* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download IC 15030870 rishabh_C12
Oscilloscope history wikipedia , lookup
Audio power wikipedia , lookup
Flip-flop (electronics) wikipedia , lookup
Phase-locked loop wikipedia , lookup
Josephson voltage standard wikipedia , lookup
Analog-to-digital converter wikipedia , lookup
Radio transmitter design wikipedia , lookup
Power MOSFET wikipedia , lookup
Transistor–transistor logic wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Integrating ADC wikipedia , lookup
Wilson current mirror wikipedia , lookup
Valve audio amplifier technical specification wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Surge protector wikipedia , lookup
Valve RF amplifier wikipedia , lookup
Operational amplifier wikipedia , lookup
Voltage regulator wikipedia , lookup
Schmitt trigger wikipedia , lookup
Power electronics wikipedia , lookup
Current mirror wikipedia , lookup
Opto-isolator wikipedia , lookup
Operating Instructions Transducer for Phase angle difference Rish Ducer C12 9 10 11 12 13 14 15 16 RISHABH INSTRUMENTS PVT. LTD. F-31, M.I.D.C., SATPUR, NASIK-422 007, INDIA. RISH Ducer C12 4 0.5 PHASE ANGLE DIFFERENCE TRANSDUCER C11-31B1 D14E 90 SR.NO:07/01/12598 15- 16+ AUX: 230V, 50/60Hz,4 VA 3 UL1 INPUT 415 V 50 Hz 1A 11 N 2 N 4 DIN 43807 UL1 2 DIN 43807 1 CP = 1 9- 10+ OUTPUT :P: 4...20mA R max 750 W I -60...600 el I 1 2 3 4 5 IC15030870 RISHABH INSTRUMENTS Measure, Control & Record with a Difference 6 7 8 RISHABH INSTRUMENTS PVT. LTD. F-31, M.I.D.C., Satpur, Nashik 422 007, India. Tel. : +91 253 2202160, 2202202, Fax : +91 253 2351064 Email : [email protected] www.rishabh.co.in IC 150870 rishabh_c12 26 Aug 09 Safety precautions to be strictly observed are marked with following symbols in the operating instructions : 6.5 19 9.Dimensional drawings 04.5 Operating Instructions Transducer for Phase Angle Difference RishDucer C12 9 10 11 12 13 14 15 16 9 10 11 12 13 14 15 16 Measuring Range D : ±1200 el Nominal Frequency : 50 or 60 Hz Nominal Input Voltage : For both inputs 100/ 3, 110/ 3, 100, 110, 200, 230, 400 or 500 V 1 2 3 4 5 6 7 8 70 1 2 3 4 5 6 7 154 140 125 Measuring Input 130 125 4. Technical Data (Refer Fig.5) 8 126 12 70 125 Measuring Output DC Voltage : 0....10 / 1....5 / -10....0....10 V. Load capacity 20 mA External resistance Rext (KW ) > UAN [V] 20mA UAN = full output value Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Read first and then .....................................2 Scope of supply ..........................................2 Brief description..........................................2 Technical data.............................................2 Mounting.....................................................3 Electrical connections.................................3 Commissioning and maintenance ..............4 Releasing the transducer............................4 Dimensional drawing ..................................5 Special Features.........................................5 DC Current : 0....1mA to 0....20mA / 4.....20 mA -1...0...1 mA to -20...0...20 mA Burden Voltage ±15 V External Resistance Rext max. [KW ] = 15V IAN [mA] IAN = Full output value 1. Read first and then The proper and safe operation of the device assumes that the operating instructions are read and the safety warning given in the various sections 5. Mounting 6. Electrical Connections are observed. DC Voltage The device should only be handled by appropriately trained personnel who are familiar with it and authorised to work in electrical installations. : 24, 115, 120, 230 V or 240 V ± 20% 42 to70 Hz Power consumption approx. 4VA : 24....90 V or 90....240 V -15 /+33% Power Consumption approx. 