Download impedance stabilization network for screened balanced pairs

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Audio power wikipedia , lookup

Opto-isolator wikipedia , lookup

Superheterodyne receiver wikipedia , lookup

Telecommunications engineering wikipedia , lookup

Power electronics wikipedia , lookup

Multimeter wikipedia , lookup

Automatic test equipment wikipedia , lookup

Decibel wikipedia , lookup

Spectrum auction wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Valve RF amplifier wikipedia , lookup

Power dividers and directional couplers wikipedia , lookup

Radio transmitter design wikipedia , lookup

Nominal impedance wikipedia , lookup

Scattering parameters wikipedia , lookup

HD-MAC wikipedia , lookup

Two-port network wikipedia , lookup

Standing wave ratio wikipedia , lookup

Zobel network wikipedia , lookup

Tektronix analog oscilloscopes wikipedia , lookup

Rectiverter wikipedia , lookup

Transcript
ISN ST08
IMPEDANCE STABILIZATION NETWORK FOR
SCREENED BALANCED PAIRS
Impedance stabilization networks (ISN, or with CISPR 16-1-2 called AAN: asymmetric artificial network
or AN: artificial networks for coaxial and other screened cables) are defined for measuring of conducted
common mode disturbances at information technology equipment (ITE) as required in CISPR 22.
The ISN is placed between the equipment under test (EUT) and auxiliary equipment (AE) or load which are
necessary for the operation of the EUT. The ISN establishes the common-mode termination impedance
for the EUT’s telecommunications port during measurement. All internal parts fulfill the requirements
of cat.6 or better and provide optimal transfer performance. The used internal cable has a symmetrical
impedance of 100 Ω. The pin- arrangement of the RJ45 sockets meets the requirements of EIA / TIA 568B.
For use with screened RJ45
ISN ST08 meets the requirements of CISPR 22, EN 55022, CISPR 32, EN 55032, CISPR 16-1-2 and
EN 55016-1-2. Unlike the ISN T types for unscreened balanced lines the ISN ST08 needs no additional
adapters for LCL setting.
connections
Up to 8 lines / 4 pairs
Meets the requirements of Technical specifications
CISPR 22, CISPR 32, CISPR 16-1-2
Design given in figure D.11 of
CISPR 22 and G.11 of CISPR 32
Can be used as CDN for IEC 61000-4-6 immunity tests
Network applications
Screened balanced lines
STP, FTP, SFTP
Cat.3, cat.5, cat.5e, cat.6, cat.7
Ethernet with10 BaseT, 100 BaseT,
1000 BaseT, 10 GBaseT
RJ45
Frequency range:
150 kHz to 230 MHz
Line parameters:
4 pairs, balanced, shielded, 100 Ω impedance
Power rating (EUT and AE port)
AC max. voltage:
100 V
DC max. voltage:
150 V
Current max :
1.2 A (line)
Test voltage:
200 VDC, 2 sec
Common mode impedance (EUT port) 150 kHz to 30 MHz: 150 Ω ±20 Ω
30 MHz to 230 MHz:
150 Ω +60 Ω / -45 Ω
Phase angle (EUT port) 150 kHz to 30 MHz:
0° ±20°
Coupling path (In / Out port / EUT)
Connection:
BNC 50 Ω
RF voltage:
<20 V
Voltage division factor (RF input to EUT port) 150 kHz to 30 MHz:
9.5 dB ±1 dB
30 MHz to 230 MHz:
9.5 dB +4 dB / -2 dB
Transmission bandwidth (wanted signal) EUT / AE B3 dB: * > 250 MHz sin.
Decoupling of common mode disturbances (EUT / AE)
150 kHz to 1.5 MHz:
≥60 dB
