* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download CSE-Semaphore Plus+ Manual
Power inverter wikipedia , lookup
Three-phase electric power wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Wireless power transfer wikipedia , lookup
Electric power system wikipedia , lookup
Alternating current wikipedia , lookup
Immunity-aware programming wikipedia , lookup
History of electric power transmission wikipedia , lookup
Audio power wikipedia , lookup
Power engineering wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Electrification wikipedia , lookup
Telecommunications engineering wikipedia , lookup
Phone connector (audio) wikipedia , lookup
Voltage optimisation wikipedia , lookup
Buck converter wikipedia , lookup
Power electronics wikipedia , lookup
Electrical connector wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Opto-isolator wikipedia , lookup
Power over Ethernet wikipedia , lookup
Mains electricity wikipedia , lookup
Power supply wikipedia , lookup
Home wiring wikipedia , lookup
Electrical wiring wikipedia , lookup
Kingfisher PLUS+ Installation Manual Document Information Document Control Copyright Copyright CSE-Semaphore (Australia) Pty Ltd. ABN 35 006 805 910 www.cse-semaphore.com/mykingfisher, [email protected] Intellectual Property CSE-Semaphore asserts ownership of the intellectual property contained herein and claims copyright and authorship. CSE-Semaphore has and retains all rights of ownership and use of the material herein in its on-going business. Licence This document is provided to the intended recipient(s) under a non-exclusive licence. This licence permits Fair Use of the document for operational requirements, without payment of further royalty or licence fee. Fair Use includes making copies of the document for operational, backup and archive purposes. Fair Use includes distributing copies of the document to other entities for the purposes of their performing related works for the intended recipient(s). Fair Use does not include creating, selling or distributing copies of the document for other purposes. All copies must retain this statement of Intellectual Property and Copyright. Revision History Rev.* Date Summary 1.7 1.8 29/1/2004 13/8/2004 1.81 2/9/2004 1.82 9/9/2004 1.9 2.0 23/8/2005 4/5/2006 2.1 2.2 26/10/2006 12/7/2007 2.3 17/4/2008 2.4 26/8/2008 2.5 10/9/2009 2.6 13/8/2010 Added DO-5 relay board wiring diagram. Added CDMA and satellite phone cables. Updated DO-5 relay board wiring diagram (new revision TEL REL 002). Removed AI-4 wiring diagram. Updated backplane terminators drawing (all terminators are now on for a single backplane). Renamed chapter 6 from Wiring Modules to Wiring Diagrams. Revision date for 1.81 was incorrect. Updated wiring drawing for ADP-16. Added RJC-ADP-17 cable. Updated RTUnet contact details. Added ADP-28 cable. Added battery warnings for PS11/21 wiring diagrams. Added ADP-08-M, ADP-29, RJC-ADP-30 and ADP-30 cables. Updated the RA Form. Added coaxial cable information. Added DO-5 wiring diagram. Kingfisher Series II is now called Kingfisher PLUS+. Removed revision history entries prior to 2004. RJC-ADP-26 is now used for a Maxon 3G modem (instead of a CDMA modem). Updated company name from RTUnet to CSESemaphore. Added wiring examples for AI-1, AI-10, IO-3 and IO-4. Updated DO-5 to DO6. Standardised format of electrical units. Updated enclosure layout drawing for preventing fire risk. Updated RA form to 21 November 2007. Updated GSM adaptor cable to RJC-ADP-22B. Updated Overview chapter. Removed cables for Trio radios and devices that are no longer available. Updated adaptor cable pictures. Updated AO-2 and PS-11 wiring diagrams. Updated contact details. Updated Backplane Setup chapter for new backplane connectors (applies to BA-x PLUS backplanes). Added Removable I/O Connector topic. Removed the resistance test for a new antenna installation. Added recommended wiring gauges. Added 7 AH battery holding bracket that can be used in enclosures. Added topic – 19” Rack Mounting. Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page 2 Contents 1. RTU Layout........................................................................................................4 2. Installing Modules............................................................................................. 