Download product catalog - Hughey and Phillips

Document related concepts

Audio power wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Three-phase electric power wikipedia , lookup

War of the currents wikipedia , lookup

Buck converter wikipedia , lookup

Power over Ethernet wikipedia , lookup

Electric power system wikipedia , lookup

Electrical ballast wikipedia , lookup

Power engineering wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Distribution management system wikipedia , lookup

Opto-isolator wikipedia , lookup

Voltage optimisation wikipedia , lookup

Mains electricity wikipedia , lookup

Electrification wikipedia , lookup

Alternating current wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Rectiverter wikipedia , lookup

LED lamp wikipedia , lookup

History of electric power transmission wikipedia , lookup

Street light wikipedia , lookup

Transcript
Catalog No. 1201
Ob st r u c t i o n L i g h t i n g
PRODUCT
CATALOG
HUGHEYANDPHILLIPS.COM
Lighting AT GREAT HEIGHTS For 75 Years.
Broadcast
|
Telecommunications
|
Wind Turbines
|
Tall Structures
|
Utilities
Hughey & Phillips Obstruction Lighting Shines Brighter.
About Hughey & Phillips
For more than 75 years, Hughey & Phillips, LLC products have found their place atop some
of the world’s most monumental architectural achievements. At Hughey & Phillips, we make
a complete line of cost-effective obstruction lighting and control solutions that are proven to
be highly efficient and reliable with improved maintainability and a longer operational life.
• Cost-effective obstruction
As either stand-alone fixtures or as part of an integrated system, Hughey & Phillips’ low,
medium, and high intensity lighting solutions provide illumination for radio and television
transmission towers, communications and microwave antennas, wind turbines, grain
elevators, buildings, smokestacks, bridges, and other obstructions to aerial navigation as
specified by the FAA, FCC, ICAO, DGAC of Mexico and Transport Canada.
lighting and controls solutions
• Highly efficient products
save energy and reduce
maintainability costs
Advancements in LED-based obstruction lighting technologies have resulted in lighting
fixtures that extend our beacon service life up to 10 times longer than incandescent bulbs
with lower power consumption. Additionally, our strobes use unique parabolic reflectors/
linear strobetubes optics and integrated flashhead blocking strips to minimize ground scatter
light for more community friendly lighting systems.
• Stand-alone fixtures or
integrated systems
available for low, medium
and high intensity
lighting products
• Longer operational life keep
structures illuminated and
replacements costs low
Hughey & Phillips is a global
leader in the design and
manufacturing of obstruction
lighting technology. The
company offers complete
solutions comprised of power
and lighting systems designed
APPLICATIONS
All low intensity lights are available as single or double lights. The low intensity and medium
intensity lighting are used to mark air traffic obstructions. Different lights are used for different
specific applications, all-round illuminated obstruction lights with a light intensity of 10 cd
(Candela) or 32 cd, flashing medium intensity lights in red or white with 2,000 cd or 20,000
cd and even high-intensity lights in white with up to 270,000 cd. In the United States the
use of specific lighting is defined in the FAA Advisory Circular 70/7460-1 on the marking of
obstructions. The ICAO (International Civil Aviation Organization) or Local Aviation Authority
governs for national regulations.
Versatile Obstruction lighting solutions for any Industry.
Hughey & Phillips engineers and designs a complete line of low, medium and high intensity
lighting technology solutions that provide illumination for a wide range of industries:
•
•
•
•
•
Broadcast
Telecommunications
Wind Turbines
Tall Structures
Utilities
Whether you need to illuminate radio, television or communication towers; wind turbines;
buildings; smokestacks; bridges; or other obstructions to aerial navigation, Hughey & Phillips
provides innovative lighting technology solutions.
and manufactured in the USA.
We have a full engineering staff providing complete support and design in optical, electrical
and mechanical disciplines to customize any of our products to fit your application’s unique
needs. To learn more, visit www.hugheyandphillips.com
Ordering Information
Designed for a wide range of obstruction lighting applications, Hughey &
Phillips’ broad line of incandescent, xenon and LED-based lighting fixtures
and control solutions provide long-life operation and highly reliable
performance. Contact a Hughey & Phillips representative today by visiting
www.hugheyandphillips.com or by calling toll-free 877-285-4466.
Lighting Up the World’s Towering Achievements .
PRODUCT OVERVIEW
Hughey & Phillips obstruction lights have a sturdy construction, are built to last and fulfill both national
and international specifications. All our lights are completely non-corroding, low-maintenance lights.
Our product portfolio includes state-of-the-art LED low and medium intensity obstruction lights as well
as lights with a conventional light-source ranging from simple incandescent obstruction lights to highintensity strobe lights for special applications.
Our power-saving LED lights guarantee a life span that is several times longer than conventionally
equipped lights. This is achieved by a redundant circuit design and reduction of power consumption by
over 90% of the normal usage of incandescent lights. Infrared (IR) LED systems are also available.
MAKING THE WORLD
BRIGHTER.
Tower & Obstruction Lighting Guide
For over 75 years, Hughey &
The Hughey & Phillips tower and obstruction lighting guide provides the latest FAA, FCC, Transport
Canada & ICAO tower and obstruction products for lighting buildings, towers, smokestacks, grain
elevators or other structures, either temporary or permanent, which might present obstructions to air
navigation. References will be made in this guide to FAA, FCC, Transport Canada & ICAO requirements.
The specifications and guidelines referred to are the following:
• FAA Advisory Circular No. 150/5345-43
Specification for Obstruction Lighting Equipment
• FAA Advisory Circular AC 70/7460-1K
Obstruction Marking and Lighting
• FCC Rules and Regulations Part 17
Construction, Marking and Lighting of Antenna Structure
• ICAO Aerodromes Annex 14
International Standards and Recommended Practices
• Transport Canada CAR 621.19
• Certified by the Secretary of Communications & Transport of Mexico
Copies of these documents are available from the issuing agency or by contacting Hughey & Phillips.
All Hughey & Phillips products where applicable are qualified to FAA specifications AC150/5345-43. In
order to maintain an FAA listing, Hughey & Phillips must undergo rigid quality review twice yearly by an
independent test laboratory.
low
intensity
diagrams
4
MEDIUM
intensity
40
accessories
9
HIGH
intensity
52
22
lighting
systems
Phillips obstruction lighting
has earned a reputation for
quality, dependability and
innovation the world over.
In fact, we’ve illuminated
some of the globe’s highest
structures on six continents.
international
products
63
26
cables
faa standards
34
76
Low
intensity
LOW INTENSITY
FAA Type: L-810 Steady Burn Obstruction Light
HORIZON™
L-810 LED OBSTRUCTION LIGHT
APPLICATION
The Hughey & Phillips L-810 Obstruction Light provides an LED based solution to the FAA
L-810 style of steady burning lights. The L-810 LED is currently available in both single and
double configurations operating at 120V, 240V, 277VAC and also in a range of 9-48 VDC.
Both configurations are available as original equipment or as a direct replacement to the
existing socket/lamp/lens on H&P L-810 Incandescent OB2x Series obstruction lights.
FAA Type: L-810 Steady Burn Obstruction Light
ICAO Type: Low Intensity Type B Obstacle Light
ETL Certified: FAA AC 150 45-43F
Compliant to: ICAO Annex 14, CAR 621.19, MIL-C-7989
Features:
•
•
•
•
•
•
•
•
•
•
LED based obstruction lights last over 15 times longer than an incandescent light
Approximately 94% less power than 116 Watt standard incandescent lamp
4 Watt Power Consumption (AC version) / 3.4 Watts (DC Version)
Available in both side and bottom conduit hubs at ¾” and 1” NPT
Weather resistant lamp assembly & housing
Self-contained wiring compartment on double units eliminates additional boxes
Operates as a steady burn or flashing light
Resistant to shock and vibration
Direct replacement for existing incandescent fixtures
5 Year Warranty
Photometric Specifications
Beam Spread: 360° Horizontal, 10° Minimum Vertical
Effective Intensity: > 32 Candela
Mechanical Specifications
Base Material: Cast Aluminum with aviation red powder coat
Lens: Heat resistant clear glass
Single: 8” x 5.5” x 5.5” (H x W x L), 2 lbs.
Double: 8” x 5.5” x 11.5” (H x W x L), 6 lbs.
Environmental Specifications
Temperature: -55°C to +55°C (-67°F to 130°F)
Humidity: 95% Relative Humidity
Miscellaneous: Will withstand exposure to wind-blown rain
from any direction, salt-laden atmosphere and indspeeds of
240 kph (150 mph).
6
HUGHEYANDPHILLIPS.COM
Part Number
45-1000-001
45-1001-001
45-1002-001
45-1003-001
45-1004-001
45-1005-001
45-1006-001
45-1007-001
45-1008-001
45-1009-001
45-1010-001
45-1011-001
45-1012-001
45-1013-001
45-1014-001
45-1015-001
Description
L-810 LED 95-277VAC SGL BOT HUB 3/4
L-810 LED 95-277VAC SGL BOT HUB 1
L-810 LED 95-277VAC SGL SIDE HUB 3/4
L-810 LED 95-277VAC SGL SIDE HUB 1
L-810 LED 95-277VAC DBL BOT HUB 3/4
L-810 LED 95-277VAC DBL BOT HUB 1
L-810 LED 95-277VAC DBL SIDE HUB 3/4
L-810 LED 95-277VAC DBL SIDE HUB 1
L-810 LED 9-48VDC SGL BOT HUB 3/4
L-810 LED 9-48VDC SGL BOT HUB 1
L-810 LED 9-48VDC SGL SIDE HUB 3/4
L-810 LED 9-48VDC SGL SIDE HUB 1
L-810 LED 9-48VDC DBL BOT HUB 3/4
L-810 LED 9-48VDC DBL BOT HUB 1
L-810 LED 9-48VDC DBL SIDE HUB 3/4
L-810 LED 9-48VDC DBL SIDE HUB 1
Spare Parts
45-0001-001
45-0002-001
A6A0008AG
B6A0008AA
Description
L-810 LIGHT MODULE 95-277VAC
L-810 LIGHT MODULE 9-48VDC
NEOPRENE GASKET
LENS HOLDER w/7” CHAIN
LOW INTENSITY
FAA Type: L-810 Steady Burn Obstruction Light
INCANDESCENT OBSTRUCTION LIGHTS
APPLICATION
The OB20 and OB21 single obstruction lights are equipped with a screw base lamp
receptacle. The fixtures are cast aluminum and utilize flange type red fresnel lenses. The
fixtures are available with either bottom entrance (OB20) or side entrance (OB21) for 3/4” or
1” conduit fittings. The fixtures are suitable for use with 120 or 230 VAC lamps.
Certified to: FAA AC 150/5345-43F
Compliant to: Transport Canada CAR 621.19
ICAO Annex 14
USAF AFMAN 32-1076
Models
OB20A31 OB20A41
OB21A31
OB21A41
3/4” bottom conduit entrance
1” bottom conduit entrance
3/4” side conduit entrance
1” side conduit entrance
Photometric Specifications
Single Obstruction Light
Beam Spread: 360° Horizontal, 10° Minimum Vertical
Effective Intensity: >32 Candela
Dimensions: 230mm H x 140mm W x 140mm L
(9”H x 5.5”W x 5.5”L)
Weight: 1.8 Kg (4 Pounds)
Mechanical Specifications
Base Material: Cast aluminum with aviation red powder coat
Lens: Heat resistant glass, red.
Environmental Specifications
Temperature: -55°C to +55°C (-67°F to 130°F)
Humidity: 95% Relative Humidity
Miscellaneous: Will withstand exposure to wind-blown rain
from any direction, salt-laden atmosphere and indspeeds of
240 kph (150 mph).
Spare Parts and Accessories
LH116120GE
Lamp 120 VAC, 116 Watts
FL02B02810
Red Fresnel Lens
XLCB4S200
Lamp Receptacle
A6A0008AGNeoprene Gasket
LH116230 DT
Lamp 120 VAC, 116 Watts
B6A0008AA
Lens Holder w/7” Chain
877.285.4466 Toll Free
7
LOW INTENSITY
FAA Type: L-810 Steady Burn Obstruction Light
DOUBLE INCANDESCENT OBSTRUCTION LIGHTS
APPLICATION
The OB22 and OB24 double obstruction lights are equipped with two screw base lamp
receptacles. The fixtures are cast aluminum and utilize flange type red fresnel lenses. The
fixtures are available with either side entrance or bottom entrance for 3/4” or 1” conduit
fittings. The fixtures are suitable for use with 120 and 230 VAC lamps.
Models
OB22A31 OB22A41
OB24A31
OB24A41
3/4” bottom conduit entrance
1” bottom conduit entrance
3/4” side conduit entrance
1” side conduit entrance
Double Obstruction Lights With Automatic Transfer Relay
In many circumstances it is highly desirable, or required, to employ a lamp transfer relay
with a double obstruction light. Upon failure of the first lamp, the relay will transfer power
to the second, or standby lamp. The relay is mounted within the fixture base. This relay
is of the single pole, single throw, normally closed type. Only one lamp in the double
obstruction light is energized when a transfer relay is used. The fixtures are suitable for use
with 120 and 230 VAC lamps.
Models
OB22A41TM1
OB24A41TM1
3/4” or 1” bottom conduit entrance
3/4” or 1” side conduit entrance
Photometric Specifications
Double Obstruction Light
Beam Spread: 360° Horizontal, 3° Minimum Vertical
Effective Intensity: > 32 Candela
Dimensions: 235mm H x 140mm W x 292mm L
(9.25”H x 5.5”W x 11.5”L)
Weight: 3.75 Kg (8.25 Pounds)
Mechanical Specifications
Base Material: Cast aluminum with aviation orange,
powdercoat paint finish
Lens: Heat resistant glass, red
Environmental Specifications
Temperature: -55°C to +55°C (-67°F to 130°F)
Humidity: 95% Relative Humidity
Miscellaneous: Will withstand exposure to wind-blown rain
from any direction, salt-laden atmosphere and windspeeds
of 240 kph (150 mph)
Spare Parts and Accessories
LH116120GE
Lamp 120 VAC, 116 Watts
FL02B02810
Red Fresnel Lens
XLCB4S200
Lamp Receptacle
A6A0008AGNeoprene Gasket
