Download Panasonic KR20 High-Speed Wireless Unit

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Transmission line loudspeaker wikipedia , lookup

Rectifier wikipedia , lookup

Mains electricity wikipedia , lookup

History of electric power transmission wikipedia , lookup

Power over Ethernet wikipedia , lookup

Flip-flop (electronics) wikipedia , lookup

Wireless power transfer wikipedia , lookup

Invention of radio wikipedia , lookup

Buck converter wikipedia , lookup

Schmitt trigger wikipedia , lookup

Last mile wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Telecommunications engineering wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Opto-isolator wikipedia , lookup

Transcript
KR20 WIRELESS UNIT (AKR2)
High-speed,
wireless communication
with easy installation
and simple wiring!!
KR20
WIRELESS UNIT
FEATURES
Compliance with RoHS Directive
• High-speed data communications
(134kbps wireless)
Approximately 15 to 20 times faster
compared to low power wireless
communication devices (comparison by
our company) achieved and use for
purposes requiring high speed response
possible.
Examples: All measuring devices (control
panel, security alarm, temperature
monitor, electricity monitor, production
quantity monitor, etc.), 0.1 seconds or
less for sending and receiving data with
several dozens of bytes (approximately
1.5 seconds for the previous product)
• Reducing the wiring and installation
work
Wiring is unnecessary when the layouts
for machines and equipment frequently
change and in installation in locations
where wiring is difficult
Installation of the main unit on the board
and DIN rail attachment possible
• Common units for master and slave
• Easy-to-operate main unit and
setting tool software
• Wireless repeater function
The communication distance of wireless
devices (between the master and a
remote) is approximately 250 m outdoors
in an open location (approximately 50 m
indoors). Since the repeater function is
also incorporated in this unit, the
communication distance can be extended
by adding products for use as repeaters
between the master and remote. (Up to 8
units can be installed between the master
and remote.)
• Up to 99 wireless remote units can
be connected for one master wireless
device
Co-existence of RS485 and I/O type is
also possible. However, only when using
1:N communication and MEWTOCOL
(communication protocol for our
company’s PLC).
PRODUCT TYPES
Main unit
Product name
KR20 WIRELESS UNIT RS485 type
KR20 WIRELESS UNIT I/O type (NPN)
KR20 WIRELESS UNIT I/O type (PNP)
Descriptions
Model number
AKR2002
AKR2015
AKR2045
RS232C, RS485
I/O: 8/8 (NPN), RS232C
I/O: 6/6 (PNP), RS232C
Notes: 1. A power supply cable (1 m) for the main unit is supplied with this product.
2. Antenna is not attached. Select from optional supplies.
Options
Product name
Standard antenna
Antenna with cable
Antenna extension cable
Power supply cable for FPΣ*
Power supply unit for FP0
Descriptions
2 pieces
2 pieces, 2 m length
Special order, 2 pieces, 2 m length
1 piece, 1 m length
Input: 100 to 240V AC, Output: 24V DC, 0.7A
Model number
AKR2802
AKR2803
AKR2804
AFPG805
AFP0634
Notes: 1. Two antennas and two antenna extension cables are required per main unit.
2. A magnet and double-sided tape are supplied with antennas with cable for fitting
3. When an antenna extension cable is used, the communication distance becomes short.
*Included with product
Setting software
Product name
Control Configu ator KR
Descriptions
Remarks
Setting tool for KR20 wireless unit
You can download from our website (free of charge)*
Use the tool Ver. 1.20 or later for KR20.
Descriptions
Detailed explanation of KR20 WIRELESS UNIT usage (pdf)
Remarks
You can download from our website (free of charge)*
Manual
Product name
KR20 WIRELESS UNIT User’s manual
* Customer registration is required to download data.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
KR20 WIRELESS UNIT (AKR2)
