* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download SSR2-2X SER Y Ü A2957 R13 A2958 R2.FH9
Electrical ballast wikipedia , lookup
Electrical substation wikipedia , lookup
Three-phase electric power wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Current source wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Power inverter wikipedia , lookup
Integrating ADC wikipedia , lookup
Semiconductor device wikipedia , lookup
Alternating current wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Protective relay wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Power MOSFET wikipedia , lookup
Stray voltage wikipedia , lookup
Schmitt trigger wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Surge protector wikipedia , lookup
Buck converter wikipedia , lookup
Voltage regulator wikipedia , lookup
Voltage optimisation wikipedia , lookup
Current mirror wikipedia , lookup
Switched-mode power supply wikipedia , lookup
TIME DEVICES LEFT-RIGHT DEVICES (SSR-2 SERIES) / FLASHER DEVICES (EF SERIES) STAR-DELTA TIMER (ER / SER SERIES) / IMPULSE DELAYED TIME DEVICE (DG-06) Function Diagram 1 2 t1 Left t U : Source Voltage t1 5 (2) t0(sec.) 4 5 a2 6 a1 1-2-3 : Left 4-5-6 : Right Technical Data Rated Voltage (Un) Operating Range Rated Frequency Output Contacts Delay Time (SSR-2X) Delay Time (SSR-2) Ambient Temperature Protection Class Dimensions Installation Weight : 24 VAC / DC, 230 VAC : (0.9-1.1) x Un (for 230 VAC) (0.8-1.2) x Un (for 24 VAC) (0.9-1.1) x Un (for 24 VDC) : 50 Hz (for, 24, 220 VAC) : 2 Change-Overs, 5A, 1250 VA : t0: 6-60 sec. adjustable t1: 18-180 sec. adjustable : t0: 5 sec. constant t1: 5-90 sec adjustable : -5 oC ; + 50 oC : IP 20 : Tip PK 10 : Surface Mounting or on the mounting rails : 0.3 kg. EF-10 / EF-10T : General Flasher Devices EF type flasher devices are developed due to create adjustable periodic impulses. They are produced in two different ways: EF-10 : Flasher device with Relay output EF-10T : Flasher device with Triac output Connection Diagram EF-10 EF-10T 1 3 2 a2 a1 : Output Voltage ton Rated Frequency Output Contacts Delay Time Ambient Temperature Protection Class Dimensions Installation Weight C3 t : 24 VAC / 230 VAC : (0.9-1.1) x Un (for 230 VAC) (0.9-1.1) x Un (24 VAC) (0.9-1.1) x Un (24 VDC for EF-10) : 50 Hz (24, for 230 VAC) : EF-10: 1 C/O, 8A, 2000 VA : EF-10T: Triac, 8A, 400 V : tON: 0.5 sec. constant : tOFF: 1-10 sec. adjustable : -5 oC ; + 50 oC : IP 20 : Type PK 10 (for EF-10T) Type PK 22 (for EF-10) : Surface Mounting or on the mounting rails : 0.3 kg. (for EF 10T) 0.1 kg. (for EF 10) W V U L1 T1 2/15 O 2 3 a2 U N a1 2/15 1/16 C2 C3 C2 a2 (a3 ) TYPE PK 21 PK 15 PK 25 3/18 Function Diagram TYPE PK 28 3/18 1/16 a1 / 2/15 is applied between A2-A3 for PK-25 t U t tA t t : 230 VAC, 50 Hz. : (0.9-1.1) x Un : 0.1 - 6 sec. (adjustable) : 1 C/O, 5A, 1250 VA : -5 oC ; + 50 oC : IP 20 : Type PK 10 : Surface Mounting or on the mounting rails : 0.3 kg. Precautions For Installation and Safe Use Failure to follow those instructions will result in death or serious injury. Disconnect all power before working on equipment. When the device is connected to the network, do not remove the front panel. Do not try to clean the device with solvent or the like. Only clean the device with a dried cloth. Verify correct terminal connections when wiring. Electrical equipment should be serviced only by your compedent seller. No responsibility is assured by the manufacturer or any of its subsidiaries for any consequences arising out of the use of this material. Mount device to the panel. No responsibility is assured by the manufacturer or any of its subsidiaries for any consequences arising out of the use of this material. t0 DELTA t Technical Data Rated Voltage (Un) ER : 230 VAC * SER : 230 VAC, 24 VAC/DC Operating Range (DU) : (0.8-1.2) x Un (for 230 VAC) (0.8-1.2) x Un (for 24 VAC) (0.9-1.1) x Un (for 24 