FNA40860 Motion SPM 45 Series FNA40860 Motio
... 3) VFO output is open-drain type. This signal line should be pulled up to the positive side of the MCU or control power supply with a resistor that makes IFO up to 1 mA (please refer to Figure 14). 4) CSP15 of around seven times larger than bootstrap capacitor CBS is recommended. 5) Input signal is ...
... 3) VFO output is open-drain type. This signal line should be pulled up to the positive side of the MCU or control power supply with a resistor that makes IFO up to 1 mA (please refer to Figure 14). 4) CSP15 of around seven times larger than bootstrap capacitor CBS is recommended. 5) Input signal is ...
analog -digital multimeter user`s manual
... short circuit current of 25 A by a fuse 1.6 A/1000V AC/DC in conjunction, with power diodes. The cut-out capacity of the fuse is 10kA at a rated voltage of1000V AC/DC and ohmic load. The 10 A current measuring ranges are protected by a 16A/ 1000V AC/DC fuse. The cut-out capacity of the fuse is 30 kA ...
... short circuit current of 25 A by a fuse 1.6 A/1000V AC/DC in conjunction, with power diodes. The cut-out capacity of the fuse is 10kA at a rated voltage of1000V AC/DC and ohmic load. The 10 A current measuring ranges are protected by a 16A/ 1000V AC/DC fuse. The cut-out capacity of the fuse is 30 kA ...
Op Amps II
... • The project should (ideally) contain both analog and digital • You should work with your lab partner, but individual reports are required for the projects. • The project counts for 20% of your final grade (I grade them) • I will leave copies of some good past projects in the lab (please don’t take ...
... • The project should (ideally) contain both analog and digital • You should work with your lab partner, but individual reports are required for the projects. • The project counts for 20% of your final grade (I grade them) • I will leave copies of some good past projects in the lab (please don’t take ...
a High Speed, Precision Sample-and-Hold Amplifier AD585
... should be provided to minimize the current flow in the path from sensitive points to the system ground point. In this way supply currents and logic-gate return currents are not summed into the same return path as analog signals where they would cause measurement errors. ...
... should be provided to minimize the current flow in the path from sensitive points to the system ground point. In this way supply currents and logic-gate return currents are not summed into the same return path as analog signals where they would cause measurement errors. ...
CC2530 (Rev. B) - Texas Instruments
... The CC2530 is a true system-on-chip (SoC) solution for IEEE 802.15.4, Zigbee and RF4CE applications. It enables robust network nodes to be built with very low total bill-of-material costs. The CC2530 combines the excellent performance of a leading RF transceiver with an industry-standard enhanced 80 ...
... The CC2530 is a true system-on-chip (SoC) solution for IEEE 802.15.4, Zigbee and RF4CE applications. It enables robust network nodes to be built with very low total bill-of-material costs. The CC2530 combines the excellent performance of a leading RF transceiver with an industry-standard enhanced 80 ...
USING THE LM3914-6 L.E.D. BARGRAPH DRIVERS
... this reason, the sensitivity adjusting circuits given in Fig.2c and 2e are to be preferred when accuracy is paramount. The circuits in 2b and 2f will, however, function with power supply voltages down to 3V. Temperature variations, over a 0°C to 70°C range, have a negligible effect, especially if th ...
... this reason, the sensitivity adjusting circuits given in Fig.2c and 2e are to be preferred when accuracy is paramount. The circuits in 2b and 2f will, however, function with power supply voltages down to 3V. Temperature variations, over a 0°C to 70°C range, have a negligible effect, especially if th ...
D/A Converter
... the LSB of the input by 1. This voltage value is a function of the number of input bits and the reference voltage value. - Increasing the number of bits results in a finer resolution - Most DACs in the 12-18 bit range ...
... the LSB of the input by 1. This voltage value is a function of the number of input bits and the reference voltage value. - Increasing the number of bits results in a finer resolution - Most DACs in the 12-18 bit range ...
Set Reset J K Q Q` CLK
... across some section of your circuit where you would like to know the difference in potential. You feed the ‘high’ line to the input of the circuit, the low line to the common ground (the upside down conifer-like symbols). An internal voltage within the voltmeter begins to ramp up from zero (the saw ...
... across some section of your circuit where you would like to know the difference in potential. You feed the ‘high’ line to the input of the circuit, the low line to the common ground (the upside down conifer-like symbols). An internal voltage within the voltmeter begins to ramp up from zero (the saw ...
final documentation - EE Senior Design
... The Voltage Controlled Oscillator (VCO) output a square, ramp or sawtooth wave based on user input. The frequency of this wave can be adjusted over the human hearing spectrum using rough and fine potentiometers. The VCO feeds into the Voltage Controlled Filter (VCF) which applies any combination of ...
