LEVEL MONITOR WITH LINEARIZATION, ANALOG AND DATASHEET F173 - LEVEL MONITOR HIGH / LOW ALARM OUTPUTS Advantages Signal output • Robust IP67 (NEMA Type4X) field enclosure. It is so rugged, you can even stand on it! • Intrinsically Safe available - ATEX and IECEx approval for gas and dust applications. • Programming can be done by your own crew, with the sensible menu-driven structure, saving cost and irritation. Know one, know them all! • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors! • Up to 4 free configurable alarm outputs. • (0)4 - 20mA / 0 - 10V DC according to the linearized level. Features • The F-Series is your first and safest choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, salty atmosphers and temperatures between -40°C up to +80°C (-40°F up to 176°F). • Level measurement where linearization and continuous level monitoring is important. Also re-transmission of the level or serial communication is required. Alternative basic model: F070 - F073 - F077 and F170 or the D-Series DIN panel mount indicators. Signal input Level • (0)4 - 20mA. • 0 - 10V DC. Applications • Displays level and percentage filled. • 15 point linearization of the tank shape - with interpolation. • Four alarm values can be entered: low-low, low, high and high-high level alarm. • Large 17mm (0.67") digits. • Selectable on-screen engineering units; volumetric or mass. • Explosion/flame proof available. • Full Modbus communication RS232/485/TTL. • Loop or battery powered, 8 - 24V AC/DC or 115 - 230V AC power supply. • Sensor supply 3 / 8.2 / 12 / 24V DC. 1 General information The output signals can be a passive NPN, active PNP or an isolated electro-mechanical relay. Introduction The F173 is a versatile level indicator with linearization and continuous level monitoring feature. It offers the facility to set two low level and two high level alarm values. If desired, an ignore function can be set up to allow for an incorrect level for a certain period of time. Up to four outputs are available to transmit the alarm condition. A wide selection of options further enhances the capabilities, including Intrinsic Safety and full Modbus communication. Signal input The F173 does accept (0)4 - 20mA and 0 - 10V input signals from any type of level measurement device. Also a 4 - 20mA input loop powered model is available. Communication All process data and settings can be read and modified manually or through the Modbus communication link (RS232 / RS485). Full Modbus functionality remains available for the Intrinsically Safe version (TTL). Display The display has large 17mm (0.67”) and 8mm (0.31”) digits which can be set to show level, percentage and alarm values. The alarm values can be password protected. On-screen engineering units are easily configured from a comprehensive menu. Hazardous areas This model has been ATEX and IECEx certified Intrinsically Safe for gas and dust applications, with an allowed ambient temperature of -40°C to +70°C (-40°F to +158°F). A flame proof Ex d enclosure with ATEX certification is also available. Configuration All configuration settings are accessed via a simple operator menu which can be password protected. Each setting is clearly indicated with an alphanumerical description, which avoids confusing abbreviations. All settings are safely stored in EEPROM memory in the event of sudden power failure. Enclosures Various types of enclosures can be selected, all ATEX