Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
CURRENT SENSORS REFERENCE DESIGN GUIDE Application Note This document describes several reference designs for current sensing applications with either conventional or planar IMC-Hall® sensors. The design solutions cover various current ranges (from 2 to 2000A) and conductor types (bus bar, PCB, cable). Also included is a quick selection guide for Melexis Hall effect current sensors, general magnetic design guidelines and information on ferromagnetic materials. CURRENT SENSORS REFERENCE DESIGN GUIDE TABLE OF CONTENTS CURRENT SENSOR TYPES.......................................................................................................................... 3 CONVENTIONAL HALL SENSORS ................................................................................................................... 3 PLANAR IMC-HALL® SENSORS .................................................................................................................... 3 CONVENTIONAL HALL SENSORS ............................................................................................................... 4 1.1 MAGNETIC DESIGN ............................................................................................................................. 5 1.1.1 Examples ................................................................................................................................. 5 1.2 QUICK SELECTION GUIDE ..................................................................................................................... 6 1.2.1 Main features .......................................................................................................................... 6 1.2.2 Option code and sensitivity range ........................................................................................... 6 PLANAR IMC-HALL® SENSORS .................................................................................................................. 7 2.1 IMC VERSIONS ................................................................................................................................... 8 2.2 MAGNETIC DESIGN ............................................................................................................................. 9 2.2.1 Magnetic field estimation (with shield) ................................................................................... 9 2.2.2 Magnetic field estimation (without shield) ............................................................................ 10 2.2.3 Dimensioning examples ......................................................................................................... 11 2.2.4 Conductor with neck-down.................................................................................................... 11 2.2.5 Shield design for very high currents ....................................................................................... 12 2.2.6 Canceling stray field without shield ....................................................................................... 12 2.2.7 Avoiding cross-talk without shield ......................................................................................... 12 2.3 QUICK SELECTION GUIDE ................................................................................................................... 13 2.3.1 Main features ........................................................................................................................ 13 2.3.2 Option code and sensitivity range ......................................................................................... 13 2.4 PCB DESIGN: GUIDELINE ................................................................................................................... 14 2.5 REFERENCE DESIGNS ......................................................................................................................... 15 2.5.1 PCB application, 2-10A range, multi-layer/multi-turn solution ............................................. 16 2.5.2 PCB application, 2-10A range, ferromagnetic shield solution................................................ 17 2.5.3 PCB application, 10-50A range .............................................................................................. 18 2.5.4 Bus bar application, 50-250A range ...................................................................................... 19 2.5.5 Bus bar application, 300-700A range .................................................................................... 20 2.5.6 Bus bar application, dual range 5A/200A .............................................................................. 21 2.5.7 Cable application, 10-100A range ......................................................................................... 22 FERROMAGNETIC MATERIALS ................................................................................................................ 23 3.1 SUPPLIERS ....................................................................................................................................... 23 3.2 FERROMAGNETIC SHIELDS .................................................................................................................. 23 3.2.1 Standard U-Shield.................................................................................................................. 23 3.2.2 Mechanical assembly ............................................................................................................ 