LH116230 DT
Lamp 120 VAC, 116 Watts
6A0013SK3
Transfer Relay Assembly
B6A0008AA
Lens Holder w/7” Chain
8
HUGHEYANDPHILLIPS.COM
medium
intensity
MEDIUM INTENSITY
FAA Type: L-864, L-865, and L-866 Medium Intensity Lighting
HORIZON™ Series
LED strobe system Description
The Horizon™ Dual Medium Intensity LED Strobe System provides daytime white and
nighttime red lights in one unit. Its self-contained power supply, with available GPS sync and
day/night sensor, simplifies wiring but also accepts external signals if desired. Advanced
features include advanced LED modules, cutting edge optics, individual LED monitoring/
bypass, and active lightning protection (patent pending). The unit also monitors the system
and provides a NO or NC alarm contact upon any system failure.
Application
Medium intensity obstruction lighting systems are typically used on structures between 150’
(45m) and 500’ (150m) above ground level to provide aviation safety. The use of a medium
intensity white strobe during the daytime typically eliminates the need to paint the structure
with aviation orange and white stripes. The use of a red flashing beacon at night provides
a “community friendly” light. Hughey & Phillips medium intensity obstruction lights are
designed for lighting tall structures such as communication, television and radio towers, wind
turbines, smokestacks, cooling towers, tall buildings, catenary river crossings and bridges.
FAA Type: L864, L865 or L-864/865 Medium Intensity Lighting
ICAO Type: Type A/B Medium Intensity Obstacle Light
ETL Certified: FAA Advisory Circular 150/5345-43
Compliant for use with: ICAO Annex 14, MIL-C-7989
DGAC of Mexico, CAR 621.19
Photometric Specifications
Mechanical
Day Mode (White): 20,000 candela ± 25%
Night Mode (White or Red): 2,000 candela ± 25%
Beam Spread: 3° minimum
Horizontal Coverage: 360°, omni-directional
Flash Rate: 40 FPM Day & White Night
24 FPM Night Red
Weight, Flashhead: 8 kg (17 lbs)
Flashhead Lens Material: High Temp/UV Resistant Acrylic
Environmental Specifications
Temperature: -40°C to +55°C (-40°F to 130°F)
Humidity: 95% Relative Humidity
Miscellaneous: Will withstand exposure to wind-blown rain
from any direction, salt-laden atmosphere and windspeeds of
240 kph (150 mph)
10
HUGHEYANDPHILLIPS.COM
Electrical
Input Voltages: 120, 230/240, 277, 480 VAC
Input Frequencies: 50 or 60 Hz
Power Consumption, Day: 25 Watts
Power Consumption, Night: 15 Watts
MEDIUM INTENSITY
FAA Type: L-864, L-865, and L-866 Medium Intensity Lighting
HORIZON™ Series
FeaturesBenefits
Original Equipment Manufacturer
Designed, engineered and manufactured by Hughey & Phillips
One source for fixtures and complete lighting systems
Single Flashhead constructionCompact design for dual (red/white) operation
Failsafe Redundancy
Automatic switching for nighttime redundancy of dual systems
GPS Synchronization AvailableBuilt In GPS SYNC module
IR Capability Available
Viewable with NVG Goggles
Wiring Compatibility
Existing wiring can be used for retrofit applications
Environmentally sealed connector
Fewest number of control wiring on the market
Interchangeable LED Modules
Single screw access
Built-in Safety interlock switch
Fully field serviceable unit
Cutting Edge Optics designH&P exclusively designed ‘Eklipse’ optics package
Community friendly lighting system
Lightest Flashhead
17 lbs
Ease of handling and installation
Universal InputOperating voltage of 95-277 VAC, 50/60Hz
These specifications are subject to change.
dimensions
Part Number
Description
50-0002-001
50-0003-001
50-0004-001
50-0005-001
FAA Type L-864, 95-277VAC 50/60Hz
FAA Type L-865, 95-277VAC 50/60Hz
FAA Type L-866, 95-277VAC, 50/60Hz
FAA Type L-864/865, 95-277VAC 50/60Hz
877.285.4466 Toll Free
11
MEDIUM INTENSITY
FAA Type: L-864 Medium Intensity Lighting
MODEL KG 114 300 mm Beacon
For Airport and Obstruction Lighting
Application
Model KG 114 300mm Beacon is approved as a marker light for obstructions to air
navigation such as television, radio, microwave and transmission line towers, bridges,
water tanks, stacks and other tall structures as specified by the FAA. Model KG 114 300mm
Beacon is in full compliance with FAA Beacon requirements for marking of obstructions to
air navigation.
Meets ICAO Requirements & Transport Canada
Features
Constructed of heavy aluminum casting, Model KG 114 300mm Beacon is completely
weatherproof, and features:
• Concave base: with drain port at lowest point prevents accumulation of moisture from
condensation.
• Hinged center frame: hinged at the center between the upper and lower lens assemblies
to provide ready access for inspection and lamp replacement. The hinge rings, neoprene
gasket, butterfly locking clamp, maintain a weatherproof center seal.
• Color filter supports: with flexible fins provide heat insulation and cushioning, thus
eliminating color filter breakage from expansion and construction.
• Equipped with stainless hardware.
• IR compatible with enhanced flight vision systems that use IR energy emissions for
imaging, including NVG goggles.
Part No.
Description
FAA Designation
Weight
KG 114 F0001
LH620120GE
LH700230HDT
300mm Beacon with Red Lens
620 Watts, 120 V Lamp
700 Watts, 230 V Lamp
L864
73 lbs
12
HUGHEYANDPHILLIPS.COM
MEDIUM INTENSITY
FAA Type: L-864 Medium Intensity Lighting
MODEL KG 114 300 mm Beacon
For Airport and Obstruction Lighting
Descriptive Data
Model KG 114 300mm Beacon is designed for service under all climatic conditions. Frame
and hardware are constructed of non-ferrous materials. All the glassware is heat-resistant
meeting FAA and Military Specifications.
The Optical System consists of four red, heat-resistant lenses, designed to provide a definite
beam through 360O horizontally. The two lamp receptacles are mounted to properly position
the two 620 or 700 watt Mogul Pre-focus Beacon lamps, thus providing correct beam
distribution in accordance with FAA and Military specifications.
A Three Terminal Connecting Block is mounted in the base allowing each lamp to be
independently fed and monitored. Internal wiring is heat-resistant insulated flexible wire,
terminates at the connecting block. Unless otherwise ordered, beacons are furnished with
five feet of #12-3 Conductor Neoprene Cable, entering the base through a 1” Watertight
Connector. Conduit may be used by removing the Watertight Connector and disconnecting
the External Cable.
Neoprene Gaskets are designed for long life under extreme temperatures. Upper Gasket
Retainer, and Lower Gasket Retainer assure Weatherproof protection between lenses.
877.285.4466 Toll Free
13
MEDIUM INTENSITY
FAA Type: L-865 and L-866 Medium Intensity Lighting
FlashGuard® 2000
FlashGuard® 2000 System Description
The FlashGuard 2000 Medium Intensity White Lighting System combines a daytime white
strobe light and a nighttime white flashing light into a single flashhead. The system is also
available as a red flashhead which can be used at night in place of red incandescent lighting,
for much longer light source life. The flashhead is powered and controlled by a power supply
that can be mounted remotely at the base of the structure. The power supply constantly
monitors the operation of the system, and provides alarm contact closure upon any failure.
The system automatically switches between day, twilight, and night intensities by the use of
a calibrated photocell. FlashGuard® 2000 flashheads incorporate a light blocking strip that
minimizes ground scatter light, resulting in a community friendly lighting system.
APPLICATION
Medium Intensity obstruction lighting systems are typically used on structures between 150’
(45M) and 500’ (150M) above ground level to provide aviation safety. The use of a medium
intensity white strobe during the daytime typically eliminates the need to paint the structure
with aviation orange and white stripes. The use of a white flashing strobe at night provides an
‘eye catching’ light for low flying aviators. Hughey & Phillips’ medium intensity obstruction
lights are designed for lighting tall structures such as communication, television and radio
towers, chimneys, cooling towers, tall buildings, catenary river crossings and bridges. This
light is compatible with Enhanced Flight Vision Systems that use IR energy emissions for
imaging, including NVG goggles.
FAA Type: L-864, L-865 & L-866 Medium Intensity Lighting
ICAO Type: Medium Intensity Obstacle Light
Applicable Specifications:
Conforms to: FAA Advisory Circular AC 70/7460-1
FAA Advisory Circular AC 150/5345-43E | ICAO Annex 14
Transport Canada TP 382E | DGAC of Mexico 150/5345-43E
Electrical Specifications
Environmental Specifications
AC Input Power 120 VAC +/- 10%, 60 Hz, 1 phase standard; 195 watts day operation,
60 watts night operation
DC Input Power 24 VDC +/- 10%;120 watts day operation, 45 watts night operation
Power Options
240, 480 VAC +/- 10%; 60 Hz or 240, 480 VAC +/- 10%, 50 Hz
TransientTransient protection is provided by:
Protection
• Company proprietary circuits which incorporate
series resistors and zener diodes on all signal lines
• 5 kilovolt rated transformer, primary and secondary line to ground
insulation
• Rectifier diode network protection by varistors
System StatusTwo neon lamps and four LEDs indicate system and
Indicators subsystem operating status.
SafetyThe flashhead and power supply are both equipped with interlocks
so that opening either unit interrupts the capacitor charging circuit
and discharges the high voltage energy storage capacitors in the
power supply to less than 50 volts within 30 seconds.
Temperature
-67°F (-55°C) to + 130°F (+55°C) per MIL-STD-810
Humidity
95% relative humidity per MIL-STD-810
Wind
Wind speeds up to 150 mph (67 m/sec)
Wind Loading 72 lbs (32 kg) at 150 mpg (67 m/sec) Surface area is 1.282 (0.12m2)
Wind Blown
Rain
Exposure to wind blown rain from any direction per MIL-STD-810
Salt Fog
Exposure to salt-laden atmosphere per MIL-STD-810
optical performance specifications
Mode
Beam Spread1
Peak
Flash
Flash/Rate
Duration3
(degrees)Intensity2
Horizontal Vertical (candelas)
(flashes/minute) (milliseconds)
Day/Twilight 360°
3° min
15,000 min
25,000 max
Night
360°
3° min
1,500 min
2,500 max
Notes:
1. The lower edge of the vertical beam spread lies between –1.5° and -0.5° with respect to the horizon.
2. Flashlamp light out meets the FAA minimum requirements of 15,000 candelas day/twilight and 1,500 candelas night for a period of not less than one year.
3. When the effective flash duration is generated with a group of short flashes, the flash rate is not less than 30 per second.
14
HUGHEYANDPHILLIPS.COM
40-L-865
<10
60-L-866
40 for L-865
60 for L-866
100 to 250
MEDIUM INTENSITY
FAA Type: L-865 and L-866 Medium Intensity Lighting
FlashGuard® 2000
mechanical dimensions
ss-175 power supply
15.50 (394)
Clearance
18.50 (470)
16.19 (411)
16.26
(412)
10.50 (267)
8.63
(219)
ss 120
photocontrol
w/receptacle
17.25
(438)
5.00
(127)
5.00
(127)
0.44 (11) mounting hole
4 places
6.00
(152)
3.38
(86)
3/4” cable connector
3.50
(89)
ss-120 photocontrol is
removable for indoor installation
Weight: 53 pounds
(24 kilograms)
ss-176 flashhead
5.00 (127)
clearance
90O
120O
flashhead globe
lifts for access
to flashtubes
focal plane
3/4” cable
connector
16.50 (419)
15.00 (381)
weight: 22 pounds
(10 kilograms)
15.92 (404)
120O
90O
3.88
(98)
4.80
(122)
90O
mounting slot
0.69 x 0.81
(17 x 21)
6 places on
13.25 (337)
bolt circle
bottom of flashhead
for mounting with
3 or 4 fasteners
Dimensions are in inches (millimeters)
877.285.4466 Toll Free
15
MEDIUM INTENSITY
FAA Type: L-864, L-865, or L-866 Medium Intensity Lighting
FlashGuard® 2000B
FlashGuard® 2000B System Description
The FlashGuard 2000B Medium Intensity White Lighting System combines a daytime white
strobe light and a nighttime white flashing light into a single flashhead. The system is also
available as a red flashhead which can be used at night in place of red incandescent lighting,
for much longer light source life. The flashhead is powered and controlled by a power supply
that can be mounted remotely at the base of the structure. The power supply constantly
monitors the operation of the system, and provides alarm contact closure upon any failure.
The system automatically switches between day, twilight, and night intensities by the use of
a calibrated photocell. FlashGuard® 2000B flashheads incorporate a light blocking strip that
minimizes ground scatter light, resulting in a community friendly lighting system.
APPLICATION
White FG2000B
Red FG2009B
Medium Intensity obstruction lighting systems are typically used on structures between 150’
(45M) and 500’ (150M) above ground level to provide aviation safety. The use of a medium
intensity white strobe during the daytime typically eliminates the need to paint the structure
with aviation orange and white stripes. The use of a white flashing strobe at night provides an
‘eye catching’ light for low flying aviators. Hughey & Phillips’ medium intensity obstruction
lights are designed for lighting tall structures such as communication, television and radio
towers, chimneys, cooling towers, tall buildings, catenary river crossings and bridges. This
light is compatible with Enhanced Flight Vision Systems that use IR energy emissions for
imaging, including NVG goggles.
FAA Type: L-864 (Red) or L-865 (White) Medium Intensity Lighting
ICAO Type: Medium Intensity Obstacle Light
Applicable Specifications:
Conforms to: FAA Advisory Circular AC 70/7460-1
FAA Advisory Circular AC 150/5345-43 | ICAO Annex 14
Transport Canada TP 382E | DGAC of Mexico 150/5345-43F
Photometric Specifications
Mechanical
Day Mode (White): 20,000 candela ± 25%
Night Mode (White or Red): 2,000 candela ± 25%