and IECEx approved. As standard the F173 is supplied in an GRP panel mount enclosure, which can be converted to an IP67 / NEMA Type4X GRP field mount enclosure by the addition of a back case. Most popular is our rugged aluminum field mount enclosure with IP67 / NEMA Type4X rating. Both European or U.S. cable gland entry threads are available. Analog output signal The actual level is re-transmitted with the (0)4 - 20mA or 0 - 10V DC output signal. The output signal is updated eight times per second with a filter function being available to smoothen out the signal if desired. The output value is user defined in relation to the level, e.g. 4mA equals to 5m3 and 20mA equals to 20.000 m3. The output signal can be passive, active or isolated where the passive output type will loop power the F173 as well. Overview application F173 alarm output R1 alarm output R2 alarm output R3 alarm output R4 Analog output Communication link Alarm outputs Level input Up to four configurable outputs are available to transmit the alarm condition. You can have e.g. two the same low alarm outputs, one high alarm output and one "all alarms" output. Type OS offers four mechanical relay outputs. However, only two outputs are available in Intrinsically Safe aplications. Three outputs are available in all other configurations. high - high high low low - low 2 Linearization F173 0.9" 14mm 1 2 / "NPT 15mm 38mm 24mm 24mm 36mm 36mm 1 2 / "NPT 15mm HP 1 2 / "NPT HT 6 x M12 HJ Ø22 ( 7/8") Ø22 ( 7/8") Ø22 ( 7/8") HK 1.18" 1.18" Flat bottom, no holes available. 1 /2"NPT HU 4 x M20 x 1.5 HV HZ 3 + Display example - 90 x 40mm (3.5” x 1.6”) + + + PL: input loop powered (terminals GND - 1 - 2 are not available) = = = = OR: mech. relay + OT: passive trans. 07 08 I I+ I+ I+ I+ I+ U U+ AU: 0 - 10V I AP: 4 - 20mA I- AI: 4 - 20mA I- AF: 4 - 20mA I AB: 0 - 20mA 09 10 I+ I+ A - PL: 4 - 20mA U+ U: 0 - 10V A: (0)4 - 20mA + + 11 13 14 15 16 OA: active 24V DC + OT: passive trans. 17 18 19 60 mm (2.36") Please note: Terminal connections for the F173 with four alarm outputs (type OS) is shown on one of the next pages. 12 30mm 30mm PB / PC: battery powered Internal long life Lithium battery AP: 8 - 30V DC Output loop powered - ZB: Backlight: 12 - 24V DC - PX: 8 - 30V DC PM: 115 - 230V AC - PF: 24V DC + 30mm (1.18") 30mm (1.18") + Ø12 PF: 24V AC 24mm 24mm 36mm 36mm OR: mech. relay HH - M20 x 1,5 Ø20 + 12mm 12mm - Ø20 PD - XI: 16 - 30V DC M20 x 1,5 OT: passive trans. HG AA: 4 - 20mA Ø22 ( 7/8") 06 25mm 25mm 05 HF OA: active 24V DC M16 x 1,5 Ø20 04 Ø16 ALARM OUTPUT 3 HD 03 M20 x 1,5 PG9 OA: active 24V DC HO HE LEVEL SENSOR INPUT GRP PD: 8 - 24V DC 12mm 12mm HN 112 mm (4.40") 02 M20 x 1,5 HM 20 21 Ø 7mm (0.27") 01 25mm 22 23 24 panel cut-out 00 25mm 25 26 27 A A DTR +12V RXD CT: TTL Intrinsically Safe CI: RS485 - 4 wire 28 RXD CH: RS485 - 2 wire DTR +12V CB: RS232 TXD B B TXD 29 COMMUNICATION 98 (3.86") 115 (4.53") PD: 8 - 24V AC M20 x 1,5 HL ANALOG OUTPUT /2"NPT ALARM OUTPUT 1 1 ALARM OUTPUT 2 M16 x 1,5 1.18" 22,50mm Aluminum POWER REQUIREMENTS 30mm 30mm HA 22,50mm (0.9") 30mm 30mm 22,50mm 75 mm (2.95") 22,50mm / "NPT Ø 7mm (0.27") 17mm 0.9" 130 mm (5.12") 14mm 1 2 22,50mm HB & HC enclosures 22,50mm (0.9") 22,50mm 1.18" 22,50mm PG9 17mm 130 mm (5.12") + F173 29 mm (1.14") + 0.9" 31 mm (1.22") 15mm 120 mm (4.72") Y 30 Z 31 Aluminum & GRP panel mount enclosure + 16mm 120 mm (4.72") Dimensions enclosures Terminal connections Aluminum & GRP