* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download DIP SWITCH ADJUSTMENT Multifunction timer ZMR , ZMRS, ZMRV
Electrical ballast wikipedia , lookup
Electric power system wikipedia , lookup
Audio power wikipedia , lookup
Ground (electricity) wikipedia , lookup
Current source wikipedia , lookup
Power over Ethernet wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Power engineering wikipedia , lookup
Control system wikipedia , lookup
Three-phase electric power wikipedia , lookup
History of electric power transmission wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Electrical substation wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Schmitt trigger wikipedia , lookup
Power inverter wikipedia , lookup
Protective relay wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Power MOSFET wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Stray voltage wikipedia , lookup
Alternating current wikipedia , lookup
Distribution management system wikipedia , lookup
Surge protector wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Voltage regulator wikipedia , lookup
Buck converter wikipedia , lookup
Power supply wikipedia , lookup
Opto-isolator wikipedia , lookup
Voltage optimisation wikipedia , lookup
Multifunction timer ZMR , ZMRS, ZMRV, ZMRVS Serie 17,5mm with 1 or 2 changeover DIP SWITCH ADJUSTMENT ZMR, ZMRV : 1 2 3 4 5 6 Function Time 6 5 4 3 2 1 6 5 4 3 2 1 Delay-on operate* 0,05 - Delay-on release 0,5 5 4 3 2 1 5 4 3 2 1 6 Pulse-on operate* 6 Pulse-on release 15 - 300s Flasher beginning with pause* 4 3 2 1 Flasher beginning with pulse* 5 4 3 2 1 Watchdog 6 5 4 3 2 1 15 - 300 min. 3 2 1 0,5 - 3 2 1 0,5 - 10 min. 3 - 60 min. 10 h ZMRS, ZMRVS : 4 Delay-on operate* 5 6 0,05 - 1s 1 2 3 4 5 6 Delay-on release 0,15 - 3s 1 2 Pulse-on operate* 3 4 5 6 0,5 - 10s 1 2 3 4 5 6 The ZMR multifunction timers offers up to 11 selectable timing functions and 8 different timing intervals in one unit. The function and timing intervals can be adjusted with DIP switches on the front panel of the relay. The multi-function timer can operate on either AC or DC voltage using two separate connections. For a 230V AC power supply use the terminals A1/A2. For a 24V UC power supply use the terminals A3/A2. The green LED indicates the connection to the power supply. Timing commences with the connection of the power supply or contact controlled on terminals B1/B2 or voltage controlled on terminal B1. 60s 6 DESCRIPTION 3 - 5 Time control 10s 6 APPLICATION 1s Pulse-on release 1,5 - 30s 1 6 2 6 Watchdog 3 Flasher beginning with pulse* 4 Snap-on mounting using a standard DIN rail EN 50022. The unit is designed to allow side-by-side mounting, with an ambient temperature of < 60°C. 5 Flasher beginning with pause* 6 MOUNTING 3 - 60s 1 2 3 4 5 0,15 - 3 min. 1 2 4 3 5 0,5 - 10 min. 2 1 3 1,5 - 30 min. APPROVALS * Integrated function of immediate-contact is adjustable at devices with 2nd changeover (25-26/28) FUNCTION PART NUMBER 011201 011202 011203 011204 011301 011302 011303 011304 ZMR1 1 changeover, 0,05s - 10h contact controlled on B1/B2 ZMR2 2 changeover, 0,05s - 10h contact controlled on B1/B2 ZMRS1 1 changeover, 0,05s - 30min. contact controlled on B1/B2 ZMRS2 2 changeover, 0,05s - 30min. contact controlled on B1/B2 ZMRV1 1 changeover, 0,05s - 10h voltage controlled on B1 ZMRV2 2 changeover, 0,05s - 10h voltage controlled on B1 ZMRVS1 1 changeover, 0,05s - 30min. voltage controlled on B1 ZMRVS2 2 changeover 0,05s - 30min. voltage controlled on B1 Delay-on operate : Timing begins with the connection of the power supply. This is indicated by a flashing yellow LED. After set time has elapsed the output relay switches into ist working position. This is indicated by a permanent on yellow LED. This state will be set untill the supply voltage is disconnected. Should the power supply be disconnected during recovery time, the timer returns to its original state. This also applies if the supply is disconnected during the timing period. A1 (A3) / A2 16,26 Kontakt 15,25 A1 A3 A2 HSB Industrieelektronik Hans-Bördlein-Str. 10 97723 Reith Tel.: +49 9736 / 75759 - 0 Fax: +49 9736 / 75759 - 20 t t 18,28 Kontakt 15,25 15 16 18 [email protected] www.hsb-electronics.de 25 t time 26 28 HSB Industrieelektronik Multifunction timer ZMR , ZMRS, ZMRV, ZMRVS Serie 17,5mm with 1 or 2 changeover Delay-on release : Continious presence of the power supply (A1/A2 or A3/A2) is required for timing. Activation of the timing function on ZMR devices is accomplished by an external control contact which is connected to the terminals B1/B2. Activation of the timing function on ZMRV devices is accomplished by a control voltage which is connected to terminal B1.The output relay is set to its working position as long as the control contact is closed (on ZMR devices) or as long as a voltage is connected to B1 (on ZMRV devices). A permanent on yellow LED indicates that the output relay