Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
usa.siemens.com/modernize Modernization made easy: A step-by-step guide Future-focused technologies for today‘s Digital Enterprise Unrestricted / © Siemens AG 2015. All Rights Reserved. Digital Factory Table of Contents Your future-focused partner 3 Modernizing with Siemens Digital Enterprise 4 Why Siemens? 5 Why not just stay with my current vendor? 6 Automation solutions for today and tomorrow 7-10 Best-in-class individual components 11 Support and consulting services 12-13 Migration steps 14-26 Modernization tools 27-35 Siemens EtherNet/IP solutions 36-41 Rockwell conversion example 42-52 Contact Us 53 Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 2 Your Future-Focused Partner To meet your customers’ expectations, you have to find new and innovative ways to reduce time-to-market enhance flexibility Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 3 increase efficiency How Siemens Helps: We’re your futurefocused automation partner that can help you adapt to — and capitalize on — the furious pace of change in today’s global economy. Modernizing With Siemens Digital Enterprise How Siemens enables the Digital Enterprise We help you leverage the latest automation technologies to build what we call the “Digital Enterprise.” What is the Digital Enterprise? A holistic approach that covers the entire product lifecycle, from product design to production planning, production engineering, production execution and, finally, services. Our Digital Enterprise Software Suite enables customers to complete the steps of the production lifecycle simultaneously rather than sequentially (the traditional method). The result: improved productivity and efficiency. Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 4 Why Siemens? Return on investment TIA Portal—may reduce your engineering time by up to 30% Productivity Integrated “no programming” diagnostic capabilities Transparency Remote monitoring: Connect to existing third-party controllers for data sharing and move information to today’s MRP systems. Leading Technology State-of-the-art portfolio, including SIMATIC S7-1500 controller Safety Safety Integrated: Comprehensive portfolio of control, drive and switching technology Security A comprehensive, integrated approach for the protection of plant, network and system security. Support Global and local sales and support in 190 countries Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 5 Why not just stay with my current vendor? Obsolete Products Siemens makes modernization easy with: You may still need to: • Convert code to their new programming software • Train your engineers and maintenance personnel • conversion tools a step approach Risk downtime during the changeover support Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 6 training state-of-the-art technologies to sustain future growth Automation solutions for today and tomorrow Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 7 Automation solutions for today and tomorrow A future-focused, totally integrated approach Totally Integrated Automation (TIA) TIA offers: • • • • • • An open system architecture that covers the entire production process Maximum interoperability across all automation components Key Benefits Minimized engineering time Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 8 Consistent data management Global standards Uniform hardware Software interfaces Reduced costs More flexibility Automation solutions for today and tomorrow A future-focused, totally integrated approach BENEFIT TIA optimizes the entire manufacturing process, leading to increased ROI Improved engineering efficiency RESULT Lower design costs Integrated diagnostic functions RESULT Minimized downtime Integrated communication tools RESULT Production flexibility Integrated security functions RESULT Enhanced plant and network security Technologies that protect personnel, machinery and the environment RESULT Improved safety Single, streamlined database RESULT Optimized data quality More access to data RESULT Better decision making Global standards RESULT Simplified implementation of automation solutions Interoperability of system-tested components RESULT Improved overall performance Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 9 Automation solutions for today and tomorrow The TIA Portal The key to unlocking the full potential of TIA is our TIA Portal — A single Features that enable reduction of engineering time transparency and diagnostics include: engineering framework that seamlessly integrates: 1. Controllers 2. Distributed I/O 3. HMI panels 4. Drives, motion control and motor management • • • • • • Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 10 TIA Portal = up to 30% reduction in engineering time! Integrated “no programming” diagnostics One common tag database Ability to create custom libraries An overall project management tool Intuitive system functions Time-saving functions (such as online/offline comparisons, pictorial system view with online diagnostics, no-PC-required trace) Automation solutions for today and tomorrow Best-in-class individual components Upgrade individual products with: • • • • • Ease of integration with existing assets Easy-to-configure hardware and software Resolution of maturity/obsolescence issues Features to support flexibility and competitiveness Flexibility to support various network protocols, including PROFINET and EtherNet/IP Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 11 Automation solutions for today and tomorrow Support and consulting services Industry Online Support Site Resource for comprehensive info, FAQs, and application examples for all products, systems and services in the fields of automation and drives Technical and Engineering Support 24/7 support for all inquiries about functionality, handling and fault clearance of Siemens industrial products Global Support Available in 190 countries; Standardized global part numbers and ease of