Multimeter
... or exposed metal. Check the test leads for continuity. Replace damaged test leads with identical model number or electrical specifications before using the Meter. l Do not apply more than the rated voltage, as marked on the Meter, between the terminals or between any terminal and grounding. l The ro ...
... or exposed metal. Check the test leads for continuity. Replace damaged test leads with identical model number or electrical specifications before using the Meter. l Do not apply more than the rated voltage, as marked on the Meter, between the terminals or between any terminal and grounding. l The ro ...
ssr level control relay module
... SSR 1000 LEVEL CONTROL RELAY MODULE 9. Start-Up Ensure that all wiring to the Level Control Module is correctly installed and the level switches are installed and functioning correctly. The Relay Module is now ready for operation and the supply power to the level control circuit can be applied. Dep ...
... SSR 1000 LEVEL CONTROL RELAY MODULE 9. Start-Up Ensure that all wiring to the Level Control Module is correctly installed and the level switches are installed and functioning correctly. The Relay Module is now ready for operation and the supply power to the level control circuit can be applied. Dep ...
ABCs of DMMs
... current times resistance (see Figure 1). Thus, if any two values in the formula are known, the third can be determined. A DMM makes use of Ohm’s Law to directly measure and display either ohms, amps, or volts. On the following pages, you will see just how easy it is to use a DMM to find the answers ...
... current times resistance (see Figure 1). Thus, if any two values in the formula are known, the third can be determined. A DMM makes use of Ohm’s Law to directly measure and display either ohms, amps, or volts. On the following pages, you will see just how easy it is to use a DMM to find the answers ...
Manual
... with tube technology. Owing to state-of-the-art semi-conductor technology, there is no sound deterioration caused by tube ageing, there are no heat problems and no maintenance required at all. All that remains is the advantage of tube technology: its distinctive ...
... with tube technology. Owing to state-of-the-art semi-conductor technology, there is no sound deterioration caused by tube ageing, there are no heat problems and no maintenance required at all. All that remains is the advantage of tube technology: its distinctive ...
Multimeter MS8240D, MASTECH
... displays max value, and then, “MAX”and “MIN”symbol is blinking. The meter returns to normal operation if “MAX/MIN” key is pressed and held for longer than once second. after pressing the key, A/D will keep working, and the display value are always up dated and kept the maximum or minimum value. (The ...
... displays max value, and then, “MAX”and “MIN”symbol is blinking. The meter returns to normal operation if “MAX/MIN” key is pressed and held for longer than once second. after pressing the key, A/D will keep working, and the display value are always up dated and kept the maximum or minimum value. (The ...
electromagnetic_flowmeters_Samizadeh
... Early magmeters needed a powerful magnetic field to create a signal strong enough to be measured accurately. Units that once drew 300 W can now operate with 10 W to 15 W. These low-power units have some limitations. Check with your supplier, but they typically require relatively high conductivity (1 ...
... Early magmeters needed a powerful magnetic field to create a signal strong enough to be measured accurately. Units that once drew 300 W can now operate with 10 W to 15 W. These low-power units have some limitations. Check with your supplier, but they typically require relatively high conductivity (1 ...
batchmate 1500 - Red Seal Measurement
... decimal point may be keyed into any position). Separate k-factors are provided for the count and rate displays. Thus, batching and totalizing may be done in gallons and rate displayed in litres/hr. The maximum factored count speed is 20,000 Hz. The maximum factored rate is 7 digits. The 16 point lin ...
... decimal point may be keyed into any position). Separate k-factors are provided for the count and rate displays. Thus, batching and totalizing may be done in gallons and rate displayed in litres/hr. The maximum factored count speed is 20,000 Hz. The maximum factored rate is 7 digits. The 16 point lin ...
TPI TPI 122 Compact Digital Multimeter, ACmV, with boot, test leads
... >> Logic Test: Measurement transitions of logic circuits. This feature is useful when testing CMOS and TTL logic circuits. >> Two Hold System: Meters with this feature can hold two readings on the display at the same time >> Digits: Total number of digits that can be displayed. For example, a 3½ dig ...
... >> Logic Test: Measurement transitions of logic circuits. This feature is useful when testing CMOS and TTL logic circuits. >> Two Hold System: Meters with this feature can hold two readings on the display at the same time >> Digits: Total number of digits that can be displayed. For example, a 3½ dig ...
Electric and Natural Gas Service Requirements
... from the transformer to the Point of Delivery (see section 12 for a definition of the Point of Delivery). 7. Electric Service Location and Size The location of the service entrance on the member’s premises is an important consideration to both the member and LVE. The member and LVE must agree on the ...
... from the transformer to the Point of Delivery (see section 12 for a definition of the Point of Delivery). 7. Electric Service Location and Size The location of the service entrance on the member’s premises is an important consideration to both the member and LVE. The member and LVE must agree on the ...
ludlum model 14c survey meter
... Note the (+) and (-) marks inside the battery door. Match the battery polarity to these marks. Close the battery box lid, push down, and turn the quarterturn thumb screw clockwise a fourth of a turn. ...
... Note the (+) and (-) marks inside the battery door. Match the battery polarity to these marks. Close the battery box lid, push down, and turn the quarterturn thumb screw clockwise a fourth of a turn. ...
EMI EMC Considerations for Energy Meters Application Note
... Energy meters are often tampered with by malicious noise sources to manipulate the energy consumption readings. Thus it becomes a requirement for an energy meter to be fully-functional in challenging noisy electromagnetic environments. Because of this, different type-tests are provided in the IEC me ...
... Energy meters are often tampered with by malicious noise sources to manipulate the energy consumption readings. Thus it becomes a requirement for an energy meter to be fully-functional in challenging noisy electromagnetic environments. Because of this, different type-tests are provided in the IEC me ...
PWA Thin Film Power Resistors
... Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular a ...
... Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular a ...
EMG2016 - Faculty of Engineering
... as waves instead of currents and voltages. One of the reasons is the wavelength becomes very short that the current at one point of a long conductor is not the same as that at another point. As a result, the ordinary Circuit Theory can no longer be used for the analysis of transmission lines that ha ...
... as waves instead of currents and voltages. One of the reasons is the wavelength becomes very short that the current at one point of a long conductor is not the same as that at another point. As a result, the ordinary Circuit Theory can no longer be used for the analysis of transmission lines that ha ...
Using a Digital Multimeter
... 4. Why is there a battery symbol on the display? The battery symbol at right appears momentarily in the lower left corner of the meter display when the multimeter is first turned on. If the symbol stays on or flickers, bring the meter to your instructor for immediate replacement. A low battery will ...
... 4. Why is there a battery symbol on the display? The battery symbol at right appears momentarily in the lower left corner of the meter display when the multimeter is first turned on. If the symbol stays on or flickers, bring the meter to your instructor for immediate replacement. A low battery will ...
ADR293 数据手册DataSheet 下载
... In many current-output CMOS DAC applications where the output signal voltage must be of the same polarity as the reference voltage, it is often required to reconfigure a currentswitching DAC into a voltage-switching DAC by using a 1.25 V reference, an op amp, and a pair of resistors. Using a current ...
... In many current-output CMOS DAC applications where the output signal voltage must be of the same polarity as the reference voltage, it is often required to reconfigure a currentswitching DAC into a voltage-switching DAC by using a 1.25 V reference, an op amp, and a pair of resistors. Using a current ...
2350 POWER SERIES Selector Guide
... Specify display reading at full scale input if other than the maximum input value in "A". Ordering example as follows: "Similar to 235100-30-10 except 12 V DC =1200 counts on display and legend is PSI. . ." ...
... Specify display reading at full scale input if other than the maximum input value in "A". Ordering example as follows: "Similar to 235100-30-10 except 12 V DC =1200 counts on display and legend is PSI. . ." ...
80 Series V User Manual
... Each Fluke 20, 70, 80, 170 and 180 Series DMM will be free from defects in material and workmanship for its lifetime. As used herein, “lifetime” is defined as seven years after Fluke discontinues manufacturing the product, but the warranty period shall be at least ten years from the date of purchase ...
... Each Fluke 20, 70, 80, 170 and 180 Series DMM will be free from defects in material and workmanship for its lifetime. As used herein, “lifetime” is defined as seven years after Fluke discontinues manufacturing the product, but the warranty period shall be at least ten years from the date of purchase ...
dc voltage measurements
... which measures are taken to limit the transient overvoltages to an appropriate low level. Note – Examples include protected electronic circuits. ...
... which measures are taken to limit the transient overvoltages to an appropriate low level. Note – Examples include protected electronic circuits. ...
NO OUTPUT (ALL GENERATORS)
... Check stator output power leads for continuity, resistance and grounding. a. There should be continuity between leads. b. The resistance values are shown in table #1. c. There should not be any reading to ground. 10. Check for continuity between the capacitor leads and power leads in the stator. a. ...
... Check stator output power leads for continuity, resistance and grounding. a. There should be continuity between leads. b. The resistance values are shown in table #1. c. There should not be any reading to ground. 10. Check for continuity between the capacitor leads and power leads in the stator. a. ...
UT203/204
... l Inspect the test leads for damaged insulation or exposed metal. Check the test leads for continuity. Replace damaged test leads with identical model number or electrical specifications before using the Meter. l Do not apply more than the rated voltage, as marked on the Meter, between the terminals ...
... l Inspect the test leads for damaged insulation or exposed metal. Check the test leads for continuity. Replace damaged test leads with identical model number or electrical specifications before using the Meter. l Do not apply more than the rated voltage, as marked on the Meter, between the terminals ...
CR14 - Atos
... covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granled subjecl to Ihe conditions as seI out in IECEx Scheme Rules, IECEx 02 and Operational Oocuments as amended. ...
... covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granled subjecl to Ihe conditions as seI out in IECEx Scheme Rules, IECEx 02 and Operational Oocuments as amended. ...
EMG2016 - Faculty of Engineering
... as waves instead of currents and voltages. One of the reasons is the wavelength becomes very short that the current at one point of a long conductor is not the same as that at another point. As a result, the ordinary Circuit Theory can no longer be used for the analysis of transmission lines that ha ...
... as waves instead of currents and voltages. One of the reasons is the wavelength becomes very short that the current at one point of a long conductor is not the same as that at another point. As a result, the ordinary Circuit Theory can no longer be used for the analysis of transmission lines that ha ...
SIMULATION OF THREE, FIVE, SEVEN, NINE, ELEVEN, THIRTEEN
... applications such as utility and large motor drive applications. Multilevel inverters provide more than two voltage levels. A desired output voltage waveform can be synthesized from the multiple voltage levels with less distortion, less switching frequency, higher efficiency, and lower voltage devic ...
... applications such as utility and large motor drive applications. Multilevel inverters provide more than two voltage levels. A desired output voltage waveform can be synthesized from the multiple voltage levels with less distortion, less switching frequency, higher efficiency, and lower voltage devic ...
Hydrostatic Pressure Type
... from the ground level even if the tank is kept below the ground level. • Its cost is low & has reliable design. • It operates over a large temperature range. • There is a choice of corrosion-resistant materials to make these. ...
... from the ground level even if the tank is kept below the ground level. • Its cost is low & has reliable design. • It operates over a large temperature range. • There is a choice of corrosion-resistant materials to make these. ...
Low-Drift Bidirectional Low-Side Current
... Low-side current sensing is desirable because the common-mode voltage is near ground. Therefore the current sensing solution is independent of the bus voltage, Vbus. When sensing bidirectional currents, use a differential amplifier with a reference pin. This allows for the differentiation between po ...
... Low-side current sensing is desirable because the common-mode voltage is near ground. Therefore the current sensing solution is independent of the bus voltage, Vbus. When sensing bidirectional currents, use a differential amplifier with a reference pin. This allows for the differentiation between po ...
Peak programme meter

A peak programme meter (PPM) is an instrument used in professional audio for indicating the level of an audio signal.There are many different kinds of PPM. They fall into broad categories:True peak programme meter. This shows the peak level of the waveform no matter how brief its duration.Quasi peak programme meter (QPPM). This only shows the true level of the peak if it exceeds a certain duration, typically a few milliseconds. On peaks of shorter duration, it will indicate less than the true peak level. The extent of the shortfall is determined by the 'integration time'.Sample peak programme meter (SPPM). This is a PPM for digital audio which shows only peak sample values, not the true waveform peaks (which may fall between samples and be up to 3 dB higher in amplitude). It may have either a 'true' or a 'quasi' integration characteristic.Over-sampling peak programme meter. This is a sample PPM in which the signal has first been over-sampled, typically by a factor of four, to alleviate the problem with a basic sample PPM.In professional usage, where consistent level measurements are needed across an industry, audio level meters often comply with a detailed formal standard. This ensures that all meters that comply with the standard will give the same indication on a given audio signal. The principal standard for PPMs is IEC 60268-10. It describes two different quasi-PPM designs which have their roots in meters originally developed in the 1930s for the AM radio broadcasting networks of Germany (Type I) and the United Kingdom (Type II).The term Peak Programme Meter usually refers to these IEC-specified types and similar designs.PPMs were originally designed for monitoring analogue audio signals but are now also used with digital audio.PPMs do not provide effective loudness monitoring. Newer types of meter do, and there is now a push within the broadcasting industry to move away from traditional level meters such as those featured in this article to two new types: loudness meters based on EBU Tech. 3341 and oversampling true PPMs. The former would be used to standardise broadcast loudness to −23 LUFS and the latter to prevent digital clipping.