• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
DS1232 MicroMonitor Chip
DS1232 MicroMonitor Chip

... A watchdog timer function forces RST and RST signals to the active state when the ST input is not stimulated for a predetermined time period. The time period is set by the TD input to be typically 150 ms with TD connected to ground, 600 ms with TD left unconnected, and 1.2 seconds with TD connected ...
THS452x Very Low Power, Negative Rail Input
THS452x Very Low Power, Negative Rail Input

... These fully differential amplifiers feature accurate output common-mode control that allows for dc-coupling when driving analog-to-digital converters (ADCs). This control, coupled with an input common-mode range below the negative rail as well as rail-to-rail output, allows for easy interfacing betw ...
SPAC 310 C and SPAC 312 C Feeder Terminal
SPAC 310 C and SPAC 312 C Feeder Terminal

... Both the control module SPTO 1D2 and the combined overcurrent and earth-fault module SPCJ 4D29 measures analog signals. The combined overcurrent and earth-fault module measures the three phase currents and the neutral current. The module indicates the current values locally and can transmit the data ...
Table of Contents - Soliton Controles Industriais
Table of Contents - Soliton Controles Industriais

... Data visualization needs to be presented in the most easily interpretable format to the operator. In addition to the standard displays of bar, chart and numeric formats, custom displays (plant mimics) can be created for the series 5000 recorders. The advanced software environment allows for display ...
Intro to Elvis
Intro to Elvis

... testing, and teaching electronic circuits. For the first time, you could take advantage of a complete suite of standard test instruments on your computer and directly interface these instruments to circuits built on a small test station called the National Instruments Educational Laboratory Virtual ...
AVR1505
AVR1505

... AVR1505 6. Run the code. When you change the voltage by turning the potentiometer (as in task1), the LEDs should update if the code is correct 7. If you need to correct something in your code, build the project again and test. Use the IO-view to look at the registers and set breakpoints to do some ...
Triple 8-Bit, 80 MSPS Video D/A Converter With
Triple 8-Bit, 80 MSPS Video D/A Converter With

... The analog output drivers generate a current of which the drive level can be user-modified by choice of an appropriate resistor value RFS, connected to the FSADJ terminal. Refer to the paragraph on output amplitude control for details on how the output drive is affected by the operation mode of the ...
SY89829U Oct05
SY89829U Oct05

... single 1:20 LVPECL Clock Driver. The part is designed for use in low voltage (2.5V/3.3V) applications which require a large number of outputs to drive precisely aligned, ultra low skew signals to their destination. The input is multiplexed from either LVDS or LVPECL by the CLK_SEL pin. The LVDS inpu ...
LTC2404/LTC2408 - 4-/8-Channel 24
LTC2404/LTC2408 - 4-/8-Channel 24

... The LTC®2404/LTC2408 are 4-/8-channel 2.7V to 5.5V micropower 24-bit A/D converters with an integrated oscillator, 4ppm INL and 0.3ppm RMS noise. They use delta-sigma technology and provide single cycle digital filter settling time (no latency delay) for multiplexed applications. The first conversio ...
VERY LOW POWER, NEGATIVE RAIL INPUT, RAIL-TO-RAIL OUTPUT, FULLY DIFFERENTIAL AMPLIFIER THS4521 THS4522
VERY LOW POWER, NEGATIVE RAIL INPUT, RAIL-TO-RAIL OUTPUT, FULLY DIFFERENTIAL AMPLIFIER THS4521 THS4522

... range that includes the negative rail. These amplifiers are designed for low-power data acquisition systems and high-density applications where power dissipation is a critical parameter, and provide exceptional performance in audio applications. The family includes single (THS4521), (THS4522), and q ...
Timing Analysis in Presence of Power Supply and Ground Voltage
Timing Analysis in Presence of Power Supply and Ground Voltage

... timing. As we will show below, if the supplies are allowed to vary by up to 12.5%, one can observe (by simulation) up to 2.4X increase in gate delay, in 0.13µm CMOS. Thus, for today’s and future technology, the issue of circuit timing is tightly coupled to the question of supply voltage drop. To com ...
How to Select Little Logic (Rev. A)
How to Select Little Logic (Rev. A)

... from 1.65 V to 5 V, it allows a mixed mode where the designer can use 1.8 V, 2.5 V, or 3.3 V. The SN74LVCxG logic family input structure is 3.3-V CMOS DC; VIL and VIH fixed levels of 0.8 V and 2 V meet LVTTL, meaning that the threshold voltage of 1.5 V is typically where the transition from a recogn ...
UNISONIC TECHNOLOGIES CO., LTD CD4066
UNISONIC TECHNOLOGIES CO., LTD CD4066

... UNISONIC TECHNOLOGIES CO., LTD CD4066 ...
SR810 User`s Manual - Stanford Research Systems
SR810 User`s Manual - Stanford Research Systems

... The sample measurements described in this section are designed to acquaint the first time user with the SR810 DSP Lock-In Amplifier. Do not be concerned that your measurements do not exactly agree with these exercises. The focus of these measurement exercises is to learn how to use the instrument. I ...
TEK THM 550 Service
TEK THM 550 Service

... Use Proper Power Cord. To avoid fire hazard, use only the power cord specified for the product you are using. Use Proper Voltage Setting. Before applying power, ensure that the line selector is in the proper position for the power source being used. Connect and Disconnect Properly. Do not connect or ...
model sr830 - Stanford Research Systems
model sr830 - Stanford Research Systems

