• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
wire and cable terminology
wire and cable terminology

... Impact Strength: A test for determining the mechanical punishment a cable can withstand  without physical or electrical breakdown by impacting with a given weight, dropped a given  distance, in a controlled environment.   Impedance: The total opposition that a circuit offers to the flow of alternat ...
ER33863872
ER33863872

... 1) Switching frequency of the bridge which shares the minimum power will increase. 2) At the cost of the fourth bridge reduction in THD is not appreciable. 3) Master Bridge(higher rating voltage bridge) will have to share the max. Power 4) Distribution of power will not be uniform. 5) Rating of the ...
Megaplex-2100/2104
Megaplex-2100/2104

... topologies. In case of link failure on any segment of the ring, RFER reroutes the traffic (both the TDMoIP traffic and the protected ...


switches
switches

... 10-100 Gbps* 10GBASE-SR ...
Hd1800
Hd1800

... 4) System hum: Switch the rear GND LIFT switch IN or OUT. If hum is not eliminated, then install Carvin’s MTF55 “Ground Lifter” between the amplifier input and signal source. This isolates the input ground from the AC power ground. 5) Poor sound (bass): The speaker systems are wired out of ph ...
Aalborg Universitet J.; Sørensen, T.
Aalborg Universitet J.; Sørensen, T.

... process [6]. The different properties that are generally considered are the random nature of the arcing time, current chopping ability, the dielectric strength between contacts, and the quenching capabilities of the high frequency current at zero crossing [7]. In [8] a procedure to estimate the VCB ...
Constructional Project
Constructional Project

Distributed generation and voltage changes in a distribution network
Distributed generation and voltage changes in a distribution network

... The voltage level at each load connection point is one of the most important parameters for the quality of supply. The technical regulations or specific contracts define the allowed voltage range that bounds the maximum permitted variation of every bus-bar voltage. Furthermore, the voltage limit is ...
Achieving Phase Accuracy for LTE-A
Achieving Phase Accuracy for LTE-A

... Client Time = (Receive Time – Originate Time) + (Transmit Time – Client Time Received) Offset ...
Power Electronics and Reliability in Renewable Energy
Power Electronics and Reliability in Renewable Energy

... The wind turbine technology is one of the most emerging renewable energy technologies [3]-[12]. It started in the 1980’es with a few tens of kW production power per unit to today with multi-MW size wind turbines that are being installed. It also means that wind power production in the beginning did ...
W i d e   B a n d... P o w e r   A m p...
W i d e B a n d... P o w e r A m p...

... combined with the comparably high impedance attainable by these devices also offers new possibilities for wideband power microwave systems. In this thesis, Class C switching response of SiC MESFET in TCAD and two different generations of broadband power amplifiers have been designed, fabricated and ...
High Speed, Dual, 4 A MOSFET Driver ADP3654
High Speed, Dual, 4 A MOSFET Driver ADP3654

... electrically and thermally connected to the die substrate, which is the ground of the device. It is recommended to have the exposed pad and the PGND pin connected on the PCB. ...
IEEE Transactions on Magnetics
IEEE Transactions on Magnetics

... The structure of the ZVS-SVM controlled three-phase PWM rectifier is similar to the ACRDCL converter. With the special SVM scheme proposed by the authors, both the main switches and the auxiliary switch have the same and fixed switching frequency. The reverse recovery current of the switch be turned ...
Control of DFIG-WT under unbalanced grid voltage conditions
Control of DFIG-WT under unbalanced grid voltage conditions

STA-16 STATUS INPUT INTERFACE
STA-16 STATUS INPUT INTERFACE

... (20) Data Terminal Ready (DTR)-output from your PC. ...
(CCM) and Discontinuous Conduction Mode (DCM)
(CCM) and Discontinuous Conduction Mode (DCM)

... linear systems for nonlinear systems; we may not be able to easily compute the solution to the optimal control problem as analytical solutions may not be available, problem is that statically-stable wheeled mobile robots can easily become dynamically unstable. If the center of gravity is too high, o ...
Aalborg Universitet Reduced junction temperature control during low-voltage ride-through for single-
Aalborg Universitet Reduced junction temperature control during low-voltage ride-through for single-

... such power electronics based PV systems operating in a harsh environment, where the solar irradiance level is not constant and the grid conditions may change suddenly (e.g. voltage sag due to short-circuit faults). As it has been presented in [15], the PV inverter has been the critical part with the ...
C-more panels
C-more panels

... The AC/DC Power Adapter provides dedicated DC power to the panel if using 110 VAC as a power source. The AC/DC Power Adapter provides some features that a normal DC power supply cannot provide. The adapter provides a power loss signal to the touch panel that can be used to track power outages. This ...
Thermal Analysis of Power Semiconductor Converters
Thermal Analysis of Power Semiconductor Converters

... Gheorghe Asachi Technical University of Iasi Romania 1. Introduction Power devices may fail catastrophically if the junction temperature becomes high enough to cause thermal runaway and melting. A much lower functional limit is set by temperature increases that result in changes in device characteri ...
Pre-Installation Manual SkyVision Linx 300 Integration Control System TEC-R-0047 REV1
Pre-Installation Manual SkyVision Linx 300 Integration Control System TEC-R-0047 REV1

... The SKYTRON SkyVision Linx 300 Integration Control System installation can vary according to the specific equipment needs of the OR facility. What is common in all installations is that video and data input sources are routed to various outputs such as displays, video recorders, or networks providin ...
power flow analysis of three phase unbalanced
power flow analysis of three phase unbalanced

... Radial distribution system can be modeled as a network of buses connected by distribution lines, switches or transformers. Each bus may also have a corresponding load, shunt capacitor and/or cogenerator connected to it. This model can be represented by a radial interconnection of copies of the basic ...
Hyfrecator Manual
Hyfrecator Manual

... For coagulation procedures using forceps. When using forceps, the forceps plug into both bipolar outlets (a footswitch is required when forceps are utilized). Bipolar provides between zero and 35 watts with a voltage lower than the high or low output terminals. 10. SWITCHING CONNECTOR The power up/d ...
Liebert GXT4 Intelligent, Reliable UPS Protection
Liebert GXT4 Intelligent, Reliable UPS Protection

... The Proven Reliability Of True On-Line Operation With The Features You Need Most The Liebert® GXT4™ UPS requires just a slim 2U of rack space, but provides the capabilities often found only in larger systems. Get up to 3kVA of capacity and battery backup. External battery cabinets may be added for e ...
Reactive Power Control to Assist Wind Penetration
Reactive Power Control to Assist Wind Penetration

... compliance analysis with UK grid codes. Conclusion is made that for short connection (20km), DFIG can comply with grid codes without additional support. On the other hand, for 100km cable, STATCOM of at least 60MVAr would be needed to provide adequate voltage support from the wind farm. Reference [9 ...
< 1 ... 225 226 227 228 229 230 231 232 233 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report