24 3.3 FERROMAGNETIC CORES .................................................................................................................... 25 END-OF-LINE CALIBRATION .................................................................................................................... 26 3.4 INTRODUCTION ................................................................................................................................ 26 3.5 DIRECT SENSOR CALIBRATION.............................................................................................................. 26 3.6 MICRO-CONTROLLER LEVEL CALIBRATION .............................................................................................. 26 ADDITIONAL INFORMATION................................................................................................................... 27 CONTACT US .......................................................................................................................................... 27 REV012 Page 2 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE Current sensor types Melexis provides two types of current sensors suitable for a broad range of applications. Conventional Hall sensors These current sensors are sensitive to the magnetic field perpendicular to the chip surface. They are meant to be used in combination with a ferromagnetic core. In a typical application, the core is wrapped around the current-carrying conductor and concentrates the magnetic flux on a small air gap (typically 2-5mm) where the sensor is inserted. Pros Strong magnetic gain from the core Very robust against cross-talk Suitable for medium to very high currents Cons Performance limited by the core (geometry and material): saturation, hysteresis, frequency response and thermal drift Bigger footprint (size, weight) than solutions based on IMC-Hall® sensors Planar IMC-Hall® sensors Thanks to the patented integrated magnetic concentrator (IMC) technology, IMC-Hall® sensors are sensitive to magnetic fields parallel to the chip surface. Thus, the sensors can directly measure the current flowing in a bus bar or a PCB trace below the package, without the need for a core. Pros Sensitive to magnetic field parallel to the chip surface, for easy integration and low footprint IMC is made of amorphous magnetic material featuring very high permeability and very low hysteresis Magnetic gain from IMC Cons Requires magnetic shielding or specific design to avoid cross-talk and/or noise from external fields REV012 Page 3 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE Conventional Hall Sensors REV012 Page 4 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 1.1 Magnetic design For this type of application, the sensor is typically enclosed in the air gap of a ferromagnetic core (ring or square), wrapped around the current-carrying conductor. d d I I The magnetic field at the sensor position (in the center of the air gap), for a current I and a ferromagnetic core with air gap d, can be approximated as: Equation 1: Magnetic field estimation formula (with core). 1.1.1 Examples 1.68 3.5 5 REV012 MLX91207 DVK core A B@100A = 1.25 x 100 [A] / 1.68 [mm] = 74.4 [mT] required sensor sensitivity: S = 2000 [mV] / 74.4 [mT] = 26.9 [mV/mT] MLX91207 DVK core B B@200A = 1.25 x 200 [A] / 3.5 [mm] = 71.4 [mT] required sensor sensitivity: S = 2000 [mV] / 71.4 [mT] = 28 [mV/mT] Maglab C-core B@500A = 1.25 x 500 [A] / 5 [mm] = 125 [mT] required sensor sensitivity: S = 2000 [mV] / 125 [mT] = 16 [mV/mT] Page 5 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 1.2 Quick Selection Guide 1.2.1 Main features Sensitivity [mV/mT] *programmable Thermal sensitivity drift [ppm/°C] Thermal offset drift [mV] Non-linearity [%F.S.] Response time [µs] Bandwidth [kHz] Analog output PWM output Programmable Diagnostic functions Over/Under-voltage detection Broken-track detection Clamping Package Temp. range [°C] 91207 91209 5-45* 5-150* ±150 ±20 ±0.5 8 100 Yes Yes Yes ±150 ±10 ±0.5 3 250 Yes No Yes Yes Yes Yes SOIC-8 -40-125 Yes No No VA (SIP) -40-150 Table 1: Main features and specifications of conventional Hall effect current sensors. 1.2.2 Option code and sensitivity range Sensor MLX91207 MLX91209 Option code CAA-005 CAA-007 CAA-001 Sensitivity range [mV/mT] 15-45 (25) 5-20 (10) 5-150 (50) Table 2: Option code and sensitivity range of conventional Hall effect current sensors. REV012 Page 6 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE Planar IMC-Hall® Sensors REV012 Page 7 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 2.1 IMC versions IMC-Hall® sensors are available in 3 different versions/sizes (LF, HF and VHF) covering a broad range of sensitivities and magnetic field ranges. With its strong magnetic gain, the biggest IMC (LF) is ideally suited for applications with low currents, requiring high magnetic sensitivities (up to 700mV/mT). At the other end of the scale, the smallest IMC (VHF) can linearly sense strong magnetic fields up to ±60mT, for current sensing applications with very high power densities. Low Field (LF) High Field (HF) Very High Field (VHF) Figure 1: Sensitivity range of each IMC version. Figure 2: Linearity error [µT] vs. magnetic field [mT]. REV012 Page 8 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 2.2 Magnetic design 2.2.1 Magnetic field estimation (with shield) In a typical application, a U-shaped ferromagnetic shield is wrapped around the current conductor to protect the sensor from external fields and improve the overall robustness of the sensing solution. W H’ Melexis Sensor PCB Current Conductor