Beam Spread: 3° minimum
Horizontal Coverage: 360°, omni-directional
Ground Scatter: <3% Light Output at -10° Vertical
Flash Rate: 40 FPM Day & White Night
Weight, Flashhead: 10 kg (22 lbs)
Weight, Power Supply: 24 kg (53 lbs)
Power Supply Enclosure: 304 Stainless Steel - standard.
316L Stainless Steel - optional
Flashhead Lens Material: High Temp/UV Resistant Acrylic
Stainless Steel - optional 316L
environmental
Electrical
Temperature: -55° to +55° C (-67° F to +130° F)
Will withstand exposure to: 95% relative humidity,
wind-blown rain-direction, salt-laden atmosphere,
Wind Speed - 240kph (150mph)
Input Voltages: 120, 230/240, 277, 480 VAC
Input Frequencies: 50 or 60 Hz
Power Consumption, Day: 208 Watts
Power Consumption, Night: 133 Watts
Power Consumption, Backup: 77 Watts
Peak Inrush Current: 7A @ 120VAC
Available Alarm Contacts (form C dry-contact): Power Failure,
Mode Status, Strobe Failure, Sidelight #1 Fail, Sidelight #2 Fail
16
HUGHEYANDPHILLIPS.COM
MEDIUM INTENSITY
FAA Type: L-864, L-865, or L-866 Medium Intensity Lighting
FlashGuard® 2000B
System Features:
• Single flashhead provides white or red medium intensity
operation with no moving parts
• Precise optics minimize ground scatter light
• Alarm contacts provided for connection to any monitoring
system
• Rugged design of flashhead and power supply is suitable for
outdoor installation in any climate
Flashhead Features:
• Internally triggered Xenon strobe tubes utilized for long-life and
maximum efficiency, without creating corrosive ozone
• Parabolic reflector optics and linear strobe tube optics
combination provides very precise optics and blocks ground
scatter light in both red or white operation
• Lens raises and locks in place, providing easy access to strobe
tubes
• Only three components used in flashhead - minimal
maintenance required at top of structure
• Safety interlock switch included
• No moving parts
• High temperature, UV resistant acrylic flashhead lens
Power Supply Features:
• Provides power electronics, timing circuitry, and monitoring for
lighting system
• Automatic day/night intensity control
• Manual intensity override
• Easily accessible components
• Plug-in-play circuit cards
• Control and monitoring for up two sidelight levels with four
steady burning obstruction lights
• Fail-safe monitoring system with up to five remote alarm
contacts
• Stainless steel NEMA 4X enclosure
• Low power consumption
877.285.4466 Toll Free
17
MEDIUM INTENSITY
FAA Type: L-864 and L-865 Medium Intensity Lighting
FlashGuard® 3000
FlashGuard® 3000 System Description
The FlashGuard 3000 Medium Intensity Dual Lighting System combines a daytime white
strobe light and a nighttime red flashing strobe into a single flashhead, eliminating the
need for two separate lighting systems. The flashhead is powered and controlled by a
power supply that can be mounted remotely at the base of the structure. The power supply
constantly monitors the operation of the system, and provides alarm contact closure upon
any failure. The system automatically switches between day and night intensities by the use
of a calibrated photocell. FlashGuard® 3000 flashheads incorporate a light blocking strip that
minimizes ground scatter light, resulting in a “community friendly” lighting system.
APPLICATION
Medium intensity obstruction lighting systems are typically used on structures between
150’(45M) and 500’ (150M) above ground level to provide aviation safety. The use of a
medium intensity white strobe during the daytime typically eliminates the need to paint the
structure with aviation orange and white stripes. The use of a red flashing beacon at night
provides a “community friendly” light. Hughey & Phillips’ medium intensity obstruction lights
are designed for lighting tall structures such as communication, television and radio towers,
chimneys, cooling towers, tall buildings, catenary river crossings and bridges. This light is
compatible with Enhanced Flight Vision Systems that use IR energy emissions for imaging,
including NVG goggles.
FAA Type: L-864/865 Medium Intensity Lighting
ICAO Type: Type A/B Medium Intensity Obstacle Light
ETL Certified: FAA Advisory Circular 150/5345-43E
Compliant for use with: ICAO Annex 14, MIL-C-7989
DGAC of Mexico, CAR 621.19
Electrical Specifications
Environmental Specifications
AC Input Power 120 VAC +/- 10%, 60 Hz, 1 phase standard; 195 watts day operation,
60 watts alternate white night operation
DC Input Power 24 VDC +/- 10%;120 watts day and red night operation, 45 watts
alternate white night operation
Power Options
240, 480 VAC +/- 10%; 60 Hz or 240, 480 VAC +/- 10%, 50 Hz
TransientTransient protection is provided by:
Protection
• Circuits which incorporate series resistors and zener diodes on
all signal lines
• 5 kilovolt rated transformer, primary and secondary line to
ground insulation
• Rectifier diode network protection by varistors
System StatusTwo neon lamps and four LEDs indicate system and
Indicators subsystem operating status.
System Test
Controls Manual override switches for remote day and night operation testing.
Push button operation for testing fault circuit operation.
SafetyThe flashhead and power supply are both equipped with interlocks
so that opening either unit interrupts the capacitor charging circuit
and discharges the high voltage energy storage capacitors in the
power supply to less than 50 volts within 30 seconds.
Temperature
-67°F (-55°C) to + 130°F (+55°C) per MIL-STD-810
Humidity
95% relative humidity per MIL-STD-810
Wind
Wind speeds up to 150 mph (67 m/sec)
Wind Loading 105 lbs (32 kg) at 150 mpg (240 kph). Surface area is 1.98 ft2
Wind Blown
Rain
Exposure to wind blown rain from any direction per MIL-STD-810
Salt Fog
Exposure to salt-laden atmosphere per MIL-STD-810
optical performance specifications
Mode
Beam Spread1
Peak
Flash
Flash/Rate
Duration3
(degrees)Intensity2
Horizontal Vertical (candelas)
(flashes/minute) (milliseconds)
Day/Twilight 360°
3° min
15,000 min
40-L-865
<10
25,000 max
Night Red
360°
3° min
1,500 min
2,500 max
20-40 for L-864
750
White Night-
360°
3° min
Backup
1,500 min
2,500 max
40 for L-865
100 to 250
Notes:
1. The lower edge of the vertical beam spread lies between –1.5° and -0.5° with respect to the horizon.
2. Flashlamp light out meets the FAA minimum requirements of 15,000 candelas day/twilight and 1,500 candelas night for a period of not less than one year.
3. When the effective flash duration is generated with a group of short flashes, the flash rate is not less than 30 per second.
18
HUGHEYANDPHILLIPS.COM
MEDIUM INTENSITY
FAA Type: L-864 and L-865 Medium Intensity Lighting
FlashGuard® 3000
mechanical dimensions
ss-177 power supply
15.50 (394)
Clearance
18.50 (470)
16.19 (411)
16.26
(412)
10.50 (267)
8.63
(219)
ss 120
photocontrol
w/receptacle
17.25
(438)
5.00
(127)
5.00
(127)
0.44 (11) mounting hole
4 places
Weight: 53 pounds
(24 kilograms)
6.00
(152)
3.38
(86)
3/4” cable connector
3.50
(89)
ss-120 photocontrol is
removable for indoor installation
ss-178 flashhead
877.285.4466 Toll Free
19
MEDIUM INTENSITY
FAA Type: L-864 and L-865 Medium Intensity Lighting
FlashGuard® 3000B
FlashGuard® 3000B System Description
The FlashGuard® 3000B Medium Intensity Dual Lighting System combines a daytime
white strobe light and a nighttime red flashing strobe into a single flashhead, eliminating
the need for two separate lighting systems. The flashhead is powered and controlled by a
power supply that can be mounted remotely at the base of the structure. The power supply
constantly monitors the operation of the system, and provides alarm contact closure upon any
failure. The system automatically switches between day and night intensities by the use of a
calibrated photocell. FlashGuard® 3000B flashheads incorporate a light blocking strip that
minimizes ground scatter light, resulting in a “community friendly” lighting system.
APPLICATION
Medium intensity obstruction lighting systems are typically used on structures between
150’(45M) and 500’ (150M) above ground level to provide aviation safety. The use of a
medium intensity white strobe during the daytime typically eliminates the need to paint the
structure with aviation orange and white stripes. The use of a red flashing beacon at night
provides a “community friendly” light. Hughey & Phillips’ medium intensity obstruction lights
are designed for lighting tall structures such as communication, television and radio towers,
chimneys, cooling towers, tall buildings, catenary river crossings and bridges. This light is
compatible with Enhanced Flight Vision Systems that use IR energy emissions for imaging,
including NVG goggles.
FAA Type: L-864/865 Medium Intensity Lighting
ICAO Type: Type A/B Medium Intensity Obstacle Light
ETL Certified: FAA Advisory Circular 150/5345-43F
Compliant for use with: ICAO Annex 14, MIL-C-7989
DGAC of Mexico, CAR 621.19
Photometric Specifications
Mechanical
Day Mode (White): 20,000 candela ± 25%
Night Mode (White or Red): 2,000 candela ± 25%
Beam Spread: 3° minimum
Horizontal Coverage: 360°, omni-directional
Ground Scatter: <3% Light Output at -10° Vertical
Flash Rate: 40 FPM Day & White Night, 24 FPM Red Night
Weight, Flashhead: 16 kg (34 lbs)
Weight, Power Supply: 32 kg (70 lbs)
Power Supply Enclosure: 304 Stainless Steel - standard.
316L Stainless Steel - optional
Flashhead Lens Material: High Temp/UV Resistant Acrylic
Electrical
Environmental Specifications
Temperature: -55°C to +55°C (-67°F to 130°F)
Humidity: 95% Relative Humidity
Miscellaneous: Will withstand exposure to wind-blown rain
from any direction, salt-laden atmosphere and indspeeds of
240 kph (150 mph).
20
HUGHEYANDPHILLIPS.COM
Input Voltages: 120, 230/240, 277, 480 VAC, 24VDC
Input Frequencies: 50 or 60 Hz
Power Consumption, Day: 208 Watts
Power Consumption, Night: 133 Watts
Power Consumption, Backup: 77 Watts
Peak Inrush Current: 7A @ 120VAC
Available Alarm Contacts (form C dry-contact): Power Failure,
Mode Status, Strobe Failure, Sidelight #1 Fail, Sidelight #2 Fail
MEDIUM INTENSITY
FAA Type: L-864 and L-865 Medium Intensity Lighting
FlashGuard® 3000B
System Features:
• Single flashhead provides white or red medium intensity
operation with no moving parts
• Dual flashtubes and dual trigger transformers provide night
time redundancy - no single point of failure in the flashhead
• Precise optics minimize ground scatter light
• Alarm contacts provided for connection to any monitoring
system
• Rugged design of flashhead and power supply is suitable for
outdoor installation in any climate
Flashhead Features:
• Upper optics provides red flashing beacon lighting
• Lower optics provides medium intensity white strobe lighting
• Identical strobe tube for red and white eliminates extra spare
parts
• Internally triggered Xenon strobe tubes utilized for long-life and
maximum efficiency, without creating corrosive ozone
• Parabolic reflector optics and linear strobe tube optics
combination provides very precise optics and blocks ground
scatter light in both red or white operation
• Lens raises and locks in place, providing easy access to strobe
tubes
• Only five components used in flashhead - minimal maintenance
required at top of structure
• Dual flashtubes and trigger transformers provide night time
redundancy
• Safety interlock switch included
• No moving parts
• High temperature, UV resistant acrylic flashhead lens
Power Supply Features:
• Provides power electronics, timing circuitry, and monitoring for
lighting system
• Automatic day/night intensity control
• Manual intensity override
• Easily accessible components
• Plug-in-play circuit cards
• Control and monitoring for up two sidelight levels with four
steady burning obstruction lights
• Fail-safe monitoring system with up to five remote alarm
contacts
• Stainless steel NEMA 4X enclosure
• Low power consumption
877.285.4466 Toll Free
21
high
intensity
HIGH INTENSITY
FAA Type: L-865 and L-857
StrobeGuard® SS-122/125
SS-125 Obstruction Strobe Light
The StrobeGuard® SS-125 is a single enclosure obstruction light designed to meet or
exceed the requirements of Advisory Circular 150/5345-43. The enclosures are fabricated
from 304L stainless steel. All plug-in printed circuit boards are protected with a coating
which meets the physical and electrical requirements of MIL-I-46058B. The SS-125 is
supplied with a lightning arrestor capable of withstanding repeated 10,000 ampere current
surges. Operated with the SS-122 Controller, the system is completely self-activating for
monitoring and identifying any malfunctioning light and is equipped to initiate a remote
alarm. The number of SS-125 obstruction lights used on an installation depends upon the
type of obstruction and its height.
FAA Type: L-856 High Intensity Lighting
ICAO Type: Type A High Intensity Obstacle Light
ETL Certified: FAA Advisory Circular AC 150/5345-43
Compliant for use with: ICAO Annex 14, Canadian Aviation Regulation 621.19
ICAO Annex 14, MIL-C-7989, DGAC of Mexico
Photometric Specifications
Day 270,000 candela ± 25%
Twilight 20,000 candela ± 25%
Night 2,000 candela ± 25%
Beam Spread 3° Vertical minimum
Horizontal Coverage 120° coverage
Cut off Angle <3% light output at -10° Vertical
Flash Rate 40 Flashes per Minute (FPM)
Environmental
Temperature -55° C to +55° C, -67° F to + 130° F
Humidity 95% relative humidity
Will withstand exposure to: Wind-blown rain from any angle
Salt-laden atmosphere, Wind speed of 240kph (150mph)
24
HUGHEYANDPHILLIPS.COM
Mechanical
Weight, Controller 11kg (24 lbs)
Dimensions, Controller 14” H x 12” W x 6” D
Weight, Flashhead 37kg (82 lbs)
Dimensions, Flashhead 14.4” H x 16.2” W x 12.75” D
