• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Aalborg Universitet during Grid Fault
Aalborg Universitet during Grid Fault

... Finally two fault situations have been studied with the two developed wind turbine models. The influences on the generator as well as the behaviour of the wind turbine during these faults are briefly discussed based on the simulation results. It can be concluded, that it has been possible to build a ...
here
here

... • We can reflect the load from one side of a transformer to the other side of a transformer. • This trick allows us to combine the two separate primary/secondary circuits for easy(?) calculation. ...
1. What is the nature from a safety standpoint of the switch in the
1. What is the nature from a safety standpoint of the switch in the

... iii. Since GenerLink uses your existing breaker panel, you can run any large 120 or 240-volt appliance up to your generator’s capacity. Your well pump, water heater, sump pump, electric range, clothes dryer and electric baseboard heat are just some of the appliances that can be run on a rotation bas ...
Current transformer relaying accuracies
Current transformer relaying accuracies

... This discussion will deal primarily with current transformers having a rated secondary current of 5 A. A supplementary discussion of current transformers with rated secondary current of 1 A is also included. IEEE C57.13 CT relaying accuracy classes IEEE defines two fundamental relaying accuracy desi ...
ECE4762007_Lect19
ECE4762007_Lect19

... Thus the models of generators (and other rotating machines) are very important since they contribute the bulk of the fault current. Generators can be approximated as a constant voltage behind a time-varying reactance ...
Electric and Magnetic Fields and Your Health
Electric and Magnetic Fields and Your Health

... Electricity transmission and distribution lines in New Zealand operate at voltages between 230 volts (normal household voltage) and 220,000 volts (220 kV). A line capable of operating at up to 400 kV was put into service in 2012, but will only operate at 220 kV until about 2035. In other countries, ...
view file - Dr. Ahmed ElShafee
view file - Dr. Ahmed ElShafee

... • we choose as our path of integration a  circle of radius r • B will be tangent to the circle.  • since all points on the path are the same  distance from the wire, by symmetry we  expect B to have the same magnitude at  each point. Dr. Ahmed ElShafee, ACU : Spring 2016, Electromagnetic Fields • /e ...
CTFaradayAns
CTFaradayAns

... also be out (toward the observer). The induced current will be counterclockwise, in order to make an induced B-field out. F-6. A square loop is rotating in a fixed, external magnetic field into the page. At the instant shown, the loop is out of the plane of the page with left side of the loop above ...
Module 6: Transformers
Module 6: Transformers

TEMP EFFECTS full paper Jan3.indd
TEMP EFFECTS full paper Jan3.indd

Magnets for Accelerators - Wiley-VCH
Magnets for Accelerators - Wiley-VCH

Type Rated operational Rated operational Control voltage voltage
Type Rated operational Rated operational Control voltage voltage

... by-passing of the semiconductors during running operation. Therefore the semiconductors can only be damaged by short-circuit currents during ramp-up and ramp-down function. ...
Average Current Control Mode Boost Converter for
Average Current Control Mode Boost Converter for

TOOL FOR QUALITY TESTING OF RAW MATERIAL OF
TOOL FOR QUALITY TESTING OF RAW MATERIAL OF

... for characterization. A pulsed magnetometer is useful for testing high-performance magnets due to their ability to produce higher magnetic fields. The basic geometry, coil winding configuration and input currents of the pulsed field magnetometer are calculated using FEM and MATLAB/Simulink. The whol ...
Aalborg Universitet Current Source Converters for Microgrid Applications
Aalborg Universitet Current Source Converters for Microgrid Applications

... I. INTRODUCTION Nowadays, microgrids are gaining more and more attentions [1], [2]. Typically, the back-to-back voltage source converters are used to interconnect the microgrids [3]-[6]. However, the voltage source converters require bulky and temperature-limited electrolytic capacitors. The failure ...
101 basics series starters and contactors
101 basics series starters and contactors

... So, how exactly does the contactor open and close? The E-Frame, when energized by the coil, becomes an electromagnet. The armature, a companion to the Eframe, is connected to a set of contacts. The armature is moveable but is held by a spring. When the coil is energized, the moveable contacts are pu ...
Improving Efficiency in AC drives: Comparison of Topologies and Device Technologies
Improving Efficiency in AC drives: Comparison of Topologies and Device Technologies

... GPD is to explain with the need of low audible noise in this application. Based on this Figure it is visible that the losses are even more concentrated in the IGBTs and FWDs, 59%, and thus the rated VSD efficiency ηVSD-LFT1 is 96.68 %. High-Speed Drives The high-speed drives require higher switching ...
Characterisation of Large Disturbance Rotor Angle and
Characterisation of Large Disturbance Rotor Angle and

Calculation Method of Losses and Efficiency of Wind
Calculation Method of Losses and Efficiency of Wind

Using BLDC motors in small home appliances
Using BLDC motors in small home appliances

SEL-710 Motor Protection Relay
SEL-710 Motor Protection Relay

planning - The Physics Cafe
planning - The Physics Cafe

Charging Around the Circuit
Charging Around the Circuit

The starter representing the electric motor посто
The starter representing the electric motor посто

... moment at increase of braking of an anchor that facilitates start-up двига-теля. Force of the current consumed by a starter at his(its) work, does not remain to a constant and depends on a condition of the storage battery, сопро-тивления an electric circuit and frequency враще-ния anchors. Owing to ...
Accionamiento de motores de corriente contínua sin
Accionamiento de motores de corriente contínua sin

< 1 ... 34 35 36 37 38 39 40 41 42 ... 378 >

Electric machine

The academic study of electric machines is the universal study of electric motors and electric generators. By the classic definition, electric machine is synonymous with electric motor or electric generator, all of which are electromechanical energy converters: converting electricity to mechanical power (i.e., electric motor) or mechanical power to electricity (i.e., electric generator). The movement involved in the mechanical power can be rotating or linear.Although transformers do not contain any moving parts they are also included in the family of electric machines because they utilise electromagnetic phenomena.Electric machines (i.e., electric motors) consume approximately 60% of all electricity produced. Electric machines (i.e., electric generators) produce virtually all electricity consumed. Electric machines have become so ubiquitous that they are virtually overlooked as an integral component of the entire electricity infrastructure. Developing ever more efficient electric machine technology and influencing their use are crucial to any global conservation, green energy, or alternative energy strategy.