Download Guide to selecting a power supply

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Stray voltage wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Islanding wikipedia , lookup

Power factor wikipedia , lookup

Electrical substation wikipedia , lookup

Power inverter wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Three-phase electric power wikipedia , lookup

Wireless power transfer wikipedia , lookup

Audio power wikipedia , lookup

Standby power wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Buck converter wikipedia , lookup

Opto-isolator wikipedia , lookup

Rectifier wikipedia , lookup

Electrification wikipedia , lookup

Electric power system wikipedia , lookup

Distribution management system wikipedia , lookup

Surge protector wikipedia , lookup

History of electric power transmission wikipedia , lookup

Power over Ethernet wikipedia , lookup

Voltage optimisation wikipedia , lookup

Power engineering wikipedia , lookup

Alternating current wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Mains electricity wikipedia , lookup

Power supply wikipedia , lookup

AC adapter wikipedia , lookup

Transcript
Guide to selecting a power supply
The PS900 Series provides a variety of flexible options allowing you to design custom
solutions to address a broader range of applications. This brief guide will help you configure
the proper solution based on the unique characteristics of your opening. If at any point in
the system design or installation process you need assistance, you can turn to the security
and safety consultants at Allegion for support.
1.
Sizing a supply
Simple as they may seem, power supplies play a critical role in your access
control system. They protect devices downstream by providing filtered and
regulated power. To begin with you must determine the number of devices that
will be connected to the power supply and the type of device - electric strikes,
electromagnetic locks, electrified mechanical locks, exit devices, automatic
operators or accessories such as pushbuttons. Each type of device has specific
current demands. For example, high in-rush exit devices pull a significant current
to retract or unlock the device and then drop to a lower holding current. If a
device has an in-rush current you also need to determine how long the in-rush
current lasts.
Power supplies convert high voltage AC power into the low voltage DC outputs
required by most access control devices. Begin by checking the input voltage
to ensure that it is compatible with your buildings source AC power. The PS900
Series, for example, features a universal 120-240 VAC input. All devices fed from a
power supply must accept the same output voltage – typically 12 VDC or 24 VDC.
To calculate the total load, add the peak current draw of all devices in the system
to determine the required amperage of the supply.
Quick survey
Gather the following information to
determine the necessary size of the
power supply:

Number of devices

Type of devices

In-rush current requirements

Duration of in-rush current
Calculate the peak current draw of all
devices in the system to determine the
required amperage of the supply.
PS902 - up to 2 amps
PS904 - up to 4 amps
PS906 - up to 6 amps
Electric strikes
Electrified
mechanical devices
Electronic locks



Card readers/
Biometrics
Sizing a supply
Allegion • Guide to selecting a power supply
Allegion product
Current draw
Voltage
PR10
110 mA
Linear: 5 - 16VDC
SM10
195 mA
Linear: 5 - 16VDC
MT11
170 mA
Linear: 5 - 16VDC
MT15
200 mA
Linear: 5 - 16VDC
MTK15
230 mA
Linear: 5 - 16VDC
HandKey II
12V AC/DC - 580 mA
24V AC/DC - 300 mA
12 to 24VDC
12 to 24VAC 50-60Hz
AD-300
250 mA
12VDC or 24VDC
PIM400-TD2
250 mA
12VDC or 24VDC
PIM400-485
250 mA
12VDC or 24VDC
PIB300-2D
250 mA
12VDC or 24VDC
PIM400-1501
400 mA
PoE 802.3af compliant
power injector
WRI400
500 mA
12VDC or 24VDC
REPTR400
500 mA
12VDC or 24VDC
ECK/GCK400
500 mA
12VDC or 24VDC
CT5000
250 mA
12VDC or 24VDC
ND Series
24VAC - 350 mA
24VDC - 150 mA
24VDC or 24 VAC
L Series
Peak - 1.3 A,
5 - 10 second intervals
Holding - 135mA
between peak intervals
24VDC or 24 VAC
QEL
1.4 A inrush (0.5 sec)
0.14 A Holding
2.0 A calibration
24VDC
E996L
98/99 Series trim
0.22 A
24VDC
E360L
33A/35A Series trim
.50 A
24VDC
DE5101
24VDC - 300mA without
maglocks
24VDC
E7500
12VDC - 600 mA
24VDC - 300 mA
12VDC or 24VDC
EL 1
16 A inrush (0.5 sec)
0.3 A holding current
24VDC
Chexit/RCM 1
16 A inrush (arming 0.5 sec)
0.4 A continuous
24VDC
5100 Series
12VDC - 0.38 A
24VDC - 0.19 A
12VDC or 24VDC
field selectable
6100 Series
12VDC - 0.6 A
24VDC - 0.33 A
12VDC or 24VDC
6200 Series
12VDC - 0.6 A
24VDC - 0.33 A
24VDC standard
12VDC and AC optional
6300 Series
12VDC - 0.5 A
24VDC - 0.24 A
12VDC or 24VDC
field selectable
6400 Series
12VDC - 0.375 A
24VDC - 0.190 A
12VDC or 24VDC
field selectable
4200 Series
12VDC - 0.20 A
24VDC - 0.10 A
30VDC - 0.20 A
12VDC or 24VDC
field selectable
Electromagnetic locks
Allegion product
Current draw
Voltage
M420/M450
12VDC - 0.75 A
24VDC - 0.38 A
12VDC or 24VDC
M490
12VDC - 0.65 A
24VDC - 0.35 A
12VDC or 24VDC
40
12VDC - .32 A
24VDC - 0.15 A
12 VDC - 0.25 A
24VDC - 0.12 A
12VDC - 0.50 A
24VDC - 0.25 A
12VDC or 24 VDC
320M
12VDC - 0.45 A
24VDC - 0.23 A
12VDC or 24VDC
GF3000
12VDC - 0.90 A
24VDC - 0.45 A
12VDC or 24VDC
390RFK
12VDC - 0.65 A
24VDC - 0.45 A
12VDC or 24VDC
70
72
Note:
 All devices fed from a power supply must accept the same output voltage.
 Battery powered devices not included in above reference table. Please refer to data sheets for more information.
2. Choosing option boards
Check for fire door labels on the door and frame. If an opening is fire rated
code requires that the door have positive latching, which fail-secure hardware
provides.