4W Accuracy Reference value Basic accuracy 2. Scope of supply (Fig. 1) : Output span : Class 0.5 9 10 11 12 13 14 15 16 RISHABH INSTRSUMENT PVT.DLT . Electrical Safety F-31, M.I.D.C., SATPUR, NASIK-422 007, INDIA. RISH Ducer C12 4 15- Installation Category : CAT III, Max. voltage to ground 500 V Pollution degree : 2 Test Voltage : 4 KV between electrically isolated circuits and versus housing 16+ AUX: 230V, 50/60Hz,4 VA 11 N INPUT DIN 43807 UL1 415 V 50 Hz 1A DIN 43807 UL1 2 3 N 2 4 CP = 1 9- 10+ OUTPUT :P: 4...20mA R max 750 W I -60...600 el I 1 2 3 4 5 Measuring range D 0 0 1 between ±60 el. and ± 175 el., 0 but for angle < ±120 el., additional error 0.5% Nominal Frequency fN 2 between 16 and 400 Hz apart from the standard ranges 50 or 60 Hz Limitation at fN > 100 Hz : addtional error 0.2% Limitations at 16 £ fN < 50 Hz : 0 posssible only with measuring ranges >± 60 el. additional error 0.3 % response time t90 < 2 s Power supply derived from measuring input not possible 6 7 8 Fig.1 3. Brief Description : Environmental conditions The RishDucer C12 measuring transducer is used to measure phase angle difference between two synchronised single phase balanced network having sine wave form. The output signal is proportional load independent DC voltage or current. The transducer is available in AC or DC auxiliary supply and also in self power version. Climatic range Operating Temperature Storage Temperature Relative humidity of annual mean 2 : Climate class 3Z acc. to VDI/VDE 3540 : -250C to +550C : -40 to +700C : £ 75% 7 9 Bipolar-symmetrical load-independent DC current Ranges between -1...0...1 and -20...0...20 mA, other than the standard ranges -1...0...1/-2.5...0...2.5/ -5...0...5/-10...0...10 & -20...0...20mA £ 0.5% p.p. instead of £ 2% p.p. Limitations : possible only with nominal frequency ³ 50 response time < 1 s (not suitable for synchronising operations) Power supply without separate power supply connection 11 Power supply from voltage input signal (³ 24 V to 500, fN 50 or 60 Hz) Limitations : Reference condition : Input voltage UN ± 15% with UN ³ 170 V Impulse withstand voltage acc. to IEC 255-4, CI. II : 1 kV,1.2/50 µs, 0.5 Ws or overload capacity of the voltage input max. 680 V~, 2 s The additional power taken from the input voltage signal is approx. 4 VA Output signal A (measuring output A) Unipolar load-independent DC voltage* 4 Ranges between 0...1 and 0....15 V, other than the standard range 0.....10 V 6 Live-zero Ranges between 1..5 and 4...20 mA, other than the standard range 4...20 mA 10 Nominal Input voltage UN 3 between 10 and 600 V, other than the standard values 100/ 3, 110/ 3, 100, 110, 200, 230, 400 or 500 V Limitation : with UN > 500 V overload capacity 2000 V, 2s 5 8 Residual ripple in output current 0.5 PHASE ANGLE DIFFERENCE TRANSDUCER C11-31B1 D14E 90 SR.NO:07/01/12598 1 10. Special Features Power Supply AC Voltage Fig.8 Fig.7 RISH Ducer C12 in housi ng E16 with the screw hole brackets pulled out for wall mount ing. Fig.7 RISH Ducer C12 in housing E16 clipped onto a top hat rail (35 x 15 mm or 35 x 7.5 mm, acc. to EN 50 022). Live-zero* Ranges between 0.2...1 and 3...15 V, other than the standard range 1...5 V *Limitation with UAN < 4 V Additional error : Dependence on external resistance D Rext max. = 0.2%, reference conditions: External resistance 2 x Rext min. ± 20% 12 Bipolar-symmetrical load-independent DC Voltage* Ranges between -1..0...1 and -15...0...15 V, other than the standard range -10...0...10 V with AC Voltage any voltage between 24 and 500 V, ± 20 %, 42 to 70 Hz. Power consumption approx. 