• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AD6640 数据手册DataSheet下载
AD6640 数据手册DataSheet下载

... that the input voltage on either encode pin does not go below 0 V. The maximum value ensures that the input voltage on either ENCODE pin does not go below 2.0 V or above AVCC (e.g., for a differential input swing of 0.8 V, the min and max common-mode specs become 0.4 V and 2.4 V, respectively). ...
General Description Features and Benefits
General Description Features and Benefits

... ●● 9mW at 1.6Msps, Ultra-Low Power Consumption ●● ±6 LSB INL, ~5ppm Over Temperature ●● ±1 LSB DNL Maximum at 20 Bit ●● 98.3dB SNR at fIN = 10kHz ●● 98.1dB SINAD at fIN = 10kHz ●● -123dB THD at fIN = 10kHz ●● ±VREF Unipolar Differential Analog Input Range ●● VREF = 2.5V to 3.6V ...
ADuM1100 数据手册DataSheet下载
ADuM1100 数据手册DataSheet下载

... speed optocouplers, the ADuM1100 supports data rates as high as 25 Mbps and 100 Mbps. The ADuM1100 operates with a voltage supply ranging from 3.0 V to 5.5 V, boasts a propagation delay of <18 ns and edge asymmetry of <2 ns, and is compatible with temperatures up to 125°C. It operates at very low po ...
AD7899 数据手册DataSheet下载
AD7899 数据手册DataSheet下载

... The AD7899 is tested using two input frequencies. In this case, the second and third order terms are of different significance. The second order terms are usually distanced in frequency from the original sine waves while the third order terms are usually at a frequency close to the input frequencies ...
Chapter 3 Special-Purpose Diodes
Chapter 3 Special-Purpose Diodes

... When frequency is low enough, the coupling and bypass capacitors can no longer be considered as shorts because their reactances are large enough to have significant effect. Also, when the frequency is high enough, the internal transistor capacitances can no longer be considered as opens because thei ...
AD7453 数据手册DataSheet下载
AD7453 数据手册DataSheet下载

... reference input is 2.5 V. This pin should be decoupled to GND with a capacitor of at least 0.1 µF. Noninverting Analog Input. Inverting Input. This pin sets the ground reference point for the VIN+ input. Connect to ground or to a dc offset to provide a pseudo ground. Analog Ground. Ground reference ...
Computation of Eddy Current Signals and Quantitative Inversion
Computation of Eddy Current Signals and Quantitative Inversion

... amplitude ...
The CCB external hardware interfaces
The CCB external hardware interfaces

... are discussed in detail in chapter 3, and summarized below, in table 1.1. All of the sockets on both the internal computer box, and the main CCB case, have been selected for their RFI shielding properties, and all signals going through them are either low-pass filtered within the sockets themselves ...
Crosstalk Circuit 2
Crosstalk Circuit 2

... by populating one jumper on each of two header pin sets. The first set is labeled J54, and is shown in Figure 6 with 1 MHz selected. The second set is labeled J71, and provides the clock signal for the remaining experiments. Four frequencies are available including: 1 MHz, 2 MHz, 4 MHz, and 8 MHz. S ...
The external hardware interfaces of the CCB.
The external hardware interfaces of the CCB.

... are discussed in detail in chapter 3, and summarized below, in table 1.1. All of the sockets on both the internal computer box, and the main CCB case, have been selected for their RFI shielding properties, and all signals going through them are either low-pass filtered within the sockets themselves ...
Feb-1977 - HP Labs
Feb-1977 - HP Labs

... cally accounting for gain and offset errors. The basic technique is shown in Fig. 5. By taking readings with the input grounded, then connected to a reference, and finally to the unknown, amplifier offsets and gain errors can be eliminated from the measurement re sults. A microprocessor can be progr ...
ADS5413 数据资料 dataSheet 下载
ADS5413 数据资料 dataSheet 下载

... The ADS5413 is a low power, 12-bit, 65-MSPS, CMOS pipeline analog-to-digital converter (ADC) that operates from a single 3.3-V supply, while offering the choice of digital output levels from 1.8 V to 3.3 V. The low noise, high linearity, and low clock jitter makes the ADC well suited for high-input ...
AD623 instrumentation amplifier
AD623 instrumentation amplifier

... supply. The AD623 offers superior user flexibility by allowing single gain set resistor programming and by conforming to the 8-lead industry standard pinout configuration. With no external resistor, the AD623 is configured for unity gain (G = 1), and with an external resistor, the AD623 can be progr ...
AD8222 数据手册DataSheet 下载
AD8222 数据手册DataSheet 下载

... The AD8222 is a dual-channel, high performance instrumentation amplifier that requires only one external resistor per amplifier to set gains of 1 to 10,000. The AD8222 is the first dual-instrumentation amplifier in the small 4 mm × 4mm LFCSP. It requires the same board area as a typical single instr ...
AD7453 Pseudo Differential, 555 kSPS 12-Bit ADC in an 8
AD7453 Pseudo Differential, 555 kSPS 12-Bit ADC in an 8

