Download 3P - Middle Atlantic

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Wireless power transfer wikipedia , lookup

Voltage optimisation wikipedia , lookup

Power over Ethernet wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Electric power system wikipedia , lookup

History of electric power transmission wikipedia , lookup

Audio power wikipedia , lookup

Electrical substation wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Alternating current wikipedia , lookup

Rectiverter wikipedia , lookup

Distribution management system wikipedia , lookup

Electrification wikipedia , lookup

Surge protector wikipedia , lookup

Power engineering wikipedia , lookup

Mains electricity wikipedia , lookup

AC adapter wikipedia , lookup

Opto-isolator wikipedia , lookup

Transcript
Middle Atlantic Products, Inc.
Phone
(973) 839-1011
Fax
(973) 839-1976
Website
middleatlantic.com
E-mail
[email protected]
September 2009
Product Guide Specification
Specifier Notes: This product guide specification is written according to the Construction Specifications
Institute (CSI) 3-Part Format, including MasterFormat, SectionFormat, and PageFormat, as described
in The Project Resource Manual—CSI Manual of Practice.
The section must be carefully reviewed and edited by the Architect or Engineer to meet the
requirements of the project and local building code. Coordinate this section with other specification
sections and the Drawings. Delete all “Specifier Notes” when editing this section.
Section numbers and titles are from MasterFormat 2004 Edition.
SECTION 27 11 26
115-VOLT RACKMOUNT LIGHT WITH POWER DISTRIBUTION
Specifier Notes: This section covers Middle Atlantic Products, Inc. PDLT 115-Volt Rackmount Light
with Power Distribution. Consult Middle Atlantic Products for assistance in editing this section for the
specific application.
PART 1
1.1
A.
1.2
GENERAL
SECTION INCLUDES
115-volt rackmount light with power distribution.
RELATED SECTIONS
Specifier Notes: List sections with work directly related to this section.
A.
1.3
REFERENCES
Specifier Notes: List standards referenced in this section, complete with designations and titles. This
article does not require compliance with standards, but is merely a listing of those used.
PDLT 115-Volt Rackmount Light with Power
27 11 26 - 1
A.
EIA/TIA 310D – Cabinets, Racks, Panels and Associated Equipment.
B.
ISO 9001:2000 – Quality Management Systems – Requirements.
C.
UL – Underwriters Laboratories.
1.4
SUBMITTALS
A.
Comply with Section 01 33 00 – Submittal Procedures.
B.
Product Data: Submit manufacturer’s product data, including options.
C.
Warranty: Submit manufacturer’s standard warranty.
1.5
A.
1.6
QUALITY ASSURANCE
Manufacturer’s Qualifications: ISO 9001:2000 registered company.
DELIVERY, STORAGE, AND HANDLING
A.
Delivery: Deliver materials to site in manufacturer’s original, unopened containers and
packaging, with labels clearly identifying product name and manufacturer.
B.
Storage: Store materials in clean, dry area indoors in accordance with manufacturer’s
instructions.
C.
Handling: Protect materials and finish during handling and installation to prevent damage.
1.7
A.
WARRANTY
Warranty Period: 3 years.
PART 2
2.1
A.
2.2
PRODUCTS
MANUFACTURER
Middle Atlantic Products, Inc. Phone (973) 839-1011. Fax (973) 839-1976. Website
middleatlantic.com. E-mail [email protected].
115-VOLT RACKMOUNT LIGHT WITH POWER DISTRIBUTION
Specifier Notes: Specify one of the following two paragraphs.
A.
115-Volt Rackmount Light with Power Distribution: PDLT 115-Volt Rackmount Light with Power
Distribution.
1.
Model: PDLT-815RV-RN.
2.
Compliance: EIA/TIA 310D.
3.
UL Listed: US and Canada.
4.
Overall Dimensions:
a.
Height: 1.74 inches (44 mm).
PDLT 115-Volt Rackmount Light with Power
27 11 26 - 2
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
B.
b.
Depth: 13.47 inches (342 mm).
c.
Depth of Light Shelf When Extended: 3.50 inches (89 mm).
Capacity: 15 Amps.
Material: 18-gauge steel.
Finish of Face: Flat black powder coat.
Occupy: 1 rackspace.
Contact Closure: Remote surge suppression status notification to compatible monitoring
device and LED status indicators.
Nominal Power: 115 V AC, 60 Hz.
Power Cord: 15 Amp, 14/3, 9 feet long, with NEMA 5-15P plug.
Power Outlets:
a.
