Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Clarification No.3 Publication Ref: EuropeAid/138127/ID/SUP/TR Subject: Supply of Equipment for Improvement of the Shared Industrial Infrastructure of the Pistachio Processing Sector Location – Siirt, Turkey Further to the requests received from the tenderers, the following clarifications are provided: ANNEX II + III : TECHNICAL SPECIFICATIONS + TECHNICAL OFFER LOT 1 QUESTIONS ANSWERS For Article 1.1.4.4, the maximum operating Q1 1.1 HPLC WITH DEDECTOR 1.1.4.4 Maximum operating pressure: at least 400 pressure of the quaternary pump shall not take into consideration the psi value with bar. eluent generation. The current specification is specific to the one manufacturer (Agilent) although there are also other Please also note that 400 bar is a widely used items which is originated in EU. operating pressure for similar applications, On the other hand, The desired device is not a UPLC therefore the related specification remains system. In traditional HPLC applications are not rise unchanged. to such high pressure. Also, in such high pressure the normal HPLC colons make leak and the requested Please also refer to Question-5 under colon is a normal in technical specification. Even 345 Clarification No.1 bar will be a very high pressure. So, to be more competitive tender we kindly request you to change this specification as below. 1.1.4.4 Maximum operating pressure: at least 5000 psi (345 bar). Q2 1.1 HPLC WITH DEDECTOR 1.1.5 Autosampler Specifications Question: Is it obligation for obtaining Autosampler device at the same brand with HPLC device, since most of the manufacturers supply autosampler with a different brand?, can we offer different brand for autosampler which meets with requirement with HPLC device? Autosampler can be provided from different brand satisfying the minimum technical requirements and compatible with the offered HPLC device. 1/8 Q3 1.1.6.2.: Contains Peltier-controlled heat exchangers for effective cooling and heating. For rnycotoxin and aflatoxin analysis ; Column temperature should be approximately 40 °C . So heating is important for " Column Temperature Control Module " Cooling option is specific feature for some companies. The application of the lab shall not be limited to one specific analysis. The technical specification does not indicate any temperature range for cooling. It requires that the item shall have peltier unit operation, not just heat-only units. Specification remains unchanged. We kindly ask you to let change this specification as "Contains Peltier-controlled heat exchangers for effective heating" Q4 1.6.9.: "Interpupillary distance adjustment range (a-b): a: min 30mm-max 90mm" According to the above specification requested range is given with min and max values. In order to prevent any misuderstanding, could you please inform us we can offer an "adjustment range" for requested microscope between 30mm-90mm? (As an example: 40-80mm, 35-65mm etc..) Q5 The lower limit of the interpupillary distance shall be 30mm or higher, whereas the highest distance shall be 90mm or lower. Any values between these ranges (a-b) is acceptable. With this regard, the provided examples in the question also satisfies the minimum technical requirements. 1.8 ELISA READER WITH TEST KIT Specification remains unchanged. 1.8.2 Filter Capacity and number of filters: min 4 Please also see the Question-15 under Clarification No.1 Wavelength range min. 400-700 nm or wider range The new systems are not required of filter and this is better than requested. So, we kindly request you to change this specification as below. 1.8.2 Filter Capacity and number of filters: min 4 or the device doesn’t need any filter Wavelength range min. 400-700 nm or wider range Q6 1.8 ELISA READER WITH TEST KIT 1.8.11 “PC Operated. Supplied with related connections and software” : Question: Is it required to supply with PC or not? Does Related software includes data analyzing? The software shall be the standard bundled software for the operation of the elisa reader. The technical specification indicates that the item shall be PC operated but a separate PC shall not be supplied. 2/8 Q7 1.8 ELISA READER WITH TEST KIT 1.8.12 Lamp: Halogen Lamp Halogen Lamp is an old technology and this lamp has 2.000 hours life. Xenon flash lamp is a new technology and better than halogen lamp. Xenon flash lamp has endless life. The new system use xenon flash lamp. To be more competitive tender we kindly request you to change this specification as below. Please see the Corrigendum No.4 to the Tender Dossier. 