1 - Brown University
... 4. Monitor the following status points from each connected transfer switch: Load (amps, KW and KVA), voltage, and transfer switch position (load connected to normal, load connected to Emergency), 5. Monitor the generator run status and alarm status panel alarm points. 6. Meter monitoring shall be vi ...
... 4. Monitor the following status points from each connected transfer switch: Load (amps, KW and KVA), voltage, and transfer switch position (load connected to normal, load connected to Emergency), 5. Monitor the generator run status and alarm status panel alarm points. 6. Meter monitoring shall be vi ...
Heathkit V-7A - Orange County (California) Amateur Radio Club
... The V4A replaced the V-4 in late 1950 or early 1951. The major change was a further modification to the AC to DC conversion circuit which actually brought the circuit back closer to the original V-1 circuit. The V-4A sold for $23.50; a dollar less than the earlier models. The Heathkit V-5 VTVM: The ...
... The V4A replaced the V-4 in late 1950 or early 1951. The major change was a further modification to the AC to DC conversion circuit which actually brought the circuit back closer to the original V-1 circuit. The V-4A sold for $23.50; a dollar less than the earlier models. The Heathkit V-5 VTVM: The ...
Fluke-175, Fluke-177, Fluke-179
... Fluke 73, 77, 175, 177 and 179 Digital Multimeters Versatile meters for maintenance, field service and bench repair. The 170 Series have the features needed to find most electrical, electronic, electro-mechanical and heating and ventilation problems. They are simple to use and have significant impro ...
... Fluke 73, 77, 175, 177 and 179 Digital Multimeters Versatile meters for maintenance, field service and bench repair. The 170 Series have the features needed to find most electrical, electronic, electro-mechanical and heating and ventilation problems. They are simple to use and have significant impro ...
Micronta 22-204A range doubler multimeter instructions
... 0 dB = 1 milliwatt dissipated in a 600 ohm impedance (equivalent to 0.775 volts across 600 ohms). The original manual text above about decibel measurements could be a bit confusing. To try to clarify, 1mW into 600ohms is 0dBu not 0decibels. A decibel on it's own is allways a relative measurement, no ...
... 0 dB = 1 milliwatt dissipated in a 600 ohm impedance (equivalent to 0.775 volts across 600 ohms). The original manual text above about decibel measurements could be a bit confusing. To try to clarify, 1mW into 600ohms is 0dBu not 0decibels. A decibel on it's own is allways a relative measurement, no ...
Minilyzer ML1 User Manual
... • Never connect the instrument to a high voltage output such as a power amplifier, mains power plug, etc. • Do not disassemble the instrument. • Never use the instrument in a damp environment. • Remove the batteries as soon as they are flat or if the instrument is not intended to be used for a l ...
... • Never connect the instrument to a high voltage output such as a power amplifier, mains power plug, etc. • Do not disassemble the instrument. • Never use the instrument in a damp environment. • Remove the batteries as soon as they are flat or if the instrument is not intended to be used for a l ...
Datascope Passport EL Patient Monitor
... ECG:.........................................................Leads: I, II, III Display sensitivity: 0.25, 0.5, 1.0, 2.0, 3.0, 4.0 cm/mV ...
... ECG:.........................................................Leads: I, II, III Display sensitivity: 0.25, 0.5, 1.0, 2.0, 3.0, 4.0 cm/mV ...
PL-2 Analog Peak Limiter Manual Features · Two independent
... · If necessary, replace the 1.5A/250V (5x20mm) SLO-BLO fuse (inside the IEC input socket) only with the same type and rating. How it Works What is a Peak Limiter? It's probably easier to first state what a peak limiter is not it's not a compressor. In its simplest form, a compressor is a device make ...
... · If necessary, replace the 1.5A/250V (5x20mm) SLO-BLO fuse (inside the IEC input socket) only with the same type and rating. How it Works What is a Peak Limiter? It's probably easier to first state what a peak limiter is not it's not a compressor. In its simplest form, a compressor is a device make ...
DCM R Series True RMS Digital Clampmeters DESCRIPTION
... multimeters offer the user many advantages including the measurement of d.c. currents and non-sinusoidal waveforms. High Accuracy Advanced jaw design means that the clampmeters’ accuracy is not actually affected by external magnetic fields or off-centre conductor positioning. Utilisation of Hall Eff ...
... multimeters offer the user many advantages including the measurement of d.c. currents and non-sinusoidal waveforms. High Accuracy Advanced jaw design means that the clampmeters’ accuracy is not actually affected by external magnetic fields or off-centre conductor positioning. Utilisation of Hall Eff ...