field / wall mount enclosures Ø16 Typical wiring diagram F173-A-AP-CH-OT-PX Typical wiring diagram F173-A-AA-CB-OA-PD OUTPUT LOOP POWERED 24V AC / DC POWER SUPPLY TERMINAL CONNECTORS F100 - series Modbus communication type CB: RS232 29 28 27 Common ground 26 29 28 DTR 12V 26 Common ground RXD 6 Supply * 11 Level sensor input type A: (0)4 - 20mA Signal 09 10 Common ground e.g. indicator 06 Common ground 04 01 Power supply type PX: 8 - 30V DC (not used in this example) Common ground *Supply voltage: 3.2V DC to sensor 8 - 24V AC Power supply type PD: 8 - 24V AC / DC 00 01 00 03 Common ground Switch output type OA: active 24V DC signal 02 Switch output type OT: passive transistor - 04 + 03 alarm output 2 Main supply Common ground Switch output type OA: active 24V DC signal 05 - 05 Switch output type OT: passive transistor alarm output 2 Common ground Analog output type AA: active 4 - 20mA alarm output 1 + 06 alarm output 1 Common ground Level sensor input type A: (0)4 - 20mA 08 09 08 07 - Common ground 8 - 30V DC - e.g. indicator Common ground + Analog output type AP: passive 4 - 20mA (loop powered) + Common ground 5 Common ground 10 Signal Switch output type OA: active 24V DC signal 07 15 11 Supply * Switch output type OT: passive transistor - Common ground alarm output 3 + 16 alarm output 3 8 - 24V DC - A TXD 27 Modbus communication type CH: RS485 - 2 wire B + TERMINAL CONNECTORS F100 - series *Supply voltage: 3.2 / 8.2 / 12 / 24V DC to sensor 4 F173 Typical wiring diagram F173-A-AI-CI-OR-PM Typical wiring diagram F173-A-AP-CB-OS-PD 115 - 230V AC POWER SUPPLY Z 31 Y 30 B 29 TXD A RXD Modbus communication type CI: RS485 - 4 wire 28 27 26 14 alarm output 3 Switch output type OS: mechanic relay alarm output 2 Signal 10 09 09 Analog output type AI: 8 - 30V DC passive isolated 4 - 20mA 05 Switch output type OR: mechanic relay Main supply Common ground 24V AC Power supply type PD: 24V AC / DC 00 01 L1 02 N 06 00 01 02 03 Common ground 03 04 Signal alarm output 2 Power supply type PM: 115 - 230V AC Level sensor input type A: (0)4 - 20mA *Supply voltage: 3.2 / 8.2 / 12 / 24V DC to sensor 5 24V DC - 07 Supply * + 05 alarm output 1 *Supply voltage: 3.2 / 8.2 / 12 / 24V DC to sensor F173 8 - 30V DC - 04 e.g. indicator Common ground 08 08 + Common ground N Analog output type AP: passive 4 - 20mA (loop powered) e.g. indicator Main supply 0 - 230V AC / DC + Common ground L1 alarm output 1 10 11 Level sensor input type A: (0)4 - 20mA - Supply * 11 12 13 15 - Common ground 15 16 8 - 24V DC alarm output 3 alarm output 4 + Switch output type OT: passive transistor 16 17 26 Common ground 29 Modbus communication type CB: RS232 DTR 12V Common ground 24V AC / DC POWER SUPPLY TERMINAL CONNECTORS F100 - series 28 TERMINAL CONNECTORS F100 - series Hazardous area applications Certificate of conformity KEMA 03ATEX1074 X • IECEx DEK 11.0042X The F173-XI has been certified according ATEX and IECEx by DEKRA for use in Intrinsically Safe applications with an ambient temperature of -40°C to +70°C (-40°F to +158°F). • The ATEX markings for gas and dust applications are: II 1 G Ex ia IIB/IIC T4 Ga II 1 D Ex ia IIIC T100 °C Da. • The IECEx markings for gas and dust applications are: Ex ia IIC/IIB T4 Ga and Ex ia IIIC T100 °C Da. Besides the I.S. power supplies for the two alarm outputs, it is allowed to connect up to three I.S. power supplies in IIB/IIIC applications or one in IIC applications. Consult the certificate