SPECIFICATIONS
General specifications
Specifications
Item
Rated voltage
Operating voltage range
Current consumption
Inrush current
Ambient temperature
Storage temperature
Ambient humidity
Storage humidity
Breakdown voltage (initial)
Insulation resistance (initial)
Vibration resistance
Shock resistance
Noise immunity
Overcurrent protection of power supply
Weight
RS485 type
I/O type
12 to 24V DC
10.8 to 26.4V DC
150mA or less (During sending)
200mA or less (During sending)
23A (when 24V DC)
–10 to +50°C
–20 to +70°C
30 to 85%RH (at 25°C non-condensing)
30 to 85%RH (at 25°C non-condensing)
500V AC for 1 min.
(Between power terminal and FG/DSUB connector,
Between power terminal and input/output terminal,
Between input terminal and output terminal)
100MΩ or more (at 500V DC)
100MΩ or more (at 500V DC)
(Between power terminal and FG/DSUB connector,
(Between power terminal and FG/DSUB connector)
Between power terminal and input/output terminal,
Between input terminal and output terminal)
10 to 55Hz 1cycle/min. Double amplitude of 0.75mm, 10min. on 3 axes
98m/s2 or more, 4 times on 3 axes
1000V [p-p] with pulse width 50ns, 1 µs (based on in-house measurements) (Power terminal)
Fuse (Rated current: 3.15A)
Approx. 160g
500V AC for 1 min.
(Between power terminal and FG/DSUB connector)
Wireless specifications
Item
Wave type
Transmission distance
Wave output
Frequency
Number of channels
Number of channels in same transmission area
Transmission speed
Communication style
Repeater function
Response time
Specifications
RS485 type
Direct sequence spread spectrum (DS-SS)
Approx. 250 m outdoors* (straight, obstacle-free distance), Approx. 50 m indoors
6mW/MHz or less
2403.328MHz to 2480.128MHz
76ch (Select with communication channel switch)*1
15 channels recommended (when select fixed channel)*2
134kbps
1: N topology (N: 99 units max.)
8 repeaters (Between master and slave)
OFF → ON
—
ON → OFF
I/O type
Max. 80ms*3
Note: The main unit, standard antenna and antenna with cable are designed for indoor use.
If they are used outdoors, then take water-proof measures such as using plastic cases, etc.
Serial communication specifications (RS232C) *4
Item
Interface
Transmission distance
Transmission speed
Communication method
Synchronous system
Transmission format
Data buffer
Specifications
Conforming to RS232C
15m
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bit/s (Selectable with MODE switch)
Half-duplex
Synchronous communication method
Stop bit: 1 bit, Parity: Not available/Available (odd/even), Data length: 7bit/8bit
2048 bytes (Max. data byte size for send and receive one time)
Serial communication specifications (RS485) (only AKR2002) *4
Item
Interface
Transmission distance
Transmission speed
Communication method
Synchronous system
Specifications
Conforming to RS485
1200m
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bit/s (Selectable with MODE switch)
Half-duplex
Synchronous communication method
Transmission format
Data buffer
Ending resistance
Number of connected units
Stop bit: 1 bit, Parity: Not available/Available (odd/even), Data length: 7bit/8bit
2048 bytes (Max. data byte size for send and receive one time)
Approx. 120Ω (built-in) (Terminal “E” and terminal “–” are shorted when ending.)
Max. 31
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
KR20 WIRELESS UNIT (AKR2)
Input specifications (only AKR2015 and AKR2045)
Specifications
AKR2015 (Output NPN type)
Input impedance
Operation indicator
Output specifications (only AKR2015 and AKR2045)
Item
Insulation method
Output type
Rated load voltage
Allowable load voltage range
Max. load current
Max. inrush current
Points per common*5
Off state leakage current
On state voltage drop
External power supply
(+, – terminal)
Voltage
Current
Surge absorber
Operation indicator
Specifications
AKR2015 (Output NPN type)
AKR2045 (Output PNP type)
Optical coupler
Open collector (NPN)
Open collector (PNP)
12 to 24 V DC
10.8 to 26.4 V DC
