* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download summary of requirements
Ground loop (electricity) wikipedia , lookup
Opto-isolator wikipedia , lookup
Voltage optimisation wikipedia , lookup
Electronic musical instrument wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Induction motor wikipedia , lookup
Control system wikipedia , lookup
History of electric power transmission wikipedia , lookup
Three-phase electric power wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Electric power system wikipedia , lookup
Power engineering wikipedia , lookup
Printed circuit board wikipedia , lookup
Resilient control systems wikipedia , lookup
Fault tolerance wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Surface-mount technology wikipedia , lookup
Circuit breaker wikipedia , lookup
Electronic engineering wikipedia , lookup
Surge protector wikipedia , lookup
Mains electricity wikipedia , lookup
Ground (electricity) wikipedia , lookup
Electrical substation wikipedia , lookup
Alternating current wikipedia , lookup
Transmission tower wikipedia , lookup
Residual-current device wikipedia , lookup
Earthing system wikipedia , lookup
Electrical wiring wikipedia , lookup
National Electrical Code wikipedia , lookup
June 7, 2006 SUMMARY OF REQUIREMENTS The following is a brief summary of the new and revised paragraphs in the Standard for Standard For Safety For Industrial Control Panels, UL 508A, which have a future Effective Date of March 1, 2007 and the action that may be required to determine compliance. Paragraphs 16.1, 16.2 16.3 17.4 29.2.1, 29.3.11 29.2.2, 29.6.2 General Subject and Comment Grounding of power supply secondary circuits: The revisions may require power supplies connected to a primary voltage greater than 150V to ground to have their secondary circuit(s) grounded in accordance with 16.1 and 16.2. Compliance with these requirements will be determined by UL inspection visits following the effective date. Slash rated components provided in secondary circuits: The new 16.3 requires the secondary circuit of a transformer or power supply to be grounded consistent with the specific voltage requirements when components, such as overcurrent protection devices, with slash voltage ratings are supplied in the secondary circuit. This requirement applies whether or not the secondary circuit is required to be grounded per 16.1. Compliance with these requirements will be determined by UL inspection visits following the effective date. Color-coding of grounded circuit conductor: The revision causes grounded circuit conductor(s) in the secondary of power supplies to be identified by color in accordance the provisions in 17.4. Compliance with these requirements will be determined by UL inspection visits following the effective date. Terminations for flexible internal conductors: Where flexible conductors, including welding cable, flexible machine tool wires, and DLO cables, are provided, terminals at both ends of the conductor must be suitable for use with the conductor class. Manufacturers using flexible conductors after the effective date must have terminals suitable for the purpose described in their follow-up procedure. Compliance with these requirements will be determined by UL inspection visits following the effective date. Recognized component bus bars: The revisions permit use of previously tested bus bar systems that may have increased ampacity and short circuit current ratings as compared to the ratings allowed for bus bar assemblies that meet the construction requirements in 29.2.2 and 29.6.2. Manufacturers intending to use Recognized component bus bar assemblies must have all parts, assembly requirements and electrical ratings described in their follow-up procedure. Subject No. 508A Page 2 of 4 June 7, 2006 Paragraphs General Subject and Comment 29.6.1, Table 29.1, 35.2.1.2, 36.2.4 Reduced ampacity for internal wiring of power circuits: The revisions require Table 28.1 to be used for internal wiring ampacities; Table 29.1 has been deleted. As a result, 16AWG and 18AWG conductors will no longer be permitted in power circuits, 14AWG will be the minimum conductor size allowed for power circuits. Manufacturers may need to modify existing industrial control panel constructions so that power circuit conductors meet the revised requirements following the effective date. Compliance with these requirements will be determined by UL inspection visits following the effective date. 38.2, 38.2.1, Table 38.1, 41.1, 42.1.2.2, 42.2.3.3, and 42.3.1 Ampacity of internal wiring of control circuits: The revisions require Table 28.1 to be used for internal wiring ampacities 14AWG and larger conductors. The ampacities of conductors, 16AWG and smaller, in Table 38.1 are unchanged. Manufacturers may need to modify existing industrial control panel constructions so that 14AWG and larger control circuit conductors meet the revised requirements following the effective date. Compliance with these requirements will be determined by UL inspection visits following the effective date. 31.4.1 31.4.3 31.4.4 Branch circuit protection for motor groups: The revised 31.4.1 may require modification of the ampere rating of the motor group branch circuit protection, or the ampacity of tap (power circuit) conductors, or both. Only branch circuit type fuses and inverse- time circuit breakers are suitable as the branch circuit protection for motor groups. Compliance with these requirements will be determined by UL inspection visits following the effective date. Protection of tap conductors in motor groups: The new 31.4.3 will require all motor tap conductors, i.e. conductors that carry current from a single motor, to have an ampacity, per Table 28.1, that is coordinated with the overall size (ampere rating) of the motor group. Manufacturers may