S TROUBLESHOOTING ≠CAUTION ≠ WHEN ADJUSTING THE TIME DELAY OR WHEN SWITCH IS UNSECURED, YOU SHOULD TURN OFF POWER TO THE SWITCH AT THE CIRCUIT BREAKER. To test and adjust the unit: 1. With a phillips screwdriver, turn Secondary Time Delay trimpot all the way counterclockwise, to minimum (5 minutes). Secondary Time Delay Trimpot Auto/Off Button 2. Temporarily secure the switch to the wall box. 3. Turn on power to the switch at circuit breaker and allow a one minute warm-up. Note: Whenever the main power is restored to the switch, such as when turning on the circuit breaker, the occupancy sensor charges and may take up to one minute to function properly. 4. Test the unit by pushing the Auto/Off button to the auto position and the dimming slider to maximum. Lights will turn on. Leave the room. If no occupancy is detected for 15 minutes, the lights will dim to minimum. In 5 more minutes, the lights will turn off. S ORDERING Lights will not turn on: (LED flashes with body motion) 1. Press the Auto/Off button to the auto position. 2. Check all wire connections. 3. For technical support call 1(800)879-8585. Lights will not turn on: (LED does not flash) 1. Make sure the main circuit breaker is on. Note: Whenever the main power is restored to the switch, the occupancy sensor charges and may take up to one minute to function properly. 2. Check all wire connections. 3. For technical support call 1(800)879-8585. WD-270 and WD-280 INFORMATION WD-270 Dimmable PIR Wall Switch; 120VAC, 60Hz with Dim Before Disconnect WD-280 Dimmable PIR Wall Switch; 277VAC, 60Hz with Dim Before Disconnect ASP-211* Cover plate for single gang box ASP-422 Blank cover plate for 2-gang box ASP-432 Switch option cover plate for 2-gang box Dimmable PIR Wall Switch with Dim Before Disconnect Add -W for White, -I for Ivory, -G for Gray, -B for Black, or -A for Almond. * One ASP-211 is included with each sensor. Lights will not turn off: 1. There is a 15 minute primary time delay after occupancy was last detected before the lights dim to the minimum level. The lights will then turn completely off after a secondary time delay elapses (user adjustable from 5 to 60 minutes) if no occupancy is detected during this time. 2. To test if unit is operating properly, set dimming slider to maximum light level and move out of the sensor’s view. Lights should go to minimum dimming level after 15 minutes, and then turn off after the secondary time delay elapses. 3. For technical support call 1(800)879-8585. S WARRANTY INFORMATION The Watt Stopper®, Inc. warranties its products to be free of defects in materials and workmanship for a period of five years. There are no obligations or liabilities on the part of The Watt Stopper, Inc. for consequential damages arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation or reinstallation. SSPECIFICATIONS Voltage: WD-270 . . . . . . . . . . . . . . . . . . . . . . . 120VAC, 60Hz WD-280 . . . . . . . . . . . . . . . . . . . . . . . 277VAC, 60Hz Load Rating: @120VAC . . . . . . 10–500W ballast or incandescent load @277VAC . . . . . . . . . . . . . . . . 10 –500W ballast load Tungsten: . . . . . . . . . . . . . . . . Dims incandescent lamps Ballasts: . . . . . . . . . . . . . . Use with Advance® Mark X™ or Philips Ecotron® electronic dimming ballasts (line voltage forward phase-cut dimming ballasts) Dimmer Adjustment: . . . . . . . . . . . . . . . . . 5% –100 % Primary Time Delay: to lights dimmed. . 15 min. (fixed) Secondary Time Delay: to lights off . . 5–60 min. (adjustable) Sensing motion outside detection areas: • Opaque adhesive tape is included with the sensor and can be used to limit the detection areas. See “Masking the lens”. IMPORTANT: Rapid successive pressing of the Auto/Off button will cause a delay in proper function. 5. Adjust the Secondary Time Delay to the desired setting (clockwise increases time). For most applications, about 15 minutes is recommended. 6. Align wide holes on metal bracket with holes in wall box and secure switch with provided screws. 