0.3A
1.5A
9 points/common
7 point/common
(Signal output,
(Signal output,
Communication error output)
Communication error output)
1 µA or less
1.5 V DC or less
—
10.8 to 26.4V DC
—
Max. 60mA
Zener diode
LED display (green)
6 points/common (Either positive or negative of input power
supply can be connected.)
Input circuit diagram
Input
Internal circuit
Internal circuit
Points per common*5
AKR2045 (Output PNP type)
12 to 24V DC
COM
Output circuit diagram AKR2015 (NPN)
Output
Internal circuit
Optical coupler
12 to 24 V DC (voltage input)
10.8 to 26.4 V DC
Approx. 3mA/when 12 V, Approx. 6mA/when 24 V
8 points/common (Either positive or negative of input power
supply can be connected.)
Approx. 4kΩ
LED display (green)
Load
12 to 24V DC
COM (0V)
Output circuit diagram AKR2045 (PNP)
+
12 to 24V DC
Output
Load
–
Restriction of input number and output number of
simultaneously ON
Input number and output number should be in the range of the blow according
to the ambient temperature.
AKR2015
No. of points per
common which are
simultaneously on
Insulation method
Rated input voltage
Operating voltage range
Rated input current
8
4
40 50
Ambient temperature (°C)
AKR2045
No. of points per
common which are
simultaneously on
Item
6
4
40 50
Ambient temperature (°C)
Functions specifications
Item
Setting function
Test function
LED display
Specifications
RS485 type
I/O type
• Operating mode change (SET, RUN, TEST)
• Serial communication setup (MODE switch)
• Communication channel change (CH switch)
• Slave registration
• Unit No. change (UNIT No. switch)
• Initializing (Factory setting)
—
Data holding (When communication error)
Communication test: 3-stage LED display (With setting tool, it can do various communication tests such as changing data amount,
including repeaters and so on. And it can measure an approximate communication time.)
Field intensity monitor: 3-stage LED display (With setting tool, it can display and record a field intensity of each channel by numeric value.)
• Distinguish master or slave (MASTER)
• Error, Alarm, Caution (ALARM)
• On communication, Power on (COM.)
• Level indication (1, 2, 3: when using test function)
• On setting, Complete setting (SET)
—
I/O operating display (16 or 12 points + 1 point of communication error)
Notes: *1. Adding to the fixed channel, 76ch (00 to 4B), 89 group channel can be selected.
Group channel is the function that it selects connectable channel from several fixed channels automatically. When using repeater function, use with the fixed
channel.
When using group channel, settable channel numbers are decreased in the same communication area and the communication time becomes longer.
*2. It is different according to the mounting conditions, when several channels are used in the same communication area, communication error might occur due to
interference radio wave.
*3. There are no error without serial communication at 1:1 topology.
Response time: Time from input signal to input terminal to output from output terminal in connected equipment
When input signal is shorter than response time, there is a possibility not to transfer to output side.
*4. RS232C and RS485 are not used in the same time.
*5. In case simultaneously ON of input and output, input number and output number are restricted according to the ambient temperature.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
KR20 WIRELESS UNIT (AKR2)
SYSTEM CONFIGURATIONS
● Example of 1:1 topology
Data can be exchanged between the master and slave over a distance of 250 m.
I/O type
RS485 type
Display plate
PC
KR20 Master
KR20
Slave
SW
*1 DC power supply
RS
232C
RS
232C
Drive circuit
RS
232C
RS
232C
Voltage input
Message Runner
Two-way communication is possible between the master and slave.
KR20 Master
KR20 Slave
PLC
Two-way communication is possible between the master and slave.
*1 For switch inputting, a separate DC power supply is necessary for inputting.
● Example of 1:N topology