has its working position. Delay time beginns by opening the control contact or at a remove of the control voltage. Activity of delay time is indicated by a flashing yellow LED. The output relay switches into ist rest position after delay time has elapsed. Delay time will start again if the control will be retriggered. . A1 (A3) / A2 t t* Kontakt B1/B2 18,28 Kontakt 15,25 16,26 Kontakt 15,25 A1 B1 A3 15 t 25 time t* B2 A2 16 18 26 time to short A1 (A3) / A2 t t* Kontakt B1/B2 18,28 Kontakt 15,25 16,26 Kontakt 15,25 B1 A1 15 t 25 time t* B2 A2 16 18 26 time to short 28 Flasher beginning with pause : Timing begins with the connection of the power supply to the terminals A1/A2 (230VAC) or A3/A2 (24VUC). The timing cycle begins with a pause. After completion of the selected time t the output relay switches to ist working position. This will be indicated by the yellow LED which is located on the front panel. The output relay switches back to its rest position after time t has elapsed again. Switching between this two states of the output relay will repeat as long as the device is connected to its supply voltage. Should the power supply be disconnected during recovery time, the timer returns to its original state. This also applies if the supply is disconnected during the timing period. Flasher beginning with pulse : Identical with flasher beginning with pause but cycle beginns with pulse. 28 A1/A2 Pulse-on operate : Time t starts when the device is connected to its power supply on A1/A2 (230VAC) or on A3/A2 (24VUC). The output relay switches into its working position when the device is connected to its power supply and stays in working position until holding time t elapses. This is indicated by the yellow LED on the front panel. The output relay falls back to its rest position when holding time t has eleapsed. Should the power supply be disconnected during recovery time, the timer returns to its original state. This also applies if the supply is disconnected during the timing period. t t A1 A3 t 16,26 Kontakt 15,25 A1 A2 15 16 18 25 t time 26 28 Pulse-on release : Continious presence of the power supply (A1/A2 or A3/A2) is required for timing. Activation of the timing function on ZMR devices is accomplished by an external control contact which is connected to the terminals B1/B2. Activation of the timing function on ZMRV devices is accomplished by an control voltage which is connected to terminal B1. The output relay is set to its rest position as long as the control contact is closed (on ZMR devices) or as long as a voltage is connected to B1 (on ZMRV devices).Time t beginns to run when opening the control contact or at a remove of the control voltage. The output relay switches to its working position when time t beginns to run and stays there as long as time t has eleapsed. A permanent on yellow LED indicates that the output relay has its working position. The output relay switches into its rest position after time t has elapsed. Delay time will start again if the control will be retriggered. HSB Industrieelektronik Hans-Bördlein-Str. 10 97723 Reith Tel.: +49 9736 / 75759 - 0 Fax: +49 9736 / 75759 - 20 t t 15 25 t time A2 t t 16,28 Kontakt 15,25 A1 (A3) / A2 18,28 Kontakt 15,25 t t t 18,28 Kontakt 15,25 16 18 26 28 watchdog : Continious presence of the power supply (A1/A2 or A3/A2) is required for timing. Activation of the timing function on SMR devices is accomplished by an external control contact which is connected to the terminals B1/B2. Activation of the timing function on SMRV devices is accomplished by an control voltage which is connected to terminal B1. After first removal of control source (contact on SMR or voltage on SMRV devices) does time t start to run and the output relay switches to its working position. If control source won’t be applied again during time range t, then the output relay switches to its rest position. But if control source will be applied again during time range t, then does time t start to run again and the output relay stays in working position. If the control source is longer applied than time t, does that cause the output relay to switch to its rest position. If the control source will be removed during time range t, does that cause the output relay to stay at its working position while time t starts to run again etc. A 1 (A 3 ) / A 2 t t B1/B2 18 K o n ta k te 1 5 16 K o n ta k te 1 5 [email protected] www.hsb-electronics.de HSB Industrieelektronik Multifunction timer ZMR , ZMRS, ZMRV, ZMRVS Serie 17,5mm with 1 or 2 changeover Delay-on operate with immediate-contact : To activate immediate-contact function on ZMR devices, B1/B2 has to be bridged. To activate immediate-contact function on ZMRV devices, voltage has to be applied on terminal B1. Timing begins with the connection of the power supply. This is indicated by a flashing yellow LED. After set time has elapsed the output relay switches into