Download Sorensen ASD Series 10–320 kW 40–60 Vdc 167–8000 Adc

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Power factor wikipedia , lookup

Decibel wikipedia , lookup

Power over Ethernet wikipedia , lookup

Electric power system wikipedia , lookup

Control system wikipedia , lookup

Electrification wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Electrical ballast wikipedia , lookup

Nominal impedance wikipedia , lookup

Audio power wikipedia , lookup

Ohm's law wikipedia , lookup

Electrical substation wikipedia , lookup

Power engineering wikipedia , lookup

Power inverter wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Three-phase electric power wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Islanding wikipedia , lookup

History of electric power transmission wikipedia , lookup

Power MOSFET wikipedia , lookup

Current source wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Surge protector wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Schmitt trigger wikipedia , lookup

Rectifier wikipedia , lookup

Stray voltage wikipedia , lookup

Voltage regulator wikipedia , lookup

Alternating current wikipedia , lookup

Voltage optimisation wikipedia , lookup

Buck converter wikipedia , lookup

Opto-isolator wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
Sorensen ASD Series
10–320 kW
40–60 Vdc
Programmable Precision High Power DC Power Supply
167–8000 Adc
• Highest Power Density: 30kW in 3U
• Water-Cooled
• Full Digital Control Loops
380
- Stable operation over wide range of complex
load impedances
400
480
• Advanced Digital Features
- “Flight data” recorder-like function
- Oscilloscope function
- Output impedance measurement
- Advanced fault detection
- PLC feature: close loop on external
variable such as temperature
The ASD with DaVinci Power™ technology
represents the next generation of precision
programmable AC-DC power conversion.
The ASD with its 3U, 30kW water-cooled packaging
provides the highest power density available. The
ASD is designed for industry leading load transient
response with outstanding output ripple and noise.
The water-cooling packaging allows for use in
environments that normally exclude air-cooled power
supplies.
The ASD advanced digital architecture, with realtime digital control and Graphical User Interface
(GUI), enables many features to better control and
monitor your process or application. The optional
advanced features package includes a built-in
oscilloscope function for measurement and display
of: power, voltage, current, output impedance, output
cable impedance and output cable voltage drop. The
ASD allows you to program different “fault levels”,
enabling detection of output cabling, connections
or load problems before they cause critical system
problems. The ASD can replace your PLC device
by closing the loop on an external parameter such
as temperature. The ASD’s Advanced Diagnostics
And Maintenance (ADAMsm) feature includes a flight
data recorder feature that lets you access multiple
recorded parameters, such as: voltage, current,
power, load impedance, faults and input voltage.
This allows you to easily determine “why” you had
an unexpected outcome.
The advanced digital monitoring and control features
combined with industry leading power density and
reliability makes the Sorensen ASD the supply of
choice for stringent and high value processes and
applications.
(Modbus-TCP) (Modbus-RTU)
• Precise programming of voltage and current slew
rate for sensitive loads.
• Modules within one chassis can be connected to
different loads and controlled independently.
• Industrial field bus interface (Modbus-TCP,
Modbus-RTU, Ethernet/IP (Industrial Protocol))
enable real-time digital control.
• Built-in energy meter calculates the delivered
energy throughout a process or period of time.
• Optional real time clock enables accurate
timestamping of events.
• Built in power quality monitoring detects and
saves input voltage anomalies which can be saved
for later diagnostic analysis.
• Programmable analog interface scaling facilitates
incorporating the ASD to existing systems with
minimal effort.
• Load impedance measurement, including rate-ofchange calculations, enable load “state of health”
monitoring and implementation of system preventive
maintenance algorithms
• Programmable filter bandwidth of the output
voltage, current and power monitors let the user
accommodate their response speed to particular
needs.
• Full featured GUI (Graphical User Interface) helps
to test and debug the system by communicating
with the power supply in
real time
AMETEK
Programmable Power
9250 Brown Deer Road
San Diego, CA 92121-2267
USA
Advanced features include:
858.458.0223
[email protected]
10252013
75
ASD Series : Product Specifications
Input
Type: 3-phase, 3-wire plus ground, neutral not required. Not phase rotation sensitive
Voltage Ranges
342VAC to 440VAC (model D). Nominal rating is 380/400VAC.
432VAC to 528VAC (model E). Nominal rating is 480VAC
Frequency
Rated 47 through 63 Hz
Efficiency
>91% (typical), nominal line, full load.
Max Current, per phase, low line
400/380Vac
480Vac
10kW unit (1 module)
21Arms
17Arms
20kW unit (2 modules)
42Arms
33Arms
30kW unit (3 modules)
63Arms
50Arms
Current Inrush
200A Typical
Power Factor
>0.9 @ Full Load and at nominal line
Brownout Provisions
Designed to meet SEMI F47-0706, S3, S8, S14 at nominal input voltages
Output
Voltage Output
10kW
20kW
30kW
Noise (pk-pk)***
Noise (RMS)***
40Vdc
250A
500A