Enclosure Rating 304 Stainless Steel, NEMA 4X
Electrical
Input Voltages 120, 208, 240, 277, 380, 480V
Input Frequency 50 or 60 Hz
Power Consumption 0.55kVA per flashhead
HIGH INTENSITY
FAA Type: L-865 and L-857
StrobeGuard® SS-122/125
SS-122 Controller:
Features:
StrobeGuard® Controllers contain the flash interval and timing circuits, intensity selection
controls, and monitoring receivers with status indicators required to operate the SS-125
strobe light. The controller is of modular construction with solid state circuitry for long
life and ease of maintenance. StrobeGuard® controllers are designed to operate up to
32 obstruction lights at distances up to 4700 feet. Each controller is equipped with the
necessary manually operated controls to test all modes of operation. Digital monitor lamps
are provided and illuminate when a flashhead or power supply is not operating as required.
Each monitor lamp is operated in a coded mode indicating the location of the flashhead/
power supply which is malfunctioning.
• Fail-safe monitoring system
• Parabolic Optics minimize ‘ground
scatter’ light: <3% of peak intensity
at -100
• Two-wire cable for sync, mode and
monitoring
• Safety interlocks in each flashhead
• Long-life internally triggered strobe tubes
• Automatic three-level intensity control
• Manual intensity override
• Easily accessible replaceable components
• Plug-in-play circuit cards
• Remote alarm contacts
• Stainless steel NEMA 4X enclosure
• Vertical level indicator and
adjustment system
• Low power consumption
• Minimal wind loading and weight
• IR Compatible with NVG goggles
SS-124 Ambient Sensor:
The SS-124 Light Sensor continuously monitors the ambient lighting conditions and inputs to
the StrobeGuard controller the necessary information to automatically control the switching
of daytime, twilight and nighttime modes of operation. The SS-124 is easy to install with the
built-in mounting holes.
StrobeGuard® Control
StrobeGuard® controls contain the flash interval and timing circuits, intensity selection
controls and monitoring circuitry with status indicators. The StrobeGuard® control system
is designed to operate up to 24 flashheads at a distance of up to 2500 feet (760 M), using
a noise-resistant communications format. Each control is equipped with the necessary
manually operated controls to test all modes of operation. Bi-color green/red LEDs are
provided to indicate proper operation or fault of each flashhead.
877.285.4466 Toll Free
25
international
INTERNATIONAL PRODUCTS
FOR LOW INTENSITY OBSTRUCTION LIGHTS
LED LAMP E27 RTO / OTL
APPLICATION
The LED-lamp was designed to substitute the current 100/116W incandescent lamp in low
intensity obstacle lights type RTO and OTL for the 10cd requirement Low Intensity Obstacle
Lights Type A, acc. To ICAO Annex 14, table 6-3, issue July 2004.
In combination with a clear lens the RTO Obstacle light with LED-Lamp E27 RTO meets
ICAO Low Intensity Obstacle Light Type B (32 cd) – requirement.
Regulations
ICAO annex 14, table 6-3, issue July 2004
CE – regulations
Characteristics
•
•
•
•
•
•
•
Compact and robust design
Replacement for E27 incandescent lamp
Can be substituted into existing obstacle lights
Long life expectancy
Build-in redundancy by redundant connection of LEDs
Power consumption approx. 4W
Wide voltage and frequency range
Technical Data
Dimensions, weight, packing data
•
•
•
•
•
•
•
•
LED Lamp E 27 RTO
• Dimensions: approx. 78.0 x 73.0 mm (h x 0)
• Weight: approx. 0.310 kg
Structure: LED-Lamp as replacement for incandescent lamp
Number of LEDs 6
Color red
Chromaticity acc. To ICAO, annex 14, appendix 1, fig. A1-1
Lamp base E27
Voltage 100V – 230V AC, 50/60 Hz
Power consumption approx. 4 Watt
Temperature range -40OC - + 55OC
Ordering information
65 873 070
65 975 584
28
LED Lamp E27 RTO, 32 cd
LED Lamp E27 OTL, 10 cd
HUGHEYANDPHILLIPS.COM
LED Lamp E 27 OTL
• Dimensions: approx. 84.0 x 73.0 mm (h x 0)
• Weight: approx. 0.310 kg
• Packing unit: 4 pieces
• Box dimensions: approx. 165 x 165 x 110 mm (l x w x h)
INTERNATIONAL PRODUCTS
FOR LOW INTENSITY OBSTRUCTION LIGHTS
LED LAMP E27 RTO / OTL
877.285.4466 Toll Free
29
INTERNATIONAL PRODUCTS
OBSTACLE LIGHTING FOR WIND TURBINES
LED 170W
APPLICATION
Night marking for wind turbines according to the national regulation for marking
obstructions to air traffic “Richtlinie zur Kennzeichnung von Luftfahrthindernissen” issued
by the German Federal Ministry of Transport, Building and Housing. Type “W Red”
Function
A pair of the flashing red obstruction lights LED170 are specified for the night marking of
wind turbines higher than 100m. The timing of the LED170 flashing identifies the marked
obstruction as wind turbine to the pilots of aircrafts. The system automatically switches on
by the use of a calibrated photocell. In order to allow synchronization of the flashing of the
LED170 lights with those on other wind turbines, the LED170 is optionally synchronized by
the use of GPS. The pair of LED170 lights per wind turbine in conjunction with a separate
uninterrupted power supply plus control electronics forms the flashing light system
designed for an individual wind turbine. The LED170 light is maintenance free.
Characteristics
• Maintenance free obstruction light using high-lumen LEDs
• High lifetime by optimized heat dissipation and low operating current of the LEDs
• Constant light output by compensation of temperature changes
• Rugged housing with self-cleaning transparent cover
• Mechanical interface identical to that of the FG2000/3000B light family
• Fault detection
National regulation for marking aeronautical obstacles, part A and B
Technical Data
•
•
•
•
•
•
•
•
•
•
Power Supply system – 690 or 230V, 50Hz
Power Consumption system – Approx. 400VA at start of charge
Mechanical dimensions – 381 x 405 mm (L x H)
Weight – 8.5 kg
Flashhead Power Consumption – 22 Watts
Light Sources – High performance LEDs
Light Intensity – >170cd
Horizontal beam spread – 360°
Vertical beam spread – Min 170cd ±5° Min 34cd ±10° Min 3,4cd ±15°
Timing of flashing: 1s on - 0.5s off - 1s on - 1.5s off
Ordering information
65 874 240 65 874 616 65 874 617 65 874 618 30
LED170W
LED170W
LED170W
LED170W
HUGHEYANDPHILLIPS.COM
230V, 50Hz
690V, 50Hz
230V, 50Hz, with GPS
690V, 50Hz, with GPS
INTERNATIONAL PRODUCTS
OBSTACLE LIGHTING FOR WIND TURBINES
LED 170W
877.285.4466 Toll Free
31
INTERNATIONAL PRODUCTS
FAA Type: L-864 Medium Intensity Lighting
LED 2000
APPLICATION
The flashing red omni-directional medium intensity obstacle light LED 2000 is applied to
mark obstacles.
The LED 2000 is in compliance with ICAO, July 2004. Annex 14, Volume 1, Table 6-3, for
Medium Intensity Obstacles Lights Type B and C.
Steady burning operation at Type C is alternatively possible.
FAA Type: L-864, AC150/5345-43F
ICAO Type: Annex 14, Tables 6-3, July 2004
NATO: Stanag 3316
CE-Mark
characteristics
LED 2000
• LED-Medium Intensity Obstacle Light 2,000cd
• Extremely low light emittance downwards
Light intensity at -1O
Max. 1,125cd
Min. 750cd
•
•
•
•
Effective thermal management
Steady burning operation as Type C light, up to max. environmental temperature of +55OC
Very high lifetime
Redundant circuitry for LEDs
technical data
Dimensions, weight, packing data
Construction:
Number of LED: Color of light: Chromaticity: Photometry:
Main voltage:
Power consumption:
Temperature range:
LED - Obstacle Light
28
Red
according to ICAO, Annex 14, Volume 1, Figure A 1-1
according to ICAO, Annex 14, Volume 1, Table 6-3
Medium Intensity Obstacle Light 2000cd Type B,C
230 V AC + 10%, -15%, 50/60 Hz
80 Watt in steady burning operation
40 Watt in blinking mode
-40OC -+ 55OC
part no.
65 875 918
32
LED 2000
HUGHEYANDPHILLIPS.COM
Dimensions: 335 x 410 mm (H x O)
Weight: appr. 9 kg
Packing unit: 1 piece
Packing size: appr. 600 x 500 x 600 mm (L x W x H)
INTERNATIONAL PRODUCTS
FAA Type: L-864 Medium Intensity Lighting
LED 2000
Fig 1: LED 2000 horizontal light
distribution in beam centre
according to ICAO
Fig 2: LED 2000 horizontal light
distribution at -1O down (-1O Cutoff
condition according to ICAO)
Fig 3: LED 2000 vertical light
distribution according to ICAO
877.285.4466 Toll Free
33
cables
CABLES
77-2992 Cable
ASSEMBLY
ALUMINUM
MYLAR SHIELD
BINDER TAPE
JACKET
11
Ø.600
FILLER
Cabling - Core-minimum filler to keep as flexible as practical
Outer Layer - 7 wires, items 4-10 (4 #14 + 3 #16 AWG)
Cabled around the core with a 7” left hand lay
Binder - 0.002” mylar tape - 25% minimum overlap
Tape shield - 0.002” aluminum mylar tape - 25% minimum overlap
Drain wire - Item 11 is pulled under the shield
Jacket - 0.025 polythlyne - color: black
Overall diameter - Ø.600 MAX
SPECIFICATIONS
• Temperature rating ­­–55°C to +80°C
• Voltage rating 600 VRMS (Conductors 2500 VRMS for electronic use)
• Insulated conductors UL1015 CSA TRE2 IPCEA S–61–402
• Cable UL2653 CSA TR32 IPCEA S–61–402
• Voltage testing Finished cable tested at 2000 VRMS between every two
conductors and between each conductor and the shield. 100% test.
CONDUCTORS
ITEM NO.
SIZE
WIRE
STRANDS/AWG
MATERIAL
INSULATION
COLOR
NOM. DIA.
MATERIAL
4
14 AWG
19/25
COPPER
BLACK
TYPE “B” P.V.C. 600V
Ø.105”
5
14 AWG
19/25
COPPER
WHITE
TYPE “B” P.V.C. 600V
Ø.105”
6
14 AWG
19/25
COPPER
RED
TYPE “B” P.V.C. 600V
Ø.105”
7
14 AWG
19/27
COPPER
ORANGE
TYPE “B” P.V.C. 600V
Ø.105”
8
16 AWG
19/27
COPPER
YELLOW
TYPE “B” P.V.C. 600V
Ø.091”
9
16 AWG
19/27
COPPER
GREEN
TYPE “B” P.V.C. 600V
Ø.091”
10
16 AWG
19/29
COPPER
VIOLET
TYPE “B” P.V.C. 600V
Ø.091”
11
16 AWG
19/29
36
HUGHEYANDPHILLIPS.COM
TINNED COPPER
BARE DRAIN WIRE
CABLES
77-4017
ASSEMBLY
FILLER
Ø.565 ±.03
JACKET
TAPE SHIELD
BINDER TAPE
Cabling - Core- filler, as required to maintain a circular cross section
Outer Layer - 6 wires, items 1-6 (2 #10 + 2 #12 + 2 #18 AWG)
Cabled around the core with a 7” left hand lay
Binder - overall clear polyster. 100% coverage
Tape shield - overall aluminum mylar foil 100% coverage - 20% overlap
Drain wire - Item 7 is 18 AWG 16 strand tinned copper
Jacket - UV inhibiting polyvinyl chloride (PVC)
Overall diameter - Ø.565 ±.03
SPECIFICATIONS
• Temperature rating ­­–43°C to +80°C | stationary –55°C to +80°C
• Voltage rating 600 VRMS (Conductors 2500 VRMS for electronic use)
• Insulated conductors CSA AWM 1/11 6DOV FTA ICEA S–61–402
• Cable UL. standard 1277. Type VNTC. CSA FT4
NEC 340. Sunlight resistant jacket 600 V rated
• Voltage testing Finished cable tested at 2000 VRMS between every
two conductors and between each conductor and the shield. 100% test.
CONDUCTORS
ITEM NO.
SIZE
WIRE
PRIMARY
SECONDARY
STRANDS/AWG STRANDS/AWG
MATERIAL
1
10 AWG
37/26 104/30
TINNED COPPER
2
10 AWG
37/26 104/30
TINNED COPPER
3
12 AWG
19/25
65/30
TINNED COPPER
4
18 AWG
16/30
16/30
TINNED COPPER
5
18 AWG
16/30
16/30
TINNED COPPER
6
12 AWG
19/25
65/30
TINNED COPPER
7
18 AWG
16/30
16/30
TINNED COPPER
INSULATION
COLOR
MATERIAL
(PVC) .020” NOM. WALL
NYLON .005 NDM WALL
(PVC) .020” NOM. WALL
BROWN
NYLON .005 NDM WALL
(PVC) .015” NOM. WALL
BLUE
NYLON .005 NDM WALL
(PVC) .015” NOM. WALL
GRAY
NYLON .005 NDM WALL
(PVC) .015” NOM. WALL
WHITE
NYLON .005 NDM WALL
(PVC) .015” NOM. WALL
BLACK
NYLON .005 NDM WALL
RED
NOM. DIA.
Ø.177”
Ø.177”
Ø.153”
Ø.107”
Ø.107”
Ø.153”
BARE DRAIN WIRE
877.285.4466 Toll Free
37
CABLES
77-4231 Cable
ASSEMBLY
ALUMINUM
MYLAR SHIELD
Cabling - Core-minimum filler to keep as flexible as practical
Outer Layer - 10 wires, items 1-10 (3 #12 + 4 #14 + 3 #16 AWG)
Cabled around the core with a 7” left hand lay
Binder - 0.002” mylar tape - 25% minimum overlap
Tape shield - 0.002” aluminum mylar tape - 25% minimum overlap
Drain wire - Item 11 is pulled under the shield
Jacket - UV inhibiting polyvinyl chloride (PVC)
Black 0.060” nominal wall
Overall diameter - Ø.665 ± 0.3”
BINDER TAPE
JACKET
FILLER
SPECIFICATIONS
• Temperature rating ­­–55°C to +80°C
• Voltage rating 600 VRMS (Conductors 2500 VRMS for electronic use)
• Insulated conductors UL1015 CSA TRE2 IPCEA S–61–402
• Cable UL2653 CSA TR32 IPCEA S–61–402
• Voltage testing Finished cable tested at 2000 VRMS between every two
conductors and between each conductor and the shield. 100% test.
CONDUCTORS
ITEM NO.
SIZE
WIRE
STRANDS/AWG
MATERIAL
INSULATION
COLOR
NOM. DIA.
MATERIAL
1
12 AWG
19/25
COPPER
BLACK
P.V.C. 600V
Ø.124”
2
12 AWG
19/25
COPPER
WHITE
P.V.C. 600V
Ø.124”
3
12 AWG
19/25
COPPER
GREEN
P.V.C. 600V
Ø.124”
4
14 AWG
19/27
COPPER
BLACK
P.V.C. 600V
Ø.105”
5
14 AWG
19/27
COPPER
WHITE
P.V.C. 600V
Ø.105”
6
14 AWG
19/27
COPPER
RED
P.V.C. 600V
Ø.105”
7
14 AWG
19/27
COPPER
ORANGE
P.V.C. 600V
Ø.105”
8
16 AWG
19/29
COPPER
YELLOW
P.V.C. 600V
Ø.091”
9
16 AWG
19/29
COPPER
GREEN
P.V.C. 600V
Ø.091”
10
16 AWG
19/29
COPPER
VIOLET
P.V.C. 600V
Ø.091”
11
18 AWG
16/30TINNED COPPERBARE DRAIN WIRE
38
HUGHEYANDPHILLIPS.COM
CABLES
WC23012CLOT
WC23012DLOT
Type TC-Control or Instrumentation Cable
PVC/Nylon Insulation with Overall PVC Jacket
Scope
Cabling
Three or more conductors are assembled round with fillers as
needed. A nylon rip cord is inserted under the jacket for ease of
stripping. Two conductors are assembled flat parallel (round, with
fillers as needed, is available upon request).
Overall Jacket
Gas/vapor-tight Polyvinyl Chloride (black)
UL1277 table 10.1
Thickness
Specified herein
Color Coding
ICEA Method 3 Table K-2, except colors and numbers are
printed on solid base colors for easy identification.
Cable Identification
Sizes 18 and 16 AWG
Ink print on one side of jacket
“(size) AWG Type TC 90°C dry 75°C wet Sunlight Resistant 600V A.I.W.
Corp. (UL) Direct Burial”
Indent print on other side of jacket
“(number of conductors)”
Sizes 14, 12, and 10 AWG
Ink print on one side of jacket
“(size) AWG Type TC THHN or THWN cdrs. Sunlight Resistant 600V
