analysis of load test, transformation, turns ratio, efficiency and
... The method is simple, efficient and accurate, by an exhaustive analysis. The following constraints are imposed: excitation current, load fractions, efficiency and voltage regulations. The methodology of this paper requires only two input data: primary side of the transformer and the secondary side o ...
... The method is simple, efficient and accurate, by an exhaustive analysis. The following constraints are imposed: excitation current, load fractions, efficiency and voltage regulations. The methodology of this paper requires only two input data: primary side of the transformer and the secondary side o ...
Review on Superconducting Fault Current Limiter
... value TC. Under fault conditions, when the current exceeds IC, the resistance of superconductor significantly increases due to quenching and this SN transitions then acts like a limiter switch [6]. This version of the SFCL utilizes a resistor in parallel with the superconducting material that protec ...
... value TC. Under fault conditions, when the current exceeds IC, the resistance of superconductor significantly increases due to quenching and this SN transitions then acts like a limiter switch [6]. This version of the SFCL utilizes a resistor in parallel with the superconducting material that protec ...
A New Definition of Mutual Impedance between Two Coils for
... Using (5), we find that the uncoupled voltages can be obtained very accurately with percentage errors generally smaller than 10−6% when compare with the ideal uncoupled voltages, which are obtained when coils are receiving in isolation. These extremely small percentage errors indicate the accurate q ...
... Using (5), we find that the uncoupled voltages can be obtained very accurately with percentage errors generally smaller than 10−6% when compare with the ideal uncoupled voltages, which are obtained when coils are receiving in isolation. These extremely small percentage errors indicate the accurate q ...
C6200 GENCONTROLLER Function Description
... The excitation loss protection will protect the alternator from the consequences of a loss of excitation, when running in parallel with other alternators or the grid. It will also prevent the remaining alternators from over current and thus prevent blackout. The unit is not measuring the excitation ...
... The excitation loss protection will protect the alternator from the consequences of a loss of excitation, when running in parallel with other alternators or the grid. It will also prevent the remaining alternators from over current and thus prevent blackout. The unit is not measuring the excitation ...
S31115120
... Fig.6 and Fig.7 represents the stator flux locus of conventional DTC and twelve sectors DTC respectively. By comparing the results of flux locus of C_DTC and 12_DTC, we can observe that the flux repulsion has been reduced in 12_DTC compared with C_DTC. In order to check theoretically, the percentage ...
... Fig.6 and Fig.7 represents the stator flux locus of conventional DTC and twelve sectors DTC respectively. By comparing the results of flux locus of C_DTC and 12_DTC, we can observe that the flux repulsion has been reduced in 12_DTC compared with C_DTC. In order to check theoretically, the percentage ...
User and Installation Manual
... Use a heavy gauge ground strap from the motor case to the case of the controller. The motor windings will couple energy to the case of the motor through the interwinding capacitance. This will in turn cause increased emissions from the drive if not returned to the source. Shielding of the motor lead ...
... Use a heavy gauge ground strap from the motor case to the case of the controller. The motor windings will couple energy to the case of the motor through the interwinding capacitance. This will in turn cause increased emissions from the drive if not returned to the source. Shielding of the motor lead ...
Redi-Flo Variable Frequency Drive Manual
... pump as the MP1 and the Redi-Flo4 pumps as SPE. They may be referred to as either in this manual. ...
... pump as the MP1 and the Redi-Flo4 pumps as SPE. They may be referred to as either in this manual. ...
Selection Guide to Clamp-On Current Probes
... Crest factor — ratio of crest (peak, max imum) value to root-mean-square (rms) value. ...
... Crest factor — ratio of crest (peak, max imum) value to root-mean-square (rms) value. ...
Rockwell Automation Allen-Bradley Specification SMC
... possible with a separate stop input. c.) Stop time programmable from 0 to 999 seconds. d.) The load shall stop when the motor voltage drops to a point where the load torque is greater than the motor torque 3. Linear speed deceleration a.) Stop time programmable from 0 to 999 seconds. b.) Current lim ...
... possible with a separate stop input. c.) Stop time programmable from 0 to 999 seconds. d.) The load shall stop when the motor voltage drops to a point where the load torque is greater than the motor torque 3. Linear speed deceleration a.) Stop time programmable from 0 to 999 seconds. b.) Current lim ...
DC Machines
... present there right now, will have some definite induced voltage in it (dictated by e = blv). In course of rotation of the armature newer conductors will occupy this position in space. No matter which conductor comes to that particular position at any given point of time, it will have same voltage i ...
... present there right now, will have some definite induced voltage in it (dictated by e = blv). In course of rotation of the armature newer conductors will occupy this position in space. No matter which conductor comes to that particular position at any given point of time, it will have same voltage i ...
Rockwell Automation Allen-Bradley Specification SMC
... possible with a separate stop input. c.) Stop time programmable from 0 to 999 seconds. d.) The load shall stop when the motor voltage drops to a point where the load torque is greater than the motor torque 3. Linear speed deceleration a.) Stop time programmable from 0 to 999 seconds. b.) Current lim ...
... possible with a separate stop input. c.) Stop time programmable from 0 to 999 seconds. d.) The load shall stop when the motor voltage drops to a point where the load torque is greater than the motor torque 3. Linear speed deceleration a.) Stop time programmable from 0 to 999 seconds. b.) Current lim ...