... The Voltage Controlled Oscillator (VCO) output a square, ramp or sawtooth wave based on user input. The frequency of this wave can be adjusted over the human hearing spectrum using rough and fine potentiometers. The VCO feeds into the Voltage Controlled Filter (VCF) which applies any combination of ...
NLAS52231 Ultra-Low 0.4 W Dual SPDT Analog Switch with
... The NLAS52231 is a dual SPDT analog switch with overshoot protection on the signal lines. It is ideally suited for audio applications that require very low RON values for maximum signal transfer. The overshoot protection included in the NLAS52231 allows analog signals on the COM, NO or NC lines to s ...
... The NLAS52231 is a dual SPDT analog switch with overshoot protection on the signal lines. It is ideally suited for audio applications that require very low RON values for maximum signal transfer. The overshoot protection included in the NLAS52231 allows analog signals on the COM, NO or NC lines to s ...
electrical measurement laboratory
... must not be worn while working with machinery in the Laboratory. All users must wear full shoes (not sandals) and at least a shirt and full-length trousers. Long hair must be held back securely with a head band or a net. Medallions or jewellery hanging from the neck must not be worn. 4. The bench is ...
... must not be worn while working with machinery in the Laboratory. All users must wear full shoes (not sandals) and at least a shirt and full-length trousers. Long hair must be held back securely with a head band or a net. Medallions or jewellery hanging from the neck must not be worn. 4. The bench is ...
Input Offset Voltage
... Output offset is due to two sources, one is input bias current, the other is input offset voltage. The input bias current of the amplifier is used for the biasing of the differential input-stage transistors. The input offset voltage is the differential input voltage that must be applied across the i ...
... Output offset is due to two sources, one is input bias current, the other is input offset voltage. The input bias current of the amplifier is used for the biasing of the differential input-stage transistors. The input offset voltage is the differential input voltage that must be applied across the i ...
CC2541-Q1 - Texas Instruments
... The CC2541-Q1 is a power-optimized true Wireless MCU solution for both Bluetooth low energy and proprietary 2.4-GHz applications. This device enables the building of robust nework nodes with low total bill-of-material costs. The CC2541-Q1 combines the excellent performance of a leading RF transceive ...
... The CC2541-Q1 is a power-optimized true Wireless MCU solution for both Bluetooth low energy and proprietary 2.4-GHz applications. This device enables the building of robust nework nodes with low total bill-of-material costs. The CC2541-Q1 combines the excellent performance of a leading RF transceive ...
CLC5523 Low Power, Variable Gain Amplifier
... Avmax would be even higher and the distortion would degrade further. It is for this reason that we recommend lower output amplitude if wide gain range are desired. Using a post-amp like the CLC404 or CLC409 would be the best way to preserve dynamic range and yield output amplitudes much higher than ...
... Avmax would be even higher and the distortion would degrade further. It is for this reason that we recommend lower output amplitude if wide gain range are desired. Using a post-amp like the CLC404 or CLC409 would be the best way to preserve dynamic range and yield output amplitudes much higher than ...
Auto-titrating pH Meter
... op-amp is used when one wants to amplify a positive (>0 V) low voltage signal , such as occurs in the low pH range (pH 0 – pH7). ...
... op-amp is used when one wants to amplify a positive (>0 V) low voltage signal , such as occurs in the low pH range (pH 0 – pH7). ...
Design Considerations, Testing and Applications Assistance Form
... It is also often necessary to construct load lines to determine reflection waveforms in line driving applications. The input and output characteristics graphs of section 3 (Figs. 2-4, 2-7 and 2-8) can be very useful for this purpose. OUTPUT RISE AND FALL TIMES provide important information in determ ...
... It is also often necessary to construct load lines to determine reflection waveforms in line driving applications. The input and output characteristics graphs of section 3 (Figs. 2-4, 2-7 and 2-8) can be very useful for this purpose. OUTPUT RISE AND FALL TIMES provide important information in determ ...
LT1187 - Low Power Video Difference Amplifier
... and Q1 (or Q2) turns off. Therefore the maximum input swing is 380mVP or 760mVP-P. The second differential pair, Q3 and Q4, is running at slightly larger current so that when the first input stage limits, the second stage remains biased to maintain the feedback. Occasionally it is necessary to handle ...
... and Q1 (or Q2) turns off. Therefore the maximum input swing is 380mVP or 760mVP-P. The second differential pair, Q3 and Q4, is running at slightly larger current so that when the first input stage limits, the second stage remains biased to maintain the feedback. Occasionally it is necessary to handle ...
