* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download ACT20M Presentation - Weidmuller B2B Portal
Standby power wikipedia , lookup
Power inverter wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Voltage optimisation wikipedia , lookup
Electric power system wikipedia , lookup
Flip-flop (electronics) wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electrification wikipedia , lookup
Audio power wikipedia , lookup
Alternating current wikipedia , lookup
Wireless power transfer wikipedia , lookup
Mains electricity wikipedia , lookup
Power over Ethernet wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Power engineering wikipedia , lookup
Schmitt trigger wikipedia , lookup
Buck converter wikipedia , lookup
Control system wikipedia , lookup
Power supply wikipedia , lookup
ACT20M 6mm Signal Isolators and Converters ACT20M – 1 & 2 channels in 6mm width ! Phase 1…..10 models – isolators & converters Power rail option – minimizes cabling time Hazardous approvals (Class 1 Div 2, Zone 2 ATEX) Includes 2 channel options – in 6mm width ! DIP switch settable - except UI (computer configurable) Wide ambient -25 to 70C part no. 1176070000 1176080000 1176040000 1176050000 1176030000 1175980000 1176000000 1176010000 1175990000 1176020000 Description ACT20M-CI-CO-ILP-S ACT20M-2CI-2CO-ILP-S ACT20M-CI-CO-OLP-S ACT20M-2CI-2CO-OLP-S ACT20M-UI-AO-S ACT20M-CI-CO-S ACT20M-AI-AO-S ACT20M-AI-AO-E-S ACT20M-CI-2CO-S ACT20M-AI-2AO-S ACT20M training Function 1 channel passive current isolator 2 channel passive current isolator 1 channel OLP isolator 2 channel OLP isolator Universal input converter/isolator 1 channel current isolator 1 channel convertor/isolator - DIP selectable Economy Convertor/isolator - DIP selectable Current Splitter/isolator Current/voltage Splitter/isolator Power Input loop Input loop Output loop Output loop Auxiliary Auxiliary Auxiliary Auxiliary Auxiliary Auxiliary Page 2 From MAS to ACT20M…. Questions and Answers What does the name mean? ACT20M Analog Conditioner Transmitter IP20 Micro Why a new product family? ACT20M replaces and expands the existing MICROANALOG series – the functionality of which is limited by having only 6 terminals. ACT20M has 8. Will MAS range be replaced? Some overlap exists - but probably not, as ACT20M is for process customers, whereas MAS has been mainly for factory / machinery customers. When will ACT20M products be available? There are 10 variants. End November 2011 we have 6 variants in Richmond stock. Seite 3 ACT20M training More performance in 6mm ! Expansion with 3 new functions Dual OLP Isolators, Universal Converter in 6mm, Aux powered Splitters Replacement and Improvement of the existing MAS DC/DC select Splitter with sensor supply - Aux power permits power for 2-wire transmitter Wide temperature range: -25…+70°C operating temperature High galvanic isolation 300 V rated voltage, 2,5 kV test voltage Worldwide application international approvals cULus, ATEX Zone 2, FM-Div. 2,, GL, DNV Quick and easy configuration by DIP-Switches or FDT/DTM Software Power supply via DIN-Rail-Bus 24 V supply via DIN-Rail Seite 4 ACT20M training High accuracy of up to 0,05% Who are the target customers for ACT20M? Process Industries, e.g…. Oil & Gas (Production and transmission) Chemicals and Petro-chem Power, Paper & Pulp Iron & Steel, Cement Customers are: Systems Integrators Plant end-users (above) Package plant OEMs (separators, dryers, coolers, effluent treatment, chemical dosing, pumping) Page 5 ACT20M training How does ACT20M compare? Weidmuller Phoenix Red Lion Omron WAGO ACT20M MINI MCR AIMA/IAMA/AFCM K3FP Series Series 857 10 14 3 10 9 Screw / Tension Screw Screw / Tension Screw Screw Tension Power rail option Yes Yes No Yes No Approvals - Normal cULus, CE, DNV, GL cULus, CE, GL cULus, CE, GL UL 508 CE, cULus, GL (pending) Approvals - Hazloc FM Div2, ATEX Zone 2 Typ. FM Div2 Typ. FM Div2 None Div 2 -25 to 70C -20 to 60C -20 to 60C -20 to 65C -20 to 70C (/50C) 2.5kV 