Independent Living Aids ILA Item 756246 Digital Multimeter With
... This meter is fully calibrated and tested. Under normal use, no further adjustment should be necessary. ...
... This meter is fully calibrated and tested. Under normal use, no further adjustment should be necessary. ...
ISKRA Model E895G2 Electricity Meter
... This approval becomes subject to review on 1 September 2006, and then every 5 years thereafter. Instruments purporting to comply with this approval shall be marked NSC No 14/2/6 and only by persons authorised by the submittor. It is the submittor’s responsibility to ensure that all instruments marke ...
... This approval becomes subject to review on 1 September 2006, and then every 5 years thereafter. Instruments purporting to comply with this approval shall be marked NSC No 14/2/6 and only by persons authorised by the submittor. It is the submittor’s responsibility to ensure that all instruments marke ...
Issue 22 - HP Archive
... ibrator must be supplied from an external source. The voltage applied to the instrument is monitored at the input to the coaxial attenuator and the low-level output from the attenuator appears in series with a 50-ohm impedance-matching resistor. The rf voltmeter is calibrated to indicate the output ...
... ibrator must be supplied from an external source. The voltage applied to the instrument is monitored at the input to the coaxial attenuator and the low-level output from the attenuator appears in series with a 50-ohm impedance-matching resistor. The rf voltmeter is calibrated to indicate the output ...
SEL-734 Data Sheet
... Select from seven communications ports and eight communications protocols, including 10/100BASE-T or 100BASE-FX Ethernet. Advanced communications and protocols, such as DNP3, reduce the need for analog and digital outputs. When installations must communicate with legacy equipment, SEL offers digital ...
... Select from seven communications ports and eight communications protocols, including 10/100BASE-T or 100BASE-FX Ethernet. Advanced communications and protocols, such as DNP3, reduce the need for analog and digital outputs. When installations must communicate with legacy equipment, SEL offers digital ...
Power meters - OPS Schneider Electric
... G. Voltage Inputs 1. The circuit monitor shall allow connection to circuits up to 480 volts AC without the use of potential transformers. The Power Meter shall also accept voltage inputs from standard instrument potential transformers. The Power Meter shall support PT primaries through 1.6 MV. 2. Th ...
... G. Voltage Inputs 1. The circuit monitor shall allow connection to circuits up to 480 volts AC without the use of potential transformers. The Power Meter shall also accept voltage inputs from standard instrument potential transformers. The Power Meter shall support PT primaries through 1.6 MV. 2. Th ...
Sat Buddy 2 - Applied Instruments
... Signal received without the 22 kHz tone activated is from the 101º satellite. Signal received with the 22kHz tone activated is from the 119º/110º satellite signal. Note: For North American DIRECTV™ multi-satellite antenna installations, do not try to obtain the same measurement for each satellite on ...
... Signal received without the 22 kHz tone activated is from the 101º satellite. Signal received with the 22kHz tone activated is from the 119º/110º satellite signal. Note: For North American DIRECTV™ multi-satellite antenna installations, do not try to obtain the same measurement for each satellite on ...
eautioll Warllillg - technicalaudio.com
... microphone inputs normally are shipped for use with 30-50 ohm microphones. However, the input transformer is provided with a tapped primary so that 250 ohm microphones may be used. Refer to schematic for proper wires to change. 2. Set the equalizer switch at either 7.5 or 15 inch position, depending ...
... microphone inputs normally are shipped for use with 30-50 ohm microphones. However, the input transformer is provided with a tapped primary so that 250 ohm microphones may be used. Refer to schematic for proper wires to change. 2. Set the equalizer switch at either 7.5 or 15 inch position, depending ...
3.0 electrical specifications
... case, the DCCT head design shall be such that a parallel current-carrying return conductor of the same rating as the current being monitored may be installed not less than 2” away from any part of the DCCT. ...
... case, the DCCT head design shall be such that a parallel current-carrying return conductor of the same rating as the current being monitored may be installed not less than 2” away from any part of the DCCT. ...
TM-35JC, TM-35KC, TM-35JF & TM-35KF Panel Temperature Meters 3 1/2 Digit 0.56” LED
... The differential input feature of the TM-35 facilitates temperature measurement using grounded thermocouples. In this configuration, an indirect ground return path is still required to prevent the common mode range of the inputs from being exceeded, but the circuit differs from the single-ended conf ...
... The differential input feature of the TM-35 facilitates temperature measurement using grounded thermocouples. In this configuration, an indirect ground return path is still required to prevent the common mode range of the inputs from being exceeded, but the circuit differs from the single-ended conf ...
Automatic Meter Reading
... Carefully select the technology, there is more to AMR than reading meters. ...
... Carefully select the technology, there is more to AMR than reading meters. ...