1.8.12 Lamp: Halogen or Xenon Flash Lamp Q8 1.8 ELISA READER WITH TEST KIT 1.8.12 “Lamp: Halogen Lamp”: Please see Answer-7. Question: "Is halogen lamp a must? Our instrument has a LED lamp which is much more advanced than halogen lamp. Is this acceptable?" Q9 A single box composed of 100 tests is 1.8.14 “Supplied with 100 units of Alfatoxin ELISA enough. Test Kits along with pipettes with standard 96 The pipettes can be multichannel compatible wells/kit with ≤0.05ppb sensitivity and high with standard 96 wells application. There is recovery (>80%) and suitable for aflatoxin analysis no specific requirement or obligation with in pistachio and peanuts.” : number of channels for a multichannel 1.8 ELISA READER WITH TEST KIT Question: Is it required in ‘units’ or ‘tests’ since one unit has a high cost, but 100 tests are included in only one box (as kit). pipette system. On the other hand, what is the channel number for pipettes? Q10 1.8 ELISA READER WITH TEST KIT 1.8.13 Rapid Aflatoxin Test Kit (B1-B2-G1-G2) 1.8.14 Supplied with 100 units of Alfatoxin ELISA Test Kits along with pipettes with standard 96 wells/kit with ≤0.05ppb sensitivity and high recovery (>80%) and suitable for aflatoxin analysis in pistachio and peanuts. Question 1: Is Origin obligatory for those Test Kits in this item also? Items 1.8.13 and 1.8.14 are required for initial operational requirements of the unit and the ELISA system. Tenderers are required to supply such consumables separately (which can be of different brand) for this item and since these articles are not indicated as separate items, the “Technical Documents to be provided during the implementation period” as mentioned in Article 2 of the General Requirements does not apply for items 1.8.13 and 1.8.14, but only for the ELISA Reader machine itself. Please also see Question-16 under Clarification No.1 3/8 Q11 1.13 AUTOCLAVE Item 1.13.8 “Automatic control for heating, sterilization, water filling.” : This item restricts the potential tenderers to prepare satisfied proposal for this tender. To provide more attendance, to provide best competition and to eliminate cancellation possibility of this tender, we kindly request the contracting authority to change this item in the technical specifications to be read as follows: “Automatic or manuel control for heating, sterilization, water filling.” Q12 1.15 FREEZER 1.15.2 Freezing capacity range: -10 ºC to -25 ºC or wider range The freezing capacity of laboratory freezer generally starting from -20 ºC . Providing a lower temperature is more useful. We kindly request you to change this specification as below Please see the Corrigendum No.4 to the Tender Dossier. The requested “-20 ºC to -45 ºC or wider range” already meets the minimum requirement of “-10 ºC to -25 ºC or wider range”, therefore the specification remains unchanged. 1.15.2 Freezing capacity range: -20 ºC to -45 ºC or wider range Q13 1.15.7. Shelves: PVC laminated or aluminum shelves. Shall have minimum 4 baskets or isolated compartments. Please see the Corrigendum No.4 to the Tender Dossier. In general, for laboratory usage stainless steel material is one of the best and most efficient solution for both interior and exterior of the coolers. For item 1.15 stainless steel interior has been already requested but shelves are requested to be PVC laminated, Then, aluminum material was also added to TS. We strongly recommend the contracting authority to also add "stainless steel shelves" to above mentioned specification in terms of durability and efficiency. It will also help to enable competition. 4/8 Q14 1.16.1.: Container Capacity: min 15 liters Could you please clarify that the mentioned container will be used as a feeder for the grinder or will be used to collect the grinded materials after the grinding process. If it will be used after the grinding process, could you please inform us whether we can offer the container seperately? The technical specification does not indicate the container type, since solutions may be different according to the manufacturers. For some systems the feeding container can be a separate unit, whereas some items use integrated containers. It is requested that the grinder shall be capable of operating with min 15 liter capacity (pistachio and similar material qualification) either with a separate container and motor unit, or an integrated container and motor. With this regard a separate container can also be offered. Q15 1.16 GRINDER 1.16.1 “Container Capacity: min 15 liters” : 1.16.4 “Blade Speed: min 6500 rpm” : It is declared from many manufacturers that container capacity and blade speed are inversely proportional since one decreases by the other increases. It is said that the grinder having min 6500 rpm can not be with a min 15 liter container capacity. So, is it min 1,5 liters and min 6500 rpm actually? The required minimum blade speed does not indicate a criterion to be achieved with a fully loaded container capacity. The blade speed refers to the performance of the standard motor/blade speed. Specification remains unchanged. On the other hand, to provide more attendance, we kindly request the contracting authority to change the item below also to be read as follows : "Blade Speed: Motor Power: 0,6 – 0,9 kW 750 / 1500 rpm" Q16 1.17 LAB BLENDER: In the market, there is only one or two brands producing laboratory type blenders. Unfortunately, these blenders are not manufactured in an eligible country. Therefore, we kindly request contracting authority to give derogation for this item or remove this item from item list. Please see the Corrigendum No.4 to the Tender Dossier. 