Technical Data
Vacuum Contactor and Starter Specifications
Bulletin Numbers 1102C, 1104C, 1109
Topic
Page
Specifications
2
1102C Approximate Dimensions
3…4
1104C Approximate Dimensions
5
1109 Approximate Dimensions
6…11
Additional Resources
These documents contain additional information concerning related products from Rockwell Automation.
Resource
Description
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1
Provides general guidelines for installing a Rockwell Automation industrial system.
Product Certifications website, http://www.ab.com
Provides declarations of conformity, certificates, and other certification details.
You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of
technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.
1102C, 1104C, 1109 Vacuum Contactors and Starters
Standards
Specifications
200 A
400 A
600 A
UL 508 CSA 22.2 1500V
UL 508 CSA 22.2 1500V
UL 508 CSA 22.2 1500V
Power Ratings
Insul. & Operating Voltage
200…1500V
200…1500V
200…1500V
Rated Fequency
50…400 Hz
50…400 Hz
50…400 Hz
Making Current Capacity
1600 A
3200 A
4800 A
Breaking Current Capacity
1600 A
3200 A
4800 A
6Kv - 1 Min. Interrupter GAP
6Kv - 1 Min. Interrupter GAP
6Kv - 1 Min. Interrupter GAP
2.2 kA
4.6 kA
6 kA
Dielectric Strength
Interrupting Current (Max.)
Short Circuit Withstand (Max.)
Mechanical Life
Elect. Life AC3 Duty
Switching Frequency
(Mechanical)
1102C, 1109
1104C
Withstand current for 3 sec [kA]
10 kA symmetrical amps @ 1500V AC 18 kA symmetrical amps @ 1500V AC 30 kA symmetrical amps @ 1500V AC
1 200 000
1 000 000
500 000
500 000
750 000
250 000
600/hr (max.)
6 s (full cycle)
600/hr (max.)
6 s (full cycle)
600/hr (max.)
6 s (full cycle)
3.2
6.0
6.5
0.9 A
0.9 A
0.9 A
-15% +10%
-15% +10%
-15% +10%
Inrush Power VA
1200VA
1100VA
1600VA
Sealed Power VA
12VA
12VA
14VA
Opening Time [ms]
120
160
160
Closing Time [ms]
20…40
20…40
30…40
Pick-Up Voltage
80% Cold 85% Hot
80% Cold 85% Hot
80% Cold 85% Hot
Drop-Out Voltage
70% or less
70% or less
70% or less
Chop Current Max.
Control Ratings
Coil Voltage Operation
Application Ratings
Mounting Installation
All planes
All planes
All planes
6600 ft (2000 m)
6600 ft (2000 m)
6600 ft (2000 m)
Ambient Storage
-65…+160 °F (-54…71 °C)
-65…+160 °F (-54…71 °C)
-65…+160 °F (-54…71 °C)
Operating Temperature
-40…+135 °F (-40…57 °C)
-40…+135 °F (-40…57 °C)
-40…+135 °F (-40…57 °C)
40 Hz: 2 G/30 G
40 Hz: 2 G/30 G
40 Hz: 2 G/30 G
Altitude
Vibration/Shock
2
Rockwell Automation Publication 1100-TD004A-EN-P
Approximate Dimensions
1102C Vacuum Contactor
Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Bulletin 1102C (200 A)
6.44
(163.5)
5.3
(134.5)
0.9
(22.7)
0.68
(17.1)
3.5 (89)
(4) Mounting for 1/4 Screws
0.34
5.93
(150.6)
0.32 (8.5)
(8.1)
7.5
(190.6)
8.32
(211.3)
8.66
(219.9)
Optional Aux.
