• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Application of VFD in Condenser Pumps in Thermal Power Plant 1
Application of VFD in Condenser Pumps in Thermal Power Plant 1

... of VFD is out of power completely, it may continue to operate for 3 seconds, thus to satisfy the requirements of continuous operation of VFD, when the power lines of the VFD switches. In addition, when the main power supply of 6KV is low voltage, the VFD will continue to operate with derated voltage ...
control strategies for generator side converter of direct driven
control strategies for generator side converter of direct driven

... of converter, operation at relatively low wind direct driven Permanent magnet synchronous generator speeds is possible due to the inclusion of the boost circuit. variable speed WECS systems integrated with power The boost circuit maintains the DC bus link voltage at a electronic interfaces are becom ...
IEC 61000-4-5 standard overview
IEC 61000-4-5 standard overview

Manual - Teletronics International, Inc
Manual - Teletronics International, Inc

... Highly Secured Wireless Network The access point supports the highest available wireless security standard: IEEE802.11i compliant. The access point also supports IEEE 802.1x for secure and centralized user-based authentication. Wireless clients are thus required to authenticate through highly ...
The Next Generation Wireless
The Next Generation Wireless

... Problems with NAAs  Need to be inline with client traffic  Currently can only be done with VLAN trunking  Very complicated (messy) design ...
Chapter 6
Chapter 6

Simulation and Hardware Implementation of DC
Simulation and Hardware Implementation of DC

... where I and V are the PV array output current and voltage, respectively. The left-hand side of the equations represents the IncCond of the PV module, and the right-hand side represents the instantaneous conductance. From (1)–(3), it is obvious that when the ratio of change in the output conductance ...
Lecture 1 Power Amplifiers
Lecture 1 Power Amplifiers

...  RL  ...
Target Tracking Slides
Target Tracking Slides

... Useful even if an accurate model is not known ...
Technical specification for tender pm7-specifications-en
Technical specification for tender pm7-specifications-en

... All power demand calculations shall use any one of the following calculation methods, selectable by the user: Block interval, with optional sub-intervals. The window length shall be set by the user from 1-60 minutes in 1 minute intervals. The user shall be able to set the sub-interval length from 1- ...
Merging SONET and Ethernet Communications for Power System
Merging SONET and Ethernet Communications for Power System

... individually routed across the network without the concept of establishing an end-to-end connection between applications. This enables Ethernet to more efficiently utilize bandwidth. However, neither SONET and SDH nor Ethernet has remained the same since being introduced. SONET and SDH have evolved ...
IEEE Transactions on Magnetics
IEEE Transactions on Magnetics

... sources and try to contribute something for the nation in term of electric power awareness.[7-8] The interest in renewable ...
Article
Article

Strand Dimming Systems Power and Diming Control solutions for
Strand Dimming Systems Power and Diming Control solutions for

BM 6a mk II.qxp
BM 6a mk II.qxp

Debunking 10 Gigabit Ethernet Myths
Debunking 10 Gigabit Ethernet Myths

... Myth: Enterprises will have to completely rip and replace switches or do forklift upgrades to support 10 Gigabit Ethernet. Reality: Many enterprises will discover that the modular switches running Gigabit Ethernet in their networks are capable of supporting 10 GbE line cards. Also, many new 10 GbE f ...
Network4 - Rhema Impact Ministries
Network4 - Rhema Impact Ministries

1500 Watt MOSORB® Transient Voltage Suppressor, 6.8 V Unidirectional
1500 Watt MOSORB® Transient Voltage Suppressor, 6.8 V Unidirectional

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave

... PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries ...
AN341 - Diodes Incorporated
AN341 - Diodes Incorporated

... used to connect one or two DisplayPort source devices to one or two DisplayPort sink devices. PI3VDP12412 offers two packaging options, 48 BGA and 42 TQFN. 48 BGA package is recommended for transmitting Dual-mode DP signaling as it carries SCL and SDA paths. PI3VDP12412NE for 2:1 Dual-mode DP source ...
USB cable schematic pinout
USB cable schematic pinout

... used for Human Input Devices (HID) such as keyboards, mice, joysticks and often the buttons on higher speed devices such as printers or scanners; Full Speed (12 Mbit per second) which is widely supported by USB hubs, assumes that devices divide the USB bandwidth between them in a first-come first-se ...
SEMESTER 1 Chapter 5
SEMESTER 1 Chapter 5

... * What is the “random backoff” in CSMA/CD? How does it work?  After a collision occurs and all devices allow the cable to become idle (each waits the full interframe spacing), the devices whose transmissions collided must wait an additional - and potentially progressively longer - period of time be ...
choice of wind turbine location according to its influence on the
choice of wind turbine location according to its influence on the

AG4201218222
AG4201218222

... restrictions and social problems too. Thus effective utilization of the existing transmission systems with the help of new technologies so called Flexible AC Transmission Systems (FACTS) devices[3]. Here we are using Unified Power Flow Controller (UPFC) for ATC enhancement in between the areas, Sinc ...
The Seven Types Of Power Problems
The Seven Types Of Power Problems

< 1 ... 373 374 375 376 377 378 379 380 381 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report