5 3. Removable I/O Connector ................................................................................5 4. Backplane Setup ............................................................................................... 6 5. Enclosure Layout.............................................................................................. 7 5.1 6. Battery and GPO Bracket ...................................................................................................7 19” Rack Mounting ........................................................................................... 8 6.1 6.2 How To Mount a 12-Slot Backplane ...................................................................................8 How To Mount a Four Or Six Slot Backplane.....................................................................8 7. Installing Cables And Adaptors .......................................................................9 8. Wiring Diagrams ............................................................................................. 11 8.1 8.2 8.3 8.4 8.5 8.6 8.7 8.8 8.9 8.10 8.11 8.12 8.13 8.14 8.15 8.16 8.17 9. Analog Inputs....................................................................................................................11 AI-1 Wiring Diagram .........................................................................................................11 AI-10 Wiring Diagram .......................................................................................................12 AO-2 / AO-3 Wiring Diagram ............................................................................................13 DI-5 Wiring Diagram .........................................................................................................13 DI-10 Wiring Diagram .......................................................................................................14 DO-1 Wiring Diagram .......................................................................................................14 DO-2 Wiring Diagram .......................................................................................................15 DO-6 Wiring Diagram .......................................................................................................15 DO-6 Relay Board (TEL REL 002) Wiring Diagram .........................................................16 IO-2 Wiring Diagram .........................................................................................................17 IO-3 Wiring Diagram .........................................................................................................18 IO-4 Wiring Diagram .........................................................................................................19 PS-11 Wiring Diagram - AC Supply..................................................................................20 PS-11 Wiring Diagram - DC Supply .................................................................................20 PS-21 Wiring Diagram......................................................................................................21 PSU-3: Economy AC Input Power Supply (for PC-1).......................................................21 Solar Panel Installation ..................................................................................22 10. Level Probe Installation..................................................................................22 11. Antenna Installation........................................................................................23 11.1 11.2 Antenna Cable Selection And Installation ........................................................................24 How To Assemble Antenna Connectors...........................................................................24 12. Return Of Goods ............................................................................................. 