Fail-secure hardware is locked when power is removed. Power is applied to
unlock the door.

For applications, such as stairwell re-entry doors, where access is required
upon fire alarm, fail-safe hardware is applied. Fail-safe hardware is unlocked
when power is removed. Power is applied to lock the door.
Quick survey
Identify if the opening is fire rated
or has special requirements, such
as re-entry upon fire alarm. Then
identify if it requires hardware
for fail-safe, fail-secure, or both
conditions upon loss of power or
fire alarm. Always consult your
local AHJ for requirements of the
opening if it is unclear.
The PS900 Series offers the 900-FA option board which cuts power to
downstream devices when the fire alarm is activated to allow for
fail-safe/fail-secure conditions. For the PS902 the 900-FA board can be
connected directly to the main printed circuit board (PCB) on the supply. For the
rest of the PS900 Series power supplies the 900-FA board must be connected
to another option board.

900-FA: Emergency interface relay integrates with fire alarm and is used to
cut power in case of emergency
3.Application
Quick survey
The PS900 Series allows you to address a wide range of applications with
options boards that can be combined and configured in countless ways. A
complete operational description of the opening is essential. How many doors
are there? Is logic or sequencing required?
Provide a complete operational
description of the opening.

900-4R: 4 independently controlled relays to power multiple devices

900-2RS: 2 relay EL panic device control board providing time delay
between the firing of the outputs

900-4RL: 4 relay board with integrated logic for controlling security
interlocks, auto operators and time delays

900-8F: 8 individually fuse protected outputs, giving the flexibility to power
multiple devices and provide another layer of protection

900-8P: 8 positive thermal coefficient (PTC) protected outputs
Allegion • Guide to selecting a power supply
6. Battery back up
Quick survey
Upon loss of building power it is important that your access control devices still
function properly. The 900-BBK board provides up to four hours of backup power
at the same output voltage as the power supply. There is a dedicated location on
the supply for the 900-BBK board that nothing else can go on so in most cases it
does not take away space from other option boards. The exception to this is the
PS906. The PS906 can accommodate: a.) two option boards and a 900-BBK kit,
or b.) three option boards and no 900-BBK kit.

Is access control still required in
the event of a power outage:
Yes
No
900-BBK: Battery backup kit (includes battery backup board and two 7A/hr.
batteries) and provides up to four hours of backup power when cycled every 5
minutes at full load
Number of connectors
PS902 1
(2 amps)
PS904 1
(4 amps)
PS906 1
(6 amps)
Option boards
1
2
32
Battery backup board
1
1
1
1 One fire alarm board can be connected directly to the PS902. If a fire alarm board is desired for the PS904 or PS906 it
must be connected to an option board.
2 If battery back-up is installed, only two additional option boards can be used.
Allegion, the Allegion logo, Von Duprin, and the Von Duprin logo are trademarks of Allegion plc, its subsidiaries and/or
affiliates in the United States and other countries. All other trademarks are the property of their respective owners.
About Allegion
Allegion (NYSE: ALLE) creates peace of mind by pioneering safety and security. As a
$2 billion provider of security solutions for homes and businesses, Allegion employs
more than 8,000 people and sells products in more than 120 countries across the
world. Allegion comprises 27 global brands, including strategic brands CISA®, Interflex®,
LCN®, Schlage® and Von Duprin®. For more, visit www.allegion.com.
© 2014 Allegion
010491, Rev. 09/14
www.allegion.com/us