for the maximum input and output values of the circuits. Full functionality of the F173 remains available, including two alarm outputs and 4 - 20mA output and Modbus communication (type CT). Power supply type PD-XI offers a sensor supply according to the connected power supply voltage at terminal 1. An ATEX approved flame proof Ex d enclosure is available as well. Please contact your supplier for further details. Configuration example IIB / IIIC - F173-A-AF-CT-OT-PC-XI - Battery powered HAZARDOUS AREA SAFE AREA RXD Uo=max 30V 28 TXD 29 Modbus communication type CT: TTL 26 e.g. indicator Ci = 17nF Analog output type AF: passive floating 4 - 20mA 10 07 06 05 03 04 Po=max 750mW Uo=max 30V Po=max 750mW Io=max 100mA Alarm output 2 6 Uo=max 30V Io=max 100mA Alarm output 1 - Switch output type OT: passive transistor Po=max 750mW + Ci is negligibly small Uo=max 30V - Common ground Switch output type OT: passive transistor Po=max 750mW Io=max 100mA + Common ground Ci is negligibly small Uo=max 30V Io=max 100mA - 08 09 Level sensor input type A: 4 - 20mA + Ci is negligibly small - Circuit depends on type of signal + Signal Common ground Po=max 850mW e.g. PC For example: MTL5051 - Common ground 27 + DTR +12V Io=max 250mA ISOLATOR: I.S. Certified Isolator TTL to RS232 / RS422 / TTL REPEATER For example MTL 5541 POWER SUPPLY e.g. MTL 5525 and / or REPEATER e.g. MTL 5541 e.g. indicator POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 e.g. sounder POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 e.g. sounder Note: above values are safety values. Consult the technical specification for operational values. F173 Configuration example IIB / IIIC - F173-A-AP-CT-OT-(PX)-XI - Output loop powered HAZARDOUS AREA TERMINAL CONNECTORS F100 - series SAFE AREA RXD Uo=max 30V 28 TXD 29 Modbus communication type CT: TTL 26 11 + 09 Analog output type AP: passive 4 - 20mA (output loop powered) 07 06 Switch output type OT: passive transistor Po=max 750mW Uo=max 30V Po=max 750mW Io=max 100mA Alarm output 1 Switch output type OT: passive transistor 03 01 PX: Not used in this example 00 Common ground * Note sensor supply voltage: 3.2V DC - not suitable to power analog sensors. 7 Uo=max 30V Io=max 100mA Alarm output 2 - 04 + Common ground Ci is negligibly small Uo=max 30V Io=max 100mA 05 Ci is negligibly small Po=max 750mW - 08 e.g. indicator Ci = 17nF Uo=max 30V Io=max 100mA + Common ground Level sensor input type: A (0)4 - 20mA - Common ground Ci is negligibly small + 10 Signal - Circuit depends on type of signal For example: MTL5051 Supply * Common ground F173 Po=max 850mW e.g. PC - Common ground 27 + DTR +12V Io=max 250mA ISOLATOR: I.S. Certified Isolator TTL to RS232 / RS422 / TTL REPEATER For example MTL 5541 POWER SUPPLY e.g. MTL 5525 and / or REPEATER e.g. MTL 5541 e.g. indicator POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 e.g. sounder POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 Po=max 750mW e.g. sounder Note: above values are safety values. Consult the technical specification for operational values. Configuration example IIB / IIIC and IIC - F173-A-AP-(CT)-OT-PD-XI - Power requirement 16 - 30V DC HAZARDOUS AREA TERMINAL CONNECTORS F100 - series SAFE AREA RXD Uo=max 30V 28 TXD 29 Modbus communication type CT: TTL Please note: communciation type CT is not allowed in IIC applications. Po=max 850mW e.g. PC For example: MTL5051 26 - Common ground 27 + DTR +12V Io=max 250mA