• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
PREOBRAZOVATEL
PREOBRAZOVATEL

... of motors and transformers); - container design for drilling pumps drives; - modular (inbuilt) design using reactor-transformer and protection-switching equipment of the Customer.  Microprocessor control unit (MCU) have the following distinctive features: - MCU are unified for all КТЕ5 nomenclature ...
Voltage Fluctuation Impacts (T. McDermott, Sep 2009)
Voltage Fluctuation Impacts (T. McDermott, Sep 2009)

... Voltage Fluctuation Impacts (T. McDermott, Sep 2009) Any type of distributed generation can produce voltage fluctuations on the electric power system. For example, photovoltaic power output can drop from 100% to 20% of nameplate in less than one minute, and wind power output of a single turbine can ...
Fiber Optic Network Solutions
Fiber Optic Network Solutions

... In the broadband communication, the fiber optic network deployment is increasingly applied to today’s cloud applications and high-demanding multimedia streaming service. The fiber optic transmission has large advantages over the existing copper wire as the optic fiber cable carries much lower attenu ...
`Before Using Your Amplifier`.
`Before Using Your Amplifier`.

... cart/apparatus combination to avoid injury from tip-over. 13) Unplug this apparatus during lightning storms or when unused for long periods of time. 14) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cor ...
QCMC 2011 - Iris Power
QCMC 2011 - Iris Power

... Time Based Maintenance (TBM) methods. Modern GIS is by its advanced design, virtually maintenance free, so a time based approach is essentially meaningless, and there is a strong case to employ Condition Based Maintenance (CBM) instead. The adoption of on-line condition monitoring of key parameters ...
Unit.5 Power Quality Monitoring
Unit.5 Power Quality Monitoring

... • The process of gathering data is usually carried out by continuous measurement of voltage and current over an extended period. • The process of analysis and interpretation has been traditionally performed manually, but recent advances in signal processing and artificial intelligence fields have ma ...
Power Gain - 4th semester
Power Gain - 4th semester

... We can take the logarithm of both sides to get Multiplying both sides by 10 gives Which can be written as ...
Automatic Power Factor Correction by Using Synchronous
Automatic Power Factor Correction by Using Synchronous

TECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION

Document
Document

... converter is also derived analytically. Conduction losses, switching losses, and efficiency estimation are provided considering the transmitter and receiver side of the wireless converter. The proposed control strategy adjusts the output voltage of the system by phase-shift tuning of the active swit ...
Parallel Operation of Shunt Active Power Filters for Damping of
Parallel Operation of Shunt Active Power Filters for Damping of

... desirable duc to communication latencies. Instead an independent control approach for each individual may be quicker, and, in fact, may have better redundancy. ...
3Com OfficeConnect Secure Router
3Com OfficeConnect Secure Router

Avaya Virtual Services Platform 8404
Avaya Virtual Services Platform 8404

... enables businesses to satisfy many typical deployments scenarios with a consistent hardware platform. Mid-sized businesses are increasingly ...
Cisco WAP551 and WAP561 Wireless-N Access Points Quick Start Guide
Cisco WAP551 and WAP561 Wireless-N Access Points Quick Start Guide

... • Check the state of the indicator lights. See “Verifying the Hardware Installation” on page 6. • Check the Ethernet cable to ensure that it is firmly connected to your devices. Devices connected by the Ethernet cable can include the WAP device, and routers, any switches, and your computer. • Verify ...
activity8-old
activity8-old

How Micron SSDs Handle Unexpected Power Loss
How Micron SSDs Handle Unexpected Power Loss

MS-5UD-3E - Fire
MS-5UD-3E - Fire

... Panel) and the MS-10UD-7(E) is a ten-zone FACP. These control panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional buildings. Both panels include built-in communicators for Central Station Service and remote upload/download. ...
section 283111 - digital, addressable fire-alarm system
section 283111 - digital, addressable fire-alarm system

... Special load considerations, including starting inrush currents and frequent starting and stopping. Transformer characteristics, including primary protective device, magnetic inrush current, and overload capability. Motor full-load current, locked rotor current, service factor, starting time, type o ...
Ethernet - SigmaNet
Ethernet - SigmaNet

... larger frames by using the system mtu global configuration command. Because the 802.1Q tunneling feature increases the frame size by 4 bytes when the metro tag is added, you must configure all switches in the service-provider network to be able to process larger frames by increasing the switch syste ...
Description Pin Assignments 15W STEREO CLASS-D AUDIO POWER AMPLIFIER WITH POWER LIMIT
Description Pin Assignments 15W STEREO CLASS-D AUDIO POWER AMPLIFIER WITH POWER LIMIT

... tolerance on this trip point from device to device. Once the die temperature exceeds the set thermal point, the device enters into the shutdown state and the outputs are disabled. This is not a latched fault. The thermal fault is cleared once the temperature of the die is reduced by 50°C. The device ...
TW-522 802.11ac Dual Radio Wallplate Specification Sheet
TW-522 802.11ac Dual Radio Wallplate Specification Sheet

... All the in-room connections you need In addition to 802.11n Wi-Fi access, the TW-522 provides two 10/100MB managed Ethernet ports and a passthrough RJ-11 port for an in-room analog telephone. Installation is a snap Installation is fast and easy. All you need is a screwdriver — no special tools or in ...
Modeling and Control of the PFC Stage for a 50KW EV Fast
Modeling and Control of the PFC Stage for a 50KW EV Fast

... feasible solution, the FC must satisfy both the grid code in terms of THD and power factor from the utility side and lithium-ion charging modes from the battery side. Since the BSS usually contains multiple FCs, its impact on the distribution grid is very significant, as was shown by previous resear ...
www.ee.washington.edu
www.ee.washington.edu

... HE AREA OF applications for radio-frequency identification (RFID) is increasing rapidly. Applications include supply chain management, access control to buildings, public transportation, and open-air events, airport baggage, express parcel logistics, and many more. The need for high volume, low cost ...
RF430F5978EVM Optimized Power Consumption
RF430F5978EVM Optimized Power Consumption

CENTRALE OPERATIVA_inglese
CENTRALE OPERATIVA_inglese

... robbery, aggression, etc. It also provides logistical information, including checking the position, the routes taken, the times and the speed of movement. The system has been optimised thanks to the use of more precise and detailed vectorial-type cartography. The position of the vehicle can be displ ...
< 1 ... 341 342 343 344 345 346 347 348 349 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report