7. Install cover plate to switch assembly with provided screws. Putting a Stop to Energy Waste ® 8. Push the Auto/Off button to the auto position to turn lights on. ✆ Call (800) 879-8585 For Technical Support ✆ All information in this drawing is the property of The Watt Stopper Inc. and cannot be copied or used without the written approval of The Watt Stopper Inc. REV. DESCRIPTION 1 ECO# 032698-1 FOUR-FOLD: 2800 De La Cruz Boulevard, Santa Clara, CA 95050 USA Technical Support: 1(800)879-8585 1(972)578-1699 86-0496-00 3/98 REV. DATE APPROVED FLAT SIZE: FOLDED SIZE: MATERIAL: INK COLOR: 11.5" x 5.5" 2.875" (2-7/8") x 5.5" 80# BOOK, White, Glossy BLACK Drawn by: HUCKABONE Drwg Date: 31 MAR 98 Santa Clara, CA 95050 1(800)879-8585 1(972)578-1699 the U.S.Patents: 4,787,722 4,874,962 5,124,566 5,640,113 Installation Instructions SADJUSTMENTS Watt Stopper Inc. SANTA CLARA, CALIFORNIA Title: WD-270 & WD-280 Installation Instructions Marketing: Engineering: Sheet: Scale: 1 of 2 1 : 1 Drawing # 86-0496-00 Original Drawing Date Rev # 31 MAR 98 1 S COVERAGE PATTERNS S INSTALLATION The WD-270 and WD-280 will cover up to 300 sq ft. The recommended coverage for typical desktop activity is 150 sq ft. The sensor has a two-tiered, multi-cell viewing Fresnel lens with a 180° field of view. The WD-270 and WD-280 have a dim-before-disconnect feature. The sensors feature a hard, vandal resistant lens which allows them to be used in a wide range of applications, including public spaces. ≠CAUTION≠ 1. Make sure that power has been turned off at circuit breaker. 2. Connect leads to sensor with UL listed wire connectors (BLACK to line, GREEN to ground, RED to load). 25' S OPERATION 3. Do not attach switch to wall box at this time. See “Adjustments” first. The WD-270 and WD-280 sensors turn lights on when a person enters the controlled area. Lights turn on to the level set with the dimming slider. The dimming slider does not turn the lights off, it allows users to increase or decrease the light level. The lights can be manually turned off at any time by pressing the Auto/Off button. THE GROUND MUST BE TIGHTLY SECURED OR THE SENSOR WILL NOT WORK ! TURN POWER OFF AT CIRCUIT BREAKER BEFORE WIRING SWITCHES. ALWAYS FOLLOW PROPER PRECAUTIONS WHEN WORKING WITH OR NEAR HIGH VOLTAGE. The switches work with the Advance® Mark X™or Philips Ecotron® electronic dimming ballasts (ballasts that have line voltage forward phase-cut dimming control). The WD-270 also works with incandescent fixtures. Wall box Neutral Neutral 10' Ground GRN Hot BLK Load RED Ground GRN Hot BLK Load The lights remain on while the space is occupied. Once the space is vacated, there is a 15 minute fixed time delay, after which the lights dim to the minimum light level. Then, after a secondary adjustable time delay of 5 to 60 minutes (set during installation) elapses, lights turn off. ±WARNING± The WD-270 and WD-280 switches can be connected to single or multiple loads from 10 to 500 watts. Load DESCRIPTION The Watt Stopper’s WD-270 and WD-280 are dimmable passive infrared wall switches that turn lighting systems on and off based on occupancy in the controlled area. A dimming slider adjusts the light level from minimum to maximum. Load S UNIT WD-270 or WD-280 Load RED 4.0' Cover plate ASP-211 floor 25' Masking the lens ✆ Call (800) 879-8585 For Technical Support ✆ Opaque adhesive tape is supplied so that sections of the sensor’s view can be masked. This allows you to eliminate coverage in unwanted areas. Since masking removes bands of coverage, remember to take this into account when trouble-shooting coverage problems. Single-Level Wiring Manual Bi-Level Wiring ✆ Call (800) 879-8585 For Technical Support ✆ the Watt Stopper Inc. SANTA CLARA, CALIFORNIA Title: WD-270 and WD-280 Installation Instructions Drawn by: All information in this drawing is the property of The Watt Stopper Inc. and cannot be copied or used without the written approval of The Watt Stopper Inc. Drwg Date: Sheet: HUCKABONE 31 MAR 98 2 of 2 Scale: 1 : 1 Drawing # 86-0496-00 Original Drawing Date Rev # 31 MAR 98 1