... The sample measurements described in this section are designed to acquaint the first time user with the SR830 DSP Lock-In Amplifier. Do not be concerned that your measurements do not exactly agree with these exercises. The focus of these measurement exercises is to learn how to use the instrument. I ...
Atmel ATtiny45 Appendix A - ATtiny45 Automotive specification at 150°C Description PRELIMINARY DATASHEET
Atmel ATtiny45 Appendix A - ATtiny45 Automotive specification at 150°C Description PRELIMINARY DATASHEET

... The ATtiny45 has been developed and manufactured according to the most stringent quality assurance requirements of ISOTS-16949 and verified during product qualification as per AEC-Q100 grade 0. AEC-Q100 qualification relies on temperature accelerated stress testing. High temperature field usage howe ...
WBK Options User`s Manual
WBK Options User`s Manual

... Analog Expansion Module Important Notice! WaveBook/516E Users WBK option cards for WaveBook/516E are installed at the factory per customer order. Users are not to remove or install cards for these products as the cards are not “plug-andplay” for these devices and erroneous signal values could result ...
MAX44205 180MHz, Low-Noise, Low-Distortion, Fully Differential
MAX44205 180MHz, Low-Noise, Low-Distortion, Fully Differential

... The MAX44205 offers a VOCM input to adjust the output common-mode voltage, eliminating the need for a coupling transformer or AC-coupling capacitors. This adjustable output common-mode voltage allows the MAX44205 to match the input common-mode voltage range of the ADC following it. A proprietary out ...
LTC2424/LTC2428 - 4-/8-Channel 20-Bit
LTC2424/LTC2428 - 4-/8-Channel 20-Bit

... Note 9: The converter is in external SCK mode of operation such that the SCK pin is used as digital input. The frequency of the clock signal driving SCK during the data output is fESCK and is expressed in kHz. Note 10: The converter is in internal SCK mode of operation such that the SCK pin is used ...
A 1 GS/s 6 bits Time-Based Analog-to
A 1 GS/s 6 bits Time-Based Analog-to

... List of Figures Figure 1 : Analog-to-Digital Conversion ....................................................................... 1 Figure 2 : Generic digital signal processing system ...................................................... 2 Figure 3 : Future digital signal processing system.......... ...
TEK P6249 Instruction
TEK P6249 Instruction

... Installing the push-in probe tip. Attach the push-in probe tip by seating the tip into the probe tip socket and pushing the tip in until it is seated. Either end of the tip may be used. Do not force the tip. Also, be careful not to poke yourself with the sharp probe-tip. To remove the tip, gently gr ...
1 - Mohawk Valley Community College
1 - Mohawk Valley Community College

... distortion analyzer and a low distortion generator (generally, THD below 0.01%), although these portions may be bypassed. For components, a selection of standard value ¼ watt carbon film resistors ranging from a few ohms to a few mega ohms is required along with an array of typical capacitor values ...
LTC6404 - 600MHz, Low Noise, High Precision Fully Differential
LTC6404 - 600MHz, Low Noise, High Precision Fully Differential

... Note 11: This parameter is pulse tested. Extended operation with the output shorted may cause junction temperatures to exceed the 125°C limit and is not recommended. See Note 3 for more details. Note 12: Since the LTC6404 is a voltage feedback amplifier with low output impedance, a resistive load is ...
Safety, Protection, and Modification of the Product n
Safety, Protection, and Modification of the Product n

... product itself; foolproof or fail-safe design of a process or line using the system controlled by the product or the product itself; and/or the design and installation of other protective and safety circuits are to be appropriately implemented as the customer deems necessary. (3) Be sure to use the ...
< 1 2 3 4 5 6 7 8 9 ... 97 >

Oscilloscope



An oscilloscope, previously called an oscillograph, and informally known as a scope, CRO (for cathode-ray oscilloscope), or DSO (for the more modern digital storage oscilloscope), is a type of electronic test instrument that allows observation of constantly varying signal voltages, usually as a two-dimensional plot of one or more signals as a function of time. Other signals (such as sound or vibration) can be converted to voltages and displayed.Oscilloscopes are used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others. Modern digital instruments may calculate and display these properties directly. Originally, calculation of these values required manually measuring the waveform against the scales built into the screen of the instrument.The oscilloscope can be adjusted so that repetitive signals can be observed as a continuous shape on the screen. A storage oscilloscope allows single events to be captured by the instrument and displayed for a relatively long time, allowing observation of events too fast to be directly perceptible.Oscilloscopes are used in the sciences, medicine, engineering, and telecommunications industry. General-purpose instruments are used for maintenance of electronic equipment and laboratory work. Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system or to display the waveform of the heartbeat as an electrocardiogram.Before the advent of digital electronics, oscilloscopes used cathode ray tubes (CRTs) as their display element (hence were commonly referred to as CROs) and linear amplifiers for signal processing. Storage oscilloscopes used special storage CRTs to maintain a steady display of a single brief signal. CROs were later largely superseded by digital storage oscilloscopes (DSOs) with thin panel displays, fast analog-to-digital converters and digital signal processors. DSOs without integrated displays (sometimes known as digitisers) are available at lower cost and use a general-purpose digital computer to process and display waveforms.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report