communication in your preferred language Regional Application Engineers Provide local assistance Experienced Global Network of Certified Solution Partners Extensive industry knowledge using Siemens components to implement tailored solutions for specific applications and timetables Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 12 Automation solutions for today and tomorrow Training Services Our training services help you: Assess Define Implement Manage A workforce improvement program that is customized to your exact learning needs. Courses include: • Product • Safety • Certification learning programs Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 13 Course delivery methods: • In-person • Virtual instructor-led • Digital Siemens Standard Support Services reduce your total cost of ownership: • No Charge single, toll-free number with live operators • No Charge standard technical support until product maturity during normal business hours Modernize your operations, start-to-finish Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 14 Modernization made easy: A step-by-step guide Migration Steps 1 2 INSPECT OBTAIN Physically inspect application / machine for fit, networking and function Obtain a copy of the current documentation for hardware and software 3 DEVELOP Develop the hardware solution Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 15 4 MIGRATE Migrate control code 5 6 ADD TEST Add advanced diagnostics Test the application using simulation 7 8 UPDATE INSTALL Update documentation Install on-site 9 10 START Start up on-site TRAIN Train plant personnel Modernization made easy: A step-by-step guide Flow chart: Start-to-finish steps to modernize your operations START Physically review the system to be migrated Determine the panel space and locale space for mounting an additional panel if required Get drawings of the physical application and a copy of the application program Analyze the current I/O and determine if special hardware is being used Cross reference the I/O to appropriate SIMATIC I/O Locate an appropriate Siemens solution for any special hardware being used such as that supplied by AB Encompass partners Choose and configure an appropriate SIMATIC PLC and configure it in TIA Portal If required to connect to a specific network, determine an appropriate gateway or SIMATIC solution Migrate the existing AB programs using the TIA Migration Tool In the event that a SIMATIC library function is not available for a specific AB function, create a SIMATIC library function and add it to the SIMATIC AB library Create SIMATIC functions for any new hardware or gateways that will be used Create the Main calling routine(s) Add PROGRAM_ALARM for diagnostic messages to the S7-1500 display and HMI Configure the HMI(s) in TIA Portal Verify the HMI Connection(s) Configure the HMI Tags Configure the HMI Graphics Configure the HMI Alarms Configure the HMI Trending Configure the PLC/HMI security Test the new configuration using simulation Correct any issues found during simulation Develop preliminary drawings for the application using the new SIMATIC hardware Modify and document the updates to the application hardware and software Develop an operator/ maintenance manual for the plant Modify and release the final drawings for the application Take the new system to site and install it Archive the application code Wire the IO using the fastest method possible Get acceptance sign-off from customer Adapt the network configuration to the plant network infrastructure Deliver all documentation and drawings to the customer Startup and test the new application END *AB refers to Allen-Bradley® owned by Rockwell Automation® Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 16 Migration Steps Physically inspect application / machine for fit, networking and function 1 Fit INSPECT • • START • Physically review the system to be migrated Determine the panel space and locale space for mounting an additional panel if required Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 17 Function Examine existing panel spaces Does new hardware fit into existing spaces? Space for new panel(s)? Networking • • • Distributed I/O? Drive(s) connectivity? Connectivity to MES? Existing control capabilities • Memory sizes • Execution time • I/O type • Specialized components being used? • HMI(s)? Migration Steps Obtain a copy of the current documentation for hardware and software 2 OBTAIN Get drawings of the physical application and a copy of the application program Hardware Software Wiring • Connectivity • Number of spares • Sensors used • • • • Controller hardware • Controller • I/O • HMI Networking details Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 18 Symbols (tag names) Comments Structure Logic Migration Steps Develop the hardware solution 3 DEVELOP Analyze the current I/O and determine if special hardware is being used Cross reference the I/O to appropriate SIMATIC I/O Locate an appropriate Siemens solution for any special hardware being used such as that supplied by AB Encompass partners Special Hardware Needs Cross Reference Control Hardware Upgrade/change • Encompass partner products Gateways Sensors Controller • Memory size • Execution time • Networking support • Certifications Choose and configure an appropriate SIMATIC PLC and configure it in TIA Portal If required to connect to a specific network, determine an appropriate gateway or SIMATIC solution Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 19 I/O • Module types • Quantity • Wiring • Panel fit Drives HMI Migration Steps Migrate control code 4 Create Equivalent Data Files or Structures MIGRATE Migrate the existing AB programs using the TIA Migration Tool In the event that a SIMATIC library function is not available for a specific AB function, create a SIMATIC library function and add it to the SIMATIC AB library Create SIMATIC functions for any new hardware or gateways that will be used Create the Main calling routine(s) Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 