• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
J.M. Rivas, J. Shafran, R.S. Wahby, and D.J. Perreault, “New Architectures for Radio-Frequency dc/dc Power Conversion,” 2004 IEEE Power Electronics Specialists Conference, Aachen, Germany, June 2004, pp. 4074-4084.
J.M. Rivas, J. Shafran, R.S. Wahby, and D.J. Perreault, “New Architectures for Radio-Frequency dc/dc Power Conversion,” 2004 IEEE Power Electronics Specialists Conference, Aachen, Germany, June 2004, pp. 4074-4084.

... of frequency-dependent losses on magnetic component size. At high frequencies, loss limits—rather than energy storage limits—are the dominant consideration in sizing magnetics. The core loss densities of most power ferrite materials rise rapidly with frequency in the megahertz range, necessitating f ...
Bull Electrical.qxd
Bull Electrical.qxd

... ground connection for the input circuitry and a separate ground pin for the output stage. The printed circuit board (p.c.b.) layouts have been designed to maintain this isolation, and care should be taken to ground the signal inputs and connect the negative power supply lead to the designated points ...
PDF
PDF

... the sign of the last perturbation and the sign of the last increment in the power are used to decide what the next perturbation should be. If there is an increment in the power, the perturbation should be kept in the same direction and if the power decreases, then the next perturbation should be in ...
RC Snubber
RC Snubber

... in a synchronous buck converter. The ringing causes fare amount of switching loss and EMI noise, which may affect the normal operation of the IC sometime. In addition, extra voltage stress from the ringing calls for higher voltage rating Mosfet, which results in higher conduction loss due to higher ...
POWER QUALITY DISTURBANCE ON PERFORMANCE OF
POWER QUALITY DISTURBANCE ON PERFORMANCE OF

... (affecting isolation), overvoltage (reducing expected life time), and under voltage (causing overheating and low speed) . There are several power quality issues which until today were normally not included in motor protection studies. However, they should be taken into consideration due to their inc ...
Music IC Alarm IC More about the ICs in Snap Circuits
Music IC Alarm IC More about the ICs in Snap Circuits

CryoRadTol - Indico
CryoRadTol - Indico

... The readout channels performance is within the expectations in spite of a very ambitious goal in what concern targeted uncertainty and large scale deployment for the measurement of temperature in the 1.7 to 2.2 K range. The LHC has been, not only procured with electronic readouts as good as those pr ...
the Medium Voltage Controllable Fuse Brochure
the Medium Voltage Controllable Fuse Brochure

... System is designed to mitigate the Arc-Flash hazard on the low-voltage side of a medium voltage transformer. The industry’s first fuse to provide normal short-circuit and overload protection while having the capability to open on command, this fuse is a cost effective arc flash solution with minimal ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... The aim of this research is to model an autonomous control wind turbine driven permanent magnetic synchronous generator.(PMSG) which feeds alternating current (AC) power to the utility grid. Furthermore, this research also demonstrates the effects and the efficiency of PMSG wind turbine which is int ...
Model Y5020
Model Y5020

Single and Three Phase Overhead Transformer
Single and Three Phase Overhead Transformer

... are specifically designed to serve residential overhead distribution loads. The y arc also suitable for light commercial loads, industrial lighting, and diversified power applications. Power Partners provides a complete line of overhead transformers to meet the applications of any distribution syste ...
Voltage balance and control in a multi
Voltage balance and control in a multi

... scheme considered here the commutation angles are fixed and , is freely variable. only the phase displacement, The chosen shunt reactive control loop, Fig. 11, is similar to that of a STATCOM that uses a VSI with a fixed switching pattern. In such a STATCOM, the reactive power depends on the voltage ...
Corcom Product Guide 7. Technical Notes — Table of Contents
Corcom Product Guide 7. Technical Notes — Table of Contents

... RFI power line filters are components and therefore not covered by the CE requirements, but they are used in electronic systems to meet EMC specifications. Two of the most common emission specifications are EN 55011 for industrial, science, and medical equipment, and EN 55022 for information technology ...
PowerMonitor 5000 - The Next Generation
PowerMonitor 5000 - The Next Generation

