Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
DIGITAL PROJECTION RADIOGRAPHY COMPUTED RADIOGRAPHY DIGITAL PROJECTION RADIOGRAPHY DEPENDS ON COMPUTER TECHNOLOGY TO PRODUCE DIGITAL RADIOGRAPHIC IMAGE DIGITAL PROJECTION RADIOGRAPHY COMPUTED RADIOGRAPHY (CR) DIGITAL RADIOGRAPHY (DR) DIGITAL RADIOGRAPHY vs COMPUTED RADIOGRAPHY DR X-RAYS DETECTORS ADC 11011101 CR X-RAYS CR PLATE SCANNER ADC 11011101 COMPUTED RADIOGRAPHY (CR): USES PHOTOSTIMULABLE PLATE (IMAGE PLATE) INSTEAD OF FILM, AS THE IMAGE RECEPTOR. CR USES CASSETTE THAT LOOKS VERY SIMILAR TO CONVENTIONAL RADIOGRAPHIC CASSETTE. CR PLATE !!!!! DOES NOT USE SCREENS OR FILM ( CONVENTIONAL FILM) CR PLATE CASETTE CONSTRUCTION ► LIGHTWEIGHT ALUMINUM ► PLASTIC ► STEEL FRAME FRONT PANEL MADE OF LOW ATTENUATION CARBON FIBER CR CASSETTES ARE NOT LIGHTTIGHT IMAGE PLATE IS NOT SENSITIVE TO LIGHT CR CASSETTE IS PROTECTING IMAGE PLATE FROM DAMAGE + IS THE STABLE VEHICLE FOR TRANSPORT AND PLACEMENT OF THE CASSETTE UNDER THE PATIENT BACK PANEL CONTAINS LEAD FOIL TO PROTECT THE PLATE FROM BACKSCATTER BACK PANEL ALSO CONTAINS CHIP TO RECORD PATIENT DEMOGRAPHIC INFORMATION REMOTE OPERATOR PANEL IMAGE PLATE APPROX. 1MM CROSS-SECTION OF CR PLATE PROTECTIVE LAYER PHOSPHOR LAYER ANTI-HALO & REFLECTIVE LAYER BASE BACKING LAYER BASE ► PET- POLYETHYLENE TERAPHTALATE PHOSPHOR LAYER ► Ba FX: Eu +2 PROTECTIVE LAYER ► FLUORINATED POLYMER MATERIAL PROTECTS PHOSPHOR LAYER ANTI-HALO LAYER + REFLECTIVE LAYER ► PREVENTS LASER FROM PASSING THROUGH. ► REFLECTED LIGHT FROM PHOSPHOR IS ALLOWED TO PASS. BACKING LAYER ► PROTECTS THE BASE FROM DAMAGE. LEAD COATING SCATTER The simplest explanation for luminescence is that impurities in the crystal lattice are responsible for luminescence. As the concentration of impurity ions increase the greater the intensity of the luminescence. CR screens use barium fluorohalides doped with europium (europium is the impurity in the crystal). When phosphors are stimulated with x-ray photon energy electron pair holes are created. In effect, europium is raised to an excited state and upon luminescence it is returned to its ground Eu2+ state. This mechanism holds for both spontaneous luminescence and photostimulated luminescence The shifting of europium from its excited state back to its ground state for both spontaneous and photostimulated luminescence is about 0.6 - 0.8 microseconds. With screen-film imaging these crystals spontaneously luminescence to expose a film, but with CR imaging the luminescence occurs, then there is also photoluminescence that occurs when the screen is stimulated by a narrow beam of infrared light. The holes or vacancies in the lattice are portions of the lattice normally occupied by halogens (fluoride, bromide, or iodine). These vacancies will trap free electrons when irradiated and are called Farbzentren centers or F-centers. When the photostimulable plate is exposed to high frequency light, usually from a helium laser, the electrons in these F-centers are liberated and cause luminescence at readout. THE LATENT IMAGE WILL REMAIN STORED FOR 24 HOURS. IT WILL FADE THROUGH PHOSPHORESCENCE FADING ► 25% OF STORED ENERGY ► WITHIN 8 HOURS CR AFTER EXPOSURE IS INSERTED INTO CR SCANNER CR PLATE CR SCANNER/READER THE SCANNER SCANS THE IMAGE PLATE WITH LASER LIGHT AND READS THE LATENT IMAGE FROM THE PHOSPHOR READOUT LASER LIGHT HELIUM-NEON (633 nm) LASER BEAM SWEEPS THE PLATE IN RASTER FASHION RASTER LASER PM