* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Picture Coming Soon
Josephson voltage standard wikipedia , lookup
Flip-flop (electronics) wikipedia , lookup
Nanogenerator wikipedia , lookup
Audio power wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Analog-to-digital converter wikipedia , lookup
Radio transmitter design wikipedia , lookup
Power MOSFET wikipedia , lookup
Integrating ADC wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Current source wikipedia , lookup
Transistor–transistor logic wikipedia , lookup
Wilson current mirror wikipedia , lookup
Valve audio amplifier technical specification wikipedia , lookup
Voltage regulator wikipedia , lookup
Valve RF amplifier wikipedia , lookup
Two-port network wikipedia , lookup
Surge protector wikipedia , lookup
Schmitt trigger wikipedia , lookup
Operational amplifier wikipedia , lookup
Power electronics wikipedia , lookup
Current mirror wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Series AMEOF5-JZ O 5 Watt | AC-DC Converter Picture Coming Soon FEATURES: • • • • • Models Single output Input: 85-264VAC, 47-440Hz or 100-400VDC Operating temperature -25°C to +85°C Low power consumption ≤ 0.5W Continuous short circuit protection Class II power supply • • • • I/O Isolation 3000VAC Ultra slim open frame SIP Over current protection Over voltage protection Input Voltage (VAC/Hz) Input Voltage (VDC) Full power temperature range (ºC) Output Voltage (V) Output Current max (mA) Maximum capacitive load (µF) Efficiency (%) AMEOF5-3.3SJZ AMEOF5-5SJZ AMEOF5-9SJZ AMEOF5-12SJZ AMEOF5-15SJZ AMEOF5-24SJZ 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 100-400 100-400 100-400 100-400 100-400 100-400 0 to +55 0 to +55 0 to +55 0 to +55 0 to +55 0 to +55 3.3 5 9 12 15 24 1000 1000 560 420 340 210 2200 1500 680 470 330 100 67 74 75 76 77 79 AMEOF5-5SLJZ AMEOF5-12SLJZ AMEOF5-15SLJZ AMEOF5-24SLJZ 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 100-400 100-400 100-400 100-400 0 to +55 0 to +55 0 to +55 0 to +55 5 12 15 24 1000 420 340 210 1500 470 330 100 74 76 77 79 Model NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Current Inrush current <2ms External fuse Input dissipation Leakage current Conditions Typical 115VAC 230VAC 115VAC 230VAC Recommended slow blow type No Load CY(Input to Output) 1nF/400VAC 5 10 1 Maximum 200 100 Units 0.5 250 mA mA A A A W µA Maximum Units Output Specifications Parameters Voltage accuracy Line regulation Load regulation Ripple & Noise Over current protection Short circuit protection Short circuit restart Over Voltage protection Hold up time Conditions Typical Full load, 3.3V output Full load, others Full load 10% - 100% load 20MHz Bandwidth Auto-recovery 115VAC 230VAC ±3 ±2 ±0.5 ±1.5 150 ≥110 Continuous Auto-recovery Zener diode clamp 20 80 % % % mV p-p % of I out ms ms Isolation Specifications Parameters Tested I/O voltage Isolation Resistance www.aimtec.com F 052e R0.C Conditions Typical 60 sec, 5mA leakage current >1000 Tel: +1 514 620 2722 1 of 3 Rated Units 3000 VAC MΩ Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOF5-JZ O 5 Watt | AC-DC Converter General Specifications Parameters Conditions Switching frequency Operating temperature Storage temperature Temperature coefficient Cooling Humidity Weight Dimensions (L x W x H) MTBF Typical Maximum Units 100 -25 to +85 -40 to +105 ±0.02 Free air convection KHz °C °C % / °C 85 7 1.65 x 0.54 x 0.79 inches 42.00 x 13.65 x 20.00 mm o >300,000 hours (MIL-HDBK -217F, Ground Benign, t=+25 C) % RH g See derating curve Safety Specifications Parameters UL IEC/EN/UL60950-1 EN 55022, Class A & B, with external filter circuits, as referenced IEC 61000-4-2, Contact ±4KV, Criteria B IEC 61000-4-3, 10V/m, Criteria A, with Class A external filter, as referenced IEC 61000-4-4, ±2KV/±4KV, Criteria B, with Class A/B external filter referenced IEC 61000-4-5, ±1KV/±2KV, Criteria B, with Class A/B external filter referenced IEC 61000-4-6, 3Vrms, Criteria A, with Class B external filter, as referenced IEC 61000-4-8, 10A/m, Criteria A IEC 61000-4-11, 0-70%, Criteria B Pin Out Specifications* Dimensions Single AC N AC L +V sc -V sc -V Output +V Output 42.00 (1.65) Bottom View Front View * Add capacitor between pin 5 & 7. Application circuit below. 10.00 (0.39) 1 3 5 12 7 1.30 (0.05) 13.65 (0.54) 20.00 (0.79) 1 3 5 7 12 14 14 1.50 (0.06) Pin 33.02 (1.30) 4.40 (0.17) Standards 0.50 (0.02) Approvals Note: Unit: mm (inch) Pin diameter tolerance: ±0.10 (±0.004) Case tolerance: ±0.50 (±0.02) 5.08 (0.20) L models Right view 5.08 (0.20) www.aimtec.com F 052e R0.C 1.60 (0.06) 33.02 (1.30) 0.80 (0.03) 4.40 (0.17) 6.00 (0.24) 13.65 (0.54) Front view 0.40 (0.02) Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOF5-JZ O 5 Watt | AC-DC Converter Derating* Free Air Convection at 25°C Free Air Convection 100 80 Output Power (%) 100 Safe Operating Area Input 110-240VAC or 135-320VDC 60 40 20 80 Safe Operating Area 60 40 20 0 0 55 - 25 -20 0 20 40 60 85 240 (340) 85 110 (70) (100) 100 80 Ambient Temperature º C 264 (400) Input Voltage VAC (VDC) *Power derating: for 85-110VAC and 240-264VAC input supply Recommended EMC class A external circuit: FUSE 1A/250V Single Output R 12 NTC 14 3 AC L MOV S14K350 CX1 0.1µF/ 300V C1 10µF/ 400V +Vout 5 + TVS AC + DC C2 C3 0.1µF/50V 7 AC N 1 12 - Vout CY1 1nF/400VAC Recommended EMC class B external circuit: FUSE 1A/250V LCM 3.5mH Single Output LDM 0.33mH NTC 14 3 AC L MOV S14K350 CX 0.1µF/ 300VAC AC N CY2 1nF/ 400VAC CY3 1nF/ 400VAC + 5 C1 10µF/ 400V 3.3 & 5 Vout 9 Vout 12 & 15 Vout 24 Vout AC + DC 7 1 GND Model +Vout 12 C2 TVS C3 0.1µF/50V - Vout CY1 1nF/400VAC C2 220 µF / 35V 150 µF / 35V TVS 7V 12V 20V 30V Note: For Safety compliance we recommend minimum PCB trace distance of 3mm, primary to secondary circuit minimum distance between PCB traces of 6.4mm. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R0.C Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only