A.I.W. Corp. (UL) Direct Burial”
Indent print on other side of jacket
“(number of conductors)”
Construction Options
Consult factory for cable specifications with appropriate shields.
Cables made per Dupont Spec. SE-33.4B also available.
This specification covers multiconductor cables having VW-1 TFFN
or THHN/THWN (PVC/Nylon) conductors with an overall gas/
vapor-tight polyvinyl chloride (PVC) jacket, conforming to Article 318
“Cable Trays” and Article 340 “Power and Control Cable Type TC” of
the 1996 National Electrical Code, and Standard 1277 of Underwriters
Laboratories, Inc. Meets the requirements of ICEA T-29-520 and
T-30-520 flame tests as well as the 70,000 BTU “Cable Tray
Propagation Test” per IEEE-383 and shows reserve capabilities by also
pass the 210,000 BTU flame test. Rated 600 volts, 90°C dry and 75°
wet. UL file no. E60749. Also meets FT4/IEEE 1202 70,000 BTU test.
SPECIFICATIONS
UL listed and OSHA acceptable. Recognized for use in Class 1 or 2,
Division 2 hazardous locations and for installation in trays, wireways,
troughs, channels, ducts and conduit. Specifically approved for
direct burial, wet or dry locations and outdoors in cable trays where
a sunlight resistant rating is required. Designed for control, power,
lighting, telemetering, signals and relay or traffic control.
Construction
Conductors
Bare soft annealed copper per ASTM B-3
Sizes 18 and 16 AWG (TFFN)
Bunch stranded. Size 18 (16/.010”) and Size 16 (19/.0117”) UL-62
paragraph 10.2
Sizes 14, 12 and 10 AWG (THHN/THWN)
Concentric stranded, class B (7 strands)
ASTM B-8 and UL-83 table 13.1
Insulation
High dieletric polyvinyl chloride
UL-1581 table 50.145 (THWN 75°C)
UL-1581 table 50.155 (THHN 90°C)
UL-1581 table 50.155 Class 12B (TFFN 90°C)
Thickness
UL-83 table 15.5 for THHN/THWN
UL-62 table 6.2 for TFFN
Insulation Armor
Nylon
UL-83 paragraph 25.1 for THHN/THWN
UL-62 paragraph 22.1 for TFFN Thickness
UL-83 table 15.5 for THHN/THWN
UL-62 paragraph 26.4 for TFFN
877.285.4466 Toll Free
39
DIAGRAMS
DIAGRAMS
9LCA001000AS
INCOMING
POWER
SEE NOTE 1.
TOWER NEUTRAL
OBSTRUCTION LIGHTS
(1-4 116W 120V LAMPS)
NEUTRAL
GROUND
LINE
PHOTOCELL RED
PHOTOCELL BLACK
Product #
AC Description
PART #
Alarm Card, 120V, SL B7C51PAA
CB1 Circuit Breaker, 15A EB152771CMDW
F1 Fuse, 7 Amp (some models, replaces CB1) FUFNM70G251
MC Master Card w/photocell B7C14RAA
MV1-2 Metal Oxide Varistor, 150V 80 Joules MV150LA20
MV3 Metal Oxide Varistor, 24V 4 Joules MV24ZA4
SW1 Day/Night/Auto Switch SZ22030251AK
TB1-E Terminal Block End (1 total) TBE230AA
TB1-S Terminal Block Section (4 total) TBS213AA01A
TBP Photocell Terminal Block, 2 Position TB02B038A07A
9LCA111L00AS
TOWER GROUND
BEACON (2 620W 120V LAMPS)
OBS. LIGHTS (2-4 116W 120V LAMPS)
LOAD BALANCE RESISTOR
TOWER NEUTRAL
GROUND
NEUTRAL
LINE
Product #
AC Description
PART #
Alarm Card, 120V, BCN-SL B7C21PAA
CB1-3 Circuit Breaker, 15A EB152771CMDW
FBP Flasher By-Pass Card, 120V B7C31PAA
K1 Relay, 12V Coil, 20 A, DPDT KA120DV2022C
K2-4 Solid State Relay, NO, 40A KR241DV4011R
MC Master Card w/photocell B7C11RAA
MV1-4 Metal Oxide Varistor, 150V 80 Joules MV150LA20
MV5 Metal Oxide Varistor, 24V 4 Joules MV24ZA4
SW1 Day/Night/Auto Switch SZ22030251AK
TB1/2-E Terminal Block End (2 total) TBE230AA
TB1/2-S Terminal Block Section (9 total) TBS213AA01A
TBP Photocell Terminal Block, 2 Position TB02B038A07A
9LCD111000AS
INPUT POWER
GROUND
NEUTRAL
LINE
TOWER GOUND
STROBE LINE
PHOTO LINE
TOWER NEUTRAL
PHOTOCELL
RED
BLACK
Product #
AC Description
PART #
Alarm Card, 120V, Strobe B7C26PAA
CB1 Circuit Breaker, 15A
EB152771CMDW
K1 Solid State Relay, NO, 40A MC Master Card w/photocell B7C12RAA
KR241DV4011R
MV1-3 Metal Oxide Varistor, 150V 80J MV150LA20
MV4
Metal Oxide Varistor, 24V 4J MV24ZA4
SW1 Day/Night/Auto Switch SZ22030251AK
TB1/2-E Terminal Block End (2 total) TBE230AA
TB1/2-S Terminal Block Section (8 total) TBS213AA01A
TBP K1
42
HUGHEYANDPHILLIPS.COM
Photocell Terminal Block, 2 Position TB02B038A07A
DIAGRAMS
TOWER GROUND
Product #
PHOTOCELL BLACK AND RED
OBS LIGHT LEVEL 2 (3-4 116W 120V LAMPS)
OBS LIGHT LEVEL 1 (3-4 116W 120V LAMPS)
BEACON 1 (2 620W 120V LAMPS)
BEACON 2 (2 620W 120V LAMPS)
BEACON 3 (2 620W 120V LAMPS)
LOAD BALANCE RESISTOR 1
LOAD BALANCE RESISTOR 2
LOAD BALANCE RESISTOR 3
TOWER GROUND
INCOMING NEUTRAL
TOWER NEUTRAL
LINE 1
LINE 2
INCOMING GROUND
9LCA233L00AS
PART #
Alarm Card, 120V, BCN-BCN-BCN B7C24PAA
AC2
Alarm Card, 120V, SL-SL B7C23PAA
CB1-8 Circuit Breaker, 15A EB152771CMDW
FAN Fan, 120V A6A1010AF2
FBP1-3 Flasher By-Pass Card, 120V B7C31PAA
K1-3 Relay, 12V Coil, 20 A, DPDT
KA120DV2022C
K4-12 Solid State Relay, NO, 40A KR241DV4011R
MC Master Card w/photocell B7C11RAA
MV1-8 Metal Oxide Varistor, 150V 80 Joules MV150LA20
MV9 Metal Oxide Varistor, 24V 4 Joules MV24ZA4
SW1 Day/Night/Auto Switch SZ22030251AK
TB1/2-E Terminal Block End (2 total) TBE230AA
TB1/2-S Terminal Block Section (9 total) TBS213AA01A
TB1-NE Terminal Block End White, Large(1 total)TBE830AA
TB1-NS Terminal Block Section White, large (2 total) TBS824AA01A
TBP 9LCE233L0BAS
Description
AC1 Product #
Photocell Terminal Block, 2 Position TB02B038A07A
Description
PART #
AC1 Alarm Card, 120V, OB-OB B7C23PAA
AC2 Alarm Card, 120V, BCN-BCN-BCN B7C24PAA
AC3 Alarm Card, 120V, ST-ST-ST B7C28PAA
BC Backup Card, 120V B7C41PAA
CB1-1 Circuit Breaker, 15A EB152771CMDW
FAN Cooling Fan, 120V A6A1010AF2
FB1-3 Flasher By-Pass Card, 120V B7C31PAA
K1-3 Relay, 12V Coil, 20 A, DPDT KA120DV2022C
K4-12 Solid State Relay, NO, 40A KR241DV4011R
K13 Relay, 120V Coil, DP3T KA121AV0532C
MC Master Card w/photocell B7C13RAA
MV1-12 Metal Oxide Varistor, 150V 80 Joules MV150LA20
MV13 Metal Oxide Varistor, 24V 4 Joules MV24ZA4
SW1 Day/Night/Auto Switch SZ22030251AK
SYNC Strobe Sync Card B6A1101PCB4B
TB1/2-E Terminal Block End (2 total) TBE230AA
TB1/2-S Terminal Block Section (18 total) TBS213AA01A
TBN-E Large Terminal Block End (2 total) TBE830AA
TBN-S Large Terminal Block Section (18 total) TBS824AA01A
TBP Photocell Terminal Block, 2 Position TB02B038A07A
877.285.4466 Toll Free
43
DIAGRAMS
9LCE111L0BAS
Product #
TOWER GROUND
BEACON (2 620W 120V LAMPS
OBS. LIGHTS (2-4 116W 120V LAMPS
MEDIUM INTENSITY STROBE
LOAD BALANCE RESISTOR
PHOTO/HEATER LINE
TOWER NEUTRAL
GROUND
NEUTRAL
LINE
AC Description
PART #
Alarm Card, 120V, BCN-OB-ST B7C25PAA
BC Backup Card, 120V B7C41PAA
CB1-4 Circuit Breaker, 15A EB152771CMDW
FBP Flasher By-Pass Card, 120V B7C31PAA
K1 Relay, 12V Coil, 20 A, DPDT KA120DV2022C
K2-4 Solid State Relay, NO, 40A KR241DV4011R
K5 Relay, 120V Coil, DPDT KA121AV0522C
MC Master Card w/photocell B7C13RAA
MV1-5 Metal Oxide Varistor, 150V 80 Joules MV150LA20
MV6 Metal Oxide Varistor, 24V 4 Joules MV24ZA4
SW1 Day/Night/Auto Switch SZ22030251AK
TB1/2-E Terminal Block End (2 total) TBE230AA
TB1/2-S Terminal Block Section (9 total) TBS213AA01A
TBP Photocell Terminal Block, 2 Position TB02B038A07A
RED
BLACK
PHOTOCELL
FG2000/2000B
FG3000/3000B
44
HUGHEYANDPHILLIPS.COM
Product #
Description
PART #
FH1 Flashhead Complete, FG2000 (white) *277-4045E
FH1 Flashhead Complete, FG2009 (red) *277-4153E
FH1
Flashhead Complete, FG2000B (white) *277-5047W
FH1 Flashhead Complete, FG2009B (red) *277-5047R
FT1 Flashtube Assembly 12S00602
B1 Base Assembly (w/gasket & lens holders) *77-4103
G1
Lens Gasket, 14” AS568A-383
G2 Lower Cover Gasket, 11.5” AS568A-380
GL1 Globe Assembly, FG2000 (white) *77-4036-001
GL1 Globe Assembly, FG2009 & FG2009B (red) *77-4036-003
GL1 Globe Assembly, FG2000B (white) *77-4036-002
IC1-2 Insulator Cups *77-4182
FH1-6 Flashtube Holder *77-4026
S1 Interlock Switch *77-2644
TB1 Terminal Block Assembly *77-3965
T1 Trigger Transformer *77-4040W
Product #
Description
PART #
FH1 Flashhead Complete, FG3000 *277-4173E
FH1 Flashhead Complete, FG3000B *277-5004RW
FT1-2 Flashtube Assembly
12S00602
B1 Base Assembly (w/gasket & globe holders) *77-4103
G1 Lens Gasket, 14” AS568A-383
G2 Lower Cover Gasket, 11.5” AS568A-380
GL1 Globe Assembly, FG3000 *277-5095-004
GL1 Globe Assembly, FG3000B *277-5095-001
ICL Insulator Cup, Lower *77-4182
ICU Insulator Cup, Upper *77-4181-001
FTH
Flashtube Holder *77-4026
S1 Interlock Switch *77-2644
TB1 Terminal Block Assembly *77-3965
K1 *77-4192
Trigger Transformer relay (FG3000 only) T1 Trigger Transformer, White *77-4040W
T2 Trigger Transformer, Red *77-4040R
DIAGRAMS
FG2000
FG2000B AOL
Product #
Description
PART #
C1 Capacitor, Resonating, 4uF *77-3911
C2 Capacitor, Day, 70uF *77-3949
C3 Capacitor, Night, 5uF *77-4104
DB1 Diode Board *277-3939
E1 Stainless Steel Enclosure, FG2000/3000 *77-4219
F1 Input Power Fuse, 4Amp *DP-1020
HV High Voltage Board *277-3937
K1-2 Interlock & Day/Night Relay *77-2013
MB1 Mother Board *77-3967
PC Photocell *77-3259
PC1 Photocell w/socket *77-3259PCA
PS1 FlashGuard 2000 PS, 120V 60Hz *277-397161A
PS2 FlashGuard 2000B PS, 230V 50Hz *277-397153A
R1 Power Resistor, 50ohm, 55Watt *77-3959
R2-4 Power Resistor, 20ohm, 40Watt *77-2759
S1 Interlock Switch *77-2644
S2 Interlock Switch Assembly *277-3990
SM1 Sync Monitor Board *277-4116
T1 Power Transformer, 120/240V 60Hz *77-3970
T1 Power Transformer, 240/480V 60Hz *77-4137
T1 Power Transformer, 240/480V 50Hz *77-4138C
T2 Current Sense Transformer 40000679-001
TC1 Trigger Control Board *277-4123
TF1 Transformer Fuse, 630mA *DP-1019
Product #
Description
PART #
C1 Capacitor, Resonating, 4uF *77-3911
C2 Capacitor, Day, 70uF *77-3949
C3 Capacitor, Night, 5uF CA505B661CDG
HIGH VOLTAGE
INDICATOR DS1
SW1: AUTO-RESET TEST BUTTON
DB1 Diode Board *277-3939
DCC Digital Controller Board 40000031-003
E1 Stainless Steel Enclosure 40000678-003
F1-F2
Input Power Fuse, 6Amp *77-1167
DS1: LOGIC POWER (RED)
DS2: FLASH STATUS (YELLOW)
DS3: COMMUNICATION STATUS GREEN
HV High Voltage/Trigger Board 34E00010-001
K1-2 Interlock & Day/Night Relay *77-3870
MB1
Mother Board *277-5053-002
R1 Power Resistor, 50ohm, 55Watt *77-3959
R2-4 Power Resistor, 20ohm, 40Watt *77-2759
R5 Power Resistor, 1.5kohm, 50Watt RW000002
S1 Interlock Switch Assembly *277-5093
T1 *77-5066
Power Transformer, 240/480V 60Hz T2 Current Sense Transformer 40000679-001
T3 Trigger Line Driver Board *277-5105
T4 Logic Transformer TP000005
T5 Power Line Transformer TF1 Transformer Fuse, 630mA 1A91324H34
*DP-1019
877.285.4466 Toll Free
45
DIAGRAMS
FG3003
FG2000B
Product #
Description
PART #
C1 Capacitor, Resonating, 3uF *77-3311
C2 Capacitor, Day, 40uF *77-3949
C3 Capacitor, Night, 7uF *77-3982
CNV1 DC-DC Converter, 24VDC-1000VDC *77-4128
DB1 Diode Board *277-3939
E1 Stainless Steel Enclosure *77-4219
F1,F3 Input Power/Sidelight Fuse, 12Amp *77-4136
HV High Voltage Circuit Card *277-4131
K1-2 Interlock & Day/Night Relay *77-3870
MB1
Mother Board *277-4208
PC Photocell w/21’ cable 12H00107
PS1 FlashGuard 3000 Power Supply, 24VDC *277-417500L
R2-4 Power Resistor, 20ohm, 40Watt *77-2759
S1 Interlock Switch *77-2644
SL1 Photocontroller/Sidelight Monitor Assembly 12H00109-1
SM1 Sync Monitor Board *277-4163
SW1 Interlock Switch Assembly *277-3990DC
T2 Current Sense Transformer 40000679-001
TB2 Terminal Block Assembly *77-3965
TC1 Trigger Control Board *277-4169
Product #
Description
PART #
C1 Capacitor, Resonating, 4uF *77-3911
C2 Capacitor, Day, 70uF *77-3949
C3 Capacitor, Night, 5uF CA505B661CDG
DB1 Diode Board *277-3939
DCC Digital Controller Board 40000031-003
E1 Stainless Steel Enclosure 40000678-004
F1-F2 Input Power Fuse, 6Amp *77-1167
HV High Voltage/Trigger Board 34E00010-001
K1-2
Interlock & Day/Night Relay *77-3870
MB1 Mother Board *277-5053-002
R1 Power Resistor, 50ohm, 55Watt *77-3959
R2-4 Power Resistor, 20ohm, 40Watt *77-2759
R5 Power Resistor, 1.5kohm, 50Watt RW000002
S1 Interlock Switch Assembly *277-5093
T1 *77-5066
Power Transformer, 240/480V 60Hz T2 Current Sense Transformer 40000679-001
T3 Trigger Line Driver Board *277-5105
T4
Logic Transformer TP000005
T5 Power Line Transformer TF1 Transformer Fuse, 630mA 46
HUGHEYANDPHILLIPS.COM
1A91324H34
*DP-1019
DIAGRAMS
FG2009
Product #
ALN Description
Alarm Lockout Relay Assembly, Day (not shown) FG2009B
PART #
Product #
Description
PART #
35E00101
C1 Capacitor, Resonating, 4uF CA505B661CDG
C1 Capacitor, Resonating, 3uF *77-3311
C3 Capacitor, Night, 5uF *77-3911
C2 Capacitor, Day, 40uF *77-3949
DB1 Diode Board *277-3939
C3 Capacitor, Night, 7uF *77-3982
E1 Stainless Steel Enclosure, FG2000B/3000B 40000678-004
DB1 Diode Board *277-3939
F1/F3 Input Power Fuse, 6Amp *77-1167
E1 Stainless Steel Enclosure *77-4219
HV High Voltage Board *277-3937
F1 Input Power Fuse, 10Amp *77-2040
K1-2 Interlock & Day/Night Relay *77-2013
F3 *DP-1020
K4 Sidelight Power Relay KA121AV0522C
HV High Voltage Board *277-3937
MB1 Mother Board *277-5016-001
K1-2 Interlock & Day/Night Relay *77-2013
PC Photocell *77-3259
K4 Sidelight Module Sensor *77-4196
PC1 Photocell w/socket *77-3259PCA
K5
Sidelight Module Power Relay *77-4198
PS1 FlashGuard 2009B Power Supply, 120V 60Hz 40000681-027
MB1 Mother Board *277-4208
PS2 FG2009B Power Supply, 120V – No Sidelight 40000681-028
MP1 Interlock Switch Assembly *277-3990
R1 Power Resistor, 50ohm, 55Watt RW50RB0500GF
PC Photocell, Night *77-3258
R2-4 Power Resistor, 20ohm, 40Watt *77-2759
PC1 Photocell, Night w/socket *77-3258PCA
R5 Power Resistor, 1.5kohm, 50Watt 40000683-001
R1
Power Resistor, 10kohm, 55Watt *77-3959
R6-7
Power Resistor, 50kohm, 50Watt RW50RB0502GF
R2-4 Power Resistor, 20ohm, 40Watt *77-2759
S1 Interlock Switch *77-2644
S1 Interlock Switch *77-2644
S2 Interlock Switch Assembly 40000677-001
SLM1 Sidelight Control Module (w/terminal block) *277-4195
SLM1 Sidelight Control Module B7C23PAA
SM1 Sync Monitor Board *277-4163
SM1 Sync Monitor Board *277-4163
T1 Power Transformer, 120/240V 60Hz *77-3970C
T1 Power Transformer, 120/240V 60Hz *77-5002
T1 Power Transformer, 240/480V 60Hz *77-4137C
