• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Fault Analysis In Transmission System Using Matlab
Fault Analysis In Transmission System Using Matlab

... Symmetric faults can be analyzed via the same methods as any other phenomena in power systems, and in fact many software tools exist to accomplish this type of analysis automatically. However, there is another method which is as accurate and is usually more instructive. First, some simplifying assum ...
International Electrical Engineering Journal (IEEJ) Vol. 7 (2016) No.3, pp. 2182-2187
International Electrical Engineering Journal (IEEJ) Vol. 7 (2016) No.3, pp. 2182-2187

... special place in different parts and fuzzy system superiority to classical control has been proved. In this study, the power system stabilizer is used to damp power system oscillations based on the fuzzy logic controller. A three-phase to ground fault during 10 ms is used to evaluate power system os ...
operating instructions
operating instructions

... The V-Type V8 is powered by eight KT88’s. These are configured for GRID BIASED CLASS A/B. This is the traditional arrangement for a high powered amplifier of this type, to efficiently produce approximately 400 watts with the valves supplied (at the rated nominal mains input voltage). ...
Instructions Manual - 7.4v 5A Balance Charger - All
Instructions Manual - 7.4v 5A Balance Charger - All

... Instructions Manual ‐ 7.4v 5A Balance Charger  Powering the Charger  A power supply is not provided with this charger.  The users need to provide their own power supply to  operate this charger.   This power supply should have an output voltage of 10V ‐15V DC and be able to  provide as much as 5 Amp ...
Aalborg Universitet Flywheel Energy Storage System
Aalborg Universitet Flywheel Energy Storage System

... currently a much more cost-effective choice for customers, expected to replace the traditional vehicles and have a considerable numbers of users in the future. Therefore, providing an acceptable surroundings and necessary ancillary services of PHEV fleets is a critical issue of next generation smart ...
Active Harmonic Filtering Solutions Catalogue
Active Harmonic Filtering Solutions Catalogue

Introduction to Power Management
Introduction to Power Management

... Which control mode to use for various applications? – COT  cheap and easy, always stable but variable frequency & ripple – Voltage mode  most common in Buck, cheap and easy low component count – Current mode  most common for CCM in Boost, Buck-Boost, SEPIC, Flyback, very good performance but need ...
Pdf Format - Journal of Chemical and Pharmaceutical Sciences
Pdf Format - Journal of Chemical and Pharmaceutical Sciences

... One of the mail reliability issues of PV systems is the mismatch values between its expected and actual power outputs. This problem can be called PV mismatch. It can have many sources, and the one addressed in this paper is the partial shading of PV modules. Many authors have proposed ideas to mitig ...
RF Amplifier Output Voltage, Current, Power
RF Amplifier Output Voltage, Current, Power

... How much output voltage, current and power can RF amplifiers provide? This question is often asked by novice test engineers as well as seasoned RF professionals. Depending on the application, there is often an underlying desire to maximize one of the three parameters; power, voltage or current. Whil ...
Power Factor Correction
Power Factor Correction

...  DOE energy star requires PF >0.7 for energy star rating of LED light sources  Europe EN61000-3-2 requires power factor to meet harmonic requirements for light sources above 25W These standards provide a baseline requirements!  Market requirements for LED bulbs and fixtures are driving PF >0.9 fo ...
Payton Planar Magnetics
Payton Planar Magnetics

... R&D Engineering, Payton Group International Compact and high efficient power conversion is critical to the continued profitable growth and miniaturization of the telecommunication, computer, vehicle and other host industrial and military systems. The creation of any high-efficiency power supply, and ...
45A Dual-ESC Manual
45A Dual-ESC Manual

... 7. BEC output voltage 5V, output rated current 2.5A, the maximum current output of 3A, the situation can be selected according servo, pay attention to no more than the maximum current output, when the two groups in parallel, the rated current output of 5A, the maximum output current 6A. The first ti ...
RF2174 0
RF2174 0

... vias to the PCB ground plane, and not connected with the output ground to form a so called “local ground plane” on the top layer of the PCB. The output is brought out through the wide output pad, and forms the RF output signal path. The amplifier operates in near Class C bias mode. The final stage i ...
Adaptive switching frequency buck DC–DC converter with high
Adaptive switching frequency buck DC–DC converter with high

