• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
RAL Template
RAL Template

... through each magnet. • Permit DC bias current through split choke secondary winding • Power required is to make up for the resistive losses in the copper, ac losses in the magnets and power supply losses. IM = IDC – IAC cos ω t Total of 1.75MW ...
experiment 1 - Portal UniMAP
experiment 1 - Portal UniMAP

... Figure 1-1 The Power Triangle AC motors draw inductive reactive power from the ac power supply to create the magnetic field which they require. In addition, ac motors absorb active power, most of which is converted to mechanical power and dissipate the remainder as heat. The reactive power travels b ...
Model 648 Electromagnet Power Supply
Model 648 Electromagnet Power Supply

... designed for high precision laboratory use requiring extremely low electrical noise. The linear design removes undesirable higher frequency noise typical of switch mode power supplies. Eliminating the need for external switching or operator intervention to reverse current polarity, the Model 648 use ...
PDF only - at www.arxiv.org.
PDF only - at www.arxiv.org.

... from source to destination in order to reduce high transmission losses. Nicola Tesla is the pioneer of the wireless power transmission concept and he implemented his concept in 1902 with the technologies available at that time. Since then, many of the scientists involved in further extension of this ...
Hybrid Power Generation System
Hybrid Power Generation System

IOSR Journal of Electrical and Electronics Engineering (IOSRJEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSRJEEE)

... supply and for low-power applications and represents an economically attractive alternative to UPS, since no energy storage (battery) is necessary and the overall rating of the components is smaller. The series active filter injects a voltage component in series with the supply voltage and therefore ...
Glossary
Glossary

... limited to 320 amps and/or 240 volts. The meter is connected directly to the customer’s electrical service wires so if the meter is removed, the power to the premise will be de-energized. Customer load requirements pass directly through the meter, meaning it records consumption and demand directly f ...
• DC Standby Systems
• DC Standby Systems

IXAN0068 - IXYS Corporation
IXAN0068 - IXYS Corporation

... cannot be used when computing its thermal limitations in linear applications. For this case, one must use its SOA rating of 240W at VDS = 800V, ID = 0.3A and TC = 90oC. Assuming a 20% safety margin, this reduces its allowable power dissipation to 192W. The maximum output power for the power supply i ...
Stakeholder Comment and Rationale Form  AESO AUTHORITATIVE DOCUMENT PROCESS Stakeholder Consultation Draft
Stakeholder Comment and Rationale Form AESO AUTHORITATIVE DOCUMENT PROCESS Stakeholder Consultation Draft

... Listed below is the summary description of changes for the proposed new, removed or amended sections of the ISO rules. Please refer back to the Letter of Notice under the “Attachments to Letter of Notice” section to view the actual proposed content changes to the ISO rules. Please place your comment ...
Bulk Electric System Definition Review - 05/10/2011
Bulk Electric System Definition Review - 05/10/2011

... and transmission services) that is required to support the reliable operation of the interconnected bulk electric systems. 004-0.17 Reliability Coordinator (RC) - The entity with the highest level of authority that has responsibility for the reliable operation of the bulk electric system, has the wi ...
Parallel Operation of Shunt Active Power Filters for Damping of
Parallel Operation of Shunt Active Power Filters for Damping of

... time on a particular harmonic to be eliminated and if better results arc needed, multiple passive filters are utilizcd [ 3 ] . In thc electric ship, where the loads are always changing and the frequencies of harmonic disturbances are often unknown, it would be difficult to tune passive filters. Furt ...
CFL Light Dimmer
CFL Light Dimmer

... • High Voltage for Ignition • High-Frequency AC current during running – High-Frequency DC to AC conversion (output) ...
DC25617623
DC25617623

... economical energy generation. As an example, in European Union, in 2008 one third of the 23.85GW power generation was from wind turbine generators (WTG). As induction generator, which is the major source of reactive power, is connected with a wind turbine to generate electricity, the compensation of ...
GI3311211125
GI3311211125