ist working position. This is indicated by a permanent on yellow LED. This state will be set untill the supply voltage is disconnected. Should the power supply be disconnected during recovery time, the timer returns to its original state. This also applies if the supply is disconnected during the timing period. A1 (A3) / A2 t t 18 Kontakt 15 16 Kontakt 15 28 Kontakt 25 26 Kontakt 25 A3 A1 15 25 B1 A3 A1 Flasher beginning with pause (and immediate-contact) : To activate immediate-contact function on ZMR devices, B1/B2 has to be bridged. To activate immediate-contact function on ZMRV devices, voltage has to be applied on terminal B1. Timing begins with the connection of the power supply to the terminals A1/A2 (230VAC) or A3/A2 (24VUC). The timing cycle begins with a pause. After completion of the selected time t the output relay switches to ist working position. This will be indicated by the yellow LED which is located on the front panel. The output relay switches back to its rest position after time t has elapsed again. Switching between this two states of the output relay will repeat as long as the device is connected to its supply voltage. Should the power supply be disconnected during recovery time, the timer returns to its original state. This also applies if the supply is disconnected during the timing period. Flasher beginning with pulse (and immediate-contact): Identical with flasher beginning with pause but cycle beginns ZMRV ZMR B1 The output relay falls back to its rest position when holding time t has eleapsed. Should the power supply be disconnected during recovery time, the timer returns to its original state. This also applies if the supply is disconnected during the timing period. 15 25 A1/A2 B2 A2 A2 16 18 26 28 Pulse-on operate with immediate-contact : To activate immediate-contact function on ZMR devices, B1/B2 has to be bridged. To activate immediate-contact function on ZMRV devices, voltage has to be applied on terminal B1. Time t starts when the device is connected to its power supply on A1/A2 (230VAC) or on A3/A2 (24VUC). The output relay switches into its working position when the device is connected to its power supply and stays in working position until holding time t elapses. This is indicated by the yellow LED on the front panel. t t t 26 28 16 18 t 18 Kontakt 15 t t t t 16 Kontakt 15 28 Kontakt 25 26 Kontakt 25 ZMRV ZMR B1 A1 A3 15 25 B1 A3 A1 15 25 A1 (A3) / A2 B2 t t A2 16 18 26 28 A2 16 18 26 28 18 Kontakt 15 16 Kontakt 15 OPTION 28 Kontakt 25 Other timing ranges and voltages available upon request. 26 Kontakt 25 ZMRV ZMR B1 B2 A1 A2 A3 15 16 18 25 26 28 HSB Industrieelektronik Hans-Bördlein-Str. 10 97723 Reith B1 A3 A2 A1 15 16 18 25 26 28 Tel.: +49 9736 / 75759 - 0 Fax: +49 9736 / 75759 - 20 [email protected] www.hsb-electronics.de HSB Industrieelektronik Multifunction timer ZMR , ZMRS, ZMRV, ZMRVS Serie 17,5mm With 1 or 2 changeover TECHNICAL DATA DIMENSIONS 45 Supply Supply voltage 22,5 49 22,5 5 90 1 or 2 AgSnO2 2000 VA 400V AC 8A 30A 17,5 Contact Number of changeover : Contact material : Max. switching power AC : Max. switching voltage : Max. switching current : Max. starting current: symmetrical rail EN 50022 A1 A3 25 26 28 B1 LED, green LED, yellow X B2 A2 15 16 18 Operation indicators Supply voltage : Relay in working position : Drop-off time of switching element : Max. switching frequency : Mechanical contact life : 1,5 68 A1 / A2 : 230V AC +/- 15% A3 / A2 : 24V AC/DC +/- 15% Frequency range : 0 / 50 ... 60Hz Power consumption : max 0,8W bei 24V/DC 1VA at 24V/AC 6VA at 230V/AC Operation mode : continous Supply voltage influence : < 0,01% over voltage range Temperature influence : < 0,01%/°C Recovery time : > 100ms Repetitive accuracy : +/- 0,2% approx. 20ms 15Hz 30 x 106 CONNECTION DIAGRAM B1 - for voltage controlled ZMRV: Voltage range: 20 - 250 V AC/DC Min. bridging time : 50ms Wire size: Protection against accidentical contact: Mounting : Dimensions l x w x h : Weight : 24 V UC A2 25 16 18 26 28 N (-) B2 15 ZMRV: VDE 0106T.100 / VBG4 symmetrical rail DIN EN 50022 90mm x 17,5mm x 69,5mm 96g 24 V UC Connectors: - 25 ... + 60°C VDE 0435T.2021 any VDE 0435T.2021 4kV VDE 0110 group C 250 cross-head screw clamp M3,5 2 x 2,5mm² B1 A1 A3 230 V AC General data Ambient temperature : Climate resistance : Mounting position : Vibration resistance : Test voltage : Isolation group : 230 V AC ZMR: 20-250 VUC B1/B2 - for contact controlled ZMR: Voltage (internal) B1(+) / B2(-) : 5 V DC Min. bridging time : 10ms Max. load : 25 kOhm B1 A1 A3 15 25 TIME ADJUSTMENT A2 HSB Industrieelektronik Hans-Bördlein-Str. 10 97723 Reith Tel.: +49 9736 / 75759 - 0 Fax: +49 9736 / 75759 - 20 16 18 26 28 N (-) Selection of time range has to be chosen with DIP-switch on the front panel. Fine adjustment of time has to be done with potentiometer on the front panel. [email protected] www.hsb-electronics.de HSB Industrieelektronik