Shield The most important dimension of the shield is the inner width. In this configuration, the magnetic field seen by the sensor for a current I and an inner width W can be estimated as: Equation 2: Magnetic field estimation formula (with shield). The current in the current conductor is generating a magnetic field around it. The ferromagnetic shield will guide the magnetic field lines such that a homogeneous magnetic field is generated in the U-shield between the two legs of the shield, as it is shown in Figure 3. Melexis Sensor Current Conductor Shield Figure 3: Magnetic field lines distribution in a typical application Based on these considerations, the following magnetic design rules are essential in order to insure optimal performances: 1. The current sensing module should respect the Ferromagnetic Shield – Current Conductor – Melexis Sensor order of components. 2. In order to have an increased signal-to-noise ratio and for the sensor to see a homogenous field, it should be mounted well inside the opening of the shield, where the field lines are quasi-parallel to each other (the field is homogeneous). One rule of thumb is that the REV012 Page 9 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE distance from the sensor to the upper side of the shield (H’) should be higher or equal to half the width of the shield (W): Typically, the shield thickness ranges between 0.8 and 1.5mm (proportional to current range). The height and depth are between 12 and 15mm, in order to properly surround the sensor in each direction. The recommended material is 50%NiFe (Supra50). 2.2.2 Magnetic field estimation (without shield) Depending on application environment and requirements, the ferromagnetic shield is not necessarily required. H W Without shield, the magnetic field seen by the sensor for a current I, a trace width W and a vertical position H can be approximated as: Equation 3: Magnetic field estimation formula (without shield). REV012 Page 10 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 2.2.3 Dimensioning examples The table below provides suggested system dimensions for various current ranges, based on a typical design with a sensor on top of a straight bus bar surrounded by a U-shaped ferromagnetic shield. These dimensions can be easily scaled up or down for higher or lower currents according to the magnetic field estimation formula provided above. Current [A] (peak) 250 500 1000 Shield geometry Width Thickness [mm] [mm] 12 0.8 12 1.5 25 1.5 Magnetic Field [mT] (peak) 25 50 50 Sensor Sensitivity Version [mV/mT] HF 80 VHF 40 VHF 40 Table 3: Typical system dimensions. Figure 4: Example of 3-phase inverter current sensing solution with IMC-Hall® sensors. 2.2.4 Conductor with neck-down In order to limit the cost, size and weight of the shield on systems with wide bus bars, we recommend reducing the cross-section locally, as illustrated on the example below. Such a neckdown has minimal impact on the electrical resistance and allows for a much more compact current sensing solution. ≈12 ≈18 ≈10 Figure 5: Necked-down bus bar illustration. REV012 Page 11 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 2.2.5 Shield design for very high currents For very high currents (typically above 800A), instead of the usual single sheet bent to form a “U”, it is often more efficient and cost-effective to use a laminated shield (made of a stack of thin sheets). That way, the in-plane thickness can be increased while decreasing the depth and overall footprint for the same performance. 2.2.6 Canceling stray field without shield In AC applications, external stray fields can be cancelled out by the microcontroller. Computing the difference between max and min sensor output values provides a signal independent of any parasitic DC field. 2.2.7 Avoiding cross-talk without shield Even without ferromagnetic shield, cross-talk between adjacent current tracks can be avoided by design. Figure 6 illustrates a concept of current trace layout with slots to force the current to flow perpendicular to the main track axis. The sensors are rotated by 90° with their sensitive axis (blue arrow) parallel to the current trace. With such a configuration, there is virtually no cross-talk between phases. Figure 6: Current trace layout with slots and rotated sensors to avoid cross-talk between phases. REV012 Page 12 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 2.3 Quick Selection Guide 2.3.1 Main features Sensitivity [mV/mT] (*programmable) Very High Field version High Field version Low Field version Thermal sensitivity drift [%] Thermal offset drift [mV] Non-linearity [%F.S.] Response time [µs] Bandwidth [kHz] Analog output PWM output Programmable Diagnostic functions Over/Under-voltage detection Broken-track detection Clamping Package Temp. range [°C] 91205 91206 91208 100 280 ±2 ±50 ±0.5 8 100 Yes No No 60-330* 200-700* ±1.5 ±20 ±0.5 8 100 Yes Yes Yes 30-200* 50-300* 100-700* ±1.5 ±10 ±0.5 3 250 Yes No Yes No No No SOIC-8 -40-125 Yes Yes Yes SOIC-8 -40-150 Yes No No SOIC-8 -40-150 Table 4: Main features and specifications of planar IMC-Hall® current sensors. 