Installation Instructions for Catalog Series 439D Fire Alarm Bell Description and Operation The Edwards 439D series models are heavy-duty, dc powered, vibrating fire bells. They are designed for public mode signaling in accordance with the latest edition of NFPA 72. These vibrating bells produce a long, continuous ringing sound. See table below for electrical specifications. Catalog Number 439D-6AW-R 439DG-6AW Size (in.) 6 439D-8AW-R 8 439D-10AW-R 439DG-10AW 10 Voltage 20/24V DC Amps 0.085 6. Align the tabs on the back of the gong with the grooves in the bell body and secure with the screw and lockwasher removed in step 1. Surface Mounting (Figure 4) 1. Remove screw and lockwasher from front of gong and remove gong. Retain hardware and gong. 2. Cut bell wire leads as needed and strip wire leads back 1/4". 3. Ensure that the mounting plate is aligned with the word "TOP" at the top and facing out and secure metal mounting plate to surface using screws appropriate for the mounting surface (not supplied). Place insulator over studs on mounting plate (Figure 2). CAUTION Break wire run to provide electrical supervision. Do NOT loop bell lead wires around signal circuit wiring. Installation CAUTION Do not apply power to bell until installation has been completed. Prior to starting installation, refer to Figure 1 for bell size. The metal mounting plate supplied with these bells mounts directly on the surface of any single or double gang 3" octagon box, 4" octagon box or 4" square wall box or their plaster cover (boxes and covers supplied by others). For outdoor mounting, use Cat. No. 449 weatherproof box (ordered separately) as shown in Figure 1. Wall Box Mounting (Figure 3) 1. Remove screw and lockwasher from front of gong and remove gong. Retain hardware and gong. 2. Pull bell lead wires through hole in insulator (Figure 2). 3. Feed the power source wiring from electrical outlet box through the metal mounting plate. Ensure that the mounting plate is aligned with the word "TOP" at the top and facing out and secure metal mounting plate to electrical outlet box with appropriate hardware (not supplied). CAUTION 4. See Figure 4. Using wire nuts (not supplied), connect wires to circuit. Push connected wires into bell through entrance hole in bell body base, while mounting insulator and bell body onto studs of metal mounting plate. Secure the bell body onto the metal mounting plate using two lockwashers and two nuts (supplied). 5. Align the tabs on the back of the gong with the grooves in the bell body and secure with the screw and lockwasher removed in step 1. Applying Power WARNING This device will not operate without electrical power. As fires frequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. 1. Apply power to fire alarm or system control panel. 2. Initiate an alarm to activate bell and verify that it sounds. 3. Reset panel to silence bell and return panel to supervisory mode. Maintenance Break wire run to provide electrical supervision. Do NOT loop bell lead wires around signal circuit wiring. 4. Using wire nuts (not supplied), connect wires to circuit and push wires and connections down inside the electrical box (Figures 3 and 5). CAUTION Always disconnect all power before servicing or cleaning bell. Examine bell annually for accumulation of dirt and clean when necessary. 5. Mount insulator and bell body onto studs of metal mounting plate (Figures 2 and 3). Secure using two lockwashers and two nuts (supplied). CHESHIRE, CT 203-699-3300 FAX 203-699-3365 (CUST. SERV.) 203-699-3078 (TECH SERV.) P/N P-047550-0590 ISSUE 6 © 2001 10" Gong 8" Gong Outlet 3/4" (19 mm) 7" (177.8 mm) 6" Gong 11/16" (17.5 mm) 5" 3" (127 mm) (76.4 mm) Optional weatherproof box Cat. No. 449 Center line of base Base 4 5/8" (117.5 mm) Assemble bell base to mounting plate with (2) lockwashers and (2) nuts (supplied with bell) 2 29/32" (73.8 mm) Outlet 3/4" (19 mm) 9" Leads (2) black and (2) red. 1/4" stripped. 5 1/16" (128.6 mm) 3 11/32" (84.9 mm) 5 1/2" (139.7 mm) 3 15/32" (88.1 mm) 5 5/8" (142.9 mm) Figure 1. Bell Dimensions Side View Front View Insulator TOP For wall box mounting: Use bell wire exit hole in mounting plate for bringing bell lead wires out for connections in electrical outlet box For surface mounting: Use wire entrance hole in bell body for circuit wiring to bell lead connections. Place connections in bell housing, behind insulator. (2) Studs Figure 2. Metal Mounting Plate and Insulator Attach green ground wire to appropriate earth ground. Electrical box grounding shown for illustration purpose only. Mounting Plate Mounting Plate Insulator Bell Body Gong Insulator Bell Body Gong $GDSWDEHOO $GDSWDEHOO Grooves for aligning gong Grooves for aligning gong Figure 3. Installing the Adaptabel, Wall Mount Wiring for 4-wire bells to existing 3-wire signal circuit Blk Blk Red End of line resistor Wht Blk Blk Wiring for 4-wire bells Red Red From supervised signal circuit or previous appliance Figure 4. Installing the Adaptabel, Surface Mount Red From supervised signal circuit or previous appliance End of line resistor Blk Blk NOTE: Use leads for connections as shown. Wire run MUST be broken to provide supervision of signal circuit. Figure 5. Wiring Diagrams P/N P-047550-0590 ISSUE 6 Page 2 P/N P-047550-0590 OFFSET SPEC INSTALLATION INSTRUCTIONS FOR CATALOG SERIES 439D SERIES FIRE ALARM BELLS (1) 8 1/2" x 11" SHEET PRINTED BOTH SIDES. FOLD TWO TIMES TO DIMENSIONS SHOWN ON DETAIL WITH PART NUMBER ON THE OUTSIDE. MATERIAL: STANDARD WHITE OFFSET STOCK CHARACTERS: TO BE BLACK ON WHITE BACKGROUND NOTE: MECHANICALS HAVE ALREADY BEEN REDUCED TO ACTUAL SIZE. RETURN MECHANICAL TO: TECHNICAL WRITING EDWARDS SIGNALING 90 FIELDSTONE COURT CHESHIRE, CT 06410 ECN: 01-C1498 FILE: FC6983 ISSUE: 6 APPROVED: KRT P/N P-047550-0590 FOLD DETAIL REFERENCE ONLY