Type: Vertically oriented, NEMA 5-15R.
b.
Spacing: For plug-in power supplies.
c.
Rear: 8.
Circuit Breaker:
a.
Capacity: 15 Amps.
b.
Location: Front.
Retractable Light Shelf:
a.
Evenly distributed illumination for component viewing.
b.
Weight Capacity: 20 pounds.
c.
Light Bar: 6 white and 4 amber LEDs.
d.
Light Dimmer: Front-mounted control knob.
e.
Ball-bearing slides.
Output Ports:
a.
Connection of optional LED gooseneck work lights.
b.
Type: USB style, 5 VDC.
c.
Rear: 2.
Two-Stage, Normal-Mode, Spike and Surge Suppression and EMI Filtering:
a.
Nominal Line Voltage: 120 VAC.
b.
Maximum Line Current: 15 Amps.
c.
Maximum Allowable Voltage: 125 VAC (RMS).
d.
Protection Mode: Line to neutral.
e.
Peak Impulse Current (8/20 microseconds):
1)
One Time: 30,000 Amps.
2)
Two Times within 5 Minutes: 19,500 Amps.
3)
Ten Times within 2 Minutes: 7,000 Amps.
f.
Maximum Clamping Voltage: 545 V at 100 Amps.
g.
Response Time: Instantaneous (less than 1 nanosecond).
h.
EMI/RF Suppression: More than 20 dB.
i.
Surge Energy Dissipation: 711 Joules (10/100 microseconds).
j.
Surge Suppression Status: 2 LED indicators.
1)
Full Protection: Both LEDs lit.
2)
Stage 1 Compromised, Stage 2 Active: Stage 1 LED off, stage 2 LED lit.
3)
Load Unprotected or Power Off: Both LEDs off.
k.
Surge Suppression Circuit: Does not pass noise contamination to ground.
Designer Inspired 115-Volt Rackmount Light with Power Distribution: PDLT 115-Volt
Rackmount Light with Power Distribution.
Specifier Notes: Specify rackmount light with power distribution model number.
PDLT 115-Volt Rackmount Light with Power
27 11 26 - 3
1.
2.
3.
4.
5.
Model: [PDLT-815RVA] [PDLT-815RVC].
Compliance: EIA/TIA 310D.
UL Listed: US and Canada.
Capacity: 15 Amps.
Material: 18-gauge steel with aluminum face.
Specifier Notes: Specify finish.
6.
7.
8.
9.
10.
11.
12.
13.
14.
2.3
Finish of Face: [Black brushed anodized] [Silver brushed anodized].
Occupy: 1 rackspace.
Nominal Power: 115 V AC, 60 Hz.
Power Cord: 15 Amps, 14/3, 9 feet long, with NEMA 5-15P plug.
Power Outlets:
a.
Type: Vertically oriented, NEMA 5-15R.
b.
Spacing: For plug-in power supplies.
c.
Rear: 8.
Circuit Breaker:
a.
Capacity: 15 Amps.
b.
Location: Rear.
Retractable Light Shelf:
a.
Evenly distributed illumination for component viewing.
b.
Weight Capacity: 20 pounds.
c.
Light Bar: 6 white and 4 amber LEDs.
d.
Light Dimmer: Button under light shelf.
e.
Lighted Logo Dimmer: Button under light shelf.
f.
Ball-bearing slides.
Output Ports:
a.
Connection of optional LED gooseneck work lights.
b.
Type: USB style, 5 VDC.
c.
Rear: 2.
Two-Stage, Normal-Mode, Spike and Surge Suppression and EMI Filtering:
a.
Nominal Line Voltage: 120 VAC.
b.
Maximum Line Current: 15 Amps.
c.
Maximum Allowable Voltage: 125 VAC (RMS).
d.
Protection Mode: Line to neutral.
e.
Peak Impulse Current (8/20 microseconds):
1)
One Time: 30,000 Amps.
2)
Two Times within 5 Minutes: 19,500 Amps.
3)
Ten Times within 2 Minutes: 7,000 Amps.
f.
Maximum Clamping Voltage: 545 V at 100 Amps.
g.
Response Time: Instantaneous (less than 1 nanosecond).
h.
EMI/RF Suppression: More than 20 dB.
i.
Surge Energy Dissipation: 711 Joules (10/100 microseconds).
j.
Surge Suppression Circuit: Does not pass noise contamination to ground.
OPTIONS
Specifier Notes: Specify required options. Delete options not required. Consult Middle Atlantic
Products for more information.
PDLT 115-Volt Rackmount Light with Power
27 11 26 - 4
A.
LED Work Light:
1.
11-inch flexible gooseneck.
2.
On/off switch.
PART 3
3.1
EXECUTION
EXAMINATION
A.
Examine areas to receive 115-volt rackmount light with power distribution.
B.
Notify Architect of conditions that would adversely affect installation or subsequent use.
C.
Do not begin installation until unacceptable conditions are corrected.
3.2
INSTALLATION
A.
Install 115-volt rackmount light with power distribution in accordance with manufacturer’s
instructions at locations indicated on the Drawings.
B.
Install 115-volt rackmount light with power distribution plumb, level, square, and secure.
3.3
A.
3.4
A.
ADJUSTING
Repair minor damages to finish in accordance with manufacturer’s instructions and as approved
by Architect.
PROTECTION
Protect installed 115-volt rackmount light with power distribution from damage during
construction.
END OF SECTION