• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Building Energy Management System Using Powerline
Building Energy Management System Using Powerline

... Power line communication (PLC) carries data on a conductor that is also used simultaneously for AC electric power transmission or electric power distribution to consumers [4]. Typically transformers prevent propagating the signal, which requires multiple technologies to form very large networks. Var ...
AU4101266270
AU4101266270

... third term in (3) represents the change in the effective capacitive reactance of the TCSC due to the action of the TCSC supplementary controller. This scheme would, definitely, be economically attractive when compared with a full three-phase TCSC which has been used/proposed for power oscillations d ...
LOGO!Power Power supply LOGO!Power
LOGO!Power Power supply LOGO!Power

A reliable tool to comply with Standards
A reliable tool to comply with Standards

1) Provide Voltage Stabilization
1) Provide Voltage Stabilization

View - APERC
View - APERC

Identification Solutions for Data Center Infrastructure
Identification Solutions for Data Center Infrastructure

... services to critical business applications. Any disruption of the physical infrastructure could cause interruption of business applications, resulting in lost revenue. Many of today’s physical infrastructure disruptions are caused by moves, adds, or changes within the environment. The advantage of a ...
Introduction to Power System Analysis
Introduction to Power System Analysis

... The choice of Frequency (2) 50 Hz and 60 Hz • A too low frequency, like 10 or 20 Hz causes flicker • A too high frequency • Increases the hysteresis losses: ...
FAQ: Extended temperature mid
FAQ: Extended temperature mid

... forklifts, agricultural equipment and small form factor AC-DC adapters. What is IPC-9592? The IPC9592 standard establishes industry performance requirements for power conversion devices. The standard states that power MOSFETS must be derated by 25° C from the max rated junction temperature. That mea ...
AR01415591564
AR01415591564

... significantly higher than CCT without control. It was also observed that STATCOM can provide higher stability limit Fig:9 Swing curves of New England System with control than that of a SVC of similar rating. In the 10-machine 39Fig:8 shows the swing curves of all the machines of the bus system, the ...
DN520 - Versatile Industrial Power Supply Takes High Voltage Input
DN520 - Versatile Industrial Power Supply Takes High Voltage Input

... Martin Merchant Introduction Today’s industrial electronic systems contain many of the same components as consumer electronics— microcontrollers, FPGAs, system-on-chip ASICs and other electronics—requiring multiple low voltage rails at widely varied load currents. Industrial applications can also de ...
SIMULATED DESIGN OF 5 STAGE CMOS RING OSCILLATOR FOR
SIMULATED DESIGN OF 5 STAGE CMOS RING OSCILLATOR FOR

... The designers use 200 milli-volt peak to peak differential swing for the general serial-link structures and because of these low swings only, a small amount of stray signal can also create a significant problem. As a result, the effect of noise in a transmission line is much more-effective when the ...
AHH1 Series Albeo Industrial High Bay | ALB037
AHH1 Series Albeo Industrial High Bay | ALB037

... to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to ...
Quad 14 Gbps L-band VCSEL-based system for
Quad 14 Gbps L-band VCSEL-based system for

... In this paper we look into high-speed, cost-efficient and power-efficient VCSEL-based WDM system oriented towards short-range optical fiber connectivity. Four L-band VCSELs are directly modulated with quaternary pulse amplitude modulation (4-PAM) signal at 7 Gbauds to generate a total data nominal r ...
Energy Efficient Wide Bandgap Devices
Energy Efficient Wide Bandgap Devices

... pairing the SiC Schottky diode with a SiC MOSFET. The typical switch currently in use is a low on-resistance silicon MOSFET, such as Infineon’s CoolMOS device. However, due to the high breakdown electric field of SiC, even higher doping levels can be used for the same blocking voltage, so lower on-r ...
Design of Operational Amplifier in 45nm Technology
Design of Operational Amplifier in 45nm Technology

... power and area using the 45 nm technology. Operational transconductance amplifier is different based upon the output from the convental operational amplifier. In Two stage amplifier it is not sue that improved phase margin will give better response always[6]. In transconductance operational amplifie ...
HiTek Power Technical Datasheet
HiTek Power Technical Datasheet

Chapter 11: AC Steady-State Power 11.1 Instantaneous and
Chapter 11: AC Steady-State Power 11.1 Instantaneous and

... ‡ Powerfactorcorrection: theprocessof increasing thepowerfactor withoutalteringthevoltageorcurrenttotheoriginalload. ‡ Tomitigatetheinductiveaspectoftheload,acapacitorisaddedin parallelwiththeload.Thepowerfactorhasimproved. ...
Specification - Pathway Connectivity
Specification - Pathway Connectivity

Series 70 ePODs: Type-P - LayerZero Power Systems, Inc
Series 70 ePODs: Type-P - LayerZero Power Systems, Inc

Owner`s Guide for the Bass Amplifier
Owner`s Guide for the Bass Amplifier

... of your V4BH are covered in detail within the pages of this owner’s guide. We recommend going over them before you use the amplifier. ...
Power Management in Portable Systems Using MAX II CPLDs
Power Management in Portable Systems Using MAX II CPLDs

... Power management is more than simply achieving the lowest standby power dissipation possible. There are three aspects of power design: dissipation, simplicity, and transitions. Dissipation is the most obvious power management reduction objective of system designers. Power dissipation has two basic c ...
Copper Media - Faculty - Genesee Community College
Copper Media - Faculty - Genesee Community College

... in Ethernet LANs Consists of _____________________ that have been twisted together and then encased in a flexible plastic ...
Power Flow Control and Voltage Profile Improvement Using Unified
Power Flow Control and Voltage Profile Improvement Using Unified

MS1040 product datasheet
MS1040 product datasheet

... relevant sections of IEC60945 (see overleaf for test details). This type-approved combination of hardware and Mariner Kit can be used as the display platform for your critical navigation, control, loading and general purpose applications. ...
< 1 ... 370 371 372 373 374 375 376 377 378 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.