750A
150mV
40mV
60Vdc
167A
334A
501A
150mV
40mV
(*) Measured at the load terminals, with 1uF in parallel and 6ft of low-inductance load cable with supply operating at full load and nominal input line voltage.
(**) RMS noise is measured directly across the output terminal with supply operating at full load and nominal input line voltage.
(***) Value is for 30kW, single voltage models. Other variations may increase value by 2x.
Sense
To compensate load cables voltage drop, units can generate 2% additional voltage at full scale of output voltage.
Output
Load Regulation (Specified at No load to Full load change, nominal AC input)
Voltage
0.1% of maximum output voltage/ current
Current
0.1% of maximum output voltage/ current
Line Regulation (Specified at ±10% of nominal AC input, constant load)
Voltage
0.05% of maximum output voltage/ current
Current
0.05% of maximum output voltage/ current
Transient Response
A 50% step load will recover to within 0.75% of original value within 1mSec
Stability
±0.05% of set point after 8 hrs. at fixed line, load and temperature. After 30min warm-up.
Analog Remote Programming
Voltage Accuracy
0.5% of full scale
Current Accuracy
1% of full scale
Power Accuracy
1.5% of full scale
Voltage Monitoring
0.5% of full scale
Current Monitoring
1% of full scale
Power Monitoring
1.5% of full scale
Programming range
0-10Vdc, 4-20mA
Output
76
Output Float
Units maybe put in series with the float limit of output terminals must be within ±150V of chassis potential
Parallel
Multiple units can be paralleled to form higher power systems. Chassis control loops are tied together so that resulting higher
power systems have the same transient response as a 30kW system. Control commands are only required to be sent to “master”
supply. Parallel supplies require a shielded CAT 5 cable (STP) and appropriate output wiring connections by the user.
Calibration
End user calibration is supported. All standard and digital calibration can be performed without removing covers.
Digital Control (Optional)
Ethernet (Modbus-TCP or Ethernet/IP), RS-485 (MODBUS-RTU)
Analog Control
All control signals are isolated from the outputs
www.ProgrammablePower.com
ASD Series : Product Specifications
10–320 kW
Advanced Digital Features (Requires Optional Digital Control):
Graphical User Interface
Graphical User Interface (Windows based) enables remote control and display of the supply operation including the a
dvanced features listed below:
Oscilloscope Function (125 Hz)
Up to two parameters; Voltage, current, output impedance, output cable impedance, output cable voltage drop, power delivered…
Data logging
Programmable update rate of 1 sec to 1000 sec (default 10 sec) with last 1000 points stored. Stored parameters include, output
voltage/current, programmed set points, input voltage, output impedance, cable impedance, total power deliver, power meter,
internal faults
System fault reporting
Outside of set point, output impedance (detection of cabling, connection or load problems)
Physical
30 kW
Width
19.00in (48.3cm)
20 kW
19.00in (48.3cm)
10 kW
19.00in (48.3cm)
Depth
30.00” (76.2 cm)
30.00” (76.2 cm)
30.00” (76.2 cm)
Height
3U - 5.22” rack mount (13.25 cm)
3U - 5.22” rack mount (13.25 cm)
3U - 5.22” rack mount (13.25 cm)
Weight
≤125 lbs (56.69 kg)
Shipping Weight
Contact factory for more product & shipping weights
Mounting provisions
EIA rack-mount with slide provisions. Recommended rack slide: Jonathan slide, P/N 370EZ-28
AC Input Connector
Phoenix Contact terminal block
Protective Ground
1/4-20 stud
Output Connectors
bus bars with 3/8-16 inserted PEM nuts
Water Connections
3/8-18 NPTF hex bulkhead
Ambient Temperature
0 to 50ºC
Humidity
Relative humidity up to 95%, non-condensing
Water cooling specifications
Flow
1.5 gpm nominal, 1.25gpm minimum, 1.75gpm maximum. Internal condensation must be prevented by ensuring that the
temperature of the coolant is sufficiently high compared with the ambient air dew point
Temperature
25ºC nominal, 20ºC minimum, 30ºC maximum
Maximum pressure
80 PSI
Pressure drop
typical 12 PSI @ 1.5gpm per chassis
Regulatory
Certified to UL/CSA 61010 and IEC/EN 61010-1 by a NRTL, CE Compliant, LVD Categories: Installation Category II: Pollution Degree 2; Class II Equipment: for Indoor Use Only.
Rack mount equipment requires proper enclosure provided in end use. EMC Directive, EN 61326:1998
Model Number Description
ASD
V1 - V2 - V3 ACin Option Option
Where V1, V2, V3 (2 characters)
indicate the individual module voltage levels:
• 40, for a 40V, 250A module.
• 60, for a 60V, 167A module.
• 00, for no module (empty slot).
ACin (1 character) indicates the AC input voltage:
• D, for 380/400Vrms line to line, nominal voltage.
• E, for 480Vrms line to line, nominal voltage.
858.458.0223
Option (2 characters) indicates
other optional features:
• AA, standard unit AC Real-time clock
(must include advanced digital feature package).
Option (2 characters) indicates the optional interface type:
• 2A, Advanced digital feature package including full isolated analog
interface and Ethernet (Modbus-TCP) or RS485 interface.
• 2G, Advanced digital feature package including full isolated analog
interface (SG-compatible) and Modbus-RTU (serial) inteface
• 1D, for SG-compatible isolated analog interface. No access to
advanced digital features or GUI. Serial port is available with
maintenance functions only.
[email protected]
77
ASD Series : Product Diagram
1.57
27.81
19.00
5.22
78
www.ProgrammablePower.com