SOMATOM
Definition
Flash
Flash speed.
Lowest dose.
HR independent
temp res. 75 ms
Coll. 128 x 0.6 mm
Spatial res. 0.33 mm
280 ms for 120 mm
Rotation 0.28 s
100 kV, 320 mAs / rotation
0.95mSv
0.28s for 120 mm
0.95mSv
Courtesy of Friedrich-Alexander University Erlangen-Nuermberg - Institute of Medical Physics / Erlangen, Germany
SOMATOM Definition Flash
Low Dose Triple Rule-Out
Headline
SOMATOM
Definition
Flash
Flash speed.
Lowest dose.
HR independent
temp res. 75 ms
Coll. 128 x 0.6 mm
Spatial res. 0.33 mm
670 ms for 290 mm
Rotation 0.28 s
100 kV
97 kg, BMI 29.9
1.6mSv
0.67s for 290 mm
1.6mSv
Courtesy of Friedrich-Alexander University Erlangen-Nuermberg - Institute of Medical Physics / Erlangen, Germany
SOMATOM Definition Flash
Flash speed. Lowest dose.
Courtesy of Friedrich-Alexander University Erlangen-Nuermberg - Institute of Medical Physics / Erlangen, Germany
Summary
• Temporal resolution of DSCT is 83msec.
• Isometric relaxation time is always
constant,irrespective of heart rate or
decreased cardiac function,
• In this period, the heart is stopped, and
83msec is always sufficient for the best
chance for reconstruction.
• Therefore, dual source CT is widely
available in the patients from high to low
heart rate without premedication of
βblocker.
Summary
• Recently, innovative dual source
scanner (FLASH) is developed; fast
scan time less than 1 second, double
spiral scan.
• However, improvement of spatial
resolution is expected for more
detailed evaluation.
Acknowledgement
• With the courtesy of
Siemens In Corporation.
• Thank you for your
attention.