25 Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page 3 1. RTU Layout The exact layout should be defined in layout and wiring drawings supplied with the RTU. If these have not been supplied, then the RTU layouts shown below can be used as a guide. Every RTU has a backplane (eg BA-4, BA-6), a power supply (eg PSU-3 or PS-11) and a processor module (eg PC-1 or CP-11). The two common types of RTUs are shown below. BA-4 PSU-3 PC-1 BA-6 PS11 CP11 12V DC MAINS POWER MAINS POWER An RTU can have additional communications ports (MC-11) and a wide variety of input/output modules (eg. IO-4, AI-1, DI-5). Some of these are shown below. BA-4 PSU-3 PC-1 MC11 IO-4 BA-6 PS11 CP-11 CP11 MC11 AI-1 DI-5 12V DC MAINS POWER MAINS POWER If a communications module is used, standard practice is to install it to the right of the processor. IO modules are usually installed in alphabetical order from left to right. Eg an AI-1 module would be located to the left of a DI-5 module. The modules can be installed in any order if so desired (except a PC-1 must be installed in the leftmost slot of a BA-4 backplane since it has two sockets). Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page 4 2. Installing Modules 3 Fasten screw to lock module 2 Press into socket onto backplane 1 Hook mounting tab onto backplane slot 3. Removable I/O Connector Each I/O module has a removable I/O connector. This allows the I/O module to be swapped without having to detach the field wiring from the I/O connector. The I/O connector is secured to the module using two fastening screws as shown below. I/O Connector Fastening Screw I/O Connector Fastening Screw Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page 5 4. Backplane Setup If a single backplane is being used then the switches on the backplane do not need to be changed. When linking two backplanes, please set the backplane switches as shown below (for backplane revisions 2.1, 2.2 and 3.2). A data cable is required to link the backplanes. If a backplane does not have its own power supply, a power cable will also be required to connect it to a powered backplane. The examples below show linking for BA-xx PLUS (revision 3.2) backplanes. When linking BA-xx PLUS backplanes (green Phoenix data connectors) with the older BA-xx backplanes (black Harwin data connectors), BAC-INT-0x data cables are used. These cables have a Phoenix connector on one end and a Harwin connector on the other. All data cables are straight through and do not contain crossovers. To link two older BA-xx backplanes, a BAC-0x data cable is used. BAC-PLUS-0x DATA CABLE Note: different rack numbers are required to avoid clashing of the slot addresses. Both backplanes are powered from the PC-1 in slot 13. The PC-1 is powered by a PSU-3 connected to the BA-4 BPC-0x POWER CABLE J13 PC-1 S LO T 13 16 J13 ON J14 SLOT 29 32 ON J14 BA-40 BA-4 RACK 1 RACK 2 BAC-PLUS-0x DATA CABLE Note:same rack numbers can be used since each backplane has different slot addresses (1 to 6 and 13 to 16). Both backplanes are powered using a PS-11 in any slot (typically slot 1) P S 1 1 BPC-0x POWER CABLE J13 PS-11 J14 S LO T 1 J13 ON SLOT 6 13 16 ON J14 BA-40 BA-6 RACK 1 RACK 1 Same settings apply for BA-12 BAC-PLUS-0x DATA CABLE Note: different rack numbers are required to avoid clashing of the slot addresses. J13 SLOT 1 12 SLOT BA-12 Each backplane requires its own PS-11/21 power supply module (typically installed in the left slot). Note: a single supply can be used to power both backplanes using a BPC-0x power cable if the total current load of the supply is not exceeded. Kingfisher PLUS+ Installation Manual 2.6 J13 ON RACK 1 17 ON 22 BA-6 P S RACK 2 Same settings apply for BA-12 1 1 www.cse-semaphore.com/mykingfisher Page 6 5. Enclosure Layout CAUTION! A RADIO SHOULD ONLY BE POWERED WHEN IT HAS AN ANTENNA CONNECTED. THIS WILL PREVENT DAMAGE TO THE RADIO IF IT TRANSMITS. All components of a Kingfisher PLUS+ RTU shall be installed inside of an enclosure providing safety and environmental protection. The enclosure shall be made from metal or other material with a flammability rating of V-0 or better in accordance with the requirements of the IEC 60950-1:2001 standard for a fire enclosure. An enclosure is not required to prevent fire hazard if the RTU is installed above concrete or other non-combustible surface. Examples of enclosure layouts are shown below. VENT MUST BE INSTALLED IF ENCLOSURE HAS A BATTERY. INSTALL A SECOND VENT IN LOWER RIGHT HAND CORNER IF BATTERY IS > 26 AH OR IF ENVIRONMENTAL CONDITIONS REQUIRE GREATER AIRFLOW. INSTALL BACKPLANE LOW