ISOLATOR: I.S. Certified Isolator TTL to RS232 / RS422 / TTL * Note: Communication only allowed when configured as IIB / IIIC. 11 Supply * Level sensor input type: A (0)4 - 20mA Common ground Ci is negligibly small e.g. indicator Ci = 17nF Analog output type AP: passive 4 - 20mA 07 08 Common ground 10 Signal 09 Circuit depends on type of signal TOTAL Co OF ALL CONNECTED ANALOG APPARATUS IN IIC APPLICATIONS MAY NOT EXCEED 66nF MINUS 17nF (17nF IS USED BY THE ANALOG OUTPUT SIGNAL TERMINAL 7 + 8). Switch output type OT: passive transistor 05 03 01 e.g. sounder Po=max 750mW POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 e.g. sounder Uo=max 30V POWER SUPPLY Po=max 750mW Uo=max 30V Io=max 100mA Alarm output 2 02 Main supply Switch output type OT: passive transistor - 04 + Common ground Ci is negligibly small POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 Uo=max 30V Io=max 100mA Alarm output 1 - 06 + Common ground Ci is negligibly small + Io=max 100mA 00 - Common ground Power supply type PD: 16 - 30V DC (please note: PD and battery supply (type PC) is NOT allowed in IIC applications). Po=max 750mW For example MTL 5525 Note: above values are safety values. Consult the technical specification for operational values. * Note power supply type PD: the supply voltage to the analog sensor is as connected to terminal 1 (internally linked). 8 F173 Configuration example IIB / IIIC - F173-A-AF-CT-OT-(PC)-(PD)-XI - Power requirement 16 - 30V DC or battery powered HAZARDOUS AREA TERMINAL CONNECTORS F100 - series SAFE AREA RXD Uo=max 30V 28 TXD 29 Modbus communication type CT: TTL For example: MTL5051 26 11 Supply * + e.g. indicator Analog output type AF: passive floating 4 - 20mA 07 06 Switch output type OT: passive transistor 04 03 02 Due to analog output type AF, the unit has to be powered with battery type PC or with external power supply type PD. Uo=max 30V POWER SUPPLY Power supply type PD: 16 - 30V DC 00 Uo=max 30V Io=max 100mA Alarm output 2 Io=max 100mA - 01 e.g. sounder Io=max 100mA + Common ground Po=max 750mW Po=max 750mW - Main supply Switch output type OT: passive transistor e.g. sounder POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 Uo=max 30V + Common ground Ci is negligibly small e.g. indicator POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 Po=max 750mW Alarm output 1 REPEATER For example MTL 5541 POWER SUPPLY e.g. MTL 5525 and / or REPEATER e.g. MTL 5541 Uo=max 30V Io=max 100mA 05 Common ground Ci is negligibly small Po=max 750mW - Ci = 17nF Uo=max 30V Io=max 100mA + 08 09 Level sensor input type: A (0)4 - 20mA - Ci is negligibly small + Common ground 10 Signal - Circuit depends on type of signal Po=max 850mW e.g. PC - Common ground 27 + DTR +12V Io=max 250mA ISOLATOR: I.S. Certified Isolator TTL to RS232 / RS422 / TTL Po=max 750mW For example MTL 5525 Note: above values are safety values. Consult the technical specification for operational values. * Note power supply type PD: the supply voltage to the analog sensor is as connected to terminal 1 (internally linked). F173 9 Directives & Standards Technical specification EMC Low voltage RoHS ATEX / IECEx IP & NEMA General Display Type Dimensions Digits Refresh rate Option ZB Note ZB High intensity reflective numeric and alphanumeric LCD, UV-resistant. 