SMP04
... output range is typically 3 mV. The hold step is the magnitude of the voltage step caused when switching from sample-to-hold mode. This error is sometimes referred to as the pedestal error or sample-to-hold offset, and is about 2 mV with little variation. The droop rate of a held channel is 2 µV/ms ...
... output range is typically 3 mV. The hold step is the magnitude of the voltage step caused when switching from sample-to-hold mode. This error is sometimes referred to as the pedestal error or sample-to-hold offset, and is about 2 mV with little variation. The droop rate of a held channel is 2 µV/ms ...
Dual-Channel Digital Isolator ADuM1210 FEATURES
... uncertain current transfer ratios, nonlinear transfer functions, and temperature and lifetime effects are eliminated with the simple iCoupler digital interfaces and stable performance characteristics. The need for external drivers and other discrete components is eliminated with iCoupler products. F ...
... uncertain current transfer ratios, nonlinear transfer functions, and temperature and lifetime effects are eliminated with the simple iCoupler digital interfaces and stable performance characteristics. The need for external drivers and other discrete components is eliminated with iCoupler products. F ...
OMC-934 Users Manual
... accept a pulse signal, this input can be used for windspeed or counter, further more one analogue input is available which can be used for potentiometer input. Reference voltage for potmeter provided by the display. The front panel is provided with three buttons for adjusting the brightness of the L ...
... accept a pulse signal, this input can be used for windspeed or counter, further more one analogue input is available which can be used for potentiometer input. Reference voltage for potmeter provided by the display. The front panel is provided with three buttons for adjusting the brightness of the L ...
ULTRAGAIN PRO-8 DIGITAL ADA8000
... The fuse compartment near the power plug socket contains three triangular markings. Two of these triangles are opposite one another. The voltage indicated adjacent to these markings is the voltage to which your unit has been set up, and can be altered by rotating the fuse compartment by 180°. ATTENT ...
... The fuse compartment near the power plug socket contains three triangular markings. Two of these triangles are opposite one another. The voltage indicated adjacent to these markings is the voltage to which your unit has been set up, and can be altered by rotating the fuse compartment by 180°. ATTENT ...
SDD-3000 Manual
... Separate input jacks are provided on the front and rear panels, for maximum convenience. If both Inputs are used the front input has priority and the rear input is internally disconnected. The two inputs are otherwise the same. Input level from either jack is affected by the input ATTENUATOR switch ...
... Separate input jacks are provided on the front and rear panels, for maximum convenience. If both Inputs are used the front input has priority and the rear input is internally disconnected. The two inputs are otherwise the same. Input level from either jack is affected by the input ATTENUATOR switch ...
THS7315 数据资料 dataSheet 下载
... R'G'B' (commonly mislabeled RGB) is also called G'B'R' (again commonly mislabeled as GBR) in professional video systems. The SMPTE component standard stipulates that the luma information is placed on the first channel, the blue color difference is placed on the second channel, and the red color diff ...
... R'G'B' (commonly mislabeled RGB) is also called G'B'R' (again commonly mislabeled as GBR) in professional video systems. The SMPTE component standard stipulates that the luma information is placed on the first channel, the blue color difference is placed on the second channel, and the red color diff ...
Oscilloscope
An oscilloscope, previously called an oscillograph, and informally known as a scope, CRO (for cathode-ray oscilloscope), or DSO (for the more modern digital storage oscilloscope), is a type of electronic test instrument that allows observation of constantly varying signal voltages, usually as a two-dimensional plot of one or more signals as a function of time. Other signals (such as sound or vibration) can be converted to voltages and displayed.Oscilloscopes are used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others. Modern digital instruments may calculate and display these properties directly. Originally, calculation of these values required manually measuring the waveform against the scales built into the screen of the instrument.The oscilloscope can be adjusted so that repetitive signals can be observed as a continuous shape on the screen. A storage oscilloscope allows single events to be captured by the instrument and displayed for a relatively long time, allowing observation of events too fast to be directly perceptible.Oscilloscopes are used in the sciences, medicine, engineering, and telecommunications industry. General-purpose instruments are used for maintenance of electronic equipment and laboratory work. Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system or to display the waveform of the heartbeat as an electrocardiogram.Before the advent of digital electronics, oscilloscopes used cathode ray tubes (CRTs) as their display element (hence were commonly referred to as CROs) and linear amplifiers for signal processing. Storage oscilloscopes used special storage CRTs to maintain a steady display of a single brief signal. CROs were later largely superseded by digital storage oscilloscopes (DSOs) with thin panel displays, fast analog-to-digital converters and digital signal processors. DSOs without integrated displays (sometimes known as digitisers) are available at lower cost and use a general-purpose digital computer to process and display waveforms.