ENOUGH TO ALLOW FOR AIRFLOW THROUGH MODULES. ENCLOSURE – RITTAL AE1045 500 HIGH x 400 WIDE x 210 DEEP mm RADIO OR MODEM. NOTE: RADIO CAN BE MOUNTED ON REAR OF DOOR BY USING DIN RAIL. ENSURE THAT THE RADIO IS MOUNTED ON THE TOP LEFT HAND CORNER OF THE DOOR TO ALLOW THE RADIO TO CLEAR THE RTU MODULES WHEN THE DOOR IS CLOSED. GEARPLATE PC-1 MC11 IO-3 PSU-3 IO WIRING TERMINALS SLOTTED DUCT DOUBLE GPO. ONE OUTLET FOR RTU. ONE OUTLET FOR LAPTOP 20 X 60 mm LIGHTNING ARRESTOR. INSTALL HIGH ENOUGH TO ALLOW EASY ACCESS FOR ANTENNA LEAD CONNECTION EARTH STUD. ENSURE GPO, BACKPLANE AND LIGHTNING ARRESTOR ARE CONNECTED TO THIS POINT USING APPROPRIATE EARTHING METHODS. BATTERY (MINIMUM 7 AH) BATTERY CAN REST ON BOTTOM OF ENCLOSURE OR A BATTERY BRACKET CAN BE USED 5 DEG ENCLOSURE MUST NOT CONTAIN OPENINGS IN THIS AREA TO AVOID FIRE RISK TO EXTERNAL ENVIRONMENT LEAVE AT LEAST 30 mm CLEARANCE TO ALLOW ROOM FOR GLANDS AND CABLES. 5 DEG CABLE GLANDS MOUNTED THROUGH GLAND PLATE 5.1 Battery and GPO Bracket When using a 7 AH backup battery, a standard battery holder is available from your RTU supplier. The bracket supports the battery and allows a General Power Outlet (GPO) to be mounted on the front using M3 x 10 mm pan head screws. The battery holder also allows an ISB50LN lightning arrestor to be mounted underneath. Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page 7 6. 19” Rack Mounting 6.1 How To Mount a 12-Slot Backplane A 12 slot backplane (BA-12) is mounted in a 19 inch rack using two MBR-3 mounting brackets. The MBR-3 brackets replace the surface mount brackets supplied with BA-12 backplanes. Installation Note: The holes in the MBR-3 brackets that are used to attach the brackets to the back of the backplane are drilled oversize to accommodate slight variances in racking equipment. By loosening these screws, pushing the brackets toward the centre of the backplane and then retightening the screws, the unit will fit freely into any correctly sized 19-inch rack. 6.2 How To Mount a Four Or Six Slot Backplane A four slot backplane (BA-4 or BA-40) or a six slot backplane (BA-6) is mounted in a 19 inch rack using a TEL-RAK-002 mounting bracket. One BA-6 or two BA-4/BA-40 backplanes can be attached to the TEL-RAK-002 using the surface mount brackets supplied with each backplane. The TEL-RAK-002 is supplied with eight M3 x 5 mm screws for attaching the backplane(s). 450 mm 222 mm 222 mm Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page 8 7. Installing Cables And Adaptors ADP-05 TOOLBOX OR SCADA CABLE RTU RJ45 RJ45 TO RJ45 PATCH CABLE RS232 PSTN MODEM Eg. Netcomm MyModem V.92 from www.netcomm.com.au ADP-07 RTU RJ45 TO RJ45 PATCH CABLE RJ45 RS232 NULL MODEM CABLE ADP-08 ADP-05 RJ45 TO RJ45 PATCH CABLE Spread Spectrum Radio XTend-PKG or XStream-PKG from www.digi.com ADP-08M RTU RJ45 RS232 RJ45 TO RJ45 PATCH CABLE TRIO D OR E SERIES RADIO RTU RJ45 TO RJ45 PATCH CABLE ADP-16 Kingfisher PLUS+ Installation Manual 2.6 RJ45 RS232 www.cse-semaphore.com/mykingfisher Page 9 GSM MODEM Eg. Fastrack Supreme from www.wavecom.com RTU RJ45 RS232 RJC-ADP-22B Maxon 3G Modem Modmax MM-6280IND from www.maxon.com.au RTU RJ45 RS232 RJC-ADP-26 TRIO M SERIES RADIO (eg. MR450) with MODEM FITTED RTU RJ45 TO RJ45 PATCH CABLE RJ45 RS232 ADP-29 TRIO M SERIES ANALOG RADIO (eg. MR450) with NO MODEM FITTED CP-xx MC-xx RJ45 LINE-2 LINE-2 POWER WIRE. CONNECT TO RADIO POWER +12 V RJC-ADP-30 TRIO M SERIES ANALOG RADIO (eg. MR450) with NO MODEM FITTED PC-1 MC-1 ADP-31 RJ45 TO RJ45 PATCH CABLE Kingfisher PLUS+ Installation Manual 2.6 RJ45 RADIO www.cse-semaphore.com/mykingfisher Page 10 8. Wiring Diagrams To Wire IO Modules Battery and 12 V power Use Wire Type 2 0.75 to 2.08 mm OR 18 to 14 AWG (American Wire Gauge) (Note: Fujicon IO terminal tension: 1 Nm) 2 2 2.5 to 4.0 mm OR 13 to 11 AWG. Use 4mm for > 2 m runs 8.1 Analog Inputs A combination of loop powered (2-wire) and self powered (3 or 4-wire) analog input transmitters can be used on the one module (AI-1, AI-10, IO-3 or IO-4). By default, each analog input is designed to accept 4 to 20 mA. Removing a link on the back of the module will allow 0 to 20mA operation for all channels of an AI-1, AO-2, IO-3 or IO-4. The current or voltage range for all channels of an AI-10 module is software configurable. 