90 x 40mm (3.5” x 1.6”). Seven 17mm (0.67") and eleven 8mm (0.31") digits. Various symbols and measuring units. User definable: fast, 1sec , 3sec, 15sec, 30sec, off. Transflective LCD with white LED-backlight. Good readings in full sunlight and darkness. Only available for safe area applications. Directive 2014/30/EU, FCC 47 CFR part 15. Directive 2014/35/EU Directive 2011/65/EU Directive 2014/34/EU, IEC 600079-0, IEC 60079-11. EN 60529 & NEMA 250 Enclosure General Window Sealing Control keys Polycarbonate window. Silicone. Three industrial micro-switch keys. UV-resistant silicone keypad. Ambient temperature Safe areas -40°C to +80°C (-40°F to +176°F). Intrinsically Safe -40°C to +70°C (-40°F to +158°F). Aluminum wall / field mount enclosures General Power requirements Dimensions Weight Type AP Analog output loop powerd, 8 - 30V DC. Power consumption max 0.5 Watt. Type PB Long life Lithium battery - life-time depends upon settings and configuration - up to 5 years. (requires PD, PL or PX) Type PC Intrinsically Safe long life lithium battery - life-time depends upon settings and configuration - up to 5 years. (requires XI and PD or PX) Type PD 8 - 24V AC / DC ± 10%. Power consumption max. 10 Watt. Intrinsically Safe: 16 - 30V DC; power consumption max. 0.75 Watt. Type PF 24V AC / DC ± 10%. Power consumption max. 15 Watt. Type PL Input loop powered from sensor signal 4 - 20mA (type “A”) - requires types AI and OT (not Xi). Type PM 115 - 230V AC ± 10%. Power consumption max. 15 Watt. Type PX 8 - 30V DC. Power consumption max. 0.5 Watt. Type ZB 12 - 24V DC ± 10%. Power consumption max. 1 Watt. Note PB/PF/PM Not available Intrinsically Safe. Note PF/PM The total consumption of the sensors and outputs may not exceed 400mA @ 24V. Note For Intrinsically Safe applications, consult the safety values in the certificate. Type HA Type HL Type HM Type HN Type HO Type HP Type HT Type HU Type HV Type HZ GRP wall / field mount enclosures General Dimensions Weight Type HD Type HE Type HF G Type H Type HH Type HJ Type HK Sensor excitation Type PB/PC/PX Note Type PD Type PD-XI Type PF / PM 3V DC. This is not a real sensor supply. Only suitable for sensors with a very low power consumption. 3 / 8.2 / 12 / 24V DC - max. 50mA @ 24V DC. The sensor supply volage is according to power supply as connected to terminal 1 (internally linked). 3 / 8.2 / 12 / 24V DC - max. 400mA @ 24V DC. GRP wall/field mount enclosure IP67 / NEMA Type4X, UV-resistant and flame retardant. 130 x 120 x 75mm (5.12" x 4.72" x 2.95") - W x H x D. 600 gr. Cable entry: no holes. Cable entry: 2 x Ø 16mm and 1 x Ø 20mm. Cable entry: 1 x Ø 22mm (7/8"). Cable entry: 2 x Ø 20mm. Cable entry: 6 x Ø 12mm. Cable entry: 3 x Ø 22mm (7/8"). Flat bottom, cable entry: no holes. Panel mount enclosures Dimensions Panel cut-out Type HB Weight Type HC Terminal connections Type Die-cast aluminum wall/field mount enclosure IP67 / NEMA Type4X with 2-component UV-resistant coating. 130 x 120 x 75mm (5.12" x 4.72" x 2.95") - W x H x D. 1100 gr. Cable entry: 2 x PG9 and 1 x M20. Cable entry: 3 x 1/2" NPT. Cable entry: 2 x M16 and 1 x M20. Cable entry: 1 x M20. Cable entry: 2 x M20. Cable entry: 6 x M12. Cable entry: 1 x 1/2" NPT. Cable entry: 3 x 1/2" NPT. Cable entry: 4 x M20. Cable entry: no holes. Removable plug-in terminal strip. Wire max. 1.5mm2 and 2.5mm2. Weight 130 x 120 x 60mm (5.12" x 4.72" x 2.36") - W x H x D. 115 x 98mm (4.53" x 3.86") L x H. Die-cast aluminum panel mount enclosure IP65 / NEMA Type4X. 600 gr. GRP panel mount enclosure IP65 / NEMA Type4X, UV-resistant and flame retardant. 