2.3.2 Option code and sensitivity range Sensor MLX91205 MLX91206 MLX91208 Option code AAL-003 AAH-003 CAL-001 CAL-002 CAL-003 CAH-001 CAH-002 CAH-003 CAH-004 CAL-000 CAH-000 CAV-000 IMC version LF HF LF LF LF HF HF HF HF LF HF VHF Sensitivity range [mV/mT] 280 100 460-700 (580) 300-470 (380) 200-310 (250) 210-330 (270) 130-220 (170) 80-140 (110) 60-110 (77.5) 100-700 (250) 50-300 (100) 30-200 (40) Table 5: Option code and sensitivity range of planar IMC-Hall® current sensors. REV012 Page 13 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 2.4 PCB Design: Guideline The PCB design and layout plays an important role in the final performances of the current sensing module. More specifically, two different aspects are to be considered when designing the ground layer on the PCB. When an application implies high voltage switching (for instance in motor control applications), an expanded ground layer, as depicted Figure 7:, will help reducing the parasitic coupling capacitance generated by dV/dt transients. Figure 7: Current sensing structure – Expanded Ground Layer on PCB in order to reduce the parasitic coupling capacitance (coming from dV/dt transients). At the same time, the ground layer can have a big impact on the response time. If the ground layer covers all the surface of the PCB and surrounds the two legs of the shield, Eddy currents will start to flow circularly around the legs of the shield, generating a counter-magnetic field which slows down the response time of the sensor. In order to avoid increased response time, the ground layer should be divided such that it interrupts the circulations of Eddy currents around the shield. Figure 8: Current Sensing Structure – Designing the Ground Layer on the PCB such that Eddy Currents circulations is interrupted REV012 Page 14 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 2.5 Reference Designs Application PCB trace current Solution Illustration Multi-turn and multi-layer PCB Single layer PCB with C-shaped ferromagnetic shield 2-10A PCB trace current 10-50A Bus bar 50-250A Bus bar 300-700A High dynamic range 50mA to 250A Non-intrusive current sensing from cable Single layer PCB with or without ferromagnetic shield High field sensor with 12mm Ushaped ferromagnetic shield Very high field sensor with 12mm U-shaped ferromagnetic shield Dual range sensor with U-shaped and C-shaped shields Simple PCB with clamp-on shield wrapped around the cable 10-100A Table 6: Overview of the reference designs based on planar IMC-Hall® current sensors. REV012 Page 15 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 2.5.1 PCB application, 2-10A range, multi-layer/multi-turn solution PCB with multiple layers and trace windings (current loops) for very high sensitivity. Can be used with or without ferromagnetic shield, depending on sensitivity and accuracy requirements. Figure 9: PCB layout example for very high sensitivity with 6 windings on 3 layers. Sensitivity (max) [mV/A] 3 windings w/o shield 210 3 windings w/ shield 350 6 windings w/o shield 420 6 windings w/ shield 700 Figure 10: Maximum achievable sensitivities with Melexis evaluation boards. 550mV/A 330mV/A Figure 11: Example of output functions for a six-winding evaluation board, with/without shield. REV012 Page 16 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 2.5.2 PCB application, 2-10A range, ferromagnetic shield solution PCB with one layer and a single current trace (no windings). Closed ferromagnetic shield for high magnetic gain. Assembly Concepts Figure 12: Shield in one piece inserted through slots on the PCB edge. Figure 13: Shield in two parts inserted in PCB slits and assembled together. 167mV/A Figure 14: Example of output function for a single-layer PCB with closed shield. REV012 Page 17 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 2.5.3 PCB application, 10-50A range PCB with one layer and a single current trace. To be used with or without ferromagnetic shield (U-shaped). Sensitivity: up to 60mV/A (without shield) and 170mV/A (with shield). Figure 15: Single-layer evaluation board without and with shield. Figure 16: Shield assembly through PCB slits. 65mV/A 40mV/A Figure 17: Example of output function for a single-layer PCB, with/without shield. REV012 Page 18 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 2.5.4 Bus bar application, 50-250A range The high field (HF) sensor on PCB is mounted directly above the conductor. A simple, low-cost and compact U-shaped shield is mounted around the sensor to protect it from stray fields and ensure good signal robustness against vibrations and displacements. With the dimensions demonstrated here, the linearity error is lower than ± 1.5A up to ±250A. Figure 18: Demonstrator based on MLX91206 HF sensor and U12 shield with 0.8mm thickness. Figure 19: Shield dimensions. 20mV/A Figure 20: Typical output and non-linearity of a sensor calibrated for ±100A. REV012 Page 19 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 2.5.5 Bus bar application, 300-700A range With the very high field (VHF) sensor, the measurement range can be extended to 700A while keeping the same inner width than for the previous design (12mm). Only the shield thickness must be adapted from 0.8 to 1.5mm. The linearity error is lower than ±5A up to ±650A. Very compact solution to measure 700A with a footprint of less than 2cm2. 12 1.5 Figure 21: Demonstrator based on MLX91208 VHF sensor and U12 shield with 1.5mm thickness. Figure 22: Sensor output and linearity error versus current. REV012 Page 20 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 2.5.6 Bus bar application, dual range 5A/200A Solution for applications with a wide dynamic range. One sensor with C-shaped (closed) shield for high accuracy at small currents (typ. ±5A). One sensor with U-shaped shield for high saturation limit (typ. ±200A). Other combinations of ranges are possible depending on the application requirements. ±5A range View ±200A range Dimension [mm] thickness = 0.8mm S=400mV/A 20-25mA accuracy S=10mV/A 200mA accuracy Figure 23: Typical output of the 5A and 200A range sensors. REV012 Page 21 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 2.5.7 Cable application, 10-100A range The clamp-on shield gathers the magnetic field around the cable and concentrates it above the sensor package. Small air gap ensures high magnetic gain. Shield geometry can be adapted to match various cable diameters and current ranges. Figure 24: Cable clamp concepts (left: monolithic shield, right: two-part shield in plastic housing). Figure 25: Implementation examples (monolithic and two-part shield in plastic housing). 