Contact Kit
1.0
(25.1)
3.3
(84.3)
Rockwell Automation Publication 1100-TD004A-EN-P
3
1102C Vacuum Contactor
Approximate Dimensions
Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Bulletin 1102C (400 A and 600 A)
0.38 (9.7)
0.6
(15.2)
8.0
(203.2)
6.83
(173.5)
6.46
(164.1)
R 0.19 (4.8)
(4) Mtg. Holes
4.77
(121.2)
0.38 (9.7)
8.2
(208.3)
8.25
(209.5)
9.15
(232.4)
9.25
(234.9)
Ø 0.4
(10.2)
0.6
(15.2)
2.54
(64.5)
0.88 (22.4)
9.1
(231.1)
400 A
0.38 (9.7)
0.6
(15.2)
8.0
(203.2)
6.83
(173.5)
R 0.19 (4.8)
(4) Mtg. Holes
0.81 (20.5)
6.46
(164.1)
2.87
(72.9)
11.88
(301.8)
10.25
(260.4)
8.25
(209.5)
Ø 0.4
(10.2)
0.6
(15.2)
2.54
(64.5)
0.88 (22.4)
9.1
(231.1)
600 A
4
Rockwell Automation Publication 1100-TD004A-EN-P
9.15
(232.4)
Approximate Dimensions
1104C Reversing Vacuum Contactor
Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Bulletin 1104C (200, 400, 600 A)
B
C
E
A D
A
Height
B
Width
C
Depth
D
Mounting Height
E
Mounting Width
200
8.375
(213)
14
(358)
6.5
(202)
7
(210)
13
(322)
400
9.25
(235)
21
(533)
7.10
(232)
7.85
(272)
19.5
(495)
600
12
(305)
21
(533)
7.10
(232)
10.82
(280)
19.5
(495)
Contactor Size [A]
Rockwell Automation Publication 1100-TD004A-EN-P
5
1109 Vacuum Starter
Approximate Dimensions
Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Bulletin 1109 (200 A)
With E1 Plus Overload
2.59
(65.8)
RESET C
L
5.79 (147.1)
0.50
(12.7)
0.37
(9.5)
3 places
4.98 (126.6)
9.81
(249.1)
11.96
(303.7)
RESET C
15.83
(402)
L
14.88
(377.8)
1.52 (38.6)
3.28 (83.4)
4.75 (120.7)
8.44 (214.4)
4.92 (125.1)
6.8 (172.1)
6
Rockwell Automation Publication 1100-TD004A-EN-P
Approximate Dimensions
1109 Vacuum Starter
Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Bulletin 1109 (200 A), Continued
With Eutectic Overload
5.79 (147.1)
1.78
(45.1)
RESET C
L
4.98 (126.6)
0.50
(12.7)
0.37
(9.5)
3 places
15.83
(402)
9.81
(249.1)
CL
12.62
(320.6)
RESET C
14.88
(377.8)
L
1.52 (38.6)
4.75 (120.7)
3.28 (83.4)
4.92 (125.1)
8.44 (214.4)
Rockwell Automation Publication 1100-TD004A-EN-P
6.44 (163.4)
7
1109 Vacuum Starter
Approximate Dimensions
Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Bulletin 1109 (400 A)
With E1 Plus Overload
8
Rockwell Automation Publication 1100-TD004A-EN-P
Approximate Dimensions
1109 Vacuum Starter
Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Bulletin 1109 (400 A), Continued
With Eutectic Overload
Rockwell Automation Publication 1100-TD004A-EN-P
9
1109 Vacuum Starter
Approximate Dimensions
Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Bulletin 1109 (600 A)
With E1 Plus Overload
10
Rockwell Automation Publication 1100-TD004A-EN-P
Approximate Dimensions
1109 Vacuum Starter
Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Bulletin 1109 (600 A), Continued
With Eutectic Overload
Rockwell Automation Publication 1100-TD004A-EN-P
11
Important User Information
Read this document and the documents listed in the additional resources section about installation, configuration, and
operation of this equipment before you install, configure, operate, or maintain this product. Users are required to
familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws,
and standards.
Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required
to be carried out by suitably trained personnel in accordance with applicable code of practice.
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be
impaired.
In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the
use or application of this equipment.
The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and
requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or
liability for actual use based on the examples and diagrams.
No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or
software described in this manual.
Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation,
Inc., is prohibited.
Documentation Feedback
Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this
document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/.
Allen-Bradley, Rockwell Software, Rockwell Automation, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400
Publication 1100-TD004A-EN-P - August 2014
Copyright © 2014 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Related documents