450 gr. Data protection Type Password EEPROM backup of all settings. Data retention at least 10 years. Configuration settings can be password protected. 10 F173 Digital outputs Hazardous area Intrinsically Safe (Type XI) ATEX certification IECEx certification Ambient Ta Function II 1 G Ex ia IIB/IIC T4 Ga. II 1 D Ex ia IIIC T100 °C Da. Ex ia IIC/IIB T4 Ga. Ex ia IIIC T100 °C Da. -40°C to +70°C (-40°F to +158°F). Type OA Type OR Type OS Explosion proof (Type XF) ATEX certification Type XF Weight Note II 2 G / Ex d IIB T5 Gb. II 2 D / Ex t IIIB T100 °C Db. Dimensions of enclosure: 300 x 250 x 200mm (11.8" x 9.9" x 7.9") L x H x D. Appr. 15kg. IECEx available on request. Type OT Note Operational Operator functions Signal inputs Level sensor Displayed functions Type A (0)4 - 20mA. Analog input signal can be scaled to any desired range within 0 - 20mA. Type U 0 - 10V DC. Analog input signal can be scaled to any desired range within 0 - 10V DC. Accuracy Resolution: 14 bit. Error < 0.025mA / ± 0.125% FS. Low level cut-off programmable. Span 0.000010 - 9,999,999 with variable decimal position. Offset -999,999 - +999,999 units. Update time Four times per second. Voltage drop Type A: 2.5V @ 20mA. Load impedance Type U: 3kOhm. Relationship Linear calculation. Note For signal type A and U: external power to sensor is required; e.g. type PD. Update time Type AA Type AB Type AF Type AI Type AP Type AU • Level and percentage. • Low-low alarm value. • Low alarm value. • High alarm value. • High-high alarm value. • Alarm values can be set (or only displayed). Level Digits Units Decimals Offset 7 digits. L, m3, GAL, USGAL, kg, lb, bbl, no unit. 0 - 1 - 2 or 3. User defined quantity. Height Digits Units Signal outputs Analog output Function Accuracy User defined: low, low-low, high, high-high or all alarms output. Three active 24V DC transistor outputs (PNP); max. 50mA per output (requires PD, PF, PM or PX). Two electro-mechanical relay outputs isolated (N.O.) max. switch power 230V AC - 0.5A (requires PF or PM) and one transistor output OT or OA. Four electro-mechanical relay outputs - isolated; max. switch power 230V AC - 0.5A per relay (requires AP and PD with 24V AC / DC). Three passive transistor outputs (NPN) - not isolated. Max. 50V DC - 300mA per output. Intrinsically Safe applications: only two transistor outputs type OT available. Decimals Transmitting linearized level. 10 bit. Error < 0.05%. Analog output signal can be scaled to any desired range. Eight times per second. Active 4 - 20mA output (requires PD, PF, PM or PX). Active 0 - 20mA output (requires PD, PF, PM or PX). Passive floating 4 - 20mA output for Intrinsically Safe applications (requires XI + PD or PX). Passive galvanically isolated 4 - 20mA output - also available for battery powered models. Passive 4 - 20mA output - not isolated. Unit will be loop powered. Active 0 - 10V DC output (requires PD, PF, PM or PX). 6 digits. mm, cm, m, mtr, inch, ft, mmwk, mmwc, cmwk, cmwc, mwk, mwc, inwc, ftwc, mbar, bar, psi, no unit. 0 - 1 or 2. Percentage Digits Decimals 4 digits. 1. Alarm values Function Digits Units Decimals Type of alarm Protection Four user defined alarm values to monitor the level. 