20 Retain current structure • Create equivalent data files with tag names / comments Symbolic • Create equivalent symbolic arrays and comments Create New Logic • Required for new hardware / gateways / sensors Convert Logic Retain current structure • Create equivalent instructions and calling structure Symbolic • Create new instructions and calling structure Migration Steps Add advanced diagnostics 5 Application-Specific Messages ADD • Add PROGRAM_ALARM for diagnostic messages to the S7-1500 display and HMI • Configure the HMI(s) in TIA Portal Verify the HMI Connection(s) Configure the HMI Tags Configure the HMI Graphics Configure the HMI Alarms Configure the HMI Trending Configure the PLC/HMI security Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 21 For the integrated Controller display For the HMI display Fast Machine Diagnostics Maintenance without Development Tools Reduced Downtime and Production Loss Migration Steps Test the application using simulation 6 Test without Hardware TEST Test the new configuration using simulation Correct any issues found during simulation Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 22 Test Incrementally Reduce Startup Time Migration Steps Update documentation 7 UPDATE Ensure Proper Documentation for Plant Maintenance Develop preliminary drawings for the application using the new SIMATIC hardware Develop an operator/ maintenance manual for the plant Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 23 Migration Steps Install on-site 8 INSTALL Install New Control Hardware • • • Take the new system to site and install it Wire the IO using the fastest method possible Adapt the network configuration to the plant network infrastructure • • • Controller I/O Network components (Distributed I/O) HMI(s) Sensors Drive(s) Install New Control Hardware • Disconnect/Connect Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 24 Migration Steps Start up on-site 9 START Startup and test the new application Verify I/O Test Machine Operation Make Changes as Necessary Finalize Application Finalize Documentation Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 25 Migration Steps Train plant personnel 10 Hardware Training TRAIN Development Tools Training Modify and document the updates to the application hardware and software Modify and release the final drawings for the application Archive the application code Get acceptance sign-off from customer Deliver all documentation and drawings to the customer Operator Training Maintenance Training END Documentation Overview Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 26 Modernization Tools To access our complete offering, please visit: usa.siemens.com/modernization-tools. Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 27 Modernization tools Rockwell Automation® PLC-5® to SIMATIC S7 Application Conversion Guide Provides guidance for users who have used legacy control systems based on Rockwell Automation Controller-5 or SLC-500. • • • Explains the major differences between the Rockwell Automation control system and the SIMATIC S7 control system Describes and illustrates migration approaches Demonstrates a number of use cases Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 28 Modernization tools WinCC Tag Converter Provides a fast and easy way to convert tags exported from the Rockwell Controller to a format that can be imported into WinCC (TIA Portal). Produces output for: • HMI systems • SIMATIC Panels • WinCC Runtime Advanced • WinCC Professional Provides the ability to synchronize Rockwell tag data with WinCC (TIA-Portal). This allows WinCC panels to easily communicate with Rockwell controllers. Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 29 Modernization tools Open communication between Logix and S7-1200 / S7-1500 Provides a library for Rockwell ControlLogix/GuardLogix and SIMATIC S7-1200 / 1500 that allows communication via a standard protocol (TCP/IP) without using a gateway. S7-1500 CompactLogix Receive Send Libraries contain communication function blocks for the S7-1200 / 1500 to communicate with Rockwell Logix controllers. Receive Send Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 30 ControlLogix Modernization tools EtherNet/IP™ connectivity S7-1500 EtherNet/IP Function Block (GET/PUT) In development S7-1500 No Code Modifications Required • CompactLogix Function Blocks for SIMATIC S7-1200 / S71500 to read/write data in a Rockwell controller via EtherNet protocols with no code changes in the Rockwell controller. Get Put Get Put Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 31 ControlLogix Modernization tools ProSoft gateways In development PROFINET to EtherNet/IP™ Gateway • • Function Blocks • Provides simple connectivity between controllers and periphery using a ProSoft* Gateway (PROFINET to EtherNet/IP). PROFINET Using gateways ProSoft third-party gateway from other vendors EtherNet/IP is possible. Periphery Systems Controllers Drives Siemens ProSoft gateway Driver Function Blocks for SIMATIC S7-1200 / S7-1500 to communicate EtherNet/IP to ProSoft Gateways for connectivity to Rockwell Automation legacy networks (AB RIO and DCSNet) FB in S7-1500 ProSoft third-party gateway ROK legacy fieldbus (RIO) Periphery Systems Drives *ProSoft is owned by ProSoft Technology®: Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 32 Modernization tools FAQs (Frequently Answered Questions) Sample FAQ Q: How do I communicate with a Rockwell PLC from a Siemens HMI? A: The answer demonstrates: • How to communicate with the maximum data throughput between a Rockwell Controller and a Comfort Panel / Advanced Runtime using the included communication networking driver “Allen-Bradley EtherNet/IP.” Rockwell Controller SIMATIC HMI Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 33 Modernization tools Siemens Migration Studio Migration Studio reads Rockwell software from… RSLogix5 (Controller-5) RSLogix500 (SLC 500) Studio 5000 * (Compact-, ControlLogix) Migration Studio converts… data files (tags) code files (logic) program files tasks routines Migration Studio exports to… TIA Portal V13 SP1 Upd 1 (Openness required) Hardware Conversion WinCC Comfort Advanced RSView32 (PanelView32) In development Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 34 Modernization tools ET200 converter Quickly converts third-party order numbers (Rockwell – 1734 Point I/O, 1756 ControlLogix, Beckhoff, etc.) into SIMATIC ET200 order numbers. • Optimizes conversion result automatically with regard to the number of channels and type of connection Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 35 Via Intranet Siemens EtherNet/IP Solutions The EtherNet/IP™ Solutions family offers the flexibility to support both PROFINET and EtherNet/IP, and compatibility within any PLC. Solutions offer best-in-class features, and configuration to your existing network is fast and easy. Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 36 Siemens EtherNet/IP™ Solutions Connecting ET200S I/O through EIP-200S adapter interface EIP-200S adapter interface facilitates the connection of ET200S modules with EtherNet/IP networks. An application example demonstrates the setup, installation and use of the EIP-200S module with CompactLogix. Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 37 Siemens EtherNet/IP™ Solutions SINAMICS Drives Choose correct control module plus CBE20 board • SINAMICS G130 High-Horsepower Modular Drive Components • SINAMICS G150 Enclosed Drives • SINAMCIS S120 High Performance / Servo Drive System • • CBE20 Communication Board (In chassis, bookshelf, blocksize and enclosed cabinets) EtherNet/IP Connectivity SINAMICS S150 Enclosed Regenerative Drive SINAMICS DCM DC Drives Choose correct Ethernet control module • SINAMICS G120 General Performance Vector Drives Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 38 (In compact, modular, distributed and enclosed versions) Siemens EtherNet/IP™ Solutions SIMATIC Ident – RFID and code reading solutions Rockwell does not currently have a complete RFID solution. Logix Platform The RFID181EIP module acts as the interface to an EtherNet/IP network. RF 181EIP SIMATIC RF300 SIMATIC RF200 Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 39 SIMATIC RF600 Siemens EtherNet/IP™ Solutions Networking Infrastructure / cabling Wired / Wireless Communications FastConnect EtherNet/IP requires IGMP snooping, supported in the following products: • X-500 • X-400 • X-300 • XB200 EtherNet/IP is standard TCP/IP; the networking components just transport the information The most superior cabling solution in the market components just transport the information Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 40 Minimize Risk Enterprise License Program (ELP) Allows easier distribution, installation, license management and maintenance of Siemens Engineering Software at key, multi-site accounts with large numbers of users. Customers who have a long, trusting relationship with Siemens qualify for this program and are able to host Siemens Engineering Software without any copy protection on a centrally located server. This offers an economical solution for customers to maintain a large number of engineering software installations across multiple sites. Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 41 One central software and license management location • Lean and efficient processes • Complete transparency of software use ensures compliance • Easy software inventory provides ad hoc reporting Master Software DVD and reusable Master License Key • Time-saving and standardized installation • Immediate reinstallation in case of hardware crash or change • Existing current licenses can be applied to EPL Easy software maintenance • Supports Engineering Software related to Automation and Drive families • Provides more price stability and simplifies budgeting for the customer Rockwell Conversion Example Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 42 Rockwell conversion example Packaging machine Rockwell • Allen Bradley SLC 500 • Panelview • AMCI Resolver Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 43 Siemens • SIMATIC S7-1500 • SIMATIC Basic Panel • SIMOTICS Encoder Rockwell conversion example Controller program structure Similar program structure for maintenance personnel Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 44 Rockwell conversion example Controller program file structure Similar file-naming structure, but more intuitive Siemens can still work with absolute data files • No need to convert to arrays Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 45 Rockwell conversion example Controller program logic structure Ladder logic is ladder logic Similar symbols Comments are the same Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 46 Rockwell conversion example Controller tags Tag names nearly identical Similar addressing Comments are the same Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 47 Rockwell conversion example HMI structure Same screen names Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 48 Rockwell conversion example HMI tags Tag names nearly identical Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 49 Rockwell conversion example HMI screens Similar look and feel Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 50 Rockwell conversion example New diagnostic features Integrated Controller display • Hardware diagnostics • Machine diagnostics • Command functions • System Maintenance • No PC required • Password protected Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 51 Rockwell conversion example Benefits No surprises for maintenance Enhanced Diagnostics • • • • • • • • • Controller program structure Controller logic Controller tags HMI structure HMI tags HMI screens Unrestricted / © Siemens AG 2015. All Rights Reserved. Page 52 Controller Display Self configuring Ethernet devices Web pages ROI until mid-century For a comprehensive set of tools to ease your transition, visit usa.siemens.com/modernizationtools