• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Approval marks and symbols
Approval marks and symbols

... equipment) summarises EU directive 2002/95/EC on the prohibition of certain substances in the manufacture and processing of electrical and electronic equipment and components. The ENEC mark (European Norms Electrical Certification) is a European mark of conformity and confirms that the device on whi ...
DN130 - Power Supplies for Subscriber Line Interface Circuits
DN130 - Power Supplies for Subscriber Line Interface Circuits

... capacitors and lowers the RMS currents, allowing the use of cheaper output capacitors. Either the – 23.8V output or the – 71.5V output can be at full load without effecting the other corresponding output. The circuit’s step response is very good; no significant overshoot occurs after either output i ...
Lecture 5
Lecture 5

... indicates the presence of a magnetic field (see Magnetism) around ...
AQ 1000 – Arc Quenching Device AQ 1000 Benefits
AQ 1000 – Arc Quenching Device AQ 1000 Benefits

... most applications this will result in a calorie/cm2 energy release of less than 1. The AQ 1000 is fully reusable allowing for full system testing at site. ...
Laboratory Electrical Safety - Tufts Public Safety
Laboratory Electrical Safety - Tufts Public Safety

Basic Electrical Concepts And Hazards
Basic Electrical Concepts And Hazards

Zero Current Monitor E-1076-SR 5
Zero Current Monitor E-1076-SR 5

... current transformer and an opto decoupled output circuit with a triac (with AC output circuit) or transistor (with DC output circuit). The current transformer in the monitoring circuit does not only supply the input signal but also the very low power consumption of the Monitor. Zero current monitors ...
Series Parallel Circuits 9.1 Key
Series Parallel Circuits 9.1 Key

... What happens to the total resistance of a series circuit wUen another resistor is added? ...
File
File

Two - Schneider Electric
Two - Schneider Electric

electric circuit
electric circuit

Electricity and Magnetism
Electricity and Magnetism

WEEK NO
WEEK NO

... WEEK NO - 2 ...
EE 311: EE Junior Lab Single Phase Transformers
EE 311: EE Junior Lab Single Phase Transformers

... X 1 primary winding leakage reactance R resistance representing core losses X m magnetizing reactance R2 secondary winding resistance X 2 secondary winding leakage reactance ...
2. Real time scheduling algorithm for fault tolerant and energy
2. Real time scheduling algorithm for fault tolerant and energy

Need for protection
Need for protection

... In order to carry out the above duties, protection must have the following qualities: • Selectivity: To detect and isolate the faulty item only. • Stability: To leave all healthy circuits intact to ensure continuity or supply. • Sensitivity: To detect even the smallest fault, current or system abno ...
Feb 2001 48V Hot Swap Circuit Blocks Reverse Battery Voltage
Feb 2001 48V Hot Swap Circuit Blocks Reverse Battery Voltage

... power reaches the LT1641 and Q1, allowing them to function in the normal manner. When the LT1641 is ...
Document
Document

... current is complete and unbroken. An open circuit is one in which the pathway of the electrical current is broken. A switch is a device in the circuit in which the circuit can be closed (turned on) or open (turned off). ...
78ET-1 - Marine Engineering Study Materials
78ET-1 - Marine Engineering Study Materials

Series and Parallel Circuits 1 - Instructor Outline
Series and Parallel Circuits 1 - Instructor Outline

SPS range - Safety power supplies
SPS range - Safety power supplies

... 4 x 20mm knockouts are provided for cable entry at the rear of the enclosure Outputs are protected by electronic circuit breakers ...
Electricity Test Practice Problems
Electricity Test Practice Problems

... b. two objects with like charges will be repelled from each other. c. two objects with unlike charges will be repelled from each other. d. two objects will always be attracted to each other because of gravity. _____ 10. Electrostatic induction occurs a. when a charged object contacts a neutral objec ...
ALDEBARAN Flatlite 300 / 600 / 900 / 1200
ALDEBARAN Flatlite 300 / 600 / 900 / 1200

AC Line Regen Module Specification
AC Line Regen Module Specification

Power Supply HSD 9000 Series - Hima
Power Supply HSD 9000 Series - Hima

< 1 ... 309 310 311 312 313 314 315 316 317 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report