8.2 AI-1 Wiring Diagram 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 Wiring Examples +24 V Output CH x + Analog - Input 2-wire transmitter (powered by module) + Analog - Input 3-wire transmitter (powered by module) + Analog - Input 4-wire transmitter (powered by module) SHIELD CH 3 0V +24 V Ou tput CH 4 SHIELD 10 20 CH 1 0V +24 V Ou tput CH 2 CH 5 0V +24 V Ou tput CH 6 CH x 0V +24 V Output CH x 0V SHIELD +24 V Output CH 7 0V +24 V Ou tput CH 8 CH x PWR + Analog - Input SHIELD + 0V CH x + Analog Input PWR 0V CH x 0V + - + Analog - Input PWR + - Kingfisher PLUS+ Installation Manual 2.6 2-wire transmitter (powered externally) POWER SUPPLY 3-wire transmitter (powered externally) POWER SUPPLY 4-wire transmitter (powered externally) POWER SUPPLY www.cse-semaphore.com/mykingfisher Page 11 8.3 AI-10 Wiring Diagram Wiring Examples 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 CH 1+ CH 1CH 2+ CH 2CH 3+ CH 3CH 4+ CH 4+24 V Output 0V CH 5+ CH 5CH 6+ CH 6CH 7+ CH 7CH 8+ CH 8+24 V Output 0V +24 V Output CH x + CH x 0V + Analog - Input LOOP CH x + CH x 0V +24 V Output + Analog - Input CH x + CH x 0V +24 V Output + Analog Input CH x + 2-wire transmitter * (powered by module) 3-wire transmitter * (powered by module) PWR 4-wire transmitter (powered by module) PWR + Analog - Input 2-wire transmitter (powered externally) + CH x - CH x + + Analog Input PWR CH x - CH x + CH x - + - + Analog Input PWR + - POWER SUPPLY 3-wire transmitter (powered externally) POWER SUPPLY 4-wire transmitter (powered externally) POWER SUPPLY * When using the +24V output to power a transmitter, the negative input terminal of the analog input channel (2, 4, 6, 8, 12, 14, 16 or 18) must be wired to the OV terminal (10 or 20). This will complete the current loop due to electrical isolation between the input channel and the module +24V supply. Note: Any channels sharing the same power source (e.g. +24V from module or a field power supply) are no longer isolated from one other. Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page 12 8.4 AO-2 / AO-3 Wiring Diagram 1 2 CH 1+ CH 1- 3 4 5 6 7 SHIELD CH 2+ CH 2- Wiring Example + Analog - Output CH x + CH x SHIELD 4-20 or 0-20 mA Current Load 8 9 10 11 12 SHIELD CH 3+ CH 3- 13 14 15 16 17 SHIELD CH 4+ CH 4- 18 19 20 SHIELD 8.5 DI-5 Wiring Diagram Wiring Examples 1 2 3 4 5 6 INTERNAL CIRCUITRY 7 8 9 10 11 12 13 14 15 16 17 18 19 20 CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 +12V Ou tput 0V / Common CH 9 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16 +12V Ou tput 0V / Common Kingfisher PLUS+ Installation Manual 2.6 FIELD CONTACT CH x +12V Powered by module FIELD CONTACT CH x + POWER SUPPLY 0V External power supply Note: polarity can be reversed. www.cse-semaphore.com/mykingfisher Page 13 8.6 DI-10 Wiring Diagram Wiring Examples CH 1 CH 2 1 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 +12V Ou tput 0V / Common CH 9 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16 +12V Ou tput 0V / Common 3 4 5 6 INTERNAL CIRCUITRY FIELD CONTACT 7 8 9 10 11 12 13 14 15 16 17 18 19 20 CH x +12V Powered by module FIELD CONTACT CH x + External power supply AC or DC* POWER SUPPLY 0V / Common * DC voltage applied to input channel must be more positive than the common DC pow ered inputs and AC powered inputs can both be used on the one module. Care should be taken to ensure that the negative rail of each external power supply is connected to the DI-10 0V / Common ter minal. 8.7 DO-1 Wiring Diagram Wiring Example INTERNAL CIRCUITRY 1 NO 3 NC NO NC 2 4 7A 5 6 7 8 9 7A 10 11 12 13 14 7A 15 16 17 18 19 7A 20 CH 1 CH x POWER SUPPLY CH 2 COMMON 1 NO CH 3 NC NO CH 4 NC LOAD COMMON + External Power Supply. Note: polarity can be reversed. COMMON 2 NO CH 5 NC NO CH 6 NC COMMON 3 NO CH 7 NC NO CH 8 NC COMMON 4 Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page 14 8.8 DO-2 Wiring Diagram 1 2 3 4 5 6 7 8 7A 9 11 12 13 14 15 16 17 18 19 CH x LOAD COMMON POWER SUPPLY + External Power Supply. Note: polarity can be reversed. CH 9 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16 COMMON 2 LINK * 20 INTERNAL CIRCUITRY Wiring Example LINK * 10 7A CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 COMMON 1 * Optional link for DC SUPPLY ONLY. Enables fuse fail LED ‘FU’ on module. CAUTION! When links are installed, a maximum voltage of 30V AC or DC can be used to power the common. 