TUBE LIGHT GATE AMPLIFIER ADC SWEEPING OF THE LASER ACROSS THE PLATE ► FAST SCAN DIRECTION ► SCAN DIRECTION ► LASER SCAN DIRECTION PLATE MOVEMENT IN THE SCANNER ► SLOW SCAN DIRECTION ► SUB-SCAN DIRECTION ► PLATE SCAN DIRECTION THE SPEED OF THE SCANNING LASER BEAM IS ADJUSTED TO THE LUMINESCENT SIGNAL LASER 633 nm PHOTOSTIMULABLE LUMINESCENCE 390-400 nm PLATE & F-CENTERS LASER LASER SPOT SIZE - 100 MICROMETERS PIXEL SIZE - 100 MICROMETERS P.M. TUBE DETECTION SENSITIVITY MATCHED TO BLUE-PURPLE PSL (390-400 nm) AFTER SCANNING THE CR PLATE NEED TO BE CLEARED FROM RESIDUAL SIGNAL PLATE EXPOSED TO HIGH INTENSITY SODIUM VAPOR OR FLUORESCENT LIGHT Typical image plate can be reused thousands of times IMAGE DISPLAY IMAGE CHECK-INDEX??? IMAGE MANIPULATIONWINDOWING PICTURE DESTINATION -PACS PACS CR CHARACTERISTIC CURVE ► VERY WIDE LATITUDE CR SYSTEMS ► LESS RADIOGRAPH REPEATS CHARACTERISTIC CURVE LATITTUDE OF FILM LATITTUDE OF CR IMAGE CAN BE SALVAGED WITH CR ► 500% ► 80% OVEREXPOSURE UNDEREXPOSURE USE ADEQUATE KVP HARD COPY GENERATED IN LASER PRINTER CR SYSTEM EFFICIENCY CHARACTERISTIC ► QDE- QUANTUM DETECTION EFFICIENCY NO NEED FOR SCREENS QDE: THE MEASURE OF THE EFFICIENCY OF CR SYSTEM TO CONVERT REMNANT X-RAYS TO USEFUL IMAGE SIGNAL QDE PATIENT DOSE DIGITAL RADIOGRAPHY ELECTRONIC DETECTORS ► INDIRECT TECHNIQUE CLASS ► DIRECT TECHNIQUE CLASS INDIRECT TECHNIQUE ► INDIRECT CONVERSION FLAT PANEL DETECTORS ► INDIRECT CONVERSION CHARGED COUPLE DEVICE DETECTORS INDIRECT CONVERSION FLAT PANEL DETECTORS ► USE THIN LAYERS OF SILICON COMBINED WITH THE ARRAYS OF PHOTODIODES. P.D. IS COATED WITH CESIUM IODIDE OR RARE EARTH MATERIAL- WHEN STRUCK BY REMNANT X-RAYS THEY EMIT LIGHT. ADVANTAGE: HIGH QDE DISADVANTAGE: LIGHT DIVERGENCE PHOTODIODE INDIRECT CONVERSION CHARGE COUPLED DEVICE DETECTORS ► USE CCD ARRAYS TO RECORD THE VISIBLE LIGHT EMITTED BY A SCINTILLATION CRYSTAL THAT HAS ABSORBED THE ENERGY. AN OPTICAL COUPLING SYSTEM DEMAGNIFIES THIS LIGHT AND SENDS IT TO THE CCD ARRAY. OPTICAL COUPLING CCD DIRECT TECHNIQUE ► DIRECT CONVERSION FLAT PANEL DETECTORS DIRECT CONVERSION FLAT PANEL DETECTORS ► USE AN AMORPHOUS SELENIUM COATED THIN FILM TRANSISTOR ARRAY THAT DIRECTLY CONVERTS XRAY ENERGY INTO ELECTRICAL SIGNAL. REMNANT XRAYS ARE ABSORBED IN THE SELENIUM WHERE THEY FORM ELECTRON-HOLES. CAPACITORS COLLECT THE CHARGE. ADVANTAGE: NO LIGHT DIVERGENCE READY - The 17"x17" amorphous selenium-based sensor is electrically sensitized and readied for exposure. EXPOSE - Incident X-ray photons are converted into electron-hole pairs. A transverse electric field separates the electrons and holes and creates a charge image precisely corresponding to the X-ray image. READOUT - The microplasma line scanner sweeps across the sensor in less than 2 seconds causing readout of the charge image and sensor reset. DR vs CR COMPARISON DR SYSTEM ADVANTAGE ► ► ► ► ► IMMEDIATE REDOUT CASSETTE FREE OPERATION GOOD FOR HIGH VOLUME RADIOGRAPHY CAN BE USED FOR MAMMOGRAPHY DETECTORS CAN BE REEXPOSED IMMEDIATELY DISADVANTAGE ► ► ► MORE EXPENSIVE CAN NOT BE USED IN PORTABLE RADIOGRAPHY?????? NOT COMPATIBLE WITH EXISTING TABLES PORTABLE???? PORTABLE CT???!! MONITORS IN DR ► 1K ► 2K ► 4K ► 1,000 X 1,000 PIXELS ► 2,000 X 2,000 PIXELS ► 4,000 X 4,000 4K MONITORS USED IN MAMMOGRAPHY PIXELS AND CHEST RADIOGRAPHY DR TERMS TO KNOW PIXEL ► VOXEL ► SPATIAL RESOLUTION ► DYNAMIC RANGE ► CONTRAST RESOLUTION ► IMAGE NOISE ► PIXEL . VOXEL The formation