4 VA apart from the standard voltages 24, 115, 120, 230 and 240 V Climatic Climate class 3Z acc. to VDI/VDE 3540, but 13 0 temperature continuously -25 to +55 C. Relative humidity £ 90% annual mean (application class HVR acc. to DIN 40 040) Unipolar load-independent DC Current Ranges between 0...1 and 0...20 mA, other than the standard ranges 0...1/0...5/0...10 & 0...20 mA 5 IC 150870 rishabh_c12 26 Aug 09 5. Mounting RISHABH INSTRUMENTS PVT. LTD. F-31, M.I.D.C., SATPUR, NASIK-422 007, INDIA. Manufacturer RISH Ducer C12 4 0.5 PHASE ANGLE DIFFERENCE TRANSDUCER C12-32A1 Z09E A0 SR. NO.: 07/01/12598 15- Type Works No. 16+ Note "Environmental conditions" in section "4.Technical Data" while deciding the place of installation! Power Supply AUX: 230V, 50/60HZ, 4 W 3 UL1 2 INPUT 415 V, 50 Hz 11 INPUT 415 V, 50 Hz N 2 N 4 Measuring range Measured quantity IL1 6 Nominal Frequency 5.1 Top-hat rail mounting Output signal External resistance Simply clip the device onto the Top-hat rail (EN 50 022) (See Fig. 2) Input DIN 43807 UL1 DIN 43807 1 3 10+ 9OUTPUT: 4...20mA I I Fixing the housing to a wall or mounting plate using two 4 mm diameter screws. Drill holes as shown in the drilling pattern (Fig.4) The RISHDucer C 12 can be mounted either on a top-hat rail or directly onto a wall or mounting plate. Output R max 750 W Fig.4. Drilling Pattern 6. Electrical connections Make connection as per printed label on transducer (Fig.5,example of a nameplate) 0 -60...60 el. Fig.5. Declaration of type label Electrical Connections Meaning of symbols on device Front Warning of danger (Caution, see documentation) Double insulation Class II device 4 Impending danger by high input voltage or high mains voltage. Be aware of danger of open Current transformer secondary. Make sure that the measuring input cables are not live(potential-free) when making the connections ! Fig.2 Mounting onto top-hat rail 35 x 15 or 35 x 7.5 mm. (_) (+ ) _ + Test voltage 4 KV 9 10 11 12 13 14 15 16 Note : It is strongly recommended to employ a circuit breaker in building installation to make provision for disconnection of the power supply to device and to provide protection in case of short circuit. The circuit breaker should be close to device, easily reachable and appropriately identified. 5.2 Wall mounting The screw hole brackets (1) can be released and pulled out by pressing on the latch (4). They can be pushed in after pressing the latch (5). 7. Commissioning and maintenance Switch on the power supply and the measuring input. During the operating, you can disconnect the output and connect a test epuipment e.g. For a functional test. No maintenance is required. Note that,..... ... the data required to carry out the prescribed measurement must correspond to those marked on the nameplate of the RISHDucer C12 ( measuring input, measuring output and power supply. See Fig.5) 1 2 3 4 5 6 7 8 8. Releasing the transducer Release the transducer from a top-hat rail as shown in Fig. 6 UG (U1) 1 2 3 4 5 6 7 8 ... the total loop resistance connected to the output (receiver plus leads) does not exceed the maximum permissible value Rext! See "Measuring output" in section "4.Technical data" for maximum values of Rext! US (U2) ... the measurement output cables should be twisted pairs and run as far as possible away from heavy current cables ! U G = Measuring input, generator voltage Fig.3. Rear at device U S = Measuring input, bus voltage = Measuring output Fig. 6 = Power supply 4 (1) Screw hole brackets (2) Latch for pulling the screw hole brackets out In all other respects, observe all local regulations when selecting the type of electrical cable and installing them! (3) Latch for pushing the screw hole bracket in (4) Rubber buffer 3 IC 150870 rishabh_c12 26 Aug 09