T2 Current Sense Transformer 40000679-001
T1 Power Transformer, 240/480V 50Hz *77-4138C
TC1 Trigger Control Board *277-5014-003
T2 Current Sense Transformer 40000679-001
TF1 Transformer Fuse, 630mA *DP-1019
TB2 Terminal Block Assembly *77-3965
TC1 Trigger Control Board *277-4169
TF1 Transformer Fuse, 630mA *DP-1019
Sidelight Fuse, 4Amp 877.285.4466 Toll Free
47
DIAGRAMS
FG3000
Product #
FG3000B
Description
PART #
C1 Capacitor, Resonating, 3uF *77-3311
C1 Capacitor, Resonating, 5uF CA505B661CDG
C2 Capacitor, Day, 40uF *77-3949
C2 C3 Capacitor, Night, 7uF *77-3982
C3 Capacitor, Night, 4uF *77-3911
DB1 Diode Board *277-3939
DB1 Diode Board *277-3939
E1 Stainless Steel Enclosure *77-4219
E1 Stainless Steel Enclosure, FG2000B/3000B 40000678-004
F1 Input Power Fuse, 10Amp *77-2040
F1/F3 Input Power Fuse, 6Amp *77-1167
F3 *DP-1020
HV High Voltage Board *277-3937
HV High Voltage Board *277-3937
K1-2 Interlock & Day/Night Relay *77-2013
K1-2 Interlock & Day/Night Relay *77-2013
K3 Trigger Transformer Relay KA025DC10S2N
K4 Sidelight Module Sensor *77-4196
K4 Sidelight Power Relay KA121AV0522C
K5 Sidelight Module Power Relay *77-4198
MB1 Mother Board *277-5016-001
MB1 Mother Board *277-4208
PC Photocell *77-3259
MP1 Interlock Switch Assembly *277-3990
PC1 Photocell w/socket *77-3259PCA
PC Photocell *77-3259
PS1 FlashGuard 3000B Power Supply, 120V 60Hz 40000681-033
PC1 Photocell w/socket *77-3259PCA
R1 Power Resistor, 50ohm, 55Watt RW50RB0500GF
R1 Power Resistor, 10kohm, 55Watt *77-3959
R2-4 Power Resistor, 20ohm, 40Watt *77-2759
R2-4 Power Resistor, 20ohm, 40Watt *77-2759
R5 Power Resistor, 1.5kohm, 50Watt RW000002
S1 Interlock Switch *77-2644
R6-7 Power Resistor, 50kohm, 50Watt RW50RB0502GF
SLM1 Sidelight Control Module (w/terminal block) *277-4195
S1 Interlock Switch *77-2644
SM1 Sync Monitor Board *277-4163
S2
Interlock Switch Assembly 40000677-001
T1 Power Transformer, 120/240V 60Hz *77-3970C
SLM1 Sidelight Control Module B7C23PAA
T1 Power Transformer, 240/480V 60Hz *77-4137C
SLM1
T1 Power Transformer, 240/480V 50Hz *77-4138C
SM1 Sync Monitor Board *277-4163
T2 Current Sense Transformer 40000679-001
T1 Power Transformer, 120/240V 60Hz *77-5002
TB2 Terminal Block Assembly *77-3965
T1 Power Transformer, 240/480V 60Hz *77-5066
TC1 Trigger Control Board *277-4169
T1 Power Transformer, 240/480V 50Hz *77-5067
TF1 Transformer Fuse, 630mA *DP-1019
T2 Current Sense Transformer 40000679-001
TC1 Trigger Control Board *277-5014-003
TF1 Transformer Fuse, 630mA *DP-1019
48
Sidelight Fuse, 4Amp HUGHEYANDPHILLIPS.COM
Product #
Description
Capacitor, Day, 70uf PART #
CA706A441EK
Sidelight Control Module, LEDB7C23LAA-001
DIAGRAMS
SS-125
Product #
SS-122
Description
PART #
Product #
Description
PART #
A1 High Voltage Supply Board *277-3261
MB Mother Board, SS-122 *277-3047
A2 Trigger Control Board *277-3262
A1 Sync & Timing Board *277-2673
A3 *277-3263
A2 Digital Monitor Board, 1-8 Lights *277-2536
C1 Capacitor, 1uF, 1700V *77-4220
A3 Digital Monitor Board, 9-16 Lights *277-2537
C2 Capacitor, 12.5uF, 2500V *77-4108
A4 Digital Monitor Board, 17-24 Lights *277-2538
C3 Capacitor, 110uF, 2500V *77-4133-001
K4-K5 Relay *77-2710
C4 Capacitor, 3uF, 2500V *77-3311
K1-3, K6-K7 Relay, 3PDT *77-3041
DB1 *277-3342-6
T1 Logic Transformer *277-2214
DS1 Interlock Assembly (w/ S1-S3) *77-3323
T2 Power Transformer, 240/480V, 50/60Hz *77-2549
E1 Stainless Steel Enclosure, SS-125 *77-3296-02
T2 Power Transformer, 120/240V, 50/60Hz *77-3886
F1 Fuse, SB, 3.2A – 480V System *77-2041
T2 Power Transformer, 208/220V, 50/60Hz *77-3144
F1 Fuse, SB, 6A – 240V System *77-1167
F1 Fuse, SB, 10A *77-2040
F1 Fuse, SB, 10A – 120V System *77-2040
F2-F5 Fuse, SB, 1A, 3AG *77-2365
PCELL Photocell Assembly, SS-124 *277-3247
FT Flashtube Assembly *77-3295
PR Photocell Receptacle *77-3257
FTS Flashtube Assembly with sockets *77-3295S
PN Photocell, Night *77-3259
K1 Interlock Relay *77-2878
PT Photocell, Twilight *77-3258
K2-K4 Mode Relays *77-2013
LA Surge Arrestor *77-4139
MB Mother Board *277-3264
R1-R6 Resistor Block Assembly *277-3546
RA Reflector Assembly *277-3898
Fault Monitor Board Diode Block S1 Interlock Switch *77-2644
S2 Remote/Local Switch *77-2668
S3 Mode Switch (Day, Twilight, Night) *77-2667
T1 Input Transformer, 60Hz *77-3890
T1 Input Transformer, 50Hz *77-4244
T1-SB T1 Voltage Selector Block, 120V *77-3319
T1-SBT1 Voltage Selector Block, 240V *77-3321
T1-SB T1 Voltage Selector Block, 480V *77-3322
T2 Trigger Transformer Assembly *277-3324
WH *77-3355A
Wire Harness Assembly SS-124 Photocell Assembly
877.285.4466 Toll Free
49
DIAGRAMS
KG114F0001
Product #
DL Description
Dome Lens, red, beacon LC-5000
PART #
SFL150
UL Upper Lens, red, beacon SFL125
LL
SFL100
EB WS Lower Lens, red, beacon (x2) Eyebolt Assembly Wire Set Assembly 6A0002SAY
A6A0001WA
UR Upper Beacon Rods (x3) B6A0002AF2
LR
Lower Beacon Rods (x3) GS Gasket Set (9 total) WT Watertight Connector, 1” A6A0002AG
A6A0002AR
WT4A037050TT
CB Cable Assembly, #12-3C, 12 Feet A6A0001WC12
LH Lamp, beacon, 620 Watt, 120VAC LH620120GE
LH Lamp, beacon, 700 Watt, 230VAC LH700230HDT
SK Socket, lamp, mogol, CSA, 2500W 240V XLFC5S300
SK Socket, lamp, mogol, 2500W 240V XL000001
50
HUGHEYANDPHILLIPS.COM
Product #
Description
PART #
MB-1 Micro-Controller board, A-0 40000444-001
MB-2 Micro-Controller board, A-1 40000444-002
MB-3 Micro-Controller board, A-2/3 40000444-003
K1-K4 Solid State Relay, 50A, NC KM121AV50D2D
F1 0.1A 250V Slo-Blo Fuse 40000408-001
F2-F5 12A 250V Slo-Blo Fuse 40000409-001
F6 1A 250V Slo-Blo Fuse *77-2365
F7, F8 5A 250V Slo-Blo Fuse 40000410-001
F9-F11 12A 250V Slo-Blo Fuse 40000409-001
PCELL Photocell, 120V, Night *77-3258
DIAGRAMS
OB20 SERIES
MBC2161B45S
TO PHOTOCELL
SIDELIGHT FAILURE
BEACON FAILURE
FLASHER FAILURE
LIGHTS ‘ON’
POWER FAILURE
COMMON
Product #
Description
PART #
Product #
Description
PART #
CC L-810 Casting Cover, painted, double C6A0008AB2
FB Fuse, Beacon, 15A FUKTK150601
CL Sidelight Latch Spring A6A0008AJ
FR Fuse, Load Balance Resistor, 7A FUFNM70G251
CS L-810 Casting, painted, single, bottom hub 15H00600-1
FS Fuse, Sidelight, 5A FUFNM50G251
CS L-810 Casting, painted, single, side hub C6A0005AA21
K2 Power Relay, Solid State, 30A, 120V KR241AV120NC
CS L-810 Casting, painted, double, bottom hub C6A0008AA21
K5
Flasher By-Pass Relay Assembly A6C0015AG
CS L-810 Casting, painted, double, side hub C6A0022AA21
KZ Beacon Flasher Assembly KZ1L1RR30A
GS Gasket, neoprene A6A0008AG
MB Mother Board D6C0015AB01
LH Lens Holder Assembly with 7” chain B6A0008AA
PC Photocell Assembly
PA446F21BS
LP Lamp, 116W, 120V LH116120GE
PI-PECB Photo Control Board B6P0004AD
LP Lamp, 116W, 230V LH116230DT
WH Wire Harness LS Lens, Red, fresnel, L-810 FL02B02810
TB1-E Terminal Block End TBE230AA
LS Lens, Clear FL0CB02810
TB1-S Terminal Block Section TBS213AA01A
LS Lens, Yellow FL04B02810
TB2-E Terminal Block End TBE330AA
LS Lens, Green (when lit) FL08B02810
TB2-F Terminal Block Section TBS213AA01A
LS Lens, Blue (when lit) FL06B02861T
TB2-S Terminal Block, Fusible TBS352AA01A
LT Sidelight Latch A6A0008AD
PN Sidelight Spring Pin PS07501002D0
PR 1” to ¾” Pipe reducer PR0304B4R
SS Lamp socket, porcelain, 660W, 250V XLCB4S2200
TR Transfer relay assembly with relay &sockets 6A0013SK3
6C0015AH
TR-R Transfer Relay, 0.3A Coil 13Amp OBRL100
877.285.4466 Toll Free
51
Accessories
ACCESSORIES
9LC CONTROL
SYSTEM
APPLICATION
9LC series lighting controls combine the finest in digital circuitry with rugged
electromechanical hardware to yield the industry’s most comprehensive obstruction
lighting controls. Standard models are available for all common FAA and ICAO
applications. The 9LC’s modular design allows for custom controls for almost any
combination of flashing red beacons and sidelights. All models include a NEMA 4 outdoor
housing and a calibrated photocell for automatic day/night switching. A photocell override
switch is standard on all systems, facilitation troubleshooting or maintenance. All controls
provide comprehensive status indicators and alarm contacts for easy connection to remote
monitoring systems.
Features
• Controls for multiple beacons flash all beacons simultaneously per FAA and
ICAO specifications
• Lightning protection provided by:
-Circuit breaker protection to all tower lighting circuits
- MOV surge suppressors on all inputs, outputs, and photocell lines
-Torroidal current sensors isolate tower lines from monitoring circuitry
• Load balance resistor capability is available
• Modular design allows customization for nearly any application
• Dozens of models already developed for control of up to 14 beacons
• Standard with NEMA 4 enclosures (NEMA 4X optional upgrade)
Alarm Contacts / Control Status
• Individual alarm contacts and control status is provided for:
-Control power failure
- Day/night mode status
- Each flashing red beacon
- Each level of steady burning obstruction lights
- Flasher by-pass alarm/status for each beacon
• Number of lamps being monitored can easily changed by setting dip-switches
• Bi-color red/green LED status indicators provide instant indication of alarm and
control status
• Normally open and normally closed alarm contacts are both available
• Primary and auxiliary alarm contacts provided
Lighting
StructureInput Voltage
Model #
SystemTypeHeight
(50/60Hz)Beacons
Sidelight
LBR
Strobes
LevelsCapability
9LCA001000AA
FAA A-0Incandescent
0 - 150’
120V
0
1No
9LCA111L00AA
FAA A-1Incandescent
151’ - 350’
120V
1
1
Yes
9LCA233L00AA
FAA A-2Incandescent
351’ - 700’
120V
3
2
Yes
9LCA354L10AA
FAA A-3Incandescent
701’ - 1050’
120V
5
3
Yes
1051’ - 1400’
120V
7
4
Yes
9LCA474L10AA
FAA A-4Incandescent
9LCD111000AA
FAA D-1
Strobe
200’ -350’
Strobe
120V
1No
3No
9LCD231000AA
FAA D-2
351’ - 500’
120V
9LCE111L0BAA
FAA E-1Inc/Strobe
200’ -350’
120V
1
1
Yes
9LCE233L0BAA
FAA E-2Inc/Strobe
351’ - 500’
120V
3
3
Yes
9LCIA06000AAICAO A-0Incandescent
0 - 150’
230V
1No
9LCIB16L00AAICAO A-1Incandescent
151’ - 350’
230V
1
1
Yes
9LCIB26L00AAICAO A-2Incandescent
350’ – 700’
230V
2
1
Yes
9LCIC16L00AAICAO A-1Incandescent
151’ - 350’
230V
1
2
Yes
9LCID16L00AAICAO A-1Incandescent
151’ - 350’
230V
1
3
Yes
9LCR001000AA
FAA A-0
LED
0 - 150’
9LCR111000AA
FAA A-1
LED
151’ - 350’
9LCR231000AA
FAA A-2
LED
351’ - 700’
120V
3
2No
9LCR354000AA
FAA A-3
LED
701’ - 1050’
120V
5
3No
54
HUGHEYANDPHILLIPS.COM
120V
1No
120V
1No
1
ACCESSORIES
LC-5000 Red
Lighting
Controller
APPLICATION
The LC-5000 series lighting controls combine the finest in digital circuitry with rugged
microprocessor based hardware to yield the industry’s most comprehensive obstruction
lighting controller. The LC-5000 design allows for quick installation. The ‘auto-configure’
design will evaluate the lighting on the tower and configure itself to operate and monitor
installed lighting. All models include a NEMA 4 outdoor housing and a calibrated
photocell for automatic day/night switching. A photocell override switch is standard on all
systems, facilitation troubleshooting or maintenance. All controls provide comprehensive
status indicators and alarm contacts for easy connection to remote monitoring systems.
Features
• Controls for multiple beacons flash all beacons simultaneously per FAA and
ICAO specifications
• Lightning protection provided by:
–Circuit breaker protection to all tower lighting circuits
– MOV surge suppressors on all inputs, outputs, and photocell lines
–Torroidal current sensors isolate tower lines from monitoring circuitry
• Diagnostic LED Tree provides instant verification of beacons and sidelights
• Modular design allows customization for nearly any application
• Dozens of models already developed for control of up to 14 beacons
• Standard with NEMA 4 enclosures (NEMA 4X optional upgrade)
Alarm Contacts / Control Status
• Bi-color red/green LED status indicators provide instant indication of
alarm and control status
• Normally open and normally closed alarm contacts are both available
• Primary and auxiliary alarm contacts provided
dimensional diagrams
SIDE VIEW
FRONT
VIEW
Environmental
Temperature -55° C to +55° C, -67° F to + 130° F
Humidity 95% relative humidity
Will withstand exposure to: Wind-blown rain
from any angle
Wind speed of 240kph (150mph)
NEMA Rating NEMA 4
Weight 10 lbs.
model Numberssystem type
input voltage
LC5000-001 Incandescent or LED A-O
120V or 240V
LC5000-002 Incandescent or LED A-O or A-1
120V or 240V
LC5000-003Incandescent or LED A-O or A-1 or A-2 120V or 240V
877.285.4466 Toll Free
55
ACCESSORIES
Lightning Surge
Protection
Device LSPD-3000B
APPLICATION
LSPD devices are designed to protect all the FlashGuardTM medium intensity strobe lighting
systems. The LSPD provides both a grounding solution and surge suppression for these
installations. The LSPD minimizes exposure to lightning damage through tower light wiring,
a lightning path that is commonly overlooked at communications sites. Without the use of
a LSPD, the interconnecting cable between the strobe’s flashhead and the power supply
provides a direct path that can allow damaging surges and transients to enter the shelter.
Sites with LSPDs installed have proven reliability. Sites with previous lightning problems
have recorded hundreds of lightning strikes after LSPD installation, with no damage to the
power supply or communication equipment.
Installation
LSPD units are installed between the flashhead and the power supply, providing protection
for both the lighting power supply and the telecommunications equipment installed at
the site. The LSPD units are supplied in a fiberglass NEMA 4X outdoor enclosure. The
protectors should be mounted on the tower above the ice bridge, before the cable turns
to enter the shelter. The first level of protection forces any induced voltage on the cable’s