5/8 Q17 1.17 LAB BLENDER Specification remains unchanged. 1.17.4 “Max attainable RPM: min 10000 rpm – variable speed option.”: To provide more attendance, to provide best competition and to eliminate cancellation possibility of this tender, we kindly request the contracting authority to change this item in the technical specifications to be read as follows: "Max attainable RPM: Motor Power: 300-500 W – 9000 rpm" Q18 1,19.14.: "Display features: HEPA and UV life span, temperature, air flow and speed." According to our market research, instead of life span for UV and HEPA, there are counters showing the elapsed time. This might also be more efficient solution for HEPA and UV. Therefore, we kindly request contracting authority to change this specification as; The life span means that the cabinet shall provide the user proper information concerning the need for a replacement of the related filters or monitoring the filter status. This can be achieved with different mechanisms or displays. Specification remains unchanged. "Display features: "HEPA and UV counter; temperature, air flow and speed" or "HEPA and UV life span or counter; temperature, air flow and speed" Q19 Although there are items satisfy not only rule of origin but also technical specifications, it is imposible to submit the Certificate of origin due to the they are cheap and number of items is low. We kindly request you not to request the below items as seperate items. For Items 1.21 Ph-Meter Specification remains unchanged. Q20 1.21.2.: Electrode: shall have temperature and pH electrodes. Some manufacturers in the market are able to combine the measuring of PH and the temperature in a single electrode. This might be more practical than requested. Therefore, we kindly request the contracting authority to modify this specification as; "Electrode: shall have temperature and p1-1 electrodes or PH electrode with temperature sensor." Q21 1.21.6.: "Temperature sensitivity: maximum 0.1 °C" In order to prevent misunderstanding and confusion, could you please clarify the mentioned "sensivity" means/indicates "resolution value"? Technical specification is indicated as “electrode”, therefore a combined solution mentioned in the question is also acceptable. It does not indicate specifically single or multi electrode solutions. Specification remains unchanged. Some manufacturers use different terminology. Sensitivity also means resolution. 6/8 ANNEX II + III : TECHNICAL SPECIFICATIONS + TECHNICAL OFFER LOT 2 QUESTIONS ANSWERS Please see the Corrigendum No.4 to the Q22 2.2 PROJECTOR WITH SCREEN 2.2.7 Standards: Projector shall be compliant with Tender Dossier. EMC Directive 2004/108/EC, Low Voltage Directive 2006/95/EC, ENERGY STAR® No projector does not have Energy Star Standard. Please find devices with this certification in this link https://www.energystar.gov/products. To be competitive tender, we kindly request you to change this specification as below. 2.2.7 Standards: Projector shall be compliant with EMC Directive 2004/108/EC, Low Voltage Directive 2006/95/EC. The device should have energy saving feature. Q23 2.2 PROJECTOR WITH SCREEN 2.2.7 Standards: Standards: Projector shall be compliant with EMC Directive 2004/108/EC, Low Voltage Directive 2006/95/EC, ENERGY STAR® Please see Answer-22. After our wide market research we have reached to the conclusion that there is no projection device having ENERGY STAR® certification. Therefore we kindly request you to remove ENERGY STAR® from this article. ANNEX II + III : TECHNICAL SPECIFICATIONS + TECHNICAL OFFER LOT 3 QUESTIONS ANSWERS Item 3,1 Office Desk: On lline 3,1,10 metal Please see the Corrigendum No.1 to the Q24 Tender Dossier. The related specification was components are requested as cromium plated. already changed. Please also see Question 41 Could you please kindly clarify if electrostatic under Clarification No.1. powder paint after anti-corrosion surface treatment is also acceptible. Q25 Item 3,3 Meeting Table: On lline 3,3,4 metal components are requested as cromium plated. Could you please kindly clarify if electrostatic powder paint after anti-corrosion surface treatment is also acceptible. Please see the Corrigendum No.1 to the Tender Dossier. The related specification was already changed. Please also see Question 42 under Clarification No.1. 7/8 Q26 Item 3,12 Double Visitor Seat: On line 3,12,4 seating width is requested as 55-65 cm. Industry standard is 45-50 cm. Could you please kindly revise seating width dimension. Please see the Corrigendum No.1 to the Tender Dossier. The related specification was already changed. Please also see Question 43 under Clarification No.1. 8/8