Nexus 1500 Transient Recording Power Quality Revenue Meter Advanced Communication and I/O
... System Events (Anti Tampering): the unit provides extensive usage information for detection of unauthorized access. The unit records: • Resets • Programming changes • Password access changes ...
... System Events (Anti Tampering): the unit provides extensive usage information for detection of unauthorized access. The unit records: • Resets • Programming changes • Password access changes ...
Unit 09 Instruments
... The ohmmeter is used to measure resistance. There are two basic types: analog or digital. The common VOM (volt-ohm-milliammeter) contains an ohmmeter. An ohmmeter should always be readjusted to zero when the scale is changed. ...
... The ohmmeter is used to measure resistance. There are two basic types: analog or digital. The common VOM (volt-ohm-milliammeter) contains an ohmmeter. An ohmmeter should always be readjusted to zero when the scale is changed. ...
Logs and Decibels
... This is similar to scientific notation where very large or small numbers are expressed as X 10 to an exponent value. For example 93000000 = 93 x106 ...
... This is similar to scientific notation where very large or small numbers are expressed as X 10 to an exponent value. For example 93000000 = 93 x106 ...
MAGNE-SONIC 300 SERIES 4-20mA LEVEL TRANSMITTERS
... switch is at position 1 and output is still below 20 mA, leave at setting 1 and proceed with step 4. 4. Turn SPAN FINE control slowly counterclockwise (left) until the milliamp meter reads exactly 20 mA. This is the output at 100% full level. Leave SPAN FINE control at this setting. If output canno ...
... switch is at position 1 and output is still below 20 mA, leave at setting 1 and proceed with step 4. 4. Turn SPAN FINE control slowly counterclockwise (left) until the milliamp meter reads exactly 20 mA. This is the output at 100% full level. Leave SPAN FINE control at this setting. If output canno ...
027 - Okonite
... over-insulated for the voltages involved. Note that ICEA does provide these insulation levels for non-NEC applications. Overall, insulation level for shielded medium voltage cables are based on the operating parameters of the system. The choice of 100, 133 or 173% is based on duration of the fault i ...
... over-insulated for the voltages involved. Note that ICEA does provide these insulation levels for non-NEC applications. Overall, insulation level for shielded medium voltage cables are based on the operating parameters of the system. The choice of 100, 133 or 173% is based on duration of the fault i ...
DU-35CL 4-20mA Process Loop 3 1/2 Digit with 0.56” LEDs
... Span input to produce the desired Digital Display Span output. Signal Span is defined as the total change of signal input that would be required for a specific change of the Digital Display. The largest Signal Span that can be specified with a 4 to 20mA input is 16mA. A 4mA Signal Span proportionate ...
... Span input to produce the desired Digital Display Span output. Signal Span is defined as the total change of signal input that would be required for a specific change of the Digital Display. The largest Signal Span that can be specified with a 4 to 20mA input is 16mA. A 4mA Signal Span proportionate ...
Peak programme meter

A peak programme meter (PPM) is an instrument used in professional audio for indicating the level of an audio signal.There are many different kinds of PPM. They fall into broad categories:True peak programme meter. This shows the peak level of the waveform no matter how brief its duration.Quasi peak programme meter (QPPM). This only shows the true level of the peak if it exceeds a certain duration, typically a few milliseconds. On peaks of shorter duration, it will indicate less than the true peak level. The extent of the shortfall is determined by the 'integration time'.Sample peak programme meter (SPPM). This is a PPM for digital audio which shows only peak sample values, not the true waveform peaks (which may fall between samples and be up to 3 dB higher in amplitude). It may have either a 'true' or a 'quasi' integration characteristic.Over-sampling peak programme meter. This is a sample PPM in which the signal has first been over-sampled, typically by a factor of four, to alleviate the problem with a basic sample PPM.In professional usage, where consistent level measurements are needed across an industry, audio level meters often comply with a detailed formal standard. This ensures that all meters that comply with the standard will give the same indication on a given audio signal. The principal standard for PPMs is IEC 60268-10. It describes two different quasi-PPM designs which have their roots in meters originally developed in the 1930s for the AM radio broadcasting networks of Germany (Type I) and the United Kingdom (Type II).The term Peak Programme Meter usually refers to these IEC-specified types and similar designs.PPMs were originally designed for monitoring analogue audio signals but are now also used with digital audio.PPMs do not provide effective loudness monitoring. Newer types of meter do, and there is now a push within the broadcasting industry to move away from traditional level meters such as those featured in this article to two new types: loudness meters based on EBU Tech. 3341 and oversampling true PPMs. The former would be used to standardise broadcast loudness to −23 LUFS and the latter to prevent digital clipping.