... and PFM controllersŒ6 is presented in a single chip. However, the efficiency declines when the load is at a medium range. To solve this problem, a multi-mode converter including three modesŒ7 is introduced, whereas it increases the complexity of the circuit configuration. All converters mentioned ...
doc00000 - Finite Element Method Magnetics
doc00000 - Finite Element Method Magnetics

Aalborg Universitet with measurement data
Aalborg Universitet with measurement data

... non-linear switching devices (i.e. diodes, thyristors and transistors). During normal operation they produce nonsinusoidal periodic voltages and currents, thereby producing harmonics and characteristic for power converters interharmonics [11]. Power electronic devices are widely used in WTs nowadays ...
power quality guidebook
power quality guidebook

... Service and Support Selecting the proper power quality solution for your application can be tricky. Experienced and dedicated sales representatives, along with award-winning online tools, help you make the right choice, every time. Representatives are available around the world for stock and support ...
L-20(NKD)
L-20(NKD)

... As the lagging power factor decreases from 1.0 to 0.5, with φ increasing from 0° to + 60° , the reading of the first wattmeter, W1 decreases from a certain positive value to zero (0). But the reading of the second wattmeter, W2 increases from a certain positive value to positive maximum, as the lagg ...
Cooper_Silicon_Mechanics_110508
Cooper_Silicon_Mechanics_110508

... could be as high as 0.1 to 0.13 W/cm2, or higher by a factor of 7.5 to 10 (~2 W/ladder for SiD VTX Layers 2-5). • Initial calculations of heat removal via dry air flow have been made assuming 0.13 W/cm2 and geometries similar to those proposed for the VTX barrel of SiD, CLIC-ILD, and CLIC-SiD. ...
Non-insulated SCR / Triac control circuits
Non-insulated SCR / Triac control circuits

... SCR and Triac triggering circuit with a positive power supply With positive power supplies, the gate current can be only sourced from the control circuit to the gate. Such a topology is adapted for SCRs control. For Triacs, the devices are then triggered in quadrants Q1 and Q4. Such an operation is ...
Aalborg Universitet system
Aalborg Universitet system

... or subsystems on the system stability is usually hidden in the state matrix. In [12], the Component Connection Method (CCM) that takes advantage of matrix algebra and sparsity is introduced for the stability analysis of the High-Voltage DC (HVDC) systems. Unlike the general state-space models, the C ...
QUICKTRONIC® PROStart® T5HO 0.80BF Universal Ballast
QUICKTRONIC® PROStart® T5HO 0.80BF Universal Ballast

... models in inventory by half. The QUICKSTEP system has two AC line inputs in addition to the neutral wire. These AC line inputs must be connected to the same phase of the line voltage. The two line inputs can be configured to provide a bi-level light output system by wiring the system with two switch ...
Modeling and analysis of harmonic resonance in a power
Modeling and analysis of harmonic resonance in a power

... or subsystems on the system stability is usually hidden in the state matrix. In [12], the Component Connection Method (CCM) that takes advantage of matrix algebra and sparsity is introduced for the stability analysis of the High-Voltage DC (HVDC) systems. Unlike the general state-space models, the C ...
PPT file format 2.1M
PPT file format 2.1M

... Copper Block ...
Power Efficiency in OS X Technology Overview
Power Efficiency in OS X Technology Overview

... a nonlinear way, so running a CPU at double the clock speed can require significantly more than double the power. Because of these issues, CPU vendors shifted their focus from cranking up clock speed to putting multiple processor cores into a single CPU in order to use less total energy per unit of ...
< 1 ... 246 247 248 249 250 251 252 253 254 ... 561 >

Electric power system



An electric power system is a network of electrical components used to supply, transmit and use electric power. An example of an electric power system is the network that supplies a region's homes and industry with power—for sizable regions, this power system is known as the grid and can be broadly divided into the generators that supply the power, the transmission system that carries the power from the generating centres to the load centres and the distribution system that feeds the power to nearby homes and industries. Smaller power systems are also found in industry, hospitals, commercial buildings and homes. The majority of these systems rely upon three-phase AC power—the standard for large-scale power transmission and distribution across the modern world. Specialised power systems that do not always rely upon three-phase AC power are found in aircraft, electric rail systems, ocean liners and automobiles.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report