• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
RM4TA02 - Schneider Electric
RM4TA02 - Schneider Electric

... 0.3 A at 70 °C 115 V DC-13 conforming to VDE 0660 0.3 A at 70 °C 115 V DC-13 conforming to IEC 60947-5-1/1991 0.1 A at 70 °C 250 V DC-13 conforming to VDE 0660 0.1 A at 70 °C 250 V DC-13 conforming to IEC 60947-5-1/1991 3 A at 70 °C 250 V AC-15 conforming to VDE 0660 3 A at 70 °C 250 V AC-15 conform ...
File - KevinChant.com
File - KevinChant.com

... jewels, also rectifiers, resistors etc. often occurs through the instrument being used with incorrect settings or by overloading. Subject to the limitations of all electro-mechanical devices the CUT-OUT used in this Instrument should reduce the probability of damage resulting from such abuse. Reason ...
Honeywell Submeter Brochure - E-Mon
Honeywell Submeter Brochure - E-Mon

... The PowerSmart Essential power quality meter is a multifunctional power meter measuring over 100 energy parameters for revenue metering, power quality and harmonic analysis. The device can be integrated in panel boards or supplied in a standalone enclosure. The LCD display provides a wealth of meter ...
meter_safety_workpla..
meter_safety_workpla..

... Common Mistakes Made Function Switch in wrong function for attempted measurement • Example: AC or DC voltage measurement with function switch in Ohms. • Most Ideal meters are Overload Protected and the protected levels are listed in the operation manual. – User my get a false sense that the circuit ...
Manual for 2000 Count 3-1/2 Digit Multimeter DMM
Manual for 2000 Count 3-1/2 Digit Multimeter DMM

... not use the Meter if it is damaged or the case (or part of the case) is removed. Look for cracks or missing plastic. Pay attention to the insulation around the connectors. Inspect the test leads for damaged insulation or exposed metal. Check the test leads for continuity. Replace damaged test leads ...
meter_safety_workpla.. - IDEAL INDUSTRIES, INC.
meter_safety_workpla.. - IDEAL INDUSTRIES, INC.

... Common Mistakes Made Function Switch in wrong function for attempted measurement • Example: AC or DC voltage measurement with function switch in Ohms. • Most Ideal meters are Overload Protected and the protected levels are listed in the operation manual. – User my get a false sense that the circuit ...
Users Manual - Test Equipment Depot
Users Manual - Test Equipment Depot

... Read “Safety Information” before using the meter. The Fluke 789 ProcessMeter (referred to as “the meter”) is a handheld, battery-operated tool for measuring electrical parameters, supplying steady or ramping current to test process instruments, and providing a > 24 V loop power supply. It has all t ...
tst_supertester
tst_supertester

... The circuit of the instrument is arranged so that the test leads carrying the alligator clips may be connected directly to the plate of the output valve and chassis, or between the two plates in the case of push-pull amplifiers. Alternately, the leads can be connected, across the primary, or seconda ...
here - RAD 2012
here - RAD 2012

... low as 1fA may be detected HV using this function ...
Word - ITU
Word - ITU

... flux-density levels are expressed as “decibels with respect to one watt per square metre” (symbol: dB(W/m 2)). Similarly, if one watt per hertz is chosen as the spectral reference power density, the absolute spectral power density levels are expressed as “decibels with respect to one watt per hertz” ...
Utility of Activated Nitriles in the Synthesis of Some New
Utility of Activated Nitriles in the Synthesis of Some New

... 10.2 ppm and δ 12.82 ppm, respectively. Moreover, the mass spectrum for the thiazole structure 2 showed a molecular ion peak at m/z = 371 corresponding to a molecular formula (C17H13N3O3S2). The ketene S,S-dithioacetals 3 was prepared by reaction of 4-(2-cyanoacetamido)benzoic acid (1) with carbon d ...
Standard Technology Title: STANDARD FOR PARTICULAR
Standard Technology Title: STANDARD FOR PARTICULAR

... requirements to achieve the standardisation of prepayment meters within Eskom and to ensure that the equipment will fulfil Eskom's specific needs. Since the original development of the Electricity Dispenser (ED), various other concepts for prepayment meters have been developed. While this specificat ...
Model 9005-A - HI
Model 9005-A - HI

... connect both test leads at once. Instead, clip one probe to the neutral or ground lead of the circuit (usually a bare, green, or white wire in AC wiring circuits) using the insulated slip-on Alligator Clips. Then probe for voltages with the other test lead. This helps prevent you from accidentally t ...
Electric Power Around The World
Electric Power Around The World

... either 50 or 60 Hz are found, depending on the part of the city (50 Hz most common). Actual voltage may vary from area to ...
special electric rules
special electric rules

... Where the timing element serves only to measure the demand interval, it should be adjusted if its rate is more than plus or minus 2 percent in error. Where the timing element serves also to keep a record of the time of day at which the demand occurs, it should be adjusted if its average rate is more ...
UM-35CLE 4-20mA Process Loop 3 1/2 DIGIT with 0.56” or 0.8” LEDs
UM-35CLE 4-20mA Process Loop 3 1/2 DIGIT with 0.56” or 0.8” LEDs