... How the PowerMonitor 5000 Is Network Configured The PowerMonitor 5000 has a native USB port and a native EtherNet I/P port that can be used for configuration or viewing metering data. There is also an optional communication port that lets you install a second EtherNet I/P, DeviceNet, or ControlNet c ...
X-Ray Generators
X-Ray Generators

... Filament Transformer Changes AC voltage to smaller voltage required by filament (8-12 volts typical) ...
Aalborg Universitet Hierarchical Controlled Grid-Connected Microgrid based on a Novel Autonomous
Aalborg Universitet Hierarchical Controlled Grid-Connected Microgrid based on a Novel Autonomous

... performance. Simulation results from a two grid-connected paralleled VCIs system is shown to verify the effectiveness of the designed system. The paper is organized as follows. Section II introduces the operation modes transition. Section III presents the configuration and design of the hierarchical ...
curriculum of 2015
curriculum of 2015

... 1. Identification of meters and electrical components and Residential house wiring using switches, fuse, indicator, lamp and energy meter. 2. Fluorescent lamp wiring and Stair case wiring. 3. Measurement of electrical quantities – voltage, current, power & power factor in RLC circuit. 4. Measurement ...
MX341 AUTOMATIC VOLTAGE REGULATOR (AVR)
MX341 AUTOMATIC VOLTAGE REGULATOR (AVR)

Eliminate Reactive Power and Increase System Efficiency of Isolated Bidirectional
Eliminate Reactive Power and Increase System Efficiency of Isolated Bidirectional

... output power P = 0). When V2 = nV1 , there is always a current flowing in the transformer, except for D = 0. This current contributes to the reactive power in the circuit. Fig. 2(b) shows the peak current in steady-state operation as a function of leakage inductance and output power. It can be seen ...
MS1040 product datasheet
MS1040 product datasheet

A Soft-Switching Isolated Bidirectional Converter Fed
A Soft-Switching Isolated Bidirectional Converter Fed

... So, only the operating principle for G > 1 is analyzed in this paper. A. io > 0 When energy generated in the distributed system is not suf- ficient, the ESS (battery) is discharged to deliver energy to theload, so the output current of the bidirectional converter is positive. In this discharging mo ...
chapter 4 pitch control of wind turbine generators
chapter 4 pitch control of wind turbine generators

... world basis. India has one of the fifth largest wind power installed capacity in the world. This chapter describes the modeling of the various components in a pitch controlled wind energy system. It also describes the design of the pitch controller and discusses the response of the pitch-controlled ...
Document
Document

... • Expensive dc cabling is also minimized making the installation potentially cheaper than a large, central inverter • Large, central inverter systems providing three-phase power to the grid are also an option ...
Capacitor bank
Capacitor bank

... C is a capacitor bank of equivalent resistance R and self-inductance L. It drives a pair of EWAs and a pair of ballast inductors when switch S1 is closed. The load is attached between the nodes A and B when S2 closes, near the moment of peak voltage across both EWAs. ...
2-Level and 3-Level Inverter Topologies for Micro Grid
2-Level and 3-Level Inverter Topologies for Micro Grid

... Renewable energy sources (RESs) have experienced a rapid growth in the last decade due to technological improvements, which have progressively reduced their costs and increased their efficiency at the same time [1]. Moreover, the need to depend less on fossil fuels and to reduce emissions of greenho ...
< 1 ... 244 245 246 247 248 249 250 251 252 ... 561 >

Electric power system



An electric power system is a network of electrical components used to supply, transmit and use electric power. An example of an electric power system is the network that supplies a region's homes and industry with power—for sizable regions, this power system is known as the grid and can be broadly divided into the generators that supply the power, the transmission system that carries the power from the generating centres to the load centres and the distribution system that feeds the power to nearby homes and industries. Smaller power systems are also found in industry, hospitals, commercial buildings and homes. The majority of these systems rely upon three-phase AC power—the standard for large-scale power transmission and distribution across the modern world. Specialised power systems that do not always rely upon three-phase AC power are found in aircraft, electric rail systems, ocean liners and automobiles.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report