• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AN-9066  UniFET — Optimized Switch for Discontinuous Current
AN-9066 UniFET — Optimized Switch for Discontinuous Current

... the UniFET outperforms the super-junction device as gate resistance becomes larger. The only test point where the super-junction device does better than the UniFET is at the lowest current and the smallest gate resistor. The power loss during switching-on transition has not been evaluated because it ...
Performance evaluation of sinusoidal and Space Vector Pulse
Performance evaluation of sinusoidal and Space Vector Pulse

... and energy loses over long power transmission network. It is believed that distributed generation is capable of avoiding the need for the development of new transmission and distribution lines. At the minimum, the grid has to be available as a backup supply so as to increase the system reliability a ...
Fundamentals of Linear Electronics Integrated & Discrete
Fundamentals of Linear Electronics Integrated & Discrete

... suspects are the components under high stress. Stresses are high current, high voltage, and high temperature. Power supplies can have all three ingredients. • Diodes can “pop”, often from too much surge current into the filter capacitor. ...
a grid-connected dual voltage source inverter with
a grid-connected dual voltage source inverter with

reactive power control of isolated wind
reactive power control of isolated wind

INTRODUCING the greatest advancement in ductless
INTRODUCING the greatest advancement in ductless

... * Potting is the process of epoxy filling a complete electronic assembly for resistance to shock, vibration, moisture, chemical and promotes sound dampening. ...
High-efficiency power conversion with silicon
High-efficiency power conversion with silicon

TIA-4000 Optical/Electrical Converter
TIA-4000 Optical/Electrical Converter

ECE 310 - Departments | Engineering at Illinois
ECE 310 - Departments | Engineering at Illinois

... Then a balanced three phase fault occurs at the terminal of one of the lines. The fault is cleared by the opening of this line’s circuit breakers. ...
DN-103 Controlling a -5V Rail Using UCC2913 +3V to +8V Hot-Swap Power Manager
DN-103 Controlling a -5V Rail Using UCC2913 +3V to +8V Hot-Swap Power Manager

... Amplifier and Overcurrent comparators and therefore allows direct connection from the sense resistor to the CSP and CSN pins. The external n-channel MOSFET should be placed between the load and the input source (–5V) to provide adequate gate drive voltage when the load is switched on. ...
Doubly fed induction generator systems for wind turbines
Doubly fed induction generator systems for wind turbines

... power (Table 1). It is anticipated that in the near future, power rating of wind turbines will increase further, especially in offshore applications. For example, the prototype of a Nordex N80 with a rated power of 2.5 MW was installed in March 2000 near Aachen. Many low-power wind turbines built to ...
Electricalengineerin.. - Engineers Institute of India
Electricalengineerin.. - Engineers Institute of India

Thick Film Pulse Limitations
Thick Film Pulse Limitations

Unit 8: Electronic Circuit Design and Construction
Unit 8: Electronic Circuit Design and Construction

Flashlights
Flashlights

... Electric charges lose kinetic energy while moving through metals Electric charges will not coast through metals and must be pushed through Because electric fields push on electric charges, current flows through metal only if that metal has an electric field in it ...
SSPA 0.5-2.5-50 DS_SSPA 0.5-2.5-50 DS.qxd
SSPA 0.5-2.5-50 DS_SSPA 0.5-2.5-50 DS.qxd

AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter ISO9001  Certified
AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter ISO9001 Certified

...  High accuracy, low cost split core 333mV CTs are supplied for simple clamp-on installation- no shoring block and power shutdown is needed   during installation, which is ideal for retrofit projects ...
Distributed Integrated Circuits: Wideband Communications for the
Distributed Integrated Circuits: Wideband Communications for the

... rent gain (the ratio of the output current to input current) of a transistor drops to unity. While the unity-gain frequency of a transistor provides an approximate measure to compare transistors in different technologies, the circuits built using these transistors scarcely operate close to the fT an ...
Iris Power PDAlert Bantam PD Detection During Short Risetime Voltage Surges
Iris Power PDAlert Bantam PD Detection During Short Risetime Voltage Surges

... The introduction of modern voltage source, pulse width modulated inverters using IGBTs/IGCTs in the early 1990s created a new stator winding failure mechanism in motors rated as low as 440 V. In “random wound” motor stator windings typical of motors rated less than 1000 V, partial discharges were fo ...
TSM-HV50 Thyristor-Module for dynamic Power Factor Correction
TSM-HV50 Thyristor-Module for dynamic Power Factor Correction

... from the PFC-controller or an adequate control system) fed in at the connection X1 (signal). If an increase of the stage output is needed, a cascading of several modules is possible. ...
Electromagnetism
Electromagnetism

phase shift - Controlled Power Company
phase shift - Controlled Power Company

... obtain substantial values of leakage inductance between the primary and secondary circuits. The leakage inductance isolates the primary from secondary load variations, providing excellent regulation. The magnetic shunts also represent a parallel path for the power to pass from primary to secondary, ...
C6200 Generator Controller Application
C6200 Generator Controller Application

... open collector outputs can be used. The open collector outputs will then control ...
PDF
PDF

... collaborate unfavorably with power system equipment like motors and transformers causing over loading, overheating and additional losses and can also create interference with the telecommunication system and may lead to erroneous operation in metering devices. Due to these detrimental effects Standa ...
EDIBON
EDIBON

... Compatible with actual Windows operating systems. Graphic and intuitive simulation of the process in screen. Compatible with the industry standards. Registration and visualization of all process variables in an automatic and simultaneously way. Flexible, open and multicontrol software, developed wit ...
< 1 ... 436 437 438 439 440 441 442 443 444 ... 561 >

Electric power system



An electric power system is a network of electrical components used to supply, transmit and use electric power. An example of an electric power system is the network that supplies a region's homes and industry with power—for sizable regions, this power system is known as the grid and can be broadly divided into the generators that supply the power, the transmission system that carries the power from the generating centres to the load centres and the distribution system that feeds the power to nearby homes and industries. Smaller power systems are also found in industry, hospitals, commercial buildings and homes. The majority of these systems rely upon three-phase AC power—the standard for large-scale power transmission and distribution across the modern world. Specialised power systems that do not always rely upon three-phase AC power are found in aircraft, electric rail systems, ocean liners and automobiles.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report