* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download rack mounting power supplies - dual tracking outputs
Electrical ballast wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Power over Ethernet wikipedia , lookup
Power factor wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Electric power system wikipedia , lookup
Electrical substation wikipedia , lookup
Current source wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Audio power wikipedia , lookup
Schmitt trigger wikipedia , lookup
Electrification wikipedia , lookup
Stray voltage wikipedia , lookup
Power inverter wikipedia , lookup
Pulse-width modulation wikipedia , lookup
History of electric power transmission wikipedia , lookup
Three-phase electric power wikipedia , lookup
Power engineering wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Surge protector wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Voltage regulator wikipedia , lookup
Opto-isolator wikipedia , lookup
Alternating current wikipedia , lookup
Voltage optimisation wikipedia , lookup
Buck converter wikipedia , lookup
Power supply wikipedia , lookup
RACK MOUNTING POWER SUPPLIES DUAL TRACKING OUTPUTS INSTALLATION AND OPERATION These power supplies are constructed in the form of assemblies that are front mountable in standard 19” wide RETMA cabinet racks. If possible, mount in the rack spaced away from other heat dissipating or air blocking assemblies, by using blank front panels above and below each power supply. This will result in cooler running operation, which in turn will maximize stability and reliability. Make all connections before applying AC input power. THE SENSING TERMINALS MUST BE CONNECTED to the output terminals, either at the barrier strip on the power supply or at the load. Failure to have the sense terminals connected will affect the output voltage (usually causing it to be higher than the rating of the supply, and unadjustable), and may result in permanent damage to both the power supply and its load. If voltage drops in the output voltage leads (which degrade regulation) are not objectionable, local sensing can be used; leave in place the jumpers provided with the power supply on the barrier strip (connecting the +SENS to the +V terminal and the -SENS to the -V terminal). However, if the best possible regulation at the load is required, then remove the jumpers and use two additional leads to connect the sense terminals to the output leads at the load, as shown in the schematic. This configuration permits the power supply to sense and compensate the voltage actually across the load. Note that remote sensing is capable of compensating only limited wiring drops. The voltage across the load, plus the voltage drops through the wiring, must be within the output voltage range of the supply for the voltage at the load to remain within the load regulation specification. If there is any possibility of voltage from another source (another power supply, a battery, transients, etc) being applied to the power supply’s output terminals, protect the power supply by using a diode in series with the +V lead and another in series with the -V lead. Do not attempt to directly parallel the outputs of two power supplies. This would result in current flowing from the higher-set output into the lower-set output, and probable damage to both circuits. Outputs may be used in series to obtain a higher voltage provided that a reverse-biased diode, having PIV and current ratings exceeding the combined output, is used across each output; however, keep in mind that the output current to be drawn cannot exceed the output current rating of the lowest rated supply used. Frequent fuse failure is symptomatic of power supply overload, a short circuited output, a tripped overvoltage protector, or power supply failure. Do not overfuse; this can result in damage to the power supply. These power supplies operate as constant voltage sources when used at load current equal to or less than their ratings. If the power supply is overloaded, the current limit circuit will automatically reduce the output voltage, and it will then attempt to recover to its normal operating point. Therefore, A meter selector switches for "G" option TRANSITORY OVERLOAD RESULTS IN A MOMENTARY DROP IN OUTPUT meter:M2 meter:M1 VOLTAGE. However, if the overload is still present when the voltage attempts (optional) (optional) H to recover, the voltage will continue to alternately drop and recover, which will appear as a sawtooth oscillation of the output. Do not operate the power supply Front Panel Voltage Adjust Handles(2) Power Switch in this mode; reduce the load so that an output current equal to or less than the (optional) (optional) rating of the supply will be drawn. 