AN1560: Making Accurate Voltage Noise and Current Noise
... Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that the Application Note or Technical Brief is current before proceeding. ...
... Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that the Application Note or Technical Brief is current before proceeding. ...
4316C-part1
... chemistry, for which the equipment was designed and manufactured. 5.2.4 breathing zone — imaginary globe, of 600 mm (two foot) radius, surrounding the head. 5.2.5 capture velocity — the air velocity that at any point in front of the exhausted hood or at the exhausted hood opening is necessary to ove ...
... chemistry, for which the equipment was designed and manufactured. 5.2.4 breathing zone — imaginary globe, of 600 mm (two foot) radius, surrounding the head. 5.2.5 capture velocity — the air velocity that at any point in front of the exhausted hood or at the exhausted hood opening is necessary to ove ...
What is Lightning - Academica-e
... understood the mechanism of lightning. It is one of the most beautiful displays in nature and one of the nature's most dangerous phenomenon known to man. Overvoltage due to lightning is a very important problem of LV systems. Some lightning flashes damage buildings and a few kill or injure people an ...
... understood the mechanism of lightning. It is one of the most beautiful displays in nature and one of the nature's most dangerous phenomenon known to man. Overvoltage due to lightning is a very important problem of LV systems. Some lightning flashes damage buildings and a few kill or injure people an ...
Old Company Name in Catalogs and Other Documents
... customers or third parties arising from the use of these circuits, software and information. • While NEC Electronics endeavors to enhance the quality, reliability and safety of NEC Electronics products, customers agree and acknowledge that the possibility of defects thereof cannot be eliminated enti ...
... customers or third parties arising from the use of these circuits, software and information. • While NEC Electronics endeavors to enhance the quality, reliability and safety of NEC Electronics products, customers agree and acknowledge that the possibility of defects thereof cannot be eliminated enti ...
Universal motor speed control and light dimmer with TRIAC and
... brightness of a bulb when a lamp is connected as the load (the light dimmer). The potentiometer should be used to control motor speed. An additional feature that can be enabled on this board is temperature control through the Negative Temperature Coefficient (NTC) component. Although it is not a sta ...
... brightness of a bulb when a lamp is connected as the load (the light dimmer). The potentiometer should be used to control motor speed. An additional feature that can be enabled on this board is temperature control through the Negative Temperature Coefficient (NTC) component. Although it is not a sta ...
Coordinated Circuit Protection for USB Applications
... The result of an imbalance of electrons between two objects separated by a dielectric is static electricity. This type of electrostatic discharge, or ESD, is a well-known phenomenon that can cause various types of failures in electronic systems. System failures can be generally classified into two c ...
... The result of an imbalance of electrons between two objects separated by a dielectric is static electricity. This type of electrostatic discharge, or ESD, is a well-known phenomenon that can cause various types of failures in electronic systems. System failures can be generally classified into two c ...
Terminations
... must not exceed the max output current limit Driving two or more lines required a lower pull-down resistor value ...
... must not exceed the max output current limit Driving two or more lines required a lower pull-down resistor value ...
A Complete Electrical Hazard Classification
... capacitors, inductors, batteries, and radiofrequency (RF) power. The electrical hazards of these forms of electricity and their systems are different than for 50160 Hz power. Over the past 10 years there has been an effort to develop a method of classifying all of the electrical hazards found in all ...
... capacitors, inductors, batteries, and radiofrequency (RF) power. The electrical hazards of these forms of electricity and their systems are different than for 50160 Hz power. Over the past 10 years there has been an effort to develop a method of classifying all of the electrical hazards found in all ...
Common Failure Mechanisms in Microelectronics
... Package-level reliability testing refers to the assessment of the over-all reliability of the device in packaged form. This consists of subjecting packaged samples to reliability tests that expose the various sample sets to different stress conditions, after which the samples are tested for any deg ...
... Package-level reliability testing refers to the assessment of the over-all reliability of the device in packaged form. This consists of subjecting packaged samples to reliability tests that expose the various sample sets to different stress conditions, after which the samples are tested for any deg ...
Electromagnetic compatibility

Electromagnetic compatibility (EMC) is the branch of electrical sciences which studies the unintentional generation, propagation and reception of electromagnetic energy with reference to the unwanted effects (electromagnetic interference, or EMI) that such energy may induce. The goal of EMC is the correct operation, in the same electromagnetic environment, of different equipment which use electromagnetic phenomena, and the avoidance of any interference effects.In order to achieve this, EMC pursues two different kinds of issues. Emission issues are related to the unwanted generation of electromagnetic energy by some source, and to the countermeasures which should be taken in order to reduce such generation and to avoid the escape of any remaining energies into the external environment. Susceptibility or immunity issues, in contrast, refer to the correct operation of electrical equipment, referred to as the victim, in the presence of unplanned electromagnetic disturbances.Interference mitigation and hence electromagnetic compatibility is achieved by addressing both emission and susceptibility issues, i.e., quieting the sources of interference and hardening the potential victims. The coupling path between source and victim may also be separately addressed to increase its attenuation.