1.5 MHz to 30 MHz:
≥60 dB
230 MHz:
≥40 dB
*) all balanced parameters are in relation to a symmetrical load of 100 Ω
ISN ST08
IMPEDANCE STABILIZATION NETWORK FOR
SCREENED BALANCED PAIRS
Test setup example for disturbance voltage measurements on screened balanced pairs
CISPR 16-1-1 RECEIVER
CH 2
MEAS
FOR
SCL
ON/OFF
STO
RCL
DIA
DIS
TRA
Help
FRQ
LVL
StSize
Step
StSize
StSize
Step
2
Step
STO
MOD
RCL
Run
Stop
Back
Local
RF
CH 1
2nd
MOD
Hold
1
3
LVL
MOD
7
8
9
MHz
dBµV
STO
RCL
MOD
4
5
6
kHz
dBm
FRQ
LVL
MOD
1
2
3
Hz
V
STO
RCL
MOD
0
.
FRQ
Tuning
Enter
RF IN 50 Ω
USB
USB
Power
Equipment
under test
To auxiliary
equipment
ISN S
AE Port
EUT
EUT Port
Reference ground plane
Insulating
Example of the level setting setup (system calibration for immunity testing according
IEC / EN 61000-4-6)
Test generator e.g. Teseq NSG 4070
with built-in RF synthesizer,
brodband power amplifier and
power meter
6 dB
Attenuator
NSG 4070
RF out
No load or
adapter required
ISN ST08
150 Ω / 50 Ω adapter
EUT Port
SAR T800 adapter
100 Ω
AE Port
CAL U100B
Ground plane
7
8
9
MHz
dBµV
FRQ
LVL
4
5
6
kHz
dBm
STO
RCL
3
Hz
V
StSize
Step
Power meter
Amp in
< +10 dBm
Amp out
ch.3 < +20 dBm
ch.2 < +20 dBm
1
2
0
.
ON/OFF
Help
StSize
StSize
Step
2
Step
1
Enter
Local
RF
MOD
2nd
3
Tuning
Hold
ch.1 < +27 dBm
Back
Run
Stop
USB
Power
Power meter
with input impedance 50 Ω
The ISN ST08 is appropriate for immunity tests of IEC / EN 61000-4-6. Optional available are the parts for
the level setting setup CAL U100B (150 Ω / 50 Ω adapter) and SAR T800 (common mode adapter for RJ45).
ISN ST08
IMPEDANCE STABILIZATION NETWORK FOR
SCREENED BALANCED PAIRS
Example of the EUT setup for immunity testing according IEC / EN 61000-4-6
Test generator e.g. Teseq NSG 4070
with built-in RF synthesizer,
brodband power amplifier and
power meter
NSG 4070
RF out
7
8
9
MHz
dBµV
FRQ
LVL
4
5
6
kHz
dBm
STO
RCL
1
2
3
Hz
V
StSize
Step
StSize
StSize
Step
.
Step
2
0
Power meter
Amp in
6 dB attenuator
< +10 dBm
Amp out
ch.3 < +20 dBm
ch.2 < +20 dBm
1
Enter
Local
RF
MOD
ON/OFF
Help
2nd
3
Tuning
Hold
ch.1 < +27 dBm
Back
Run
Stop
USB
ISN ST08 view to RJ45 connection
Equipment
under test
Auxiliary
equipment
AE
Power
ISN S
AE Port
EUT
EUT Port
Ground plane
Insulating
Mechanical specifications
Size (W x H x D):
Weight:
245 mm x 100 mm x 100 mm
approx. 1.5 kg
Model No. and options
Teseq GmbH
Landsberger Str. 255 · 12623 Berlin · Germany
T + 49 30 56 59 88 35 F + 49 30 56 59 88 34
[email protected] www.teseq.com
© December 2014 Teseq ®
Specifications subject to change without notice.
Teseq ® is an ISO-registered company. Its products
are designed and manufactured under the strict
quality and environmental requirements of the ISO
9001. This document has been carefully checked.
However, Teseq ® does not assume any liability for
errors or inaccuracies.
82-248650 E03 December 2014
Part number
Description
248650
97-248650
247825
242439 ISN ST08
ISN for screened eight lines with RJ45 connector
ISN Sxxx-TC
Traceable calibration (ISO17025), order only with ISN S, related to CISPR 22 / 32 and IEC / EN 61000-4-6
CAL U100B Universal calibration unit (150 Ω / 50 Ω adapter)
SAR T800 Calibration adapter part for ISNs with RJ45 connector (common mode adapter)