need to modify existing industrial control panel constructions by one or more of the following means: a) increase the size of the tap conductors, b) reduce the number of loads in the motor group, c) grouping loads having similar ampere ratings, or d) provide additional protective devices. Compliance with these requirements will be determined by UL inspection visits following the effective date. Overcurrent protection for other (non-motor) loads included in motor groups: The new 31.4.4 requires additional branch circuit protective devices to be installed for non-motor loads in accordance with the requirements in 31.5 – 31.8 when the ampere rating of the branch circuit protection for the motor group is too large to provide the required overcurrent protection. Compliance with these requirements will be determined by UL inspection visits following the effective date. Subject No. 508A Paragraphs 65.1 Page 3 of 4 June 7, 2006 General Subject and Comment Revised requirements for industrial control panels marked for use with industrial machinery: 1. Revised reference to 2002 edition of NFPA79. 66.1.1, 66.1.2, 66.1.4 2. Specific enclosure metal thickness and door width requirements have been deleted. Enclosures that meet the requirements in section 18.3 of UL508A are acceptable. 66.1.3 3. Revision eliminates requirement for all enclosures to have a door. Enclosures with covers may be used in accordance with the exception to18.4 of UL508A. Revision adds specific travel requirement for accessibility of components on or behind swing out panels. 66.1.5 4. Revision to 66.1.5 describes the conditions that require the enclosure doors to be interlocked with the disconnecting means and that all doors must be prevented from opening. 66.1.5.1 5. New 66.1.5.1 describes the requirements for operation of the interlock defeat mechanism that were extracted from 66.1.5 and does not change the current requirement. 66.1.6, 66.1.8 6. Requirements for lighting circuits have been combined into 66.1.8. Panels containing internal maintenance lighting circuits or that supply external work light circuits will be required to be protected by means of 15A branch circuit protective device. 66.1.9 7. New requirement for mounting components to facilitate their replacement. This requirement will prohibit components from being mounted to a fixed sub-plate or sub-panel by means of a machine screw and nut. 66.2.1 8. Revision will require physical arrangement of all control circuit components, regardless of voltage, to be grouped or mounted separately from all power circuit components. 66.2.2 9. New 66.2.2 will require grouping, separation or color coding of field wiring terminals of power circuits, control circuits, and externally supplied control circuits (yellow wire). 66.1.7, 66.3.1 10. Requirements for grounding internal maintenance lighting circuits and external work light circuits have been combined into 66.3.1. 66.3.2 11. Revised 66.3.2 requires control transformer secondary circuits that are not grounded to be provided with ground detection means. 66.3.4 12. New 66.3.4 requires a bonding conductor to be factory supplied between the control panel enclosure and a door containing electrical components operating at more than 30Vrms. 66.5.3 13. Revised 66.5.3 allows for additional color options for grounded circuit conductors in power circuits. Subject No. 508A Paragraphs 66.5.4, Table 66.1A Page 4 of 4 June 7, 2006 General Subject and Comment Revisions for control panels for industrial machinery (continued) 14. Revision to 66.5.4 allows for 16AWG and 18AWG conductors to be provided in power circuits when sized and protected in accordance with Table 66.1A. 66.5.7 15. Revision to 66.5.7 requires power circuit conductors, 14AWG and larger, to be sized based on ampacities from Table 28.1. 66.6.1 16. Revised 66.6.1 allows only terminals to be provided on the line side of the disconnecting means. Other components cannot be installed on the line side of the disconnecting means. 66.6.3 17. New 66.6.3 requires the disconnecting means to be readily operable, and lockable in the “off” position independent of the position of the enclosure door. 66.7.1 18. Revised 66.7.1 allows Class T fuses to be optionally used as branch circuit fuse. 66.8.1 19. Revised 66.8.1 extends the application of the mechanical and electrical interlock requirement to contactors of wye-delta controllers. 66.8.3, 67.3.2 20. New 66.8.3 requires the use of Listed robot controllers and marking referring to the designated manipulator arm to be installed in the field. 66.9.1 21. Revised 66.9.1 allows orange as an alternate color-coding to yellow to identify control circuit conductors that remain energized when the main disconnecting means is opened. 66.11.1, 66.11.2, Tables 66.5 and 66.6 22. Deleted Section 6.11 requirements for control transformer protection. Control transformer overcurrent protection shall comply with Section 42.1. 66.12.3 23. Revised 66.12.3 requires emergency stop switches to be self-latching or maintained position switch. 67.1.1 24. Revised 67.1.1 adds the ampere rating of the largest heater load to the panel nameplate electrical ratings. 67.1.2, 67.1.3 67.4.1 25. Revised 67.1.2 and new 67.1.3 provides clarification of the location of the existing marking requirements. 26. Revised 67.4.1 allows alternate cautionary markings to identify a control panel enclosure containing electrical equipment. The revisions and additions described in items 3, 4, 6 – 9, 11, 12, 15 – 17, 19,20, 23, and 24 above may require modifications of existing industrial control panel designs that are marked for use with industrial machinery in order to comply with the requirements on the effective date. Compliance with these requirements will be determined by UL inspection visits following the effective date.