shield to tower ground. All lines then pass through a surge suppression device before
continuing to the power supply. Detailed installation instructions are included with each
unit and should be adhered to for optimum protection.
FAA Type: L-864 Medium Intensity Lighting
ICAO Type: Medium Intensity Type B (L-864)
Compliant to: Canadian Aviation Regulation (CAR) 621.19 DGAC of Mexico
ICAO Annex 14, CAR 621.19
Specifications:
Response Time
Less than 5 µs.
Current Withstand
40 kA per mode; IEEE C62.41 8x20µs short circuit waveform
CircuitryThe LSPD is series wired with parallel protection. Robust MOVs protect all circuits. Large ground plane bonded to a
#2 copper ground lug provides a strong electrical/ mechanical discharge point.
SERIES 800 PhotoController &
Beacon Flasher
application
The Hughey & Phillips SERIES 800 PhotoController and Beacon Flasher provides a low cost,
high reliability solution to your lighting needs. This unalarmed system allows for the user to
add an inline system to their conduit run on the tower to controller the installed FAA beacons
and sidelights. The systems are factory calibrated and never need adjustment. Each system
utilizes surge and transient components and additional input line protection. Normally
closed solid state relay configuration assures “Lights ON” condition even if the circuitry fails.
Red LED provides quick visual verification of field operation. And with its modular design, it
allows for quick field installation or retrofit to existing system if ever damaged.
model Numbers Description
S800PC120 Photo Controller, 120VAC
S800PC240
Photo Controller, 240VAC
S800BF120Beacon Flasher, 120VAC
S800BF240Beacon Flasher, 240VAC
56
HUGHEYANDPHILLIPS.COM
Spare Parts
Hughey & Phillips is the OEM
for all your needs
• Flashtubes
• Cables
• Wire Harnesses
• Junction Boxes
• Lamps
• Relays
• Capacitors
• Lightning Rods
• Transformers
• Ice Shields
• Brackets
ACCESSORIES
APPLICATION
Combining technology with ease-of-use, Hughey & Phillips’ third-generation GPS unit
combines flash synchronization and day-night sensing, and can be installed with just one
plug-in cable. This eliminates the need to mount a separate GPS unit, antenna, junction
box and wiring. Reliable, glitch-free operation is assured, using a crystal and the 50/60Hz
power line as a zero-drift timing reference if the satellite signal is momentarily lost. And
two different flash modes are provided: fixed 40FPM or bit-switch selectable 24, 30, 40
or 60 FPM. The unit easily mounts with four screws to any surface, or pole mount using
the optional bracket. Installation interconnect cable with quick connect plugs from GPS
unit to controller unit. LEDs indicate Power, Sync and GPS Lock status. With rugged metal
weatherproof and a battery-free design, Hughey & Phillips’ GPS unit will provide years of
reliable service for your wind farm.
GPS SYNC /
Photocell
Module
FAA Advisory Circular AC 150/5345-43F
Canadian Aviation Regulation 621.19
ICAO Annex 14, MIL-C-7989, DGAC of Mexico
Specifications
Specifications
Input Voltage 100-132VAC 50/60Hz, 10W max.
External Dimensions Enclosure
NEMA 4 Painted Aluminum
Mounting Dimensions
Operation Temperature
-40° to +55° C
Indicators
Power (Green)
GPS Lock (Yellow)
Optional Mounting
SYNC (Flashing Red)Bracket
SYNC Output
15-27VDC, 100mA, 3ms pulse
SYNC Adjustments
Day: 40FPM
Night: 24, 30, 40, 60 FPM
Backup SYNCInternal Crystal Clock or
AC Line
6-1/4” x 6-1/4” x 4-1/8”
5-1/8” x 6-3/4”
(4) #8 Holes
1-1/4” to 2-3/4” Pole
Part Numbers
Part Numbers
40002075-001 GPS SYNC Module *77-3259 Photocell, 120V, 35-60 ft-cd 40002074-001 GPS Cable, 25’ 40002074-002 GPS Cable, 50’ 40002074-003 GPS Cable, 100’
40002074-004 GPS Cable, 150’
40002074-005 GPS Cable, 350’
40002082-001 Pole Mounting Kit
877.285.4466 Toll Free
57
ACCESSORIES
Lightning Rod
Assembly
Mounting Bracket
for Dual Lighting
Part # KG 0926M001
MOUNTING RING
LIGHTNING ROD
JAM NUT
BEACON
Application
The Lightning Rod Assembly, LRB58L7510M, is designed for, and
is widely used on antenna towers associated with microwave relay
installations, high-definition broadcast towers, and other structures
prone to lightning strikes. Consisting of a 7/8” diameter rod and a
base mounting ring designed for ready installation under existing
medium intensity lighting fixtures with a 13-1/4” bolt hole pattern.
The A6A0302AB Lightning Rod extends approximately two feet
above a standard 300mm code beacon in order to reduce the
probability that lightning will strike the lighting fixture. This will
minimize the possibility of damage to the lighting fixture and the
wiring from cloud to ground lightning strikes
Ease of Installation
The base mounting ring is designed for installation underneath the base
of a medium intensity lighting fixture with a 13-1/4” bolt hole pattern
without requiring additional holes in the tower. It is only necessary to
remove two of the four mounting bolts in order to install the ring under
the existing fixture. The other two beacon mounting bolts must be
loosened sufficiently to enable the installer to slide the lightning rod
mounting ring under the fixture. Slotted holes are provided in the base
mounting ring in order that the ring may be rotated to avoid interference
with the tower bolts or details. The mounting ring should be positioned
so that the rod is located at either side of the fixture in order to avoid
interference during opening of the fixture for maintenance.
General
The base mounting ring is an aluminum casting, tapped to accept
the threaded rod. The rod is fabricated from 7/8” diameter material
threaded at one end for insertion into the mounting ring. The rod is
specially treated after fabrication to withstand weathering
58
STROBE
TOWER
BEACON/STROBE MOUNTING BRACKET
Strobe Mounting
Bracket For:
1. Model KG114 - Red Beacon
2. Model KG225 - Strobe
3. Model FG2000 - Strobe
4. Model FG3000 - Strobe
Material: galvanized steel
Mounting bracket will accommodate
vertical tower members from 1.5”
to 4.5” in diameter. Standard “U”–
bolts are used to secure the bracket
to the tower.
To mount beacon or strobe to the
bracket, use H&P mounting assembly
Part Number – A6A0001SE
BEACON/STROBE ICE SHIELD ASSEMBLY
SUPPORT ANGLE
TOWER LEG
EXPANDED METAL –
PARTIALLY OMMITTED FOR
CLARITY OR ILLUSTRATION
“U”– BOLTS
Part Numbers:
LRB58L7510M
A6A0302A13 A6A0302AA2 NH7510CB2
DOUBLE
BEACON/
STROBE
Lightning Rod Assembly
Lightning Rod
Mounting Ring
Jam Nut
HUGHEYANDPHILLIPS.COM
SUPPORT ANGLE
SECURING BRACKET
ACCESSORIES
Load Balance Resistor
LB112120 – 120V, 1200W
Application
The proper operation of electrical and electronic devices in general
is based on the availability of a relatively steady line voltage. This
condition is usually met without special precaution when the several
connected loads all consume a steady amount of power. If one
or more of the loads are of a varying or pulsating nature, then the
degree of steadiness of the line voltage (i.e. line voltage regulation)
will be dependent upon several factors – such as:
• The voltage regulation of the power service to the installation
(i.e. is the power service a firm-heavy source with adequate
capacity or a soft source at the end of a rural line).
• The size of the conductors between the power service and the
connected load. In many cases the size is not adequate for the
load, thus causing a large voltage drop.
• The size and voltage regulation of the standby generator.
• The relative size of the pulsating load as related to the total
connected load at site.
Also of prime importance is the relative sensitivity of the electronic
or radio equipment to the variations in the line voltage. The rules
of the FCC and FAA require the 300mm Beacon to flash ON and
OFF at a rate between 20 and 40 flashes per minute. The beacon
normally uses two 620 watt lamps, thus a pulsating load of 1240
watts. Assuming a rate of 30 FPM, the 1240 watt load is ON for
1-1/3 seconds and OFF for 2/3 seconds. Due to some inrush
current when the lamps are ON, the effect on the line voltage may
be slightly more severe than flashing a resistive load of 1240 watts.
In some installations, the 1240 watt pulsating load may represent
a substantial portion of the total connected load. In these cases
the variations in the line voltage may be quite severe and some
corrective means must be considered. Fortunately, a relatively simple
and quite effective corrective means is available – a Load Balance
Resistor. This consists of a 1200 watt resistive load which is switched
ON as the Beacon load is switched OFF and vice versa.
The Hughey and Phillips LB112120 and LB212480 Load Balance
Resistors (LBR) are designed for use with flashing Beacons and will
minimize fluctuations in the beacon lighting load circuit, when used
is conjunction with our 9LC Lighting Controls. Housed in a louvered
galvanized steel case, the LBR is suitable for outdoor installations.
The mounting brackets are movable in order to provide for mounting
against a vertical or horizontal surface. Connection to the LBR is
made to a terminal strip mounted in a watertight cast junction box
which is tapped for ½” conduit or conduit fitting. The resistive
elements are of the strip type to provide uniform heat distribution
and are of steel-sheath construction with compressed insulation.
SiteGuard® WC-60
Wireless Monitoring
Hughey & Phillips’ Digital Cellular Communicators deliver secure,
reliable and complementary digital communications via the GSM
(Global System for Mobile) network.
This groundbreaking communications solution offers full data
reporting and uploading/downloading with most Hughey & Phillips
control panels. In addition, with onboard zone inputs and optional
dialer capture capability, we’re compatible with other manufacturers’
security panels as well. All signals are delivered to the AlarmNet
Network Control Center, which routes the information to the
appropriate central station. The state-of-the-art AlarmNet Network
Control Center is fully redundant and monitored 24/7. AlarmNet has
the ability to route messages using AlarmNet-i and
800 PLUS services, providing true redundancy and multi-path
message delivery.
SiteGuard® monitoring services handles all of the time dependent
monitoring tasks without requiring your interaction: if a light “burns
out”, Hughey & Phillips’s system does the following:
• Dry contact output is read into the SiteGuard System
• SiteGuard initiates alarm call over a GSM wireless connection
• Alarm received at ProtectionNet Network operations center, with
operators providing around the clock, 365 days a year service
• ProtectionNet initiates an FAA Notice to Airmen (NOTAM) for any
appropriate lighting failure
• The client is notified of the failure via telephone, voicemail, pager,
fax or e-mail
• With the NOTAM in place, you can now work at your own schedule
to repair the light outage
• If after 14 days we have not heard from you, we will contact you to
determine the status of your tower
• We will file the NOTAM extension if necessary or we will remove
the NOTAM, with no additional work from you
Part Numbers:
OBMISC215 Digital Cellular Communicator (SiteGuard WC-60)
OBMISC236 GSM Antenna, outdoor, GSM-ANT3DB,
omni-directional
SMISC234GSM Adapter Cable, WA7626-CA SMA to N
Adapter
MC000017GSM Coaxil Cable, 25’
Wind Turbine Switch
The Hughey & Phillips Wind Turbine Switch (WTS)
is designed to operate the required obstruction
lighting from either the high voltage generated
by the wind turbine within the nacelle or from
the commercial power supplied at the base of
the tower. Utilizing patent-pending technology,
the WTS senses the highest voltage present and
powers the obstruction lighting at either 120VAC
or 230VAC. The WTS harnesses the power of wind to power your
obstruction lighting requirements.
877.285.4466 Toll Free
59
ACCESSORIES
junction boxes
Weathertight Cast Aluminum for Surface Mounting
General Information
Hughey & Phillips Weathertight Junction Boxes are of cast aluminum.
Each box is of adequate size for the number of terminals to enable
proper and simplified installation. All boxes are furnished complete with
cover, gasket, cover retaining chain and self-retaining type cover screws.
Tapping - Hughey & Phillips Weathertight Junction Boxes are
available with or without tapped conduit hubs. In ordering,
specify size.
Terminals - Hughey & Phillips Weathertight Junction Boxes are
available with standard screw type terminal blocks, or special blocks
Junction Box No. JB00000000
with split connectors, or combinations, to customer order. The
terminal capacity indicated under each type of box is representative
of one type terminal block…all terminal strips are insulated.
Insulated Cable Supports - Hughey & Phillips Weathertight Junction
Boxes are available with built-in cable support (with or without
terminals) to meet requirements of the National Electric Code.
Insulated Bushing - Hughey & Phillips will install, when specified,
plastic insulating bushings inside of tapped conduit hubs.
Junction Box No. JC00000000
Description
Cast aluminum, watertight, complete with cover and screws, gasket,
and cover retaining chain. Available with or without terminal block,
and/or cable support.
Specifications
Inside Dim. (Approx.)
Capacity
Max. Hub Tap
60
HUGHEYANDPHILLIPS.COM
5 3/8” Dia. 2 5/8” Depth
5 Term. (Kulka No. 603-5)
7 Term. (Buchanan Type HD)
1” Cond. Size
Description
Cast aluminum, watertight, complete with cover and screws, gasket,
and cover retaining chain. Available with or without terminal block,
and/or cable support.
Specifications
Inside Dim. (Approx.)
Capacity
Max. Hub Tap
L 4 7/8”, W 7”, D 4”