8.9 DO-6 Wiring Diagram 1 2 3 4 5 6 INTERNAL CIRCUITRY 7 8 9 10 11 12 13 14 15 16 17 18 19 20 CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 0V 0V CH 9 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16 +12V Output +12V Output Kingfisher PLUS+ Installation Manual 2.6 Wiring Examples CH x LOAD + + POWER SUPPLY 0V CH x LOAD + External DC Power Supply Load powered by DO-5 module +12V Output When output is energised, output channel is shorted to the 0V terminal. 12V Output is sourced from the backplane power rail. This output is not isolated. Care should be exercised to avoid shorting or overloading this output. www.cse-semaphore.com/mykingfisher Page 15 8.10 DO-6 Relay Board (TEL REL 002) Wiring Diagram CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 CH 9 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16 Terminal Layout For Each DO-5 Channel NO - Normally open contact C - Common NC - Normally closed contact Each channel has 3 relay contacts (NO,C,NC) connected to two 3-way terminal blocks Wiring Example When the output channel is set ON, the load is energised NO LOAD POWER SUPPLY C Kingfisher PLUS+ Installation Manual 2.6 + External Power Supply. Note: polarity can be reversed. www.cse-semaphore.com/mykingfisher Page 16 8.11 IO-2 Wiring Diagram Wiring Examples 1 2 3 4 5 6 7 8 INTERNAL CIRCUITRY 9 10 11 12 13 14 15 16 17 18 10A 19 20 DI CH 1 FIELD CONTACT DI CH 2 DI CH x + External power DI CH 3 POWER supply. DI CH 4 SUPPLY Note: polarity can DI 0V DI CH 5 be reversed. DI CH 6 DI CH 7 DI CH 8 DI 0V / Common DO CH x LOAD External Power DI 0V / Common Supply POWER DO CH 1 SUPPLY Note: polarity can be DO CH 2 DO + reversed. Common DO CH 3 DO CH 4 DO CH 5 DO CH 6 DC pow ered inputs and low voltage AC inputs can both be used DO CH 7 on the one module. DO CH 8 DO Common LINK * * Optional link for DC SUPPLY ONLY. Enables fuse fail LED ‘FU’ on module. CAUTION! When link is installed, a maximum voltage of 30V AC or DC can be used to power the common. Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page 17 8.12 IO-3 Wiring Diagram There are three separate isolated groups, one for the analog input/output, one for the digital input and one for the digital output. Each group may be powered from a separate source. Wiring Examples 1 2 3 4 5 6 7 8 9 10 11 12 INTERNAL CIRCUITRY 13 14 15 16 17 18 7A 19 20 AI CH 1 AI CH 2 AI CH 3 AI CH 4 0V +24 V Ou tput AO + AO SHIELD DI CH 1 DI CH 2 DI CH 3 DI CH 4 DI Common DO CH 1 DO CH 2 DO CH 3 DO CH 4 DO Common LINK * * Optional link for DC SUPPLY ONLY. Enables fuse fail LED ‘FU’ on module. CAUTION! When link is installed, a maximum voltage of 30 V AC or DC can be used to power the common. Analog + Input 2-wire transmitter (powered by module) AI CH x 0V +24 V Output + Analog - Input 3-wire transmitter (powered by module) AI CH x 0V +24 V Output + Analog - Input 4-wire transmitter (powered by module) AI CH x +24 V Output AI CH x PWR + - + - 0V AI CH x + Analog Input PWR 0V AI CH x 0V 2-wire transmitter (powered externally) Analog Input 3-wire transmitter (powered externally) + POWER SUPPLY + Analog - Input PWR 4-wire transmitter (powered externally) + POWER SUPPLY AO + AO - POWER SUPPLY + Analog - Output Current Load FIELD CONTACT DI CH x +24 V Output DI Com. 0V Powered by module Link FIELD CONTACT DI CH x + POWER SUPPLY LOAD POWER SUPPLY DO Common Kingfisher PLUS+ Installation Manual 2.6 External power supply. Note: polarity can be reversed. DI Common DO CH x DC pow ered inputs and low voltage AC inputs can both be used on the one module. + External Power Supply. Note: polarity can be reversed. www.cse-semaphore.com/mykingfisher Page 18 8.13 IO-4 Wiring Diagram There are three separate isolated groups, one for the analog input, one for the digital input and one for the digital output. Each group may be powered from a separate source. Analog input channel 1 can be factory modified to support a strain gauge input. Wiring Examples 1 2 3 4 5 6 7 8 9 10 11 12 13 14 INTERNAL CIRCUITRY 15 16 17 18 7A 19 20 +E (optional) -E (optional) AI CH 1 or -S +S (optional) AI CH 2 0V +24 V Ou tput DI CH 1 DI CH 2 DI CH 3 DI CH 4 DI CH 5 DI CH 6 DI CH 7 