• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
EA20 SEriES EA20 SEriES
EA20 SEriES EA20 SEriES

Accurately measuring nanoamperes Using the Fluke 8808A
Accurately measuring nanoamperes Using the Fluke 8808A

... simple, because current leakage typically falls in the low microampere range, and measurements made with traditional DMMs can be inaccurate. The reason for the inaccuracies is that DMMs usually measure current by applying a known resistance in the form of a shunt resistor in series with the circuit ...
Bellringer - Madison County Schools
Bellringer - Madison County Schools

... An advantage of AC over DC is that AC voltage can be easily raised or lowered to a higher or lower voltage. This means that a high voltage can be used to send electrical energy over great distances, then the voltage can be reduced to a safer level for everyday use. Nikola Tesla is credited for creat ...
Circuits with Troubleshooting
Circuits with Troubleshooting

Loop and Nodal Analysis and Op Amps
Loop and Nodal Analysis and Op Amps

EDS 06-0012 Earthing Design Criteria - Document Library
EDS 06-0012 Earthing Design Criteria - Document Library

... beings and the proximity to sensitive third party equipment. There are general cases where application of risk assessment can help in arriving at a sensible, cost effective design. For example, if the amount of high voltage equipment at a substation is minimal (a transformer within a durable, non-me ...
Core Balance Specify Document
Core Balance Specify Document

346N_No19_Elect_Design2
346N_No19_Elect_Design2

... Objectives • Review conductor and conduit selection • Learn about protection systems (basic rules) • Learn to design Residential Electrical Systems ...
DEPARTMENT OF ELECTRICAL ENGINEERING EA6210: SWITCHGEAR AND PROTECTION DIT UNIVERSITY, DEHRA DUN
DEPARTMENT OF ELECTRICAL ENGINEERING EA6210: SWITCHGEAR AND PROTECTION DIT UNIVERSITY, DEHRA DUN

... 1. Measurement of displacement using LVDT. 2. Measurement of displacement using strain gauge based displacement transducer. 3. Measurement of displacement using magnetic pickup. 4. Measurement of load using strain gauge based load cell. 5. Measurement of water level using strain gauge based water le ...
View Electrical Safety Training
View Electrical Safety Training

... Note: A GFCI will not protect you from line contact hazards (i.e. a person holding two "hot" wires, a hot and a neutral wire in each hand, or contacting an overhead power line). However, it protects against the most common form of electrical shock hazard, the ground-fault. It also protects against f ...
Measuring Voltages and Currents
Measuring Voltages and Currents

... The voltmeter is the standard instrument used to measure the voltage difference between two points in a circuit. To measure V12 in the circuit below, we connect the (+) terminal of the voltmeter to terminal 1 and the (−) terminal to terminal 2. Connecting the voltmeter to the circuit does not requir ...
Ohm`s Law
Ohm`s Law

... Ohm: The Man Ohm, Georg Simon (1787-1854), German physicist, best known for his research on electrical currents. He was born in Erlangen and educated at the University of Erlangen. From 1833 to 1849 he was director of the Polytechnic Institute of Nürnberg, and from 1852 until his death he was profe ...
Study Guide
Study Guide

... 28. The north pole of a compass points to which geographic pole? Explain your answer. 29. How can you adjust the coil wires on an electromagnet to make the electromagnet stronger? 30. Give an example of a ferromagnetic material. 31. Explain the energy transformation of an electric motor? 32. Explain ...
Fact sheet for Electricity and Magnetism Year 8 Lesson One
Fact sheet for Electricity and Magnetism Year 8 Lesson One

... attracting ...
REC15_AL / REC25_AL
REC15_AL / REC25_AL

... Voltage sensing is carried out by conductive rubber screens that are capacitively coupled to the HV terminals. Current sensing is performed by six Rogowski sensors, one sensor per each HV terminal. Rogowski sensors are current sensors that produce a safe, low voltage output. Three star connected sen ...
Download Industrial Shock-Block Datasheet
Download Industrial Shock-Block Datasheet

... Class C GFCIs is introduced to be used on systems where the line-to-line voltage is 480 V or less with a trip level of 20 mA, while Class D GFCI is intended to be used on 600 V systems. These improvements to the standard Class A GFCI (6 mA trip level used on 240 V systems or less) were made to allow ...
Kirchhoff`s Laws and Superposition
Kirchhoff`s Laws and Superposition

... circuit. This will be your +15 volt supply. Turn on the DC power supply and adjust the output voltage to about 15 V. Measure and record the voltage obtained. Do not change this voltage. 4. Measure each of the branch voltages with the digital voltmeter and enter them into Table 1. A branch voltage is ...
Neptune Branch Unit - APL
Neptune Branch Unit - APL

...  One advantage of energizing the system with positive voltage is that the local BU intelligence will be able to differentiate between fault locating mode and restoration mode (depending on the direction of current).  Could we use two different voltage levels for fault locating and ...
Department of Computer Science & Engineering
Department of Computer Science & Engineering

... circuit, but in many other high voltage applications too. Also, it was found out that using the boost converter design, it doesn’t matter how high of current you draw, it is the physical amount of current you draw. So you can use a small amount of current, but pulse the circuit really fast and achie ...
BD63823EFV
BD63823EFV

... The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM and other parties. ...
How you can produce an electric current
How you can produce an electric current

Rose LED Project
Rose LED Project

... optimum level, and thus minimizing the system power loss. At the same time, accurate current regulation for each of the 32 LED strings is maintained. The LX24232 includes an on-chip analog to digital converter for drain voltage (VD) measurements, for power supply control, fault detection and protect ...
Ohm Zone: Series Circuit I
Ohm Zone: Series Circuit I

... http://www.article19.com/shockwave/oz.htm Below is the menu from OhmZone. Click on the “popups” button that is the question mark. This will give you a description of each of the components as your mouse moves over them. You will find this very useful. ...
We`re more than just cables and cord sets. Terminology Term and
We`re more than just cables and cord sets. Terminology Term and

... Ground-Fault Circuit-Interrupter. An electrical wiring device that disconnects a circuit whenever it detects that the electric current is not balanced between the energized conductor and the return neutral conductor. Such an imbalance is sometimes caused by current leakage through the body of a pers ...
Instructions OpenDrop Prototype – Digital Microfludics
Instructions OpenDrop Prototype – Digital Microfludics

... The foil (5-7 um thick) should lay flat on the electrode array with no air gap in between. A thin film of mineral oil can be applied to the electrodes before applying the foil. The electrodes are gold coted and not isolated. Make sure that no conductive liquids come in contact with the electrodes or ...
< 1 ... 305 306 307 308 309 310 311 312 313 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.