8 Term. (Kulka No. 603-8)
10 Term. (Buchanan Type HD)
1” Cond. Size
ACCESSORIES
junction boxes
Weathertight Cast Aluminum for Surface Mounting
Junction Box No. JF00000000
Junction Box No. JG00000000
Description
Cast aluminum, watertight, complete with cover, cover screws,
gasket, and cover retaining chain. Available with or without terminal
blocks, and/or cable support, screw-cap receptacles, etc. Furnished
with mounting bars or mounting clamps, if specified on order.
Specifications
Inside Dim. (Approx.)
Capacity
**Max. Hub Tap
L 10”, W 9”, D 5”
20 Term. (2-Kulka No. 603-10)
24 Term. (Buchanan Type HD)
Sides (R, L**) 1” Top & Bottom
(T, B**) 2” Cond. Size
*Order junction boxes by number, and specify hub tapping**,
number & type of terminals, & with or without...cable support,
insulating bushings, receptacles, mounting rails, etc.
Description
Cast aluminum, watertight, complete with cover, cover screws,
gasket, and cover retaining chain. Available with or without terminal
blocks, and/or cable support, screw-cap receptacles, etc. Furnished
with mounting bars or mounting clamps, if specified on order.
Specifications
Inside Dim. (Approx.)
Capacity
**Max. Hub Tap
L 15”, W 9”, D 5”
30 Term. (3-Kulka No. 603-10)
36 Term. (Buchanan Type HD)
Sides (R, L**) 1” Top & Bottom
(T, B**) 2” Cond. Size
*Maximum hub taps indicated are for standard boxes. Larger hub
size and taps available on special order.
Method of Specifying Conduit Hub Taps
conduit size symbols
Conduit Size
Ordering Symbol
/ ”
2
1 2
/ ”
3
3 4
1”
4
1 1/4”
5
1 1/2”
6
2”
7
Example:Cat. No. JC Type Box to be topped 1 1/4” top and bottom
Conduit Hub Tap Location Symbols
XXTRBL
X
00
XX
(Type (Taps)
(Cable
(# of Term
Box)
Support PosBlock)
Optional)
and 3/4” left side only.
Order As: Junction Box Cat. No JC5053C03B
877.285.4466 Toll Free
61
ACCESSORIES
K-Z Series Beacon Flasher
Conforms to FAA and FCC specification. Completely calibrated to applicable FAA/FCC
specifications by factory technicians. No field adjustment ever necessary.
Ultra reliable: surge and transient resistance components.
High power: rating 2.0KW maximum continuous tungsten load at up to 131° F (+55°C)
ambient air temperature 120 or 240 VAC option per circuit.
Flash rate: 30 FPM; 2/3 on, 1/3 off duty cycle.
Fail safe operation: normally closed solid state relay configuration assures “lights on”
condition even if control circuitry fails.
Visible operation indicator red LED (light emitting diode) provides instant visual
verification of field operation.
Modular construction: Easy field installation or retrofit for existing applications. Easy
replacement if damaged.
Specifications
Input Voltage: 120 VAC 1 0 / 240 VAC 1 0
Power Rating: 2000 Watts maximum, continuous duty (zero voltage switching)
Flash rate: 30 FPM; 2/3 on, 1/3 off duty cycle
Peak Current Surge: 320 Amps’ 100 milliseconds, 650 amps, 1 cycle @ 60 Hz
(non repetitive)
Operating Temperature: -55°C to +55°C
Transient Suppression: 2.5 KV@ 10 milliseconds components to case
Reliability: MTBF over 500,000 hrs (SSR) per MIL-217C
List of Standard Solid State Beacon Flashers
Part Number Description
KZ1L10R30A KZ2L10R30A KZ1L1RR30A KZ2L1RR30A KZ1L20E30A KZ2L20R30A KZ1L2PR30A KZ2L2PR30A KZ1L2SR30A KZ2L2SR30A KZ1L2QR30A KZ2L2QR30A KZ1S3T030BA KZ3S3T030B KZ1S3T030A KZ2L4N03BA KZ1L4NR30A KZ1S4N030AA KZ1S5N030AA KZ1S5N030A KZ1S6N030AAB KZ1S7Z030B KZ1S7U030A 1-Beacon 120V
1-Beacon 240V
1-Beacon & Load Balance Resistor 120V
1-Beacon & Load Balance Resistor 240V
2-Beacon Simultaneous 120V
2-Beacon Simultaneous 240V
2-Beacon Alternate 120V
2-Beacon Alternate 240V
2-Beacon & 2 Load Balance Resistor Simultaneous 120V
2-Beacon & 2 Load Balance Resistor Simultaneous 240V
2-Beacon & 2 Load Balance Resistor Alternate 120V
2-Beacon & 2 Load Balance Resistor Alternate 240V
3-Beacon Simultaneous 120V
3-Beacon Simultaneous 240V
3-Beacon Sequential 120/208V
4-Beacon Simultaneous 240V
4-Beacon 2+2 180°Apart 120V
4-Beacon Sequential 120/208V
5-Beacon Sequential 120/208V
5-Beacon 4 Position 120/208V (2 Beacon Top)
6-Beacon 4 Position 120/208 V (3 Beacon Top)
7-Beacon 120/208 V (Top & Bottom Flash Together)
7-Beacon 5 Position 3 Beacon Top 120/208V
62
HUGHEYANDPHILLIPS.COM
lighting
systems
LIGHTING SYSTEMS
64
HUGHEYANDPHILLIPS.COM
LIGHTING SYSTEMS
877.285.4466 Toll Free
65
LIGHTING SYSTEMS
66
HUGHEYANDPHILLIPS.COM
LIGHTING SYSTEMS
877.285.4466 Toll Free
67
LIGHTING SYSTEMS
68
HUGHEYANDPHILLIPS.COM
LIGHTING SYSTEMS
r epai r se r vices
a global lea d e r
Hughey & Phillips is
a global leader in the
design and manufacturing
of obstruction lighting
technology. We engineer
and design a complete
line of low, medium and
high intensity lighting
technology solutions
for radio, television,
and communication
towers; wind turbines; buildings; smokestacks; bridges;
and other obstructions to aerial navigation. All products are
Hughey & Phillips offers a vast selection repair services
manufactured by Hughey & Phillips in the USA. With a full
for tower lighting controllers, flashheads and beacons.
engineering staff providing complete support and design in
Our repair service department offers customers a fast and
optical, electrical and mechanical disciplines to customize any
economical method to overhaul their fielded equipment
of our products to fit our customers’ unique needs. To learn
for years of operation.
more, visit www.hugheyandphillips.com
877.285.4466 Toll Free
69
LIGHTING SYSTEMS
70
HUGHEYANDPHILLIPS.COM
LIGHTING SYSTEMS
877.285.4466 Toll Free
71
LIGHTING SYSTEMS
72
HUGHEYANDPHILLIPS.COM
LIGHTING SYSTEMS
877.285.4466 Toll Free
73
LIGHTING SYSTEMS
74
HUGHEYANDPHILLIPS.COM
LIGHTING SYSTEMS
877.285.4466 Toll Free
75
faa
standards
faa standards
Red Obstruction Lighting Standards (FAA Style A)
Day Protection = Aviation Orange / White Paint
Night Protection = 2,000cd Red Beacon and sidelights
1751’ - 2100’
1401’ - 1750’
1051’ - 1400’
= L-864 flashing beacon
= L-810 obstruction light
701’ - 1050’
351’ - 700’
151’ - 350’
0’ - 150’
a-0
a-1
a-2
a-3
a-4
a-5
Notes:
1.The overall height of the structure including all appurtenances such as rods, antennas, obstruction lights, etc.,
determines the number of light levels.
2.The red obstruction lighting system is composed of flashing omnidirectional beacons (L-864) and/or steady burning
(L-810) lights. When one or more levels is comprised of flashing beacon lighting, the lights should flash simultaneously.
3.The chart above illustrates the requirements for standard lighting of towers and supporting structures in accordance
with FAA Advisory Circular 70/7460-1; Chapters 3, 4, 5, and 12.
78
HUGHEYANDPHILLIPS.COM
a-6
faa standards
High Intensity Obstruction Lighting Standards (FAA Style B)
Day Protection = 200,000cd White Strobe
Twilight Protection = 20,000cd White Strobe
Night Protection = 2,000cd White Strobe
1751’ - 2100’
1401’ - 1750’
1051’ - 1400’
701’ - 1050’
351’ - 700’
= L-856 high intensity
strobe (3 flashheads
required per level
for 360o coverage)
B-2
B-3
B-4
B-5
B-6
Notes:
1. The height of the main structure excluding all appurtenances such as rods, antennas, obstruction lights, etc.,
determines the number of light levels. Note: Any appurtenances over 40 feet (12 meters) requires additional lighting,
consisting of a Medium Intensity L-865 White Strobe, see FAA Style C.
2. When high intensity white lights are operated 24 hours a day, other methods of marking and lighting may be omitted.
This system should not be recommended on structures 500 feet (153 meters) AGL or less unless an FAA aeronautical
study shows otherwise.
3. The chart above illustrates the requirements for standard lighting of towers and supporting structures in accordance
with FAA Advisory Circular 70/7460-1; Chapters 3, 4, 7, and 12.
877.285.4466 Toll Free
79
faa standards
High Intensity Obstruction Lighting Standards (FAA Style C)
Day Protection = 200,000cd White Strobe
Twilight Protection = 20,000cd White Strobe
Night Protection = 2,000cd White Strobe
1751’ - 2100’
1401’ - 1750’
1051’ - 1400’
701’ - 1050’
501’ - 700’
= L-856 high intensity strobe
(3 flashheads required per
level for 360o coverage)
= L-865 medium intensity
strobe required
appurtenances of
40 feet or greater
c-2
c-3
c-4
c-5
Notes:
1.The height of the main structure excluding all appurtenances such as rods, antennas, obstruction lights, etc.,
determines the number of light levels. Note: Any appurtenances over 40 feet (12 meters) requires additional lighting,
consisting of a Medium Intensity L-865 White Strobe.
2. When high intensity white lights are operated 24 hours a day, other methods of marking and lighting may be omitted.
This system should not be recommended on structures 500 feet (153 meters) AGL or less unless an FAA aeronautical
study shows otherwise.
3. The chart above illustrates the requirements for standard lighting of towers and supporting structures in accordance
with FAA Advisory Circular 70/7460-1; Chapters 3, 4, 7, and 12.
80
HUGHEYANDPHILLIPS.COM
c-6
faa standards
Medium Intensity White Obstruction Lighting Standards
(FAA Style D)
Day/Twilight Protection = 20,000cd White Strobe
Night Protection = 2,000cd White Strobe
Painting of tower is typically not required
351’ - 500’
= L-865 FLASHING WHITE
STROBE
1/2 but not lower
than 200 feet (61m)
200’ - 350’
D-1
D-2
Notes:
1. The overall height of the structure including all appurtenances such as rods, antennas, obstruction lights, etc.,
determines the number of light levels.
2. The medium intensity flashing white light system is normally composed of flashing omnidirectional lights. This system
is not normally recommended on structures less than 200 feet AGL.
3. The chart above illustrates the requirements for standard lighting of towers and supporting structures in accordance
with FAA Advisory Circular 70/7460-1; Chapters 3, 4, 6, and 12.
877.285.4466 Toll Free
81
faa standards
Medium Intensity Dual Obstruction Lighting Standards
(FAA Style E)
Day/Twilight Protection = 20,000cd White Strobe
Night Protection = 2,000cd Red Strobe and Sidelights
Painting of tower is typically not required
351’ - 500’
= L-864/L-865 flashing
dual (white/red) strobe
= L-810 obstruction light
1/2 but not lower
than 200 feet (61m)
200’ - 350’
e-1
e-2
Notes:
1.The overall height of the structure including all appurtenances such as rods, antennas, obstruction lights, etc.,
determines the number of light levels.
2. The dual lighting system includes red lights (L-864) for nighttime and medium intensity flashing white lights (L-865)
for daytime and twilight use. This lighting system may be used in lieu of operating a medium intensity flashing white
lighting system at night. Some populated areas where the use of white medium intensity at night may cause significant
environmental concerns, the use of the dual lighting system should reduce/mitigate those concerns.
3. The chart above illustrates the requirements for standard lighting of towers and supporting structures in accordance
with FAA Advisory Circular 70/7460-1; Chapters 3, 4, 8, and 12.
82
HUGHEYANDPHILLIPS.COM
faa standards
Dual High Intensity Obstruction Lighting Standards
(FAA Style F)
Day Protection = 200,000cd White Strobe
Twilight Protection = 20,000cd White Strobe
Night Protection = 2,000cd Red Beacon and Sidelights
1751’ - 2100’
1401’ - 1750’
1051’ - 1400’
701’ - 1050’
501’ - 700’
= L-856 high intensity strobe
(3 flashheads required per
level for 360o coverage)
= L-864 flashing red beacon
= L-810 red obstruction light
f-2
F-3
f-4
F-5
F-6
Notes:
1. The height of the main structure excluding all appurtenances such as rods, antennas, obstruction lights, etc., determines the number of
light levels. Note: Any appurtenances over 40 feet (12 meters) requires additional lighting, consisting of a Medium Intensity L-865 White
Strobe and a L-864 Red Beacon.
2. This dual lighting system includes red light (L-864) for nighttime and high intensity flashing lights (L-856) for daytime and twilight
use. This lighting system may be used in lieu of operating a high intensity flashing white lighting system at night. There may be some
populated areas where the use of high intensity lighting may cause significant environmental concerns. The use of the dual lighting
system should reduce/mitigate those concerns.
3. The chart above illustrates the requirements for standard lighting of towers and supporting structures in accordance with FAA Advisory
Circular 70/7460-1; Chapters 3, 4, 9, and 12.
877.285.4466 Toll Free
83
faa standards
Bridge and Wind Turbine Lighting
L-864 or L-865 or
(L-864 / L-865)
Front View
84
HUGHEYANDPHILLIPS.COM
side View
notes
877.285.4466 Toll Free
85
notes
86
HUGHEYANDPHILLIPS.COM
notes
877.285.4466 Toll Free
87
Broadcast
Telecommunications
Wind Turbines
Tall Structures
Utilities
ABOUT OUR COMPANY
Hughey & Phillips is a leader in the design and
manufacturing of obstruction lighting technology.
We produce a complete line of lighting solutions that
provide illumination for aerial navigation around the
world. And we offer complete power and lighting
systems designed and manufactured in the USA. Our
cost-effective obstruction lighting technology provides
highly efficient and reliable lighting solutions. By
offering complete support and design in electrical,
optical and mechanical disciplines, Hughey & Phillips
can fully customize any product to fit the unique needs
of any customer.
877.285.4466 Toll Free
937.652.3500 Telephone
937.652.3508 FAX
HUGHEYANDPHILLIPS.COM
240 W. Twain Ave
Urbana, OH 43078
The Evolution of a BranD
For more than 75 years Hughey & Phillips has earned a
reputation for quality, dependability and innovation in
obstruction lighting around the globe.
1930’s – 1970’s
1970’s – 2000
2000 – Present