17.0" rear panel connections OPIAN ALL AC IES SUPPL R E W O . P N U.S.A MADE I WARRANTY: Acopian power supplies are warranted to be free from defects in material and workmanship for a period of five years (encapsulated devices and fans, for one year) from date of original shipment. Acopian’s obligation under this warranty is limited to repairing any power supply returned to the factory Service Department in Easton, PA and replacing any defective parts. Authorization must be obtained from Acopian before a power supply may be returned for repair. Transportation charges are to be paid by the purchaser. A reinspection and handling charge will be applied to returned units found to have no defects. If a failure has been caused by misuse, operation in excess of specifications, or modification by the customer, repairs will be billed at cost; in such cases, a cost estimate will be submitted before work is started. Acopian reserves the right to make changes or improvements in its products without incurring any obligation to install the same on products previously manufactured. This warranty is in lieu of all other warranties, obligations, and liabilities, expressed or implied, and is the purchaser’s exclusive remedy. Acopian makes no warranty, either express or implied, of merchantability, fitness for a particular purpose or otherwise. In no event shall Acopian be liable for incidental or consequential damages of any kind, including loss of business or profits, or any other losses incurred by the purchaser or any third party. The validity, performance and construction of all terms and conditions and any sale made by Acopian shall be determined by the law of Pennsylvania, not including its law of conflict of laws. Perforated Covers (Top & Bottom) L 19.0" .12 Case Size H 3P11 5P12 3 1⁄2˝ 5 1⁄4˝ L 10 7⁄8˝ 11 15⁄16˝ Approx. Weight 22 lb. 28 lb. Rear Panel Connections: COM L N –S –V AC AC +V +S Barrier Strip with 6-32 terminal screws The complete Acopian catalog is available on the Internet at http://www.acopian.com P.O. Box 638, Easton, PA 18044 • Phone: (610) 258-5441 • FAX: (610) 258-2842 Rev1 If the AC input power contains large voltage spikes (‘noise’) induced by the switching of high currents, inductive loads, electro-mechanical components, etc., the input power leads to the supply should include some means of transient suppression. Otherwise, a portion of the noise may be coupled through the supply to the load. Also, the supply could be damaged. The means of suppression that is easiest to install is a 1 mfd capacitor or a metal oxide surge suppressor (MOV) across the AC input terminals of the supply. In extremely severe cases, the use of RF chokes in series with each side of the line may also be required. RACK MOUNTING POWER SUPPLIES - DUAL TRACKING OUTPUTS Acopian Dual Tracking Rack Mounting power supplies conveniently furnish plus and minus voltages required for powering operational amplifiers and related circuits. Provision for remote sensing and electronic short circuit protection are standard features, and options include metering and overvoltage protection. They are conservatively rated for operation at ambient temperatures to +55°C. K2 C1 K3 + C9 R33 10 11 12 7 6 R27 R28 R4 + C2 R3 K11 K5 K8 F1 L N AC INPUT K6 C5 R16 K7 + C10 CASE 105 -125 VAC, 50-400Hz (Standard) 210-250 VAC, 50-400Hz (When model number ends in -230) Q4 R34 10 11 12 7 6 K17 R29 R30 R18 R13 C11 + y C13 R22 R24 K14 K16 K18 2 + 6 10 C12 3 7 1 IC2 4 8 2 13 R31 C6 5 9 5 4 3 R26 Output Connection Variations +V +V +V + SENS + SENS + SENS COM – SENS option "A" Ammeters R19 R2 + R11 R10 +SENSE R1 + R25 +V K15 K13 2 6 10 3 7 1 IC1 4 8 2 13 5 9 5 C4 4 3 Q3 + R21 R23 R17 K20 SW1 R5 R6 M2 – R31 A C7 R8 COM LOAD + C3 – SENS –V –V + – + COMMON V M1 + C8 LOAD LOAD Option "G" Voltmeter and Ammeter (each with selector switch) V M2 R20 LOAD K9 option "F" Voltmeters R7 COM LOAD – SENS –V M1 – R32 A R12 + LOAD Rev2 K4 K12 + Q2 + – K10 R9 + C14 Pin numbers shown outside IC1 and IC2 apply for dual inline package. Pin numbers in circles apply for metal can package. +V x y (optional ) K1 R15 Q1 Depending on Model #, T1 may be one or two transformers connected in series, parallel, or a combination of both. T1 x K19 OVERVOLTAGE PROTECTOR Depending upon output current rating, either 3 or 4 pairs of Q1 & R15 and Q3 & R16 are used in parallel. –SENSE +SENSE R31 SW2 + A – M1 SW3 + V M2 – R32 COM –SENSE –V –V The MODEL NUMBER indicates any included options; prefix V: overvoltage protection suffix A: ammeters suffix F: voltmeters suffix G: ammeter and voltmeter, each with selector switch suffix H: handles suffix M: terminal strip cover suffix P: front panel voltage adjust suffix –230: 230v input