VDC) Rated Frequency (f) : 50/60 Hz. (for AC) Output Contacts : 2 N/O, 5A, 1250 VA Delay Time (tA) ER : 1-30 sec. / 2-60 sec. (for PK 21) SER : 10 sec./30 sec./60 sec. (for PK 15) SER : 1-60 sec. (for PK 25 / PK-28) Ambient Temperature : -5 oC ; + 50 oC Protection Class : IP 20 Dimensions : Type PK21 (for ER) Type PK15-PK25-PK28 (for SER) Installation : Surface Mounting or on the mounting rails : 0.15 kg (for ER) Weight 0.07 kg (PK 15), 0.18 kg (PK 25) ** 0.10 kg. (PK 25) *** 0.2 kg (PK 28) * Different supply voltages are adjusted upon request. ** For types only 230 V operation voltage. *** For types 230 V AC, 24 V AC / DC operation voltage. Dimensions 23 48 mm 34 mm 35 44 80 80 TYPE PK 15 59.7 mm TYPE PK 28 TYPE PK 21 50 74 45 Ø4.0 60 TYPE PK 10 A2957 / Rev.13 3/18 STAR When the supply is applied, output relay turns ON and while supply exists output relay keeps energized. When the supply is cut off, output relay stays energized during adjusted t1 time (0.1-6 sec). At the end of that time, output relay turns OFF. If the supply is applied before t1 time isnt up, output relay continues to stay energized. Weight C3 a1 a2 Note: 24 VAC/DC supply of SER and between A1-A3 for PK-28. t2<t1 U : Source Voltage : Device Voltage C1 a1 (a3 ) Function Diagram t1 C1 / ER / SER- 1/16 1 a2 1 Y X Z M 3~ Circuit Plan If the supply is OFF less than 6* sec. output of the device doesnt change. Connection Diagram C2 T1 Impulse Delayed Time Device a2 Technical Data Rated Voltage (Un) Operating Range DG-06 : General Rated Voltage (Un) Operating Range Delay Time Output Contacts Ambient Temperature Protection Class Dimensions Installation t toff C1 : 24 VAC/DC 230 VAC : (0.9-1.1) x Un (for 230 VAC) (0.8-1.2) x Un (for 24 VAC) (0.9-1.1) x Un (for 24 VDC) Rated Frequency : 50 Hz (for 230 VAC) Output Contacts : 1 C/O, 5A, 1250 VA Delay Time : tON : 1, 20, 60 min.* tOFF: 1, 20, 60 min.* Ambient Temperature : -5 oC ; + 50 oC Protection Class : IP 20 Dimensions : Type PK 10 Installation : Surface Mounting or on the mounting rails Weight : 0.3 kg. * Can be set to different value upon request Technical Data Function Diagram U :Source Voltage t ton 2 1 a1 t toff Technical Data Rated Voltage (Un) Operating Range 60 6 L1 L2 L3 : Output Voltage On R L 18 s 30 Main Connection t t (1) 4 (3) 6 3 Connection Diagrams a1 14 t1 t0 Left-Right Device 3 min. a2 80 t0 Connection Diagrams A2 2 80 t0 Right A1 EF-2X 1 110 U SSR-2X Connection Diagram Function Diagram U : Rated Voltage : Output Voltage High quality digital timers used for safe operation of star-delta starter systems. When the operating voltage is applied, the star contacts [(1/16, 2/15) for PK21/PK15, for PK25], are closed and then released after the operating time, tA. The delta contacts [(2/15, 3/18) for PK21/PK15] are closed after the transition time, t0 = 50 msec (fixed at factory). The fault of the transition time is ± 5 msec. This transition time can be adjusted (to= 20-500 msec.) in PK25 / PK 28 type. The EF-2X device with adjustable ton and toff times is developed in order to create periodic impulses. 3 Star - Delta Timer 35 32 48 58 TYPE PK 22 TYPE PK 25 61.8 mm When the line voltage is applied, the right output relay starts to work as switching ON and the left output relay as switching OFF. At the end of t1 time both of two output relays switch OFF and this condition is kept for t0 times. At the end of this. period, the left output relay switches OFF and the right output relay switches ON and also this situation is kept during t1 time. / ER / SER General 45.4 mm Utilization and Operation Principles Flasher Device 90 mm Left-right device is used to inverse rotating direction of 2 ways rotating machine used in industry. This device with time adjustment, repeats its functions according to specified periods. EF-2X : General 35.3 mm SSR-2 / SSR-2X : Left-Right Devices General 62 90 17 TYPE PK 22 TYPE PK 25 36 mm