7 digits. According to the settings for level. According to the settings for level. Low, high, low-low or high-high level alarm. Includes alarm ignore time and configurable alarm outputs. The alarm values can be password protected. Communication option Function Protocol Speed Addressing Type CB Type CH Type CI Type CT F173 Reading display information, reading / writing all configuration settings. Modbus RTU. 1200 - 2400 - 4800 - 9600 baud. Maximum 255 addresses. RS232 RS485 2-wire RS485 4-wire TTL Intrinsically Safe. Accessories Mounting accessories ACF02 ACF05 ACF06 ACF07 ACF08 ACF09 ACF11 11 Stainless steel wall mounting kit. Stainless steel pipe mounting kit (worm gear clamps not included). Two stainless steel worm gear clamps Ø 44 - 56mm. Two stainless steel worm gear clamps Ø 58 - 75mm. Two stainless steel worm gear clamps Ø 77 - 95mm. Two stainless steel worm gear clamps Ø 106 - 138mm. Swivel with 25° movement from center axis for direct flowmeter mounting: 1” NPT to 1/2” NPT Ordering information Standard configuration: F173-A-AP-CX-HC-OT-PX-XX-ZX. Ordering information: Level input signal A U (0)4 - 20mA input. 0 - 10V DC input. AA AB AF AI AP AU Active 4 - 20mA output - requires PD, PF, PM or PX. Active 0 - 20mA output - requires PD, PF, PM or PX. I.S. floating 4 - 20mA output - requires XI + PD or PX. Isolated 4 - 20mA output. Passive 4 - 20mA output, loop powered unit. Active 0 - 10V DC output - requires PD, PF, PM or PX. CB CH CI CT CX Communication RS232 - Modbus RTU. Communication RS485 - 2wire - Modbus RTU. Communication RS485 - 4 wire - Modbus RTU. Intrinsically Safe TTL - Modbus RTU. No communication. HB HC Aluminum enclosure. GRP enclosure. F173 -_ -A _ -C _ -H _ -O _ -P _ -X _ -Z _ Analog output signal Communication Panel mount enclosures - IP65 / NEMA Type4X GRP field / wall mount enclosures - IP67 / NEMA Type4X HD HE HF G H HH HJ HK Cable entry: no holes. Cable entry: 2 x Ø 16mm & 1 x Ø 20mm. Cable entry: 1 x Ø 22mm (7/8”). Cable entry: 2 x Ø 20mm. Cable entry: 6 x Ø 12mm. Cable entry: 3 x Ø 22mm (7/8”). Flat bottom, cable entry: no holes. Aluminum field / wall mount enclosures - IP67 / NEMA Type4X HA HL HM HN HO HP HT HU HV HZ Cable entry: 2 x PG9 + 1 x M20. Cable entry: 2 x 1/2”NPT. Cable entry: 2 x M16 + 1 x M20. Cable entry: 1 x M20. Cable entry: 2 x M20. Cable entry: 6 x M12. Cable entry: 1 x 1/2”NPT. Cable entry: 3 x 1/2”NPT. Cable entry: 4 x M20. Cable entry: no holes. OA OR OS OT Three active transistor outputs - requires PD, PF, PM or PX. Two mechanical relay outputs + one OT or OA - requires PF or PM. Four mechanical relay outputs - requires AP and PD. Three passive transistor outputs - standard configuration. PD PF PL PM PX 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC. 24V AC/DC + sensor supply. Input loop powered from sensor signal type “A” - requires AI and OT (not XI). 115 - 230V AC + sensor supply. Basic power supply 8 - 30V DC (no real sensor supply). PB PC Lithium battery powered - requires PD, PL or PX. Lithium battery powered - Intrinsically Safe - requires XI, and PD or PX. XI XF XX Intrinsically Safe, according ATEX and IECEx. Ex d enclosure - 3 keys according ATEX. Safe area only. ZB ZX Backlight. No options. Digital output signals Power requirements Additional battery supply (optional) Hazardous area The bold marked text contains the standard configuration. Available Intrinsically Safe. Specifications are subject to change without notice. Fluidwell bv P.O. Box 6 5460 AA - Veghel - The Netherlands Telephone: +31 (0)413 343 786 Telefax: +31 (0)413 363 443 email: [email protected] Internet: www.fluidwell.com 12 Copyright: Fluidwell bv - 2017 - F173-DATA-EN-V1704 Other options