• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Chapter 11
Chapter 11

... A mode used in many “Green” systems that allows them to be configured through CMOS to suspend the monitor or even the drive, if the keyboard and/or CPU has been inactive for a set number of minutes ...
TIS Trailing Edge Dimmer 6 Channels 10 Amps
TIS Trailing Edge Dimmer 6 Channels 10 Amps

... TIS Trailing Edge Dimmer 6 Channels 10 Amps Model: DIM-W06CH10A-TE Data Sheet Rev 1.1 ...
Chapter 8: Data Communication Fundamentals
Chapter 8: Data Communication Fundamentals

...  1820s Faraday postulated that an electrical current moving through a wire creates "fields of force" surrounding the wire.  1821 Faraday built the first electric motor--a device for transforming an electrical current into rotary motion.  1831 Faraday made the first transformer. The unit of capaci ...
Power Quality Counts
Power Quality Counts

... now you’re conducting much higher currents in a much smaller wire. So harmonics create heat, which over a period of time, raises the temperature of the neutral. This increase in temperature can overheat the surrounding conductors, cause insulation failure and overheat the transformer sources, which ...
String Combiners in SolarEdge Systems, North America
String Combiners in SolarEdge Systems, North America

... All sources of current need to be considered: multiple series strings of PV modules connected in parallel to the inverter as well as the string inverter itself. SolarEdge inverters have been verified to provide zero backfeed current to the input source circuits. When overcurrent protection is requir ...
5a) Characteristics of a series circuit:
5a) Characteristics of a series circuit:

551.74 Table 551.73 Demand Factors for Site
551.74 Table 551.73 Demand Factors for Site

... spliced by listed means. The arrangement of equipment grounding connections shall be such that the disconnection or removal of a receptacle or other device will not interfere with, or interrupt, the grounding continuity. (B) Secondary Distribution System. Each secondary distribution system shall be ...
Science Olympiad Circuit Lab
Science Olympiad Circuit Lab

... decreases. The internal resistance is in series with the total resistance of the circuit. Electrical Capacitance (C) – the amount of charge which must be added or removed to change the electric potential difference by one volt, i.e. C = ∆q/∆V Farad (F) – SI unit of electrical capacitance. ...
The Exact Equivalent Circuit of a Transformer
The Exact Equivalent Circuit of a Transformer

Meters - Electrical Synergy
Meters - Electrical Synergy

... The organization that produces the National Electric Code. The NFPA outlines the minimum safety requirements for any electrical installation. ...
Earth Mat Design - Goa Electricity Department
Earth Mat Design - Goa Electricity Department

Technical Note 6297: Neutral Conductor Size for Sunny Boy
Technical Note 6297: Neutral Conductor Size for Sunny Boy

AC_Circuits2
AC_Circuits2

... Where  is the phase angle between th e current and voltage ...
Practice Test-CP- Electricity 2010
Practice Test-CP- Electricity 2010

... fuses. (5) ...
Tens kilowatts power supply based on half
Tens kilowatts power supply based on half

... both the turning-on and turningoff of the switches at the zero current condition. Half-bridge inverter seems to be preferable due to the only two switch equipment, it lowers both the inverter costs and the switching loses. Half-bridge inverter operation in the proposed regime does not need the free- ...
Chabot College Fall 2002  44 - Introduction to Circuit Analysis
Chabot College Fall 2002 44 - Introduction to Circuit Analysis

... Before entering the course the student should be able to: 1. analyze and solve a variety of problems often using calculus in topics such as: 2. addition, subtraction, dot product and cross product of vectors a. linear and rotational kinematics b. dynamics c. momentum 3. work, kinetic energy, and pot ...
DP##Bx-B Data Line Models
DP##Bx-B Data Line Models

... are intended for installation as close to the electrical power source of the equipment as possible so as to allow for a common point for grounding. This device is for circuits with up to 3 pair of signal lines connected via the detachable terminal strips provided, making installation a breeze. A gro ...
Power Quality Counts
Power Quality Counts

Altech/ABL Sursum Miniature Circuit Breakers
Altech/ABL Sursum Miniature Circuit Breakers

... – Every Licensed Electrician can use the MCB, not only a UL Panel Shop – Manual Motor Controller is suitable for motor disconnect – Tested for these applications: – AC Motor Starting, Across the line – AC General use ...
Field Instruction
Field Instruction

... document the hazards and risks associated with the task and ensure appropriate control measures are put in place. The appropriate PPE must be worn, see (Section 2 Safety Field Instructions 2.1, 2.2, 2.5 and FI 2.6 Worksite Clothing / PPE Requirements) in this manual. ...
Electric Charge
Electric Charge

Section B: Electricity - Pearson Schools and FE Colleges
Section B: Electricity - Pearson Schools and FE Colleges

... several appliances in different parts of the same room to be connected to the mains using the minimum amount of wiring. Imagine how much wire would be needed if there was just one mains socket in each ...
Rack mount Power supply with 90
Rack mount Power supply with 90

... pulled up to 3.3V internally) Signifies that the power supply is plugged into the slot Short pin on the connector that enables the power supply to be hot pluggable Ground. Provides an isolated return for PS Present and I²C signals ...
Content
Content

... This document provides a policy for the neutral earthing of systems to be employed in Eskom Distribution’s HV, MV and LV networks. It further describes the policy with regard to the earthing of the neutral points of specific equipment: power transformers and capacitor banks. The earthing of Single W ...
Transformers AM326 KB
Transformers AM326 KB

< 1 ... 296 297 298 299 300 301 302 303 304 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report