Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Technical Data Vacuum Contactor and Starter Specifications Bulletin Numbers 1102C, 1104C, 1109 Topic Page Specifications 2 1102C Approximate Dimensions 3…4 1104C Approximate Dimensions 5 1109 Approximate Dimensions 6…11 Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Description Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Provides general guidelines for installing a Rockwell Automation industrial system. Product Certifications website, http://www.ab.com Provides declarations of conformity, certificates, and other certification details. You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative. 1102C, 1104C, 1109 Vacuum Contactors and Starters Standards Specifications 200 A 400 A 600 A UL 508 CSA 22.2 1500V UL 508 CSA 22.2 1500V UL 508 CSA 22.2 1500V Power Ratings Insul. & Operating Voltage 200…1500V 200…1500V 200…1500V Rated Fequency 50…400 Hz 50…400 Hz 50…400 Hz Making Current Capacity 1600 A 3200 A 4800 A Breaking Current Capacity 1600 A 3200 A 4800 A 6Kv - 1 Min. Interrupter GAP 6Kv - 1 Min. Interrupter GAP 6Kv - 1 Min. Interrupter GAP 2.2 kA 4.6 kA 6 kA Dielectric Strength Interrupting Current (Max.) Short Circuit Withstand (Max.) Mechanical Life Elect. Life AC3 Duty Switching Frequency (Mechanical) 1102C, 1109 1104C Withstand current for 3 sec [kA] 10 kA symmetrical amps @ 1500V AC 18 kA symmetrical amps @ 1500V AC 30 kA symmetrical amps @ 1500V AC 1 200 000 1 000 000 500 000 500 000 750 000 250 000 600/hr (max.) 6 s (full cycle) 600/hr (max.) 6 s (full cycle) 600/hr (max.) 6 s (full cycle) 3.2 6.0 6.5 0.9 A 0.9 A 0.9 A -15% +10% -15% +10% -15% +10% Inrush Power VA 1200VA 1100VA 1600VA Sealed Power VA 12VA 12VA 14VA Opening Time [ms] 120 160 160 Closing Time [ms] 20…40 20…40 30…40 Pick-Up Voltage 80% Cold 85% Hot 80% Cold 85% Hot 80% Cold 85% Hot Drop-Out Voltage 70% or less 70% or less 70% or less Chop Current Max. Control Ratings Coil Voltage Operation Application Ratings Mounting Installation All planes All planes All planes 6600 ft (2000 m) 6600 ft (2000 m) 6600 ft (2000 m) Ambient Storage -65…+160 °F (-54…71 °C) -65…+160 °F (-54…71 °C) -65…+160 °F (-54…71 °C) Operating Temperature -40…+135 °F (-40…57 °C) -40…+135 °F (-40…57 °C) -40…+135 °F (-40…57 °C) 40 Hz: 2 G/30 G 40 Hz: 2 G/30 G 40 Hz: 2 G/30 G Altitude Vibration/Shock 2 Rockwell Automation Publication 1100-TD004A-EN-P Approximate Dimensions 1102C Vacuum Contactor Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 1102C (200 A) 6.44 (163.5) 5.3 (134.5) 0.9 (22.7) 0.68 (17.1) 3.5 (89) (4) Mounting for 1/4 Screws 0.34 5.93 (150.6) 0.32 (8.5) (8.1) 7.5 (190.6) 8.32 (211.3) 8.66 (219.9) Optional Aux. Contact Kit 1.0 (25.1) 3.3 (84.3) Rockwell Automation Publication 1100-TD004A-EN-P 3 1102C Vacuum Contactor Approximate Dimensions Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 1102C (400 A and 600 A) 0.38 (9.7) 0.6 (15.2) 8.0 (203.2) 6.83 (173.5) 6.46 (164.1) R 0.19 (4.8) (4) Mtg. Holes 4.77 (121.2) 0.38 (9.7) 8.2 (208.3) 8.25 (209.5) 9.15 (232.4) 9.25 (234.9) Ø 0.4 (10.2) 0.6 (15.2) 2.54 (64.5) 0.88 (22.4) 9.1 (231.1) 400 A 0.38 (9.7) 0.6 (15.2) 8.0 (203.2) 6.83 (173.5) R 0.19 (4.8) (4) Mtg. Holes 0.81 (20.5) 6.46 (164.1) 2.87 (72.9) 11.88 (301.8) 10.25 (260.4) 8.25 (209.5) Ø 0.4 (10.2) 0.6 (15.2) 2.54 (64.5) 0.88 (22.4) 9.1 (231.1) 600 A 4 Rockwell Automation Publication 1100-TD004A-EN-P 9.15 (232.4) Approximate Dimensions 1104C Reversing Vacuum Contactor Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 1104C (200, 400, 600 A) B C E A D A Height B Width C Depth D Mounting Height E Mounting Width 200 8.375 (213) 14 (358) 6.5 (202) 7 (210) 13 (322) 400 9.25 (235) 21 (533) 7.10 (232) 7.85 (272) 19.5 (495) 600 12 (305) 21 (533) 7.10 (232) 10.82 (280) 19.5 (495) Contactor Size [A] Rockwell Automation Publication 1100-TD004A-EN-P 5 1109 Vacuum Starter Approximate Dimensions Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 1109 (200 A) With E1 Plus Overload 2.59 (65.8) RESET C L 5.79 (147.1) 0.50 (12.7) 0.37 (9.5) 3 places 4.98 (126.6) 9.81 (249.1) 11.96 (303.7) RESET C 15.83 (402) L 14.88 (377.8) 1.52 (38.6) 3.28 (83.4) 4.75 (120.7) 8.44 (214.4) 4.92 (125.1) 6.8 (172.1) 6 Rockwell Automation Publication 1100-TD004A-EN-P Approximate Dimensions 1109 Vacuum Starter Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 1109 (200 A), Continued With Eutectic Overload 5.79 (147.1) 1.78 (45.1) RESET C L 4.98 (126.6) 0.50 (12.7) 0.37 (9.5) 3 places 15.83 (402) 9.81 (249.1) CL 12.62 (320.6) RESET C 14.88 (377.8) L 1.52 (38.6) 4.75 (120.7) 3.28 (83.4) 4.92 (125.1) 8.44 (214.4) Rockwell Automation Publication 1100-TD004A-EN-P 6.44 (163.4) 7 1109 Vacuum Starter Approximate Dimensions Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 1109 (400 A) With E1 Plus Overload 8 Rockwell Automation Publication 1100-TD004A-EN-P Approximate Dimensions 1109 Vacuum Starter Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 1109 (400 A), Continued With Eutectic Overload Rockwell Automation Publication 1100-TD004A-EN-P 9 1109 Vacuum Starter Approximate Dimensions Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 1109 (600 A) With E1 Plus Overload 10 Rockwell Automation Publication 1100-TD004A-EN-P Approximate Dimensions 1109 Vacuum Starter Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin 1109 (600 A), Continued With Eutectic Overload Rockwell Automation Publication 1100-TD004A-EN-P 11 Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/. Allen-Bradley, Rockwell Software, Rockwell Automation, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 Publication 1100-TD004A-EN-P - August 2014 Copyright © 2014 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.