1.5kV 1.5kV 1.5kV 2.5kV No. of models Ambient temperature Isolation ACT20M training Page 6 Typical application – ACT20M-AI-2AO-S Hazardous Area Safe Area Division 2 or Zone 2 area Power supply, e.g. CP T SNT 90W 24V 3.8A a.c. Local display DI350 Remote PLC DC power for tx P S + 0–5V output 1 4-20mA input from tx Level transmitter Input O/P 1 O/P 2 PLC and display have passive inputs 4-20mA output 2 ACT20M-AI-2AO-S Use where the splitter’s receivers have passive inputs ACT20M training Page 7 Typical application – ACT20M-CI-2CO-S Hazardous Area Safe Area Division 2 or Zone 2 area Power supplies, e.g. CP T SNT 90W 24V 3.8A Local loop-powered display DI350 Remote PLC P S 4-20mA output 1 4-20mA input from tx Level transmitter Input O/P 1 O/P 2 PLC and display have passive inputs 4-20mA output 2 ACT20M-CI-2CO-S Use where all signals are mA, and the isolator’s receivers have passive inputs ACT20M training Page 8 Typical application.... ACT20M-CI-CO-S Control room PLC +24Vdc +24Vdc In-head 2-wire tx DC Power Supply DC power for tx Passive input P S 4-20mA 4-20mA Input O/P Heat exchanger ACT20M-CI-CO-S Use where the field devices are separately powered and the PLC has a passive input. ACT20M training 9 Typical application.... ACT20M-AI-AO-S Control room PLC +24Vdc DC Power Supply DC power for tx In-head 2-wire tx P S +17V 4-20mA 0-20mA Input O/P ACT20M-AI-AO-S Use where the field devices can be powered from the isolator, and the PLC has a passive analog input. Heat exchanger ACT20M training 10 Typical application.... ACT20M-AI-AO-E-S Control room PLC Level tx +24Vdc +24Vdc DC Power Supply P S 4-20mA 0-10V Input O/P ACT20M-AI-AO-E-S Use where mA/Volts conversion is needed, the field devices are separately powered, and the PLC has a passive analog input. ACT20M training 11 Typical application - ACT20M-UI-AO-S Hazardous Area Division 2 or Zone 2 area Controller +24VDC 3-wire Pt100 probe P S Passive input channel 4-20mA output Input O/P ACT20M-UI-AO-S Use where a mixture of inputs / converters are needed (thermocouples, RTDs, Volts, mA) and the receivers have passive inputs Heat exchanger ACT20M training Page 12 Typical application – ACT20M-CI-CO-OLP-S +24Vdc DC Power for field instruments Controller +24Vdc Active input cct – powers the input device 4-20mA proportional to flow P S I/P 4-20mA Input O/P ACT20M-CI-CO-OLP-S Flow Transmitter 2-wire, 4-20mA Use where the field device is separately powered and the isolator is to be powered by it’s receiver. Process vessel ACT20M training Page 13 Typical application – ACT20M-2CI-2CO-OLP-S Class 1 Division 2 or Zone 2 Area Hazardous Area Safe Area +24Vdc DC Power for field instruments Active input ccts – powers input devices 4-20mA signals proportional to flow & temperature Controller P S I/P 1 4-20mA Temperature transmitter 2-wire 4-20mA Input I/P 2 O/P 1 O/P 2 4-20mA ACT20M-2CI-2CO-ILP-S Flow Transmitter 2-wire 4-20mA Use where the field devices are separately powered and the isolator is to be powered by it’s receiver. Process vessel ACT20M-CI-CO-OLP-S ACT20M training Page 14 Typical application – ACT20M-CI-CO-ILP-S +24Vdc DC Power for field instruments Controller 4-20mA proportional to flow P S I/P Process vessel Input O/P ACT20M-CI-CO-ILP-S Flow Transmitter 2-wire 4-20mA ACT20M training Use where a separate isolator power supply is not available, or where the isolator is added to the loop later. Page 15 Typical application – ACT20M-2CI-2CO-ILP-S Class 1 Division 2 or Zone 2 Area Hazardous Area Safe Area +24Vdc DC Power for field instruments 4-20mA signals proportional to flow & temperature Temperature transmitter 2-wire, 4-20mA Controller Passive input ccts P S I/P 1 Input I/P 2 O/P 1 O/P 2 ACT20M-2CI-2CO-ILP-S Flow Transmitter 2-wire, 4-20mA Use where a separate isolator power supply is not available, or where the isolator is added to the loop later. Receivers should have passive inputs. Process vessel ACT20M-CI-CO-ILP-S ACT20M training Page 16 Seite 17 ACT20M training