50mV/A Figure 26: Example of output function with a cable-clamp demonstrator calibrated for ±40A. REV012 Page 22 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE Ferromagnetic materials 3.1 Suppliers Melexis partnered with magLab and PML India for ferromagnetic material supply. www.maglab.ch www.pmlindia.com Recently, PML and magLab signed an exclusive collaboration in the field of contactless current sensing. This cooperation between magLab and PML offers an efficient and cost-effective solution for customers requiring magnetic shields. magLab takes care of the engineering side, while PML manufactures the products to our specifications. 3.2 Ferromagnetic shields 3.2.1 Standard U-Shield Figure 27: Ordering information for the standard U-shield from MagLab. REV012 Page 23 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 3.2.2 Mechanical assembly Ferromagnetic shields can be assembled by crimping, screwing or bonding (glue or tape). They can also be encapsulated in a pre-molded plastic case. The optimal solution depends on the application. In any case, care should be taken to avoid mechanical stress on the part of the shield involved in the magnetic measuring circuit. Figure 28: Several solutions for shield assembly. One of the most common solutions is to use a pre-molded plastic case, with slots to insert the shields, as illustrated on the pictures below. Figure 29: Assembly with pre-molded plastic case. REV012 Page 24 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE 3.3 Ferromagnetic cores The performance of the current sensing solution relies on the careful selection of a proper core geometry, material and manufacturing conditions (annealing, lamination, etc.). Table 7 displays the main features of the most common material types. Material type Saturation Speed Price Ferrite 0.5T Fast $ Silicon Iron (SiFe) 1.6T Medium $$ Nickel Iron (NiFe) 1.4T Fast $$$ Table 7: Features of most common ferromagnetic core materials. Figure 30 shows the linearity and hysteresis of 3 geometrically identical cores made of the most common ferromagnetic materials, for comparison purposes. Figure 30: Linearity error and hysteresis of the most common ferromagnetic core materials. REV012 Page 25 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE End-of-line Calibration 3.4 Introduction Each current sensor is individually tested and calibrated over temperature on the Melexis production line. However, in order to achieve optimal accuracy, a final calibration is required at customer-side after assembly to compensate for mechanical tolerances (sensor position deviations, shield dimensions, etc.) This final calibration can be done in two ways: either by using the Melexis tools to directly program the sensor EEPROM, or by adjusting the gain/offset at microcontroller level. 3.5 Direct sensor calibration All recent current sensor products (starting from MLX91206) can be programmed using the Melexis universal programmer (PTC-04) and related software. The PTC-04 communicates with the sensor through 3- or 4-wire connectors, and with the PC through USB or RS-232. Melexis provides a library of sensor-specific high level functions (.dll), which can be used to develop custom software using common programming language (C/C++, Labview, etc.) The calibration is a fast two-step process: the sensor output function (gain and offset) is adjusted automatically based on two reference measurements (i.e. zero current and nominal current). 3.6 Micro-controller level calibration A micro-controller level correction is recommended for multi-sensors applications, i.e. on power distribution units, where typically 12 to 24 sensors are on the same PCB in order to monitor the current of each channel. All Melexis current sensors are factory calibrated over temperature. After assembling of the factorycalibrated sensors on each channel, a reference current is applied on each channel. The output voltage of each sensor is measured and the required corrective factor is thus calculated and stored in the microcontroller. REV012 Page 26 of 27 Aug-16 CURRENT SENSORS REFERENCE DESIGN GUIDE Additional Information Please refer to the following documents for additional information on specific topics: Design guide for low currents http://melexis.com/Assets/Small-Currents-Design-Guide-6252.aspx Design guide for high currents http://melexis.com/Assets/High-Currents-Design-Guide-6253.aspx Power distribution units (PDU) applications http://melexis.com/Assets/Current-Sensors-Deployment-in-PDU-(Power-Distribution-Unit)Applications-6092.aspx Magnetic linearity and hysteresis Application note focusing on the magnetic performance of Hall sensors and ferromagnetic materials. http://melexis.com/Assets/Magnetic-linearity-and-hysteresis-6477.aspx Contact Us Please contact our current sensor team for more information. Amalia Spataru ([email protected]) Simon Houis ([email protected]) Robert Racz ([email protected]) REV012 Page 27 of 27 Aug-16