• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
product catalog - Hughey and Phillips
product catalog - Hughey and Phillips

... Hughey & Phillips obstruction lights have a sturdy construction, are built to last and fulfill both national and international specifications. All our lights are completely non-corroding, low-maintenance lights. Our product portfolio includes state-of-the-art LED low and medium intensity obstruction ...
EEE-PP-008 - 5259
EEE-PP-008 - 5259

... Photovoltaic (PV) generation systems are widely employed in transformer less inverters, in order to achieve the benefits of high efficiency and low cost. Safety requirements of leakage currents are met by proposing the various transformer less inverter topologies. In this paper, three transformer le ...
D.J. Perreault and V. Caliskan, “Automotive Power Generation and Control,” IEEE Transactions on Power Electronics , Vol. 19, No. 3, May 2004, pp. 618-630.
D.J. Perreault and V. Caliskan, “Automotive Power Generation and Control,” IEEE Transactions on Power Electronics , Vol. 19, No. 3, May 2004, pp. 618-630.

Equipment Grounding Conductor
Equipment Grounding Conductor

... Observing proper grounding and bonding processes and employing reliable materials are essential considerations that contribute to the safety of personnel and equipment over the lifetime of an electrical system. Properly following the general requirements for grounding and bonding articulated in Sect ...
download 1
download 1

... every practical safety precaution, exercise extreme caution at all times when you expose circuits and components, and when you operate, maintain, or service this equipment. ...
Grounding and Bonding CEC-10 [rev-9]
Grounding and Bonding CEC-10 [rev-9]

... requirements of Rule 10-812 and it may be necessary to use a 4-conductor cable. Elimination of Stray Voltage in Areas Housing Livestock Where stray voltages are severe enough to present a problem in facilities housing livestock, neutral to earth reactors (commonly known as "tingle voltage filters) a ...
SCADAPack ES Hardware Manual
SCADAPack ES Hardware Manual

PIC120.241C, PIC120.242C
PIC120.241C, PIC120.242C

... If damage or malfunction should occur during installation or operation, immediately turn power off and send unit to the factory for inspection. Mount the unit on a DIN-rail so that the input terminals are located on the bottom of the unit. This device is designed for convection cooling and does not ...
Cascaded Converters with Gate-Commutated Thyristors
Cascaded Converters with Gate-Commutated Thyristors

HF2614291439
HF2614291439

OSI Physical Layer
OSI Physical Layer

Huawei IP Products - Huawei Summit 2013
Huawei IP Products - Huawei Summit 2013

... • Built-in IPSec encryption acceleration, no service card is required ...
IF 1545 Revision 1
IF 1545 Revision 1

... precaution, exercise extreme caution at all times when you expose circuits and components, and when you operate, maintain, or service this equipment. ...
Linux+ Guide to Linux Certification
Linux+ Guide to Linux Certification

... • Promote worldwide use of 802.11 WLANs ...
T-VER-E50B2 - Onset Computer Corporation
T-VER-E50B2 - Onset Computer Corporation

... environment must control conductive pollution and the possibility of condensation or high humidity. Consider the enclosure, the correct use of ventilation, thermal properties of the equipment, and the relationship with the environment. Installation category: CAT II or CAT III Provide a disconnect de ...
FR3610401047
FR3610401047

... The conventional power electronic converters used in the micro generator based energy harvesting applications has two stages: a diode bridge rectifier and a dc-dc converter. But it is less efficient and can’t be used for electromagnetic micro generators, as the diode bridge rectification is not norm ...
CMOS drive DIL Reed Relays
CMOS drive DIL Reed Relays

... equivalent to the Series 101 CMOS drive, Single-In-Line types, but pin compatible with standard DIL relays. The range features very high coil resistances, the 5 volt dry devices may be driven directly from 74HC or 74HCT logic without the need for additional drivers. Naturally, high resistance 12 and ...
PDF
PDF

... The Cisco Aironet 350 Series Bridge is the suggested replacement for the Cisco Aironet 340 Series Bridge. The Cisco Aironet 350 Series Bridge has many superior features, including inline power and plenum ratability. Please note, however, that the Cisco IOS® Software-compatible Spanning Tree Protocol ...
Liebert NXL System Control Cabinet , SCCi
Liebert NXL System Control Cabinet , SCCi

... chercher de l’aide en cas d’accident. NOTE Materials sold hereunder cannot be used in the patient vicinity (e.g., use where UL, cUL or IEC 60601-1 is required). Medical applications, such as invasive procedures and electrical life support equipment, are subject to additional terms and conditions. ...
SureHeat® MAX Air Heater Operating Manual
SureHeat® MAX Air Heater Operating Manual

... of airflow protection if wired properly. 4. If using other form of controls you must always have sufficient airflow through the heater before applying power. Otherwise element will overheat very quickly, and burn out. It is highly recommended that the S1 thermocouple supplied with the heater be used ...
Power Supply Module 230 V MDP 102-1 1 Overview
Power Supply Module 230 V MDP 102-1 1 Overview

6LoWPAN demystified
6LoWPAN demystified

... Figure 1. An example of an IPv6 network with a 6LoWPAN mesh network Because edge routers forward datagrams at ...
GA-H110M-DS2 GA-H110M
GA-H110M-DS2 GA-H110M

... The motherboard contains numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the user's manual and follow these procedures: •• Prior to installation, make sure the chassis is suitable for th ...
Contract drawings and documents
Contract drawings and documents

... Remote tap position indicator mounted on remote control panel shall show accurately same tap position as indicated by local tap position indicator on on-load tap changer. The remote indication can be by means of a digital indicator. Transmitter switch in the driving gear shall be make before break t ...
ppt - LoriMCollier
ppt - LoriMCollier

... Guide to 801: ...
< 1 ... 67 68 69 70 71 72 73 74 75 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report