Download Goniometer Spirometer Breath Rate

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Document related concepts

Myocardial infarction wikipedia , lookup

Cardiac surgery wikipedia , lookup

Electrocardiography wikipedia , lookup

Antihypertensive drug wikipedia , lookup

Quantium Medical Cardiac Output wikipedia , lookup

Dextro-Transposition of the great arteries wikipedia , lookup

Transcript
PASCO
Physiology Sensors
Goniometer
Spirometer
Breath Rate
PS-2137
PS-2152
PS-2187
P Accurately
measures joint
movements
P Flexible
mounting
options
Measure airflow and lung volume. Disposable
mouth pieces available for student safety.
The Goniometer can be connected to the
knee, hip or elbow joints. Measure the
angular position, velocity and
acceleration for the arm or leg.
The sensor includes one
Goniometer
Probe and
Velcro™
connection kit.
To measure the
motion of two
joints simultaneously,
purchase another
Goniometer Probe
separately.
Typical Applications:
C ompare a student’s airflow before and
after exercise
Investigate the lung volume of
athletes vs. non-athletes
Specifications
Displays volume in liters
Minimal resistance to air flow
Bi-directional air flow
Sample Rate Range: 50 to 100 Hz
The Breath Rate Sensor uses standard
disposable dust masks and gives stable
output even when exercising. Breath rate is
measured by sensing the pressure changes
inside the mask. Tubing from the sensor connects to the disposable pressure clips which
fasten on the side of the mask.
Two Modes:
One reading every breath
Running average over last four breaths
Specifications
Range: 0 to 120º
Accuracy: 2% of measurement
Resolution: 0.25º
Maximum Sample Rate: 500 Hz
Data collected with Xplorer
GLX while exercising.
Position and velocity
of knee joint while
running.
Measuring lung
capacity.
Includes:
Sensor with Tubing
Pressure Clips (10)
Masks (10)
Developed in
cooperation with
Nancy Beverly,
Assistant
Professor of
Physics at Mercy
College, Dobbs
Ferry, New York.
Replaceable
mouthpiece
clips in.
Order Information:
Goniometer Sensor........ PS-2137
Recommended:
Additional
Goniometer Probe........... PS-2138
Xplorer GLX...................... PS-2002
56
p. 4
Order Information:
Order Information:
Spirometer Sensor....................................PS-2152
Breath Rate Sensor..................................PS-2187
Spirometer Mouth Pieces
(10-pack). .........................................................PS-2522
Replacement Clips (10).........................PS-2568
www.pasco.com/engineering
Replacement Masks (10).....................PS-2567
Physiology Sensors
EKG
Hand Grip Heart Rate
PS-2111
PS-2186
The EKG Sensor measures electrical signals
produced by the heart. As cardiac muscle
depolarization and repolarization occurs,
the EKG trace graphically illustrates the beating of the heart. The sensor comes with 100
self-adhesive conductive patches that are
easily removed from the skin after use.
Typical Applications:
enerate a personal EKG graph
G
Compare EKG graphs before and after mild
exercise
Specifications
EKG Waveform:
Voltage: 0 to 4.5 mV
Resolution: 4.5 µV
Sample Rate: 50 to 200 samples per second (sps)
Default Sample Rate: 200 samples per second (sps)
Heart Rate (Beats):
Range: 47 to 250 beats per minute (bpm)
Resolution: 1 beat per minute (bpm)
The Hand Grip Heart Rate Sensor allows
students to measure heart rate without
the restriction and inconvenience of belts
or clips. Extra long cords allow students
to freely increase their physical activity
in order to determine exercise heart rate.
Simply grip the handles while the sensor
measures cardiac muscle contraction in
beats per minute.
PASCO
Blood Pressure
PS-2207
With PASCO’s Blood Pressure Sensor
students easily measure heart rate (bpm),
systolic and diastolic arterial blood pressure
(mmHg). Students gain a greater understanding of the physiology of the circulatory
system when they also learn about the
physiology of blood pressure. The systolic
and diastolic pressure provided in the digits
display can be used by the student to verify
their own determination of blood pressure
from the graph.
Typical Applications:
P Biology Lab 10: Physiology of the Circulatory
A
System
Measure and compare resting, exercise and recovery
heart rate to determine physical fitness levels
Specifications
Measurement Range: 40-240 beats per minute
Time to acquire heart beat: 8-10 seconds
Typical LED Indicators:
Standby: handgrips not held
Acquire: acquiring heart beat
Beat: flashes with each beat
A student “patient” remains still while another student uses
the pump to increase the pressure in the cuff. The students
observe the graph as the pressure in the cuff slowly decreases. On the digits display, students observe the patient’s heart
rate, systolic and diastolic blood pressure.
Includes:
Blood Pressure Sensor, medium arm cuff*,
bladder and pressure
release valve.
NOTE: The EKG Sensor has been designed for educational
purposes only and is not suitable for medical diagnoses.
*small and large
cuffs are also
available
Additional EKG Electrode
Patches (CI-6620) may be
ordered separately.
Order Information:
Blood Pressure Sensor................... PS-2207
Recommended:
Small Cuff.......................................... PS-2531
Order Information:
EKG Sensor.....................................................PS-2111
Order Information:
Medium Cuff..................................... PS-2532
EKG Patches (100 each)........................CI-6620
Heart Rate Sensor.....................................PS-2186
Large Cuff.......................................... PS-2533
www.pasco.com/engineering
57