I/O type
RS485 type
Up to 31 units
KR20
Slave No.1
SW
SW
DC power supply
*1
KR20
Slave No.2
SW
DC power supply
*1
Voltage input
KR20
Slave No.3
RS
485
DC power supply
*1
Voltage input
RS
485
KT4H Temperature controller
RS
485
Voltage input
Response
[%01$RC021CR]
Contact area read response
from slave No.1
RS
485
KR20
Slave
KW4M
Eco-POWER METER
KR20
Master
KR20
Master No.0
KR20
Slave
RS
232C
RS
232C
Data [%01#RCSX00001DCR]
(Contact area read command to
slave No.1)
Sending
RS
232C
RS
232C
OR
OR
RS
232C
WEB
LAN
MEWTOCOL
OR
PC
Up to eight input points, the “1:N
topology” function is available
requiring no PLCs. For details,
refer to the user’s manual.
PLC
PC
Web Datalogger Unit
PLC
*1 For switch inputting, a separate DC power supply is necessary for inputting.
*2 Contact us for equipments that can be connected to the master and slave.
PARTS NAMES AND DIMENSIONS (mm)
Main unit
Antenna
CAD Data
With
standard
antenna
The CAD data of the products with a CAD Data mark
can be downloaded from Panasonic website.
General tolerance: ±1.0
CAD Data
7.8 dia.
7 dia.
Operating mode switch
110±0.5
90°
MODE switch
ENTER switch
Four LED displays DIN hook
Power supply connector RS232C
2-4.5 dia.
AKR2002
AKR2015
AKR2045
90°
Range of
movement
10 dia.
SMA plug
Range of
movement
35 dia.
Unit No. switch
AKR2002
Power supply connector
RS232C
(4.5)
3.5
Cover
25
DIN rail attachment
gap (35 mm width)
+100
0
28.6
2000
85
71
40
Communication channel switch
110.5±2.5
120
103
31
20.4
104.4
(5.85)
(106)
Antenna mounting section
Standard antenna
(AKR2802)
Antenna with cable
(AKR2803)
Accessories:
A magnet and a double-faced tape
RS485
LED display
Output
terminal
block
Input terminal block
AKR2015
AKR2045
[With cover open]
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
KR20 WIRELESS UNIT (AKR2)
TERMINAL ARRANGEMENT
RS232C Connector
Power supply connector
• Interface specifications
DSUB 9-pin termainal layouts
Power supply connector 3-pin termainal layouts
Pin No. Signal name Line color
Pin No. Signal name Input/Output
1
1
–
–
2
GND
Blue
2
RD
Output
3
FG
Green
3
SD
Input
4
–
–
5
SG
Signal GND
6
–
–
7
RS
Input
8
CS
Output
9
–
No connection
9
6
5
12-24V DC Brown
3 2 1
1
1, 4 and 6 are connected internally.
I/O terminal block (only AKR2015 and AKR2045)
Terminal block 10, 12-pin termainal layouts
Input terminal block (AKR2015)
• Without flow control, use DSUB 9-pin female-female straight cable to connect
to the computer. If using male-female straight cable, use attached gender
changer in main unit. (when using setting tool etc.)
COM 0
1
2
Input
IN
3 COM 4
5
6
7
Input terminal block (AKR2045)
COM 0
1
Input
IN
2 3 COM 4
5
RS485 terminal block (only AKR2002)
Terminal block 5-pin termainal layouts
Pin No.
Signal name Input/Output
1
+
RS485 (+)
2
−
RS485 (−)
3
+
RS485 (+)
4
−
RS485 (−)
5
E
1
2
3
4
*The both COM of input are connected internally.
*The both COM of input are connected internally.
Output terminal block (AKR2015)
Output terminal block (AKR2045)
5
COM 0
• 1 and 3, 2 and 4 are connected internally.
• Shielded twisted-pair cable (connectable range: AWG26 to 20, cross-section
area: 0.14 to 0.5mm2) is recommended. (stripped wire length is 9mm)
• When using shielded cable, the grounding connection should have a
resistance of less than 100Ω, and grounded one end.
• Connect between each unit by extending wiring in the transmission line.
Cannot use branch connection.
• At terminal unit, “E” terminal (No.5) should be shorted with “–” terminal (No.4).
(Terminator connection)
1
Output
OUT
2 3 COM 4
Output of
communication
error
5
*The both COM of output and COM
of communication error are
connected internally.
6
7 COM ERR
Orange color
button
+
–
0
Output
OUT
1 2 + –
Output of
communication
error
3
*The both + are connected internally.
The both - are connected internally.
4
5
ERR
Orange color
button
• Shielded cable (connectable range: AWG26 to 20,cross-section area:
0.14 to 0.5mm2) is recommended. Select the diameter that there is margin in
