* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 3P - Middle Atlantic
Survey
Document related concepts
Wireless power transfer wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power over Ethernet wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Electric power system wikipedia , lookup
History of electric power transmission wikipedia , lookup
Audio power wikipedia , lookup
Electrical substation wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Alternating current wikipedia , lookup
Rectiverter wikipedia , lookup
Distribution management system wikipedia , lookup
Electrification wikipedia , lookup
Surge protector wikipedia , lookup
Power engineering wikipedia , lookup
Transcript
Middle Atlantic Products, Inc. Phone (973) 839-1011 Fax (973) 839-1976 Website middleatlantic.com E-mail [email protected] September 2009 Product Guide Specification Specifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part Format, including MasterFormat, SectionFormat, and PageFormat, as described in The Project Resource Manual—CSI Manual of Practice. The section must be carefully reviewed and edited by the Architect or Engineer to meet the requirements of the project and local building code. Coordinate this section with other specification sections and the Drawings. Delete all “Specifier Notes” when editing this section. Section numbers and titles are from MasterFormat 2004 Edition. SECTION 27 11 26 115-VOLT RACKMOUNT LIGHT WITH POWER DISTRIBUTION Specifier Notes: This section covers Middle Atlantic Products, Inc. PDLT 115-Volt Rackmount Light with Power Distribution. Consult Middle Atlantic Products for assistance in editing this section for the specific application. PART 1 1.1 A. 1.2 GENERAL SECTION INCLUDES 115-volt rackmount light with power distribution. RELATED SECTIONS Specifier Notes: List sections with work directly related to this section. A. 1.3 REFERENCES Specifier Notes: List standards referenced in this section, complete with designations and titles. This article does not require compliance with standards, but is merely a listing of those used. PDLT 115-Volt Rackmount Light with Power 27 11 26 - 1 A. EIA/TIA 310D – Cabinets, Racks, Panels and Associated Equipment. B. ISO 9001:2000 – Quality Management Systems – Requirements. C. UL – Underwriters Laboratories. 1.4 SUBMITTALS A. Comply with Section 01 33 00 – Submittal Procedures. B. Product Data: Submit manufacturer’s product data, including options. C. Warranty: Submit manufacturer’s standard warranty. 1.5 A. 1.6 QUALITY ASSURANCE Manufacturer’s Qualifications: ISO 9001:2000 registered company. DELIVERY, STORAGE, AND HANDLING A. Delivery: Deliver materials to site in manufacturer’s original, unopened containers and packaging, with labels clearly identifying product name and manufacturer. B. Storage: Store materials in clean, dry area indoors in accordance with manufacturer’s instructions. C. Handling: Protect materials and finish during handling and installation to prevent damage. 1.7 A. WARRANTY Warranty Period: 3 years. PART 2 2.1 A. 2.2 PRODUCTS MANUFACTURER Middle Atlantic Products, Inc. Phone (973) 839-1011. Fax (973) 839-1976. Website middleatlantic.com. E-mail [email protected]. 115-VOLT RACKMOUNT LIGHT WITH POWER DISTRIBUTION Specifier Notes: Specify one of the following two paragraphs. A. 115-Volt Rackmount Light with Power Distribution: PDLT 115-Volt Rackmount Light with Power Distribution. 1. Model: PDLT-815RV-RN. 2. Compliance: EIA/TIA 310D. 3. UL Listed: US and Canada. 4. Overall Dimensions: a. Height: 1.74 inches (44 mm). PDLT 115-Volt Rackmount Light with Power 27 11 26 - 2 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. B. b. Depth: 13.47 inches (342 mm). c. Depth of Light Shelf When Extended: 3.50 inches (89 mm). Capacity: 15 Amps. Material: 18-gauge steel. Finish of Face: Flat black powder coat. Occupy: 1 rackspace. Contact Closure: Remote surge suppression status notification to compatible monitoring device and LED status indicators. Nominal Power: 115 V AC, 60 Hz. Power Cord: 15 Amp, 14/3, 9 feet long, with NEMA 5-15P plug. Power Outlets: a. Type: Vertically oriented, NEMA 5-15R. b. Spacing: For plug-in power supplies. c. Rear: 8. Circuit Breaker: a. Capacity: 15 Amps. b. Location: Front. Retractable Light Shelf: a. Evenly distributed illumination for component viewing. b. Weight Capacity: 20 pounds. c. Light Bar: 6 white and 4 amber LEDs. d. Light Dimmer: Front-mounted control knob. e. Ball-bearing slides. Output Ports: a. Connection of optional LED gooseneck work lights. b. Type: USB style, 5 VDC. c. Rear: 2. Two-Stage, Normal-Mode, Spike and Surge Suppression and EMI Filtering: a. Nominal Line Voltage: 120 VAC. b. Maximum Line Current: 15 Amps. c. Maximum Allowable Voltage: 125 VAC (RMS). d. Protection Mode: Line to neutral. e. Peak Impulse Current (8/20 microseconds): 1) One Time: 30,000 Amps. 2) Two Times within 5 Minutes: 19,500 Amps. 3) Ten Times within 2 Minutes: 7,000 Amps. f. Maximum Clamping Voltage: 545 V at 100 Amps. g. Response Time: Instantaneous (less than 1 nanosecond). h. EMI/RF Suppression: More than 20 dB. i. Surge Energy Dissipation: 711 Joules (10/100 microseconds). j. Surge Suppression Status: 2 LED indicators. 1) Full Protection: Both LEDs lit. 2) Stage 1 Compromised, Stage 2 Active: Stage 1 LED off, stage 2 LED lit. 3) Load Unprotected or Power Off: Both LEDs off. k. Surge Suppression Circuit: Does not pass noise contamination to ground. Designer Inspired 115-Volt Rackmount Light with Power Distribution: PDLT 115-Volt Rackmount Light with Power Distribution. Specifier Notes: Specify rackmount light with power distribution model number. PDLT 115-Volt Rackmount Light with Power 27 11 26 - 3 1. 2. 3. 4. 5. Model: [PDLT-815RVA] [PDLT-815RVC]. Compliance: EIA/TIA 310D. UL Listed: US and Canada. Capacity: 15 Amps. Material: 18-gauge steel with aluminum face. Specifier Notes: Specify finish. 6. 7. 8. 9. 10. 11. 12. 13. 14. 2.3 Finish of Face: [Black brushed anodized] [Silver brushed anodized]. Occupy: 1 rackspace. Nominal Power: 115 V AC, 60 Hz. Power Cord: 15 Amps, 14/3, 9 feet long, with NEMA 5-15P plug. Power Outlets: a. Type: Vertically oriented, NEMA 5-15R. b. Spacing: For plug-in power supplies. c. Rear: 8. Circuit Breaker: a. Capacity: 15 Amps. b. Location: Rear. Retractable Light Shelf: a. Evenly distributed illumination for component viewing. b. Weight Capacity: 20 pounds. c. Light Bar: 6 white and 4 amber LEDs. d. Light Dimmer: Button under light shelf. e. Lighted Logo Dimmer: Button under light shelf. f. Ball-bearing slides. Output Ports: a. Connection of optional LED gooseneck work lights. b. Type: USB style, 5 VDC. c. Rear: 2. Two-Stage, Normal-Mode, Spike and Surge Suppression and EMI Filtering: a. Nominal Line Voltage: 120 VAC. b. Maximum Line Current: 15 Amps. c. Maximum Allowable Voltage: 125 VAC (RMS). d. Protection Mode: Line to neutral. e. Peak Impulse Current (8/20 microseconds): 1) One Time: 30,000 Amps. 2) Two Times within 5 Minutes: 19,500 Amps. 3) Ten Times within 2 Minutes: 7,000 Amps. f. Maximum Clamping Voltage: 545 V at 100 Amps. g. Response Time: Instantaneous (less than 1 nanosecond). h. EMI/RF Suppression: More than 20 dB. i. Surge Energy Dissipation: 711 Joules (10/100 microseconds). j. Surge Suppression Circuit: Does not pass noise contamination to ground. OPTIONS Specifier Notes: Specify required options. Delete options not required. Consult Middle Atlantic Products for more information. PDLT 115-Volt Rackmount Light with Power 27 11 26 - 4 A. LED Work Light: 1. 11-inch flexible gooseneck. 2. On/off switch. PART 3 3.1 EXECUTION EXAMINATION A. Examine areas to receive 115-volt rackmount light with power distribution. B. Notify Architect of conditions that would adversely affect installation or subsequent use. C. Do not begin installation until unacceptable conditions are corrected. 3.2 INSTALLATION A. Install 115-volt rackmount light with power distribution in accordance with manufacturer’s instructions at locations indicated on the Drawings. B. Install 115-volt rackmount light with power distribution plumb, level, square, and secure. 3.3 A. 3.4 A. ADJUSTING Repair minor damages to finish in accordance with manufacturer’s instructions and as approved by Architect. PROTECTION Protect installed 115-volt rackmount light with power distribution from damage during construction. END OF SECTION PDLT 115-Volt Rackmount Light with Power 27 11 26 - 5