DI CH 8 DI Common DO CH 1 DO CH 2 DO Common LINK * * Optional link for DC SUPPLY ONLY. Enables fuse fail LED ‘FU’ on module. CAUTION! When link is installed, a maximum voltage of 30 V AC or DC can be used to power the common. +E (5 V) -E (0 V) -S +S Strain gauge input (special order only) 0-50 mV Analog + Input 2-wire transmitter (powered by module) AI CH x 0V +24 V Output + Analog - Input 3-wire transmitter (powered by module) AI CH x 0V +24 V Output + Analog - Input 4-wire transmitter (powered by module) AI CH x +24 V Output AI CH x PWR + - + - 0V AI CH x + Analog Input PWR 0V AI CH x 0V 2-wire transmitter (powered externally) Analog Input 3-wire transmitter (powered externally) + POWER SUPPLY + Analog - Input PWR POWER SUPPLY 4-wire transmitter (powered externally) + POWER SUPPLY FIELD CONTACT DI CH x +24 V Output DI Com. 0V Powered by module Link FIELD CONTACT DI CH x + POWER SUPPLY LOAD POWER SUPPLY DO Common Kingfisher PLUS+ Installation Manual 2.6 External power supply. Note: polarity can be reversed. DI Common DO CH x DC pow ered inputs and low voltage AC inputs can both be used on the one module. + External Power Supply. Note: polarity can be reversed. www.cse-semaphore.com/mykingfisher Page 19 8.14 PS-11 Wiring Diagram - AC Supply PS-11 OFF + 24 VDC AUXILIARY OUTPUT (OPTIONAL) + 13.8 VDC OUTPUT (FOR RADIO OR OTHER DEVICE) GREY WITH BLACK STRIPE VA+ VAR+ RTS B+ B- TEMPERATURE SENSOR + BACKUP BATTERY # CAUTION! Connecting the battery in reverse may cause damage to the power supply. ACTIVE (+) NEUTRAL (-) EARTH A N E 100-240 VAC 96-340 VDC # TAPE OR CABLE TIE TEMPERATURE SENSOR TO NEGATIVE BATTERY TERMINAL (OR AS CLOSE AS POSSIBLE). CONNECT BLACK STRIPED WIRE OF SENSOR TO R- OR B- 8.15 PS-11 Wiring Diagram - DC Supply A low voltage DC supply can be fitted to the battery input terminals or a higher voltage DC supply can be fitted to the AC input circuit. PS-11 OFF VA+ VAR+ RTS B+ B- A N E + + - 24 VDC AUXILIARY OUTPUT (OP TIONAL) 13.8 VDC OUTPUT (FOR RADIO OR OTHER DEVICE) + - 12 VDC SUPPLY (NOMINAL) (MUST BE ISOLA TED FROM FIELD SUPPLY ) + - 96 TO 340 VDC SUPPLY (ALTERNA TIVE TO USING BATTERY TERMINALS) Kingfisher PLUS+ Installation Manual 2.6 CAUTION! Connecting the DC Supply in reverse may cause damage to the PS-11. www.cse-semaphore.com/mykingfisher Page 20 8.16 PS-21 Wiring Diagram PS-21 OFF + 24 VDC AUXILIARY OUTPUT (OPTIONAL) + 13.8 VDC OUTPUT (FOR RADIO OR OTHER DEVICE) GREY WITH BLACK STRIPE VA+ VAR+ RTS B+ B- TEMPERATURE SENSOR + BACKUP BATTERY E + EARTH - SUPPLY + SUPPLY # CAUTION! Connecting the battery in reverse may cause damage to the power supply. 20 TO 60 VDC INPUT SUPPLY * *A NEGATIVE DC INPUT SUPPLY CAN BE USED. CONNECT THE MORE POSITIVE WIRE (eg 0 V) TO +SUPPLY AND CONNECT THE MORE NEGATIVE WIRE (eg -48 V) TO -SUPPLY. # TAPE OR CABLE TIE TEMPERATURE SENSOR TO NEGATIVE BATTERY TERMINAL (OR 37.5 AS CLOSE AS POSSIBLE). CONNECT BLACK STRIPED WIRE OF SENSOR TO R- OR B- 8.17 PSU-3: Economy AC Input Power Supply (for PC-1) +V and –V are wired to pins 7 and 8 (12V Supply Input) of the orange BL9 connector on the BA-4 backplane. +V A N E -V 1 2 3 4 5 Voltage Adjust (13.8V) BA-4 +12V Supply Input 0V Supply Input Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page 21 9. Solar Panel Installation L Ensure panel will not be shaded by trees etc R LA O S NE PA LATTITUDE OF SITE TILT ANGLE ‘A’ 0-4 Deg 5-20 Deg 21-45 Deg 45-65 Deg 65-75 Deg 10 Deg Add 5 Deg to local lattitude Add 10 Deg to local lattitude Add 15 Deg to local lattitude 80 Deg Eg Sydney, Australia has a lattitude of 33 Deg. Therefore tilt angle = 43 Deg. A Set to face due South when in northern hemisphere and set to face due North when in southern hemisphere 10. Level Probe Installation Hang level probe near access hatch RTU Connect level probe to analog input Hang level probe (Eg. Platypus from www.ecefast.com.au) 100mm above floor of tank (above sludge) Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page 22 11. Antenna Installation N TYPE MALE * N TYPE FEMALE * ANTENNA MOUNTING CLAMP B ANTENNA CONNECTION TO BE SEALED WITH SELF AMALGAMATING TAPE CABLE MAINTENANCE LOOP CABLE TIE DRAIN HOLE TO BOTTOM WHEN MOUNTED VERTICALLY TO TEST USING A MULTIMETER (WITH CONNECTORS INSTALLED): 1. TEST FOR OPEN CIRCUIT BETWEEN THE