the current capacity. (stripped wire length is 9mm)
• When using shielded cable, the grounding connection should have a
resistance of less than 100Ω, and grounded one end.
• Connect the wire with pushing the orange color button.
MOUNTING
1) Do not place the units in the vicinity of radios or TVs. Otherwise, the reception may be impaired.
2) If nearby broadcasting or wireless stations emit radio waves with a high field intensity, then this wireless system may not be used.
3) This system uses frequencies on 2.4 GHz band for data communication. If there are other devices using the same frequency band
in its vicinity, then the communication may be impaired due to interference.
4) In order to make the wireless performance better, pay attention to the below items.
• Mount the unit as high as possible.
• Connect 2 of the antenna and the mounting direction is vertical for the ground.
• Antenna should be keep away from metal board. If antennas are mounted inside the control board, the wireless performance will
decrease.
• Keep away from the place or line that noise might occur.
• Mount in the place where electric wave condition is good refer to field intensity monitor.
• When using several channels in the same communication area, check if there is no influence each other.
5) When mounting the unit to DIN rail, hook the upper part and push DIN hook. When removing it, pull out with minus driver until
locking DIN hook. And fastening plate (ATA4806) is recommended to prevent from moving.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
KR20 WIRELESS UNIT (AKR2)
RESTRICTIONS
• Wired communication restrictions
Separation of data sent on wire
The wireless unit detects the end of data sent on wire not by
control codes such as “CR”, etc., but by the idle time. Initially, if
there is an idle time equivalent to 10 characters, then it will be
deemed the end of data and the wireless unit will start
communicating. Therefore, if consecutive data includes an idle
time equivalent to 10 characters or more, then the data will be
separated. However, if the idle time between two successive
items of data is equivalent to 10 characters or less, then they will
be deemed to be partial data and will not be sent correctly.
Max. 2,048 bytes
Direction of communication between the master and slave
(1:1 topology with repeaters or 1:N topology)
Command and response is assumed in the communication
procedure. Set the master to a command sender and the slave
to a response sender.
Otherwise, the communication is impossible. If both units are set
to command senders, then communication will not be possible.
Command
Command
Response
Response
Max. 2,048 bytes
First data
Next data
RS232C or RS485
Separation time on wire
(Initial value: 10 characters)
PC
Master
Slave
Terminal
equipment
Command and response sequence
If commands are sent in succession, then define a sequence, in which a command is sent after the response to the previous
command is returned. If a time-out is defined, then the time required for wireless communication must be taken into consideration.
The time required for wireless communication may be extended depending on the communication environment. If the interval
between two commands is fixed, then a command and a response may collide with each other.
• Input signal time
During 1:1 topology or 1:1 topology with repeaters for the I/O type, the input or output signals are not always monitored. They are
monitored only immediately before wireless transmission and when their information is transmitted. In this case, if the input signal
duration is shorter than the polling time*1, then it may not be transmitted to the output terminal. Therefore, in order to ensure that the
input signal is transmitted, it must be held for the polling time or more.
*1
Polling time
AKR2015
Master input signal
Master output signal
Wireless
communication
status