September 2009 - 3mm × 3mm, 16-Bit ADC Brings Accurate, Precise High Side Current Sensing to Tight Spaces
September 2009 - 3mm × 3mm, 16-Bit ADC Brings Accurate, Precise High Side Current Sensing to Tight Spaces

... Power monitoring circuits are increasingly used throughout automotive, industrial, communications and computing applications as electronics designers strive to continually improve thermal performance, increase efficiency and generally make their products more “green.” The problem is that power monit ...
AN2063 - STMicroelectronics
AN2063 - STMicroelectronics

... the low minimum operation current with the typical value of 150 A. This feature is quite useful, because the biasing resistor can be removed without any voltage regulation performance loss. With this device, the power losses can be saved on the biasing resistor with typical value of 5-8 mW. The TL43 ...
safe limits pamphlet - Battle River Power Coop
safe limits pamphlet - Battle River Power Coop

... Q&A What is a safe limit of approach? It is the minimum safe distance between a person/equipment and a power line that is legislated to protect the public. ...
DESIGNING A WIND TURBINE WITH PERMANENT MAGNET
DESIGNING A WIND TURBINE WITH PERMANENT MAGNET

... The proposed system is shown in Figure 2 (b). In this topology, generator is connected through an uncontrolled rectifier on the generator side and the inverter on the grid side. The uncontrolled rectifier is used for getting the control system easier. The generator side converter controls the electr ...
5 – The Power BJT 4
5 – The Power BJT 4

... winding (VS ) of TR1 a positive current flows into the base of the power transistor TP which switches on (resistor R1 limits the base current). The capacitor C1 is charged by (VS –VD1– VBE ) and T1 is kept blocked because the diode D1 reverse biases T1 base–emitter. When VS is zipped off, the capaci ...
the Datasheet - AEB Sapphire Corporation AEB Sapphire
the Datasheet - AEB Sapphire Corporation AEB Sapphire

... 1.7" creepage distance - input to output Flexible input, output configurations available Permissible input voltage range + 10% of rated 3% output regulation and low ripple (single output) 1 Watt output ...
Power Consumption by Integrated Circuits
Power Consumption by Integrated Circuits

... done (zero power when idle) • To minimize energy consumption, at which frequency should the processor run? – f ≥ L/T (in order to meet the deadline) – E=P ∙ t= a∙C ∙V2 ∙f ∙t= a∙C ∙V2 ∙L – f=???? ...
G046033742
G046033742

... power and sinusoidal current compensation is exploited. And the proposed control scheme is designed to correct the power factor. In order to correct the power factor, a power factor control loop is required and therefore included in the control block. The DC voltage across the DC link capacitor must ...
Varistors FBMOV Datasheet
Varistors FBMOV Datasheet

... The Littelfuse FBMOV Series thermally protected and non-fragmenting varistor represents a new development in circuit protection. It consists of a 40kA varistor building block (MOV) with an integral thermally activated element designed to open in the event of overheating due to abnormal over-voltage, ...
AG Series auto-reset-instructions-8-02.p65
AG Series auto-reset-instructions-8-02.p65

... fields that cancel, a condition known as “Zero Sum Current”. If any current leaks to ground (Ground Fault), the two currents become unbalanced and there is a net resulting magnetic field. The AG sensor detects this minute field and changes the output state. This concept extends to three phase system ...
< 1 ... 433 434 435 436 437 438 439 440 441 ... 561 >

Electric power system



An electric power system is a network of electrical components used to supply, transmit and use electric power. An example of an electric power system is the network that supplies a region's homes and industry with power—for sizable regions, this power system is known as the grid and can be broadly divided into the generators that supply the power, the transmission system that carries the power from the generating centres to the load centres and the distribution system that feeds the power to nearby homes and industries. Smaller power systems are also found in industry, hospitals, commercial buildings and homes. The majority of these systems rely upon three-phase AC power—the standard for large-scale power transmission and distribution across the modern world. Specialised power systems that do not always rely upon three-phase AC power are found in aircraft, electric rail systems, ocean liners and automobiles.