CENTRE PIN AND THE CASE OF CONNECTOR A WITH THE ANTENNA DISCONNECTED: B FASCIA MOUNT HOCKEY STICK ANTENNA MAST COACH SCREWS AIM ANTENNA AT REPEATER OR AT MASTER RTU. SHOULD HAVE LINE OF SITE. USE COMPASS TO AIM WHERE NECESSARY A OPEN CIRCUIT? NO ANTENNA 2. TEST FOR SHORT CIRCUIT BETWEEN THE CENTRE PIN AND THE CASE OF CONNECTOR A WITH A SHORT CIRCUIT AT CONNECTOR B (CAN USE AN ALIGATOR CLIP FOR THE SHORT) B A SHORT CIRCUIT? ANTENNA CABLE. SHORT CIRCUIT NOTE: A THOROUGH ANTENNA TEST REQUIRES A WATTMETER. WHEN RADIO IS TRANSMITTING, CHECK: REVERSE POWER = 0W FORWARD POWER > 0W A USE N TYPE MALE WHEN CONNECTING TO LIGHTNING ARRESTOR OR USE BNC MALE WHEN CONNECTING STRAIGHT TO RADIO* (A LIGHTNING ARRESTOR IS HIGHLY RECOMMENDED) * Wiring of antenna connectors is detailed in the next section. Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page 23 11.1 Antenna Cable Selection And Installation Recommendations: Only use RG58 within an enclosure or within a building and if the cable run is less than 5 metres. The cable is too fragile and the cable loss is too high for outside longer cable runs. Typically use RG213 up to 10 metres. This suits 6 metre water pipes that are commonly used for antenna masts. After 10 metres it becomes a question of how much signal loss can be tolerated. LDF4 or LDF5 have lower signal loss per metre as listed below. Minimise the number of connections in the cable run – connections have a great deal of loss. Loss per m of coax (@450MHZ) Loss per m of coax (@900MHZ): RG58 0.44 dB RG58 0.60 dB (Do not use!) RG213 0.16 dB RG213 0.24 dB LDF4 0.05 dB LDF4 0.07 dB LDF5 0.03 dB LDF5 0.04 dB 11.2 How To Assemble Antenna Connectors The following instructions apply to all three connectors: 1. Place clamp nut and plain gasket over cable. 2. Trim outer sheath from cable to dimension shown. 3. Fold back braid and insert ferrule to trap braid between outer sheath and ferrule. 4. Trim off surplus braid. 5. Trim dielectric to dimension shown, and check that exposed centre conductor length is as specified. 6. Tin centre conductor. 7. Slide rear insulator over dielectric to butt against ferrule. 8. Mount contact (male for plugs, female for jacks) over centre conductor with shoulder pressed against rear insulator. 9. Hold cable and contact firmly together, and solder. 10. Slide plain gasket and clamp nut up to ferrule, trapping braid. 11. Fit front insulator over contact to butt against rear insulator. 12. Press sub-assembly into body as far as possible and engage clamp nut. 13. Holding body and cable rigid, tighten clamp nut to compress plain gasket and retain cable. Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page 24 RG213 To BNC RG213 To N-Type RG58 To N-Type 12. Return Of Goods If you would like to return RTU modules or equipment for testing or repair, please carry out the following steps: Request a Return Authorisation (RA) number from your Kingfisher representative Complete all details on a RA form (please use the supplied form as a master copy or download one from the Semaphore web site) Return RA form with goods Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page 25 RETURN AUTHORISATION RETURN AUTHORISATION NUMBER RETURNS PROCEDURE 1. Request an RA No. from CSE-Semaphore Australia Pty Ltd 2. Complete all details on form then fax copy to CSE Semaphore 3. Return form with goods to address shown on right CSE-Semaphore Australia Pty Ltd Unit 8, 3-5 Gilda Court MULGRAVE, VICTORIA 3170, AUSTRALIA PH: (61) 3 8544 8544 FAX: (61) 3 8544 8555 ABN: 006 805 910 PLEASE NOTE: Goods can only be repaired when accompanied by an RA Form with all details completed CUSTOMER DATE: / / DELIVERY ADDRESS PHONE No: ( ) FAX No: ( ) ORDER NO: TECHNICAL CONTACT: PREFFERED COURIER: Please note, customer pays freight both ways PART NO SERIAL NO PROBLEM - Please provide as much detail as possible INTERNAL USE ONLY FACTORY WARRANTY Goods are under warranty for twelve months only from date of shipment, unless otherwise arranged by contract. Please note that goods are not co vered under warranty when subjected to improper use. If goods are under warranty, please complete the following otherwise goods will be charged for. DATE PURCHASED YOUR ORDER NO. 21 November 2007: Installationmanual.Doc INTERNAL USE ONLY