• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
25471_energy_conversion_5
25471_energy_conversion_5

Thevenin_and_Norton_Equivalents
Thevenin_and_Norton_Equivalents

3-Phase Power Test Simulator IMA315 PORTABLE 3-PHASE POWER TEST SIMULATOR
3-Phase Power Test Simulator IMA315 PORTABLE 3-PHASE POWER TEST SIMULATOR

... IMA315 is a 3-phase current simulator in the Megacon range of transportable test equipment. This unit is designed for general testing of Megacon’s or other brands range of protective guards and controllers for generator and power plant automation systems (current, current differential, overcurrent a ...
Why true-rms?
Why true-rms?

CTIPe Model The Coupled Thermosphere Ionosphere
CTIPe Model The Coupled Thermosphere Ionosphere

Introduction
Introduction

... Too high voltage across oxide; hot electron injection. ...
What happens if I put a conductor into an electric field?
What happens if I put a conductor into an electric field?

McLean County Fair Book Supplement
McLean County Fair Book Supplement

ABSTRACT - 123SeminarsOnly.com
ABSTRACT - 123SeminarsOnly.com

... resistors required are expensive .One shot fuses can be used but they might fatigue and they must be replaced after a fault event. Another good solution available is the resettable Ceramic Positive Temperature Coefficient (CPTC) device. This technology is not widely used because of its high resistan ...
High Current I/O Module for Integrated Boating Control
High Current I/O Module for Integrated Boating Control

... Looking for a simpler way to integrate multiple loads, switches and sensors into your display system? Combined with our full range of HelmView™ displays, the Power Distribution Module (PDM) allows users to display and control trim tabs, ballast pumps, lighting, blowers and more. Users can integrate ...
continuity of current
continuity of current

LEARNING KNOTS ON ELECTRICAL CONDUCTION IN METALS
LEARNING KNOTS ON ELECTRICAL CONDUCTION IN METALS

... students on issues of particular complexity, such as the relationship between macroscopic and microscopic properties of material. Simulations can show a phenomenon and/or enable one to make predictions about its trend. Phet Interactive Simulations or Easy Java Simulations provide a microscopic repre ...
12 VOLT AC/DC POWER SUPPLY
12 VOLT AC/DC POWER SUPPLY

8.3 Electrical Current 2
8.3 Electrical Current 2

... Electrical Resistance : Affected by a Conductor’s Thickness • The thicker a wire, the lower its electrical resistance, just like it is easier to suck up a milkshake through a thicker straw than a thinner straw. ...
21676 Select test equipment and test an automotive
21676 Select test equipment and test an automotive

... are documented in memo or manual format and are available in the workplace. These requirements include but are not limited to – company specifications and procedures, work instructions, manufacturer specifications, product quality specifications and legislative requirements. Service information may ...
Definitions for Electric Service
Definitions for Electric Service

linear products automotive solenoid and lamp control
linear products automotive solenoid and lamp control

SMJE 2103
SMJE 2103

Earthing - WordPress.com
Earthing - WordPress.com

... Soil resistivity in the vicinity of ground electrode may be affected by current flowing from the electrode into the surrounding soil. The thermal characteristics and the moisture content of the soil will determine if a current of a given magnitude and duration will cause significant drying and thus ...
RPI-246
RPI-246

... The products listed in this document are designed to be used with ordinary electronic equipment or devices (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devic ...
File
File

3-phase switching power supply 400
3-phase switching power supply 400

PHET - DC Electric Circuit online Lab File
PHET - DC Electric Circuit online Lab File

cired wide area control strategy for multiple vsc
cired wide area control strategy for multiple vsc

...  It improves system stability significantly due to the decoupling of the AC systems, in other words, fault in one AC system will not affect the rest of the system. However, DC transmission systems are sensitive to small changes in voltage and vulnerable to DC faults. A fault in one of the DC links ...
Appendix D - Oxford University Press
Appendix D - Oxford University Press

< 1 ... 227 228 229 230 231 232 233 234 235 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report