... reference input is 2.5 V. This pin should be decoupled to GND with a capacitor of at least 0.1 µF. Noninverting Analog Input. Inverting Input. This pin sets the ground reference point for the VIN+ input. Connect to ground or to a dc offset to provide a pseudo ground. Analog Ground. Ground reference ...
AD7899 5 V Single Supply 14-Bit 400 kSPS ADC
AD7899 5 V Single Supply 14-Bit 400 kSPS ADC

... The AD7899 is tested using two input frequencies. In this case, the second and third order terms are of different significance. The second order terms are usually distanced in frequency from the original sine waves while the third order terms are usually at a frequency close to the input frequencies ...
Tektronix AM503 current probe system, user-manual
Tektronix AM503 current probe system, user-manual

... Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for ...
Triggering on MIL-STD 1553 Signals
Triggering on MIL-STD 1553 Signals

...  The electrical/physical layer of MIL-STD 1553 networks should be characterized to insure good signal integrity for reliable communication.  Using an oscilloscope with built-in MIL-STD 1553 triggering and decoding will enhance your ability to quickly window-in on specific transmitted and received ...
Four White LED Backlight Driver ADM8843  FEATURES
Four White LED Backlight Driver ADM8843 FEATURES

... with VCC input voltages as low as 2.6 V. It also includes regulation of the charge pump output voltage for supply voltages up to 5.5 V. The ADM8843’s four LEDs are arranged into two groups, main and sub. The main display can have up to three LEDs (FB1 to FB3), and the sub display has one LED (FB4) ( ...
Lecture_current feedback amplifier
Lecture_current feedback amplifier

... There are two types of feedback in amplifiers. They are positive feedback , also called regenerative feedback , and negative feedback , also called degenerative feedback. The difference between these two types is whether the feedback signal is in phase or out of phase with the input signal. Positive ...
Lecture_02-DataTransmission
Lecture_02-DataTransmission

... where the signal strength falls off with distance depends on transmission medium It is a increasing function of frequency received signal strength must be: – strong enough to be detected – sufficiently higher than noise so as to receive without error ...
Input Diodes for ac Coupled Circuits
Input Diodes for ac Coupled Circuits

... • During slew rate condition the amplifiers differential voltage may be volts • Volts across back-to-back diodes turns them on. This charges the input capacitor • A “saw tooth” type waveform will only slew on the fast edge. So it only slews in one direction. This will charge the input capacitor on e ...
比较器系列ADCMP606 数据手册DataSheet 下载
比较器系列ADCMP606 数据手册DataSheet 下载

... to the VCCI and VCCO pins. High frequency bypass capacitors should be carefully selected for minimum inductance and ESR. Parasitic layout inductance should also be strictly controlled to maximize the effectiveness of the bypass at high frequencies. ...
Analog Electronics Citcuit Lab manual for B. tech 5th sem.
Analog Electronics Citcuit Lab manual for B. tech 5th sem.

... 3. Vary the input signal frequency from the function generator and observe for the voltage output (Vo) adjust the pot meter R4 to get the overall gain of 10. 4. To observe the frequency response of the first stage disconnects the second stage by removing the right lead of Cc, which is connected, to ...
a CMOS, Low-Voltage, 3-Wire Serially-Controlled, Matrix Switches ADG738/ADG739
a CMOS, Low-Voltage, 3-Wire Serially-Controlled, Matrix Switches ADG738/ADG739

... to one switch of the part. A Logic 1 in the particular bit position turns on the switch, while a Logic 0 turns the switch off. Because each switch is independently controlled by an individual bit, this provides the option of having any, all, or none of the switches ON. This feature may be particular ...
< 1 ... 23 24 25 26 27 28 29 30 31 ... 97 >

Oscilloscope



An oscilloscope, previously called an oscillograph, and informally known as a scope, CRO (for cathode-ray oscilloscope), or DSO (for the more modern digital storage oscilloscope), is a type of electronic test instrument that allows observation of constantly varying signal voltages, usually as a two-dimensional plot of one or more signals as a function of time. Other signals (such as sound or vibration) can be converted to voltages and displayed.Oscilloscopes are used to observe the change of an electrical signal over time, such that voltage and time describe a shape which is continuously graphed against a calibrated scale. The observed waveform can be analyzed for such properties as amplitude, frequency, rise time, time interval, distortion and others. Modern digital instruments may calculate and display these properties directly. Originally, calculation of these values required manually measuring the waveform against the scales built into the screen of the instrument.The oscilloscope can be adjusted so that repetitive signals can be observed as a continuous shape on the screen. A storage oscilloscope allows single events to be captured by the instrument and displayed for a relatively long time, allowing observation of events too fast to be directly perceptible.Oscilloscopes are used in the sciences, medicine, engineering, and telecommunications industry. General-purpose instruments are used for maintenance of electronic equipment and laboratory work. Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system or to display the waveform of the heartbeat as an electrocardiogram.Before the advent of digital electronics, oscilloscopes used cathode ray tubes (CRTs) as their display element (hence were commonly referred to as CROs) and linear amplifiers for signal processing. Storage oscilloscopes used special storage CRTs to maintain a steady display of a single brief signal. CROs were later largely superseded by digital storage oscilloscopes (DSOs) with thin panel displays, fast analog-to-digital converters and digital signal processors. DSOs without integrated displays (sometimes known as digitisers) are available at lower cost and use a general-purpose digital computer to process and display waveforms.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report