Changes during wireless communication cannot be transmitted.
Wireless
communication
(forward path)
Wireless
communication
(backward path)
Wireless
communication
(forward path)
Wireless
communication
(backward path)
Wireless
communication
(forward path)
Wireless
communication
(backward path)
Master ➝ Slave
Slave ➝ Master
Master ➝ Slave
Slave ➝ Master
Master ➝ Slave
Slave ➝ Master
AKR2015
Slave output signal
Slave input signal
Response time
*2
Response time
*1 The polling time refers to a cycle for the master to continuously transmit (polling) data to a slave.
*2 The response time refers to the time required for the signal inputted to the input terminal to be outputted from the output terminal of the partner unit.
• Protocol for 1:N topology
Communication protocol
MEWTOCOL (MEW)
MODBUS ASCII
MODBUS RTU
GT Series Original
Message Runner Original
RS485 type
Yes
Yes
Yes
Yes
Yes
I/O type
Yes
–
–
–
–
Restrictions
Remark
*1
• The volume of data to be simultaneously transmitted
must not exceed 2,048 bytes.
• The time-out must be able to be extended.
Screens cannot be transferred.
Screens cannot be transferred.
*1 Operations using the PLC software are not supported.
*2 Use with 1:1 topology or 1:1 topology with repeaters for other protocols.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
KR20 WIRELESS UNIT (AKR2)
TO PREVENT FROM INTERFERENCE WITH THE OTHER WIRELESS STATION
(JAPAN ONLY)
In the frequency band using this unit, in-plant radio station (license is necessary.) using at industrial such as microwave oven, science,
medical machinery and a production line in factory to identify mobile object, specified low power radio station (license is not
necessary.) and amateur radio station (license is necessary.) are managed
1) Before using this unit, please confirm that in-plant radio station to identify mobile object, specified low power radio station and
amateur radio station are not managed.
2) When some cases of harmful electric wave interference occurred from this unit to an in-plant radio station to identify mobile object,
change the using frequency immediately or stop discharging the electric wave. After that please contact us to consult measures to
avoid interference (for example, setting of partition).
3) When any other troubles such as harmful electric wave interference occurred from this unit to a specified low power radio station or
an amateur radio station or an amateur radio station, please contact us.
ACTUAL INDICATION
(1)
(2)
(3)
2.4 DS 4
(4)
(1) 2.4:
(2) DS:
(3) 4:
(4) Bar:
2.4GHz band electric wave is used.
Modulation method is direct sequence type.
Intended interference distance is 40m.
All bands are used and possible to avoid the band of machine to identify mobile object.
* Please put the attached label “Caution for using wireless unit” near the setting place.
CAUTION CONCERNING RADIO LAW
Do not dismantle or remodel the product.
COUNTRIES WHERE THE USE OF KR20 HAS BEEN AUTHORIZED
The use of KR20 has been authorized in the following countries.
Japan, Thailand, Singapore, 25 European countries (Austria, Belgium, Czech Republic, Denmark, Estonia, Finland,
France*, Germany, Greece, Hungary, Iceland, Ireland, Italy, Lithuania, Malta, Netherlands, Norway, Poland, Portugal,
Slovakia, Slovenia, Spain, Sweden, Switzerland, UK)
* In France, this product must not be used outdoors. Please use it indoors only.
* Products with the
indication label affixed to their rear side
COMPLIANCE FOR EN STANDARD
In order to comply with EN standard, use this product in following condition.
• When installing this product to wall, install it on a DIN rail.
• Use power supply cord that is less than 3m.
• For communication cable (RS232C or RS485), use shielded cable, and connect one end of shield wire to ground.
And use ferrite core (correspond to TDK: ZCAT2035-0930) in the communication cable (RS232C or RS485) of wireless unit side.
(Turn numbers: 2T)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]