... CN-PUSH/UM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100/120V AC CN-PUSH/UM01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200/240V AC CN-PUSH/UM02 . . . . . . . . . . . . . . . . . . .Switch Selectable 120/240V AC CN-PUSH/UM03 . . . . . . . . . . . ...
Multifunction Process Calibrator
Multifunction Process Calibrator

... manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present Double insulation ...
62-0415 E-Mon Green Class Meter Manual
62-0415 E-Mon Green Class Meter Manual

... a. To ensure a safe installation, the Green Class meter requires an external switch mechanism, such as a circuit breaker, be installed on the Green Class MAINS input wiring. The switch mechanism must be installed in close proximity to the meter and easily reachable for the operator. This device must ...
62-0388 Class 1000 Meter Installation Manual
62-0388 Class 1000 Meter Installation Manual

... To ensure a safe installation, the Class 1000 meter requires an external switch mechanism, such as a circuit breaker, be installed on the Class 1000 MAINS input wiring. The switch mechanism must be installed in close proximity to the meter and easily reachable for the operator. This device must also ...
d40 level switch
d40 level switch

... The displacer suspended from the switch fits easily inside 50mm PVC pipe. This feature allows the D40 to be quickly and easily mounted in stilling wells, stand off housings and shrouded risers. Such mounting arrangements can be easily made from standard PVC pipe and fittings. The D40 level switch ha ...
A Power Meter Reference Design Based on the
A Power Meter Reference Design Based on the

... This application note describes a high-accuracy, low-cost power meter based on the ADE7756. The design is for use in the North American 3-wire/single-phase application. This meter may also be used in a single-phase, 2-wire distribution system with a minimal amount of changes. The reference design is ...
Meters - Schuylkill Technology Center
Meters - Schuylkill Technology Center

... 3.1.12.A Apply concepts of systems, subsystems feedback and control to solve complex technological problems 3.1.12.B Apply concepts of models as a method predict and understand science and technology 3.1.12.C Assess and apply patterns in science and technology 3.1.12D Analyze scale as a way of relat ...
Using a Digital Multimeter
Using a Digital Multimeter

... 4. Why is there a battery symbol on the display? The battery symbol at right appears momentarily in the lower left corner of the meter display when the multimeter is first turned on. If the symbol stays on or flickers, the battery is running low; bring it to your instructor for immediate replacement ...
pro mpa ii ™ user`s guide
pro mpa ii ™ user`s guide

... In the “Normal” (OUT) position, the tube distortion gradually rises until it smoothly clips. The tube is run almost completely open-loop in this mode, providing a musical tube “crunch” when overdriven with a natural recovery from clipping. The tube section can be more easily overdriven when the gai ...
ABR2S112B - OPS Schneider Electric
ABR2S112B - OPS Schneider Electric

... 1.7 A DC-12 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1 1.5 A DC-13 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1 3 A AC-12 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1 1 A AC-15 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1 1 A AC-14 Ue: 230 V per 100000 ...
< 1 ... 8 9 10 11 12 13 14 15 16 ... 36 >

Peak programme meter



A peak programme meter (PPM) is an instrument used in professional audio for indicating the level of an audio signal.There are many different kinds of PPM. They fall into broad categories:True peak programme meter. This shows the peak level of the waveform no matter how brief its duration.Quasi peak programme meter (QPPM). This only shows the true level of the peak if it exceeds a certain duration, typically a few milliseconds. On peaks of shorter duration, it will indicate less than the true peak level. The extent of the shortfall is determined by the 'integration time'.Sample peak programme meter (SPPM). This is a PPM for digital audio which shows only peak sample values, not the true waveform peaks (which may fall between samples and be up to 3 dB higher in amplitude). It may have either a 'true' or a 'quasi' integration characteristic.Over-sampling peak programme meter. This is a sample PPM in which the signal has first been over-sampled, typically by a factor of four, to alleviate the problem with a basic sample PPM.In professional usage, where consistent level measurements are needed across an industry, audio level meters often comply with a detailed formal standard. This ensures that all meters that comply with the standard will give the same indication on a given audio signal. The principal standard for PPMs is IEC 60268-10. It describes two different quasi-PPM designs which have their roots in meters originally developed in the 1930s for the AM radio broadcasting networks of Germany (Type I) and the United Kingdom (Type II).The term Peak Programme Meter usually refers to these IEC-specified types and similar designs.PPMs were originally designed for monitoring analogue audio signals but are now also used with digital audio.PPMs do not provide effective loudness monitoring. Newer types of meter do, and there is now a push within the broadcasting industry to move away from traditional level meters such as those featured in this article to two new types: loudness meters based on EBU Tech. 3341 and oversampling true PPMs. The former would be used to standardise broadcast loudness to −23 LUFS and the latter to prevent digital clipping.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report