• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ADS1201 数据资料 dataSheet 下载
ADS1201 数据资料 dataSheet 下载

Online Thévenin Equivalent Determination Considering
Online Thévenin Equivalent Determination Considering

... connected to a single equivalent series impedance. It should be made clear that, when applied to a power system, the equivalent source voltage and impedance will change following any change in the network. However, in the short term, a few cycles, variations in a large system are not expected to cau ...
INA118 数据资料 dataSheet 下载
INA118 数据资料 dataSheet 下载

7 Modeling Ferrite Core Losses
7 Modeling Ferrite Core Losses

... calibrated test setup. The testing itself is very involved. We will not cover the specifics of the testing in this article, but we can offer a word of caution. Measuring core loss yourself is not recommended. The instrumentation setup required to receive reliable results is tedious and difficult. An ...
The effects of resistor matching on common
The effects of resistor matching on common

... applications engineer, Analog Devices ...
exp04_add
exp04_add

... Steps in Analyzing Op-Amp Circuits 1) Remove the op-amp from the circuit and draw two circuits (one for the + and one for the – input terminals of the op amp). 2) Write equations for the two circuits. 3) Simplify the equations using the rules for op amp analysis and solve for Vout/Vin Why can the o ...
MAX2754 - Maxim Integrated
MAX2754 - Maxim Integrated

UPS-1500-S-1U
UPS-1500-S-1U

... SynQor’s Military-Grade Uninterruptible Power Supply units are designed for the extreme environmental and demanding electrical conditions of Military/Aerospace applications. SynQor’s UPS incorporates field proven high efficiency designs and rugged packaging technologies. This UPS will accept a wide ...
ISL32704E Datasheet
ISL32704E Datasheet

... 6. All voltages on the isolator primary side are with respect to GND1. All line voltages and common-mode voltages on the isolator secondary or bus side are with respect to GND2. 7. Differential I/O voltage is measured at the noninverting bus terminal A with respect to the inverting terminal B. 8. Sk ...
MPA Gold Manual
MPA Gold Manual

PM50/PM80 Installation manual
PM50/PM80 Installation manual

... 5. Connect your isolation tester between output ”U1” and case. See ‫ד‬. Raise the voltage of the isolation tester from 0 to 500Vd.c. Check that the leakage current does not exceed 5µA. The voltage should not be applied for more than a few seconds or the Y-capacitors might be damaged. 6. Turn off the ...
LT5546
LT5546

... a 10dB signal-to-noise ratio. In the case of an L-C matching circuit, the circuit of Figure 1 can be used. In Table 1 the matching network component values are given for a range of IF frequencies. The matching circuit of Figure 1 approaches 180° phase shift between IF+ and IF– in a broad range aroun ...
差分放大器系列AD8323 数据手册DataSheet 下载
差分放大器系列AD8323 数据手册DataSheet 下载

... Interface Specifications) certified cable modems and CATV settop boxes. Upstream data is modulated in QPSK or QAM format, and done with DSP or a dedicated QPSK/QAM modulator. The amplifier receives its input signal from the QPSK/QAM modulator or from a DAC. In either case the signal must be low-pass ...
TPA2000D1 数据资料 dataSheet 下载
TPA2000D1 数据资料 dataSheet 下载

Lecture 5
Lecture 5

... Operational Amplifers Op-amp is an electronic device that amplify the difference of voltage at its two inputs. ...
7-Port Hub for the Universal Serial Bus w
7-Port Hub for the Universal Serial Bus w

... the TPS2044, are required to control the 5-V power source switching (on/off) to the downstream ports and to detect an overcurrent condition from the downstream ports individually or ganged. An individually port power controlled hub switches power on or off to each downstream port as requested by the ...
Pendulum MDP-1 Operating Manual
Pendulum MDP-1 Operating Manual

RF Amplifier Output Voltage, Current, Power
RF Amplifier Output Voltage, Current, Power

... By: Jason Smith; Manager Applications Engineer and Pat Malloy; Sr. Applications Engineer ...
PPT - School of Engineering and Applied Science
PPT - School of Engineering and Applied Science

UC29431 数据资料 dataSheet 下载
UC29431 数据资料 dataSheet 下载

MAX7328/MAX7329 I C Port Expanders with Eight I/O Ports 2
MAX7328/MAX7329 I C Port Expanders with Eight I/O Ports 2

... 19-3829; Rev 0; 10/05 ...
LT6600-20
LT6600-20

... amples where impedance must be considered is the evaluation of the LT6600-20 with a network analyzer. Figure 5 is a laboratory setup that can be used to characterize the LT6600-20 using single-ended instruments with 50 source impedance and 50Ω input impedance. For a unity gain configuration the LT660 ...
ADC运算放大器系列OP292 数据手册DataSheet 下载
ADC运算放大器系列OP292 数据手册DataSheet 下载

... limitation of the circuit configuration where the first amplifier must be able to swing below ground in order to attain a 0 V common-mode voltage, which it cannot do. Depending on the gain of the instrumentation amplifier, the input common-mode extends to within about 0.3 V of zero. One can easily c ...
Impedance Matching
Impedance Matching

... Impedance is an important parameter to characterize electronic circuits, components, and materials used to make components.  Impedance Z is defined as the total opposition of a device or circuit to the flow of an alternating current (AC) at a given frequency, and is represented as a complex quantit ...
RF5755 2.4GHz TO 2.5GHz 802.11b/g/n WiFi FRONT END MODULE Features
RF5755 2.4GHz TO 2.5GHz 802.11b/g/n WiFi FRONT END MODULE Features

... The RF5755 integrates the matching networks and DC blocking capacitors for all RF ports. This greatly reduces the number of external components and layout area needed to implement this FEM. Typically only a total of four external components are required to achieve nominal performance. However, depen ...
< 1 ... 47 48 49 50 51 52 53 54 55 ... 107 >

Scattering parameters

Scattering parameters or S-parameters (the elements of a scattering matrix or S-matrix) describe the electrical behavior of linear electrical networks when undergoing various steady state stimuli by electrical signals.The parameters are useful for electrical engineering, electronics engineering, and communication systems design, and especially for microwave engineering.The S-parameters are members of a family of similar parameters, other examples being: Y-parameters, Z-parameters, H-parameters, T-parameters or ABCD-parameters. They differ from these, in the sense that S-parameters do not use open or short circuit conditions to characterize a linear electrical network; instead, matched loads are used. These terminations are much easier to use at high signal frequencies than open-circuit and short-circuit terminations. Moreover, the quantities are measured in terms of power.Many electrical properties of networks of components (inductors, capacitors, resistors) may be expressed using S-parameters, such as gain, return loss, voltage standing wave ratio (VSWR), reflection coefficient and amplifier stability. The term 'scattering' is more common to optical engineering than RF engineering, referring to the effect observed when a plane electromagnetic wave is incident on an obstruction or passes across dissimilar dielectric media. In the context of S-parameters, scattering refers to the way in which the traveling currents and voltages in a transmission line are affected when they meet a discontinuity caused by the insertion of a network into the transmission line. This is equivalent to the wave meeting an impedance differing from the line's characteristic impedance.Although applicable at any frequency, S-parameters are mostly used for networks operating at radio frequency (RF) and microwave frequencies where signal power and energy considerations are more easily quantified than currents and voltages. S-parameters change with the measurement frequency, so frequency must be specified for any S-parameter measurements stated, in